Engineering Papers⌕ Search

Engineering topics

Fast, James E.

Publications and source records attributed to Fast, James E..

At least 73 records · Page 4

Measurement of the inclusive semileptonic branching fraction B ( B s 0 → X - ℓ + ν ℓ ) at Belle

Here, we report a measurement of the inclusive semileptonic B s 0 branching fraction in a 121 fb - 1 data sample collected near the Υ ( 5 S ) resonance with the Belle detector at the KEKB asymmetric energy e + e - collider. Events with B s 0 ( * ) B ¯ s 0 ( * ) pairs are selected by reconstructing a tag side D s + and identifying a signal side lepton ℓ + ( ℓ = e , μ ) that is required to have the same-sign charge to ensure that both originate from different B s 0 mesons. The B s 0 → X - ℓ + ν ℓ branching fraction is extracted from the ratio of the measured yields of D s + mesons and D s + ℓ + pairs and the known production and branching fractions. The inclusive semileptonic branching fraction is measured to be [ 10.6 ± 0.5 ( stat ) ± 0.7 ( syst ) ] % .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

THE MAJORANA DEMONSTRATOR: OVERVIEW AND STATUS UPDATE

The MAJORANA DEMONSTRATOR is being constructed at the Sanford Underground Research Facility (SURF) in Lead, SD by the MAJORANA Collaboration to demonstrate the feasibility of a tonne-scale neutrinoless double beta decay experiment based on 76Ge. The observation of neutrinoless double beta decay would indicate that neutrinos can serve as their own antiparticles, thus proving neutrinos to be Majorana particles, and would give information on neutrino masses. Attaining sensitivities for neutrino masses in the inverted hierarchy region requires large tonne-scale detectors with extremely low backgrounds. The DEMONSTRATOR project will show that sufficiently low backgrounds are achievable. A brief description of the detector and a status update on the construction will be given, including the work done at BHSU on acid-etching of Pb shielding bricks.

Keeter, K.↗

Cryostat for Ultra-low-energy Threshold Germanium Spectrometers

This paper presents progress on the development of a cryostat intended to improve upon the low-energy threshold (below 0.5 keV) of p-type point contact germanium gamma-ray spectrometers. Ultra-low energy thresholds are important in the detection of low-energy nuclear recoils, an event class relevant to both dark matter direct detection and measurement of coherent neutrino-nucleus scattering. The cryostat design, including a thermal and electrical-field model, is presented. A prototype cryostat has been assembled and data acquired to evaluate its vacuum and thermal performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The C-4 Dark Matter Experiment

Abstract We describe the experimental design of C-4, an expansion of the CoGeNT dark matter search to four identical detectors each approximately three times the mass of the p-type point contact (PPC) germanium diode presently taking data at the Soudan Underground Laboratory. Expected reductions of radioactive backgrounds and energy threshold are discussed, including an estimate of the additional sensitivity to low-mass dark matter candidates to be obtained with this search.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Multi-sensor Airborne Radiation Survey (MARS) Instrument

The Multi-sensor Airborne Radiation Survey (MARS) project has developed a new single cryostat detector array design for high purity germanium (HPGe) gama ray spectrometers that achieves the high detection efficiency required for stand-off detection and actionable characterization of radiological threats. This approach, we found, is necessary since a high efficiency HPGe detector can only be built as an array due to limitations in growing large germanium crystals. Moreover, the system is ruggedized and shock mounted for use in a variety of field applications, including airborne and maritime operations.

array↗

The MAJORANA experiment: an ultra-low background search for neutrinoless double-beta decay

The observation of neutrinoless double-beta decay would resolve the Majorana nature of the neutrino and could provide information on the absolute scale of the neutrino mass. The initial phase of the Majorana Experiment, known as the Demonstrator, will house 40 kg of Ge in an ultra-low background shielded environment at the 4850' level of the Sanford Underground Laboratory in Lead, SD. The objective of the Demonstrator is to validate whether a future 1-tonne experiment can achieve a background goal of one count per tonne-year in a narrow region of interest around the 76Ge neutrinoless double-beta decay peak.

double-beta decay↗

DESIGN OF A THERMOSIPHON FOR COOLING LOW-BACKGROUND HPGE ARRAYS

ABSTRACT A two-phase nitrogen thermosiphon was developed for the new generation of low-background high-purity germanium (HPGe) arrays. The cooling system for these arrays has to be able to handle the heat load (>20 W) presented by a large detector mass while meeting stringent requirements necessary for low-background systems. The HPGe detector modules should operate as close to liquid nitrogen temperature (<80K) as possible to provide adequate operating conditions for a full range of HPGe impurity concentrations. In addition, exceptional temperature stability (<1 K) is needed to reduce electronic gain shifts due to changes in the front-end electronics operating temperature. In order to meet the background requirements of state-of-the-art systems these arrays are enclosed in passive lead and copper shielding up to 1 m thick. In this paper we present a cooling system for low-background experiments that complies with these stringent geometrical restrictions. Active cooling was integrated via a horizontal thermosiphon that can be fabricated using ultra-pure electroformed copper. It was charged with nitrogen to 434 kPa (63 PSIA) at 292 K, which provided a fill ratio of 10%. The results showed that the thermosiphon can effectively remove in excess of 25 W of heat load.

low-background, thermal conductivity, radiation de↗

The MAJORANA DEMONSTRATOR: A Search for Neutrinoless Double-beta Decay of Germanium-76

The observation of neutrinoless double-beta decay would determine whether the neutrino is a Majorana particle and provide information on the absolute scale of neutrino mass. The MAJORANA Collaboration is constructing the DEMONSTRATOR, an array of germanium detectors, to search for neutrinoless double-beta decay of 76Ge. The DEMONSTRATOR will contain 40 kg of germanium; up to 30 kg will be enriched to 86% in 76Ge. The DEMONSTRATOR will be deployed deep underground in an ultra-low-background shielded environment. Operation of the DEMONSTRATOR aims to determine whether a future tonne-scale germanium experiment can achieve a background goal of one count per tonne-year in a 4-keV region of interest around the 76Ge neutrinoless double-beta decay Q-value of 2039 keV.

Schubert, Alexis G.↗

Majorana Demonstrator Bolted Joint Mechanical and Thermal Analysis

The MAJORANA DEMONSTRATOR is designed to probe for neutrinoless double-beta decay, an extremely rare process with a half-life in the order of 10 26 years. The experiment uses an ultra-low background, high-purity germanium detector array. The germanium crystals are both the source and the detector in this experiment. Operating these crystals as ionizing radiation detectors requires having them under cryogenic conditions (below 90 K). A liquid nitrogen thermosyphon is used to extract the heat from the detectors. The detector channels are arranged in strings and thermally coupled to the thermosyphon through a cold plate. The cold plate is joined to the thermosyphon by a bolted joint. This circular plate is housed inside the cryostat can. This document provides a detailed study of the bolted joint that connects the cold plate and the thermosyphon. An analysis of the mechanical and thermal properties of this bolted joint is presented. The force applied to the joint is derived from the torque applied to each one of the six bolts that form the joint. The thermal conductivity of the joint is measured as a function of applied force. The required heat conductivity for a successful experiment is the combination of the thermal conductivity of the detector string and this joint. The thermal behavior of the joint is experimentally implemented and analyzed in this study.

Aguayo Navarrete, Estanislao↗

First observations of B$0\atop{2}$ → J/ψη and B$0\atop{2}$ → J/ψη'

We report first observations of B$0\atop{2}$→J/ψη and B$0\atop{2}$→J/ψη'. The results are obtained from 121.4 fb -1 of data collected at the Υ(5S) resonance with the Belle detector at the KEKB e + e - collider. We obtain the branching fractions B(B$0\atop{2}$→J/ψη)=[5.10±0.50(stat)±0.25(syst)-0.79+1.14(N Bs(*)$\bar{B}$ s(*) )]×10 -4 , and B(B$0\atop{2}$→J/ψη')=[3.71±0.61(stat)±0.18(syst)-0.57+0.83(N Bs(*)$\bar{B}$ s(*) )]×10 -4 . The ratio of the two branching fractions is measured to be B(Bs→J/ψη')/B(Bs→J/ψη)=0.73±0.14(stat)±0.02(syst).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimization of the Transport Shield for Neutrinoless Double-beta Decay Enriched Germanium

This document presents results of an investigation of the material and geometry choice for the transport shield of germanium, the active detector material used in 76Ge neutrinoless double beta decay searches. The objective of this work is to select the optimal material and geometry to minimize cosmogenic production of radioactive isotopes in the germanium material. The design of such a shield is based on the calculation of the cosmogenic production rate of isotopes that are known to cause interfering backgrounds in 76Ge neutrinoless double beta decay searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for CP violation in D ± meson decays to Φπ±

We search for CP violation in Cabibbo-suppressed charged D meson decays by measuring the difference between the CP-violating asymmetries for the Cabibbo-suppressed decays D ± →K⁺ K⁻ π ± and the Cabibbo-favored decays D s ± → K⁺K⁻ π ± in the K⁺K⁻ mass region of the Φ resonance. Using 955 fb⁻¹ of data collected with the Belle detector, we obtain A CP D⁺ →Φπ⁺ = (+0.51±0.28±0.05)%. The measurement improves the sensitivity of previous searches by more than a factor of 5.We find no evidence for direct CP violation.

Environmental Molecular Sciences Laboratory↗

Observation of B - →$\bar{p}$ΛD 0 at Belle

We study B- meson decays to $\bar{p}$ΛD (*)0 final states using a sample of 657×10 6 B$\bar{B}$ events collected at the Υ(4S) resonance with the Belle detector at the KEKB asymmetric-energy e + e - collider. The observed branching fraction for B - →$\bar{p}$ΛD 0 is (1.43$+0.28\atop{-0.25}$±0.18)×10 -5 with a significance of 8.1 standard deviations, where the uncertainties are statistical and systematic, respectively. Most of the signal events have the $\bar{p}$ Λ mass peaking near threshold. No significant signal is observed for $\bar{p}$ΛD (*)0 and the corresponding upper limit on the branching fraction is 4.8×10 -5 at the 90% confidence level.

43 PARTICLE ACCELERATORS↗

First observation of radiative B⁰ → ΦK⁰γ decays and measurements of their time-dependent CP violation

We report the first observation of the radiative decay B⁰→ ΦK⁰γ using a data sample of 772 × 10⁶ BB¯ pairs collected at the (4S) resonance with the Belle detector at the KEKB asymmetric-energy e⁺e⁻ collider. We observe a signal of 37 ± 8 events with a significance of 5.4 standard deviations including systematic uncertainties. The measured branching fraction is B(B⁰→ ΦK⁰γ) = (2.74±0.60±0.32)×10⁻⁶, where the uncertainties are statistical and systematic, respectively. We also report the first measurements of time-dependent CP-violation parameters: S ΦK⁰ S γ = +0.74 ⁺0.72 –1.05 (stat) +0.10 –0.24 (syst) and A ΦK⁰ S γ = +0.35 ± 0.58(stat) +0.23 –0.10 (syst). Furthermore, we measure B(B⁺ → ΦK⁺γ) = (2.48 ± 0.30 ± 0.24) × 10⁻⁶, ACP = –0.03 ± 0.11 ± 0.08 and find that the signal is concentrated in the M ΦK mass region near threshold.

Sahoo, Himansu B.↗

Astroparticle physics with a customized low-background broad energy Germanium detector

The Majorana Collaboration is building the Majorana Demonstrator, a 60 kg array of high purity germanium detectors housed in an ultra-low background shield at the Sanford Underground Laboratory in Lead, SD. The Majorana Demonstrator will search for neutrinoless double-beta decay of 76Ge while demonstrating the feasibility of a tonne-scale experiment. It may also carry out a dark matter search in the 1-10 GeV/c² mass range. We have found that customized Broad Energy Germanium (BEGe) detectors produced by Canberra have several desirable features for a neutrinoless double-beta decay experiment, including low electronic noise, excellent pulse shape analysis capabilities, and simple fabrication. We have deployed a customized BEGe, the Majorana Low-Background BEGe at Kimballton (MALBEK), in a low-background cryostat and shield at the Kimballton Underground Research Facility in Virginia. This paper will focus on the detector characteristics and measurements that can be performed with such a radiation detector in a low-background environment.

dark matter↗