Spent Nuclear Fuel Measurements
Spent Nuclear Fuel Measurements deliverable for NA-22 project.
Engineering topics
Publications and source records attributed to Fast, James E..
Spent Nuclear Fuel Measurements deliverable for NA-22 project.
A longstanding challenge is the assay of spent nuclear fuel (SNF). Determining the isotopic content of SNF requires gamma-ray spectroscopy. PNNL has developed new digital filtering and analysis techniques to produce an ultra high-rate gamma-ray spectrometer from a standard coaxial high-purity germanium (HPGe) crystal. This ~40% efficient detector has been operated for SNF measurements at a throughput of about 400k gamma-ray counts per second (kcps) at an input rate of 1.3 Mcps. Optimized filtering algorithms preserve the spectroscopic capability of the system even at these high rates. This talk will present the results of a SNF measurement with aged SNF pellets at PNNL’s Radiochemical Processing Laboratory, first results with a FPGA front end processor capable of processing the data in real time, and the development path toward a multi-element system to assay fuel assemblies.
The MAJORANA DEMONSTRATOR will search for the neutrinoless double-beta (ββ(0ν)) decay of the isotope 76 Ge with a mixed array of enriched and natural germanium detectors. The observation of this rare decay would indicate that the neutrino is its own antiparticle, demonstrate that lepton number is not conserved, and provide information on the absolute mass scale of the neutrino. The DEMONSTRATOR is being assembled at the 4850-foot level of the Sanford Underground Research Facility in Lead, South Dakota. The array will be situated in a low-background environment and surrounded by passive and active shielding. Here we describe the science goals of the DEMONSTRATOR and the details of its design.
We search for CP violation in neutral charm meson decays using a data sample with an integrated luminosity of 966 fb –1 collected with the Belle detector at the KEKB e + e – asymmetric-energy collider. The asymmetry obtained in the rate of D 0 and D 0 ¯ decays to the π 0 π 0 final state, [–0.03±0.64(stat)±0.10(syst)]%, is consistent with no CP violation. This constitutes an order of magnitude improvement over the existing result. Here, we also present an updated measurement of the CP asymmetry in the D0→K$^{0}_{S}$π 0 decay: ACP(D 0 → K$^{0}_{S}$π 0 ) = [–0.21±0.16(stat)±0.07(syst)]%.
Measurements of Branching Fractions of τ Lepton Decays with one or more K^{0}_{S}
The Majorana Demonstrator will search for the neutrinoless double–beta decay (0vββ) of the 76 Ge isotope with a mixed array of enriched and natural germanium detectors. The observation of this rare decay would indicate the neutrino is its own anti–particle, demonstrate that lepton number is not conserved, and provide information on the absolute mass–scale of the neutrino. The Demonstrator is being assembled at the 4850 foot level of the Sanford Underground Research Facility in Lead, South Dakota. The array will be contained in a low–background environment and surrounded by passive and active shielding. The goals for the Demonstrator are: demonstrating a background rate less than 3 t -1 y -1 in the 4 keV region of interest (ROI) surrounding the 2039 keV 76 Ge endpoint energy; establishing the technology required to build a tonne–scale germanium based double–beta decay experiment; testing the recent claim of observation of 0vββ [1]; and performing a direct search for light WIMPs (3-10 GeV/c 2 ).
In this work, we observe D 0 - D ¯ 0 mixing in the decay D 0 → K + π - using a data sample of integrated luminosity 976 fb - 1 collected with the Belle detector at the KEKB e + e - asymmetric-energy collider. We measure the mixing parameters x ' 2 = ( 0.09 ± 0.22 ) × 1 0 - 3 and y ' = ( 4.6 ± 3.4 ) × 1 0 - 3 and the ratio of doubly Cabibbo-suppressed to Cabibbo-favored decay rates R D = ( 3.53 ± 0.13 ) × 1 0 - 3 , where the uncertainties are statistical and systematic combined. Our measurement excludes the no-mixing hypothesis at the 5.1 standard deviation level.
A Multi-Point Contact HPGe Detector to be submitted to a research journal.
We report that the lifetime of the τ lepton is measured using the process e + e - → τ + τ - , where both τ leptons decay to 3 π ν τ . The result for the mean lifetime, based on 711 fb - 1 of data collected with the Belle detector at the Y ( 4 S ) resonance and 60 MeV below, is τ = ( 290 . 17 ± 0.53 ( stat ) ± 0.33 ( syst ) ) × 10 - 15 s . The first measurement of the lifetime difference between τ + and τ - is performed. The upper limit on the relative lifetime difference between positive and negative τ leptons is | Δ τ | / τ < 7.0 × 10 - 3 at 90% C.L.
The gamma-ray spectrum of spent nuclear fuel in the 3- to 6-MeV energy range is important for active interrogation since emitted gamma rays emitted from nuclear decay are not expected to interfere with measurements in this energy region. There is, unfortunately, a dearth of empirical measurements from spent nuclear fuel in this region. This work is an initial attempt to partially ll this gap by presenting an analysis of gamma-ray spectra collected from a set of spent nuclear fuel sources using a high-purity germanium detector array. This multi-crystal array possesses a large collection volume, providing high energy resolution up to 16 MeV. The results of these measurements establish the continuum count-rate in the energy region between 3- and 6-MeV. Also assessed is the potential for peaks from passive emissions to interfere with peak measurements resulting from active interrogation delayed emissions. As one of the first documented empirical measurements of passive emissions from spent fuel for energies above 3 MeV, this work provides a foundation for active interrogation model validation and detector development.
This report describes the final performance achieved with the detector system developed for the Ultra High Rate Germanium (UHRGe) project. The system performance has been evaluated at low, moderate and high rates and includes the performance of real-time analysis algorithms running in the FPGA of the data acquisition system. This performance is compared to that of offline analyses of streaming waveform data collected with the same data acquisition system the performance of a commercial Multi-Channel Analyzer designed for high-resolution spectroscopy applications, the Canberra LYNX.
Using 121.4 fb -1 of data collected with the Belle detector at the Υ(5S) resonance at the KEKB asymmetric-energy e + e - collider, we report evidence for the $\bar{B}$ 0 s → Λ$+\atop{c}$$\bar{Λ}$π - source decay mode with a measured branching fraction (3.6±1.1[stat] $+0.3\atop{-0.5}$± 0.9 [Λ$+\atop{c}$] ±0.7[N $\bar{B}$ 0 s ]) x 10 -4 and a significance of 4.4 standard deviations. This is the first evidence for a baryonic $\bar{B}$ 0 s decay.
We present measurements of absolute branching fractions of hadronic and lep-tonic \( D_s^{+} \) decays to K - K + π + , \( {{\overline{K}}^0} \) K + , ηπ + , μ + ν μ and τ + ν τ and report a search for the leptonic \( D_s^{+} \) → e + ν e decays. The results are obtained from a data sample of 913 fb -1 collected at or near the \( \varUpsilon \) (4 S ) and \( \varUpsilon \) (5 S ) resonances with the Belle detector at the KEKB asymmetric-energy e + e - collider. The branching fractions of hadronic decays are measured to be $$ \begin{array}{*{20}{c}} {\mathcal{B}\left( {D_s^{+}\ \to\ {K^{-}}{K^{+}}{\pi^{+}}} \right) = \left( {5.06\pm 0.15\pm 0.21} \right)\%,} \\ {\mathcal{B}\left( {D_s^{+}\ \to\ {{\overline{K}}^0}{K^{+}}} \right) = \left( {2.95\pm 0.11\pm 0.09} \right)\%,} \\ {\mathcal{B}\left( {D_s^{+}\ \to\ \eta {\pi^{+}}} \right) = \left( {1.82\pm 0.14\pm 0.07} \right)\%,} \\ \end{array} $$ where the first and second uncertainties are statistical and systematic, respectively. The branching fractions of leptonic decays are measured to be $$ \begin{array}{*{20}{c}} {\mathcal{B}\left( {D_s^{+}\ \to\ {\mu^{+}}{\nu_{\mu }}} \right)=\left( {0.531\pm 0.028\pm 0.020} \right)\%,} \\ {\mathcal{B}\left( {D_s^{+}\to {\tau^{+}}{\nu_{\tau }}} \right)=\left( {5.70\pm 0.21_{-0.30}^{-0.31 }} \right)\%,} \\ \end{array} $$ which are combined to determine the \( D_s^{+} \) meson decay constant $$ {f_{{{D_s}}}}=\left( {255.5\pm 4.2\pm 5.1} \right)\ \mathrm{MeV}. $$ We find no significant signal for \( D_s^{+} \) → e + ν e decays and set an upper limit of \( \mathcal{B}\left( {D_s^{+}\ \to\ {e^{+}}{\nu_e}} \right) \) < 1 . 0(0 . 83) × 10 -4 at 95% (90%) confidence level.
We search for bottomonium states in $\Upsilon(2S)$ → ($\bar{bb}$) gamma decays with an integrated luminosity of 24.7fb -1 recorded at the $\Upsilon(2S)$ resonance with the Belle detector at KEK, containing (157.8 ± 3.6) X 10 6 $\Upsilon(2S)$ events. The ($\bar{bb}$) system is reconstructed in 26 exclusive hadronic final states composed of charged pions, kaons, protons, and $K^0_S$ mesons. We find no evidence for the state recently observed around 9975 MeV ($X_{\bar{bb}}$) in an analysis based on a data sample of 9.3 X 10 6 $\Upsilon(2S)$ events collected with the CLEO III detector. We set a 90 % confidence-level upper limit on the branching fraction $Β$[$\Upsilon(2S)$ → $X_{\bar{bb}\gamma}$] X $\sum_i$ $B$[$X_{\bar{bb}}$ → $h_i$] $<$ 4.9 X 10 -6 , summed over the exclusive hadronic final states employed in our analysis. This result is an order of magnitude smaller than the measurement reported with CLEO data. We also set an upper limit for the $\eta_b(1S)$ state of $B$[$\Upsilon(2S)$ → $\eta_b(1S)\gamma$] X $\sum_i$B[$\eta_b(1S)$ → $h_i$] $<$ 3.7 X 10 -6 .
CoGeNT employs p-type point-contact (PPC) germanium detectors to search for Weakly In- teracting Massive Particles (WIMPs). By virtue of its low energy threshold and ability to reject surface backgrounds, this type of device allows an emphasis on low-mass dark matter candidates (m* * 10 GeV/c2). We report on the characteristics of the PPC detector presently taking data at the Soudan Underground Laboratory, elaborating on aspects of shielding, data acquisition, instru- mental stability, data analysis, and background estimation. A detailed background model is used to investigate the low energy excess of events previously reported, and to assess the possibility of temporal modulations in the low-energy event rate. We conclude that the technique is ideally suited to search for the annual modulation signature expected from dark matter particle interactions in the region of WIMP mass and coupling favored by the DAMA/LIBRA claim.
The cross section for $e^+e^-→π^+π^-J/ψ$ between 3.8 GeV and 5.5 GeV is measured with a 967 fb -1 data sample collected by the Belle detector at or near the $\Upsilon(nS)$ ($n=1, 2, ..., 5$) resonances. The $\Upsilon$(4260) state is observed, and its resonance parameters are determined. In addition, an excess of $π^+π^-J/ψ$ production around 4 GeV is observed. This feature can be described by a Breit-Wigner parameterization with properties that are consistent with the $\Upsilon$(4008) state that was previously reported by Belle. In a study of $\Upsilon$(4260)→$π^+π^-J/ψ$ decays, a structure is observed in the $M(\pi^{\pm}J/ψ)$ mass spectrum with 5.2$σ$ significance, with mass M=(3894.5±6.6±4.5)MeV/$c^2$ and width $Γ$=(63±24±26) MeV/$c^2$, where the errors are statistical and systematic, respectively. This structure can be interpreted as a new charged charmonium-like state.
The Majorana collaboration is actively pursuing research and development aimed at a tonne-scale 76Ge neutrinoless double-beta decay experiment, an R&D effort that will field approximately 40 kg of germanium detectors with mixed enrichment levels. This article provides a status update on the construction of the Demonstrator
The MAJORANA DEMONSTRATOR (MJD) is an ultra-low background neutrinoless double-beta decay (0νββ) experiment that will deploy up to 40 kg of high purity germanium detectors (HPGe). The goal of this experiment is to demonstrate the feasibility of building a detector array with less than 1 event/ton-year in a 4 keV region of interest around the 0νββ signal. HPGe diodes, when used as ionizing radiation detectors, need to be maintained at a temperature close to that of liquid nitrogen (77 K). This work describes the R&D results of a cryogenic system capable of meeting the requirements of low background and the cooling capacity required to successfully operate such a detector system. The MJD germanium detector modules will operate at liquid nitrogen temperature to provide adequate cooling for a full range of HPGe impurity concentrations. This paper shows the experimental results obtained using a two-phase horizontal thermosyphon using liquid nitrogen as the MJD’s cooling system. The cold test shows that the proposed thermosyphon has sufficient cooling power to handle the heat load of an MJD module. Results for the temperature gradient across the thermosyphon, cooling capacity, and design considerations demonstrate that the thermosyphon can effectively remove the calculated heat load of each module of the experiment. The thermosyphon will be bolted to a cold plate from which detector strings will hang. The thermal conductivity of a mockup of the MJD bolted thermal joint is experimentally determined to be below 0.1 K/W.