Engineering Papers⌕ Search

Engineering topics

Elen, Muthu (ORCID:0000000261927091)

Publications and source records attributed to Elen, Muthu (ORCID:0000000261927091).

Dielectric Spectroscopy Cable NDE for Unequal Aging Over Different Lengths

This Pacific Northwest National Laboratory milestone report assesses the effect of unequal aging over different lengths of cable on dielectric spectroscopy (DS) bulk impedance measurements from the cable end. DS measurements can indicate the remaining useful life of cables; however, most benchmark tests are based on accelerated aging of the entire cable. If only a portion of the cable is exposed to a harsh environment (as is frequently the case), the DS measurement will indicate a significantly less-aged cable than if the entire cable were exposed to a uniform environmental stress. The DS measurement is primarily related to the intrinsic insulation material relative permittivity—typically between 1.5 and 3.0. Insulation aging increases permittivity and, correspondingly, the cable’s overall capacitance measured from the cable end. To judge the health of the overall cable system, operators are primarily interested in the condition of the most severely aged section since that is where a failure is most likely to occur. This can be expressed as the dimensionless relative permittivity of the severely aged section divided by the permittivity of a pristine cable. This relative permittivity is an intrinsic material parameter independent of cable length and can serve as a quantitative indication of the insulation condition. If the relative percentages of cable exposed to a harsh and benign environment are known, the DS measurement of the entire cable length, including both pristine and aged sections, can be compensated to predict the relative permittivity (relative to pristine permittivity) of the most severly aged segment. A test was performed on three 50 ft (16 m) cables with 10%, 50%, and 90% of the cable inside a thermal aging oven. Predictably, the aging effect on the DS response was greatest in the 90% sample, followed by the 50% sample, and then the 10% sample. The more interesting result is the ratio of the aged insulation permittivity to the pristine insulation permittivity. Based on prior work, an end-of-life cable has a value of approximately 1.35. If the relative percentages of pristine and severely aged cable lengths are known, and the total cable-length capacitance of the initial pristine cable and the combined pristine plus aged cable are known, the relative aged permittivity (ratio of aged section permittivity / pristine section permittivity) can be estimated. The relative cable lengths exposed to a harsh environment may be known or estimated based on plant layout drawings or cable reflectometry tests that can locate the oven entry and exit points. The compensation was verified using a lumped-parameter model to predict the aged-segment permittivity e2/e1, where e2 is the aged-segment permittivity and e1 is the pristine-segment permittivity. For all three percentages of aged cable lengths, the ratio was quite similar, as would be expected since all cable segments were exposed to the same aging environment. This ratio of aged permittivity to pristine permittivity can be compared to other damage indicating tests, including elongation at break, to assess cable condition.

ARENA Test Bed↗

Experimental Comparison of Elastomeric Materials for Hydraulic Seal Durability under Reciprocating Conditions

Wave Energy Converters (WECs) rely on hydraulic Power Take-Off (PTO) systems to transform the kinetic energy of ocean waves into electricity, where hydraulic seals play a critical role in preventing fluid leakage and ensuring watertight operation under harsh marine conditions. However, seal degradation due to wear, fatigue, and corrosion remains a key challenge limiting system reliability and increasing maintenance costs. In this study, the tribological performance of elastomeric materials for hydraulic sealing applications that are based on commercial polyurethane and custom-compounded Ethylene Propylene Diene Monomer (EPDM) is investigated. Using a CSM tribometer, reciprocating wear tests were conducted in accordance with ASTM G133 under dry sliding conditions, with normal loads ranging from 3 to 10 N, and sliding speeds of 10 to 30 mm/s. Coefficient of friction (COF), specific wear rate, and worn surface morphology are evaluated to understand how load, velocity, and material composition affect seal durability. Improved wear stability and high Shore A hardness (93–94) were demonstrated by the commercial thermoplastic polyurethane (Duralast 4203 and 4758). EPDM-based compounds showed different filler-dependent behaviors, formulations filled with carbon black (E3) had the lowest wear rate (1.45 × 10?4 mm³ N?¹ m?¹) and increased load-bearing capacity, while samples modified with silica and plasticizer (E4, E5) had better conformability and damping but less hardness. Compounded EPDMs showed wider deformation zones because of their lower modulus and filler-matrix interfacial fluctuations, while commercial grades exhibited shallower wear scars (= 380 µm), according to optical profilometry. The Archard model-based lifetime estimation showed that, under 10 N and 30 mm/s, operational endurance ranged from 3.1 to 6.2 years. Because of its low wear rate and steady interfacial behavior, E3 had the longest anticipated life. For medium-load hydraulic sealing applications, these results demonstrate the possibility of customized EPDM formulations as affordable substitutes for commercial polyurethanes. They also offer a quantitative foundation for material selection and lifespan prediction.

Durability↗