Engineering PapersSearch

Engineering topics

Durand, D. [Caen U.]

Publications and source records attributed to Durand, D. [Caen U.].

Electromagnetic energy calibration of the SoLid detector with horizontal muons

SoLid is a neutrino experiment at very-short baselinesearching for active-to-sterile oscillations of reactorantineutrinos. The detection principle is based on the pairing oftwo types of solid scintillators: polyvinyl toluene and $^{6}$Li:ZnS(Ag), which is a new technology used in this field ofPhysics. In addition to good neutron-gamma discrimination, thissetup allows the detector to be highly segmented; the basicdetection unit is a 5 cm cube. High segmentation provides numerousadvantages including precise localisation of the Inverse Beta Decay(IBD) products, the derivation of an antineutrino energy estimatorbased on the isolated positron energy, and a powerful backgroundreduction tool that relies on the topological signature of thesignal. Finally, the system is read out by a network ofwavelength-shifting fibres coupled to photosensors. A relativeelectromagnetic calibration is performed with horizontal cosmicmuons. This source poses the simplest calibration problem in which asingle detection unit is involved. In addition, large muon energydeposits allow us to perform a calibration at the most detailedlevel (i.e. per fibre) and to accurately define the fraction ofenergy escaping to neighbouring detection cells. A statisticalprecision at the sub-percent level is reached. The paper alsodiscusses two methods to calibrate the absolute energy scale andpresents their implementation and results. The first method relieson horizontal muons, though the precision is limited to around 10%because of the uncertainty in the energy distribution of suchmuons. A novel, alternative method based on the radioactiveamericium-beryllium source is proposed. It takes advantage of theelectron-positron pair-production process and provides a calibrationpoint at 3.4 MeV (i.e. in the core of the IBD positronspectrum). The paper is concluded with various cross-check includinga determination of the energy spectrum of the standard cosmogenicbackground candle: $^{12}$B.

Abreu, Y. [Antwerp U.]

Search for very-short-baseline oscillations of reactor antineutrinos with the SoLid detector

In this paper we report the first scientific result based on antineutrinos emitted from the BR2 reactor at SCK CEN. The SoLid experiment uses a novel type of highly granular detector whose basic detection unit combines two scintillators, polyvinyl toluene (PVT) and Li 6 F : ZnS ( Ag ) , to measure antineutrinos via their inverse- β -decay products. An advantage of PVT is its highly linear response as a function of deposited particle energy. The full-scale detector comprises 12 800 voxels and operates over a very short 6.3–8.9 m baseline from the reactor core. The detector segmentation and its three-dimensional imaging capabilities facilitate the extraction of the positron energy from the rest of the visible energy, allowing the latter to be utilized for signal-background discrimination. We present a result obtained from 280 reactor-on days (55 MW mean power) and 172 reactor-off days, respectively, of live data taking. A total of 29 479 ± 603 (stat) antineutrino candidates have been selected, corresponding to an average rate of 105 events per day and a signal-to-background ratio of 0.27. A search for disappearance of antineutrinos to a sterile state has been conducted using complementary model-dependent frequentist and Bayesian fits, providing constraints on the allowed region of the reactor antineutrino anomaly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS