Improved Linear Ion Trap
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Dick, G. J..
Explore the source record for details and available documents.
We describe a spectroscopic measurement of the temperature and linear density of HG+ ions held in a linear ion trap (LIT). The inferred temperature and number result from analysis of sidebands on the 40.5 GHz resonance line.
A high-performance frequency standard based on (199)Hg(+) ions confined in a hybrid radio frequency (RF)/dc linear ion trap is demonstrated. This trap permits storage of large numbers of ions with reduced susceptibility to the second-order Doppler effect caused by the RF confining fields. A 160-mHz-wide atomic resonance line for the 40.5-GHz clock transition is used to steer the output of a 5-mHz crystal oscillator to obtain a stability of 2 x 10(exp -15) for 24,000-second averaging times. Measurements with a 37-mHz line width for the Hg(+) clock transition demonstrate that the inherent stability for this frequency standard is better than 1 x 10(exp -15) at 10,000-second averaging times.
We report the development of a fieldable frequency standard based on Hg-199(+) ions confined in a hybrid r.f./dc linear ion trap. This trap permits storage of large numbers of ions with reduced susceptibility to the second-order Doppler effect caused by the r.f. confining fields. A 160 mHz wide atomic resonance line for the 40.5 GHz clock transition is used to steer the output of a 5 MHz crystal oscillator to obtain a stability of 2 x 10 exp -15 for 24,000 s averaging times. For longer averaging intervals, measurements are limited by instabilities in available hydrogen maser frequency standards. Measurements with 37 mHz linewidth for the Hg(+) clock transition demonstrate that the inherent stability for this frequency standard is at least as good as 1 x 10 exp -15.
A new frequency standard was demonstrated with the aid of a double phase locked loop (PLL) receiver. A superconducting cavity maser oscillator (SCMO) and a hydrogen maser are combined to show the medium term performance of the hydrogen maser together with improved short term performance made possible by the SCMO. The receiver, which generates a 100 MHz signal with reduced noise, is phase locked to (and may be used in place of) the 100 MHz hydrogen maser output. The maser signal, 2.69xxx-GHz SCMO output, and a 100 MHz quartz crystal oscillator are optimally combined by the receiver. A measured two source fractional frequency stability of 2 x 10(exp -14) was obtained for a measuring time of r = 1 sec, and 1 x 10(exp -15) at r = 1,000 sec. The 1 sec value is approx. 10 times lower than that for hydrogen masers, while the 1,000 sec value is identical to hydrogen maser performance. The design is based on phase noise models for the hydrogen maser, the SCMO, and quartz crystal oscillators for offset frequencies down to 1 x 10(exp -6) Hz.
In order to develop a trapped ion-based fieldable frequency standard with stability 1 x 10 to the -13th/sq rt tau for averaging times tau greater than 10,000 s, a hybrid RF/DC linear ion trap was developed which permits storage of large numbers of ions with reduced susceptibility to the second-order Doppler effect caused by the RF confining fields. The authors have confined Hg-199(+) ions in this trap and have measured very high Q transitions with good SNRs. In preliminary measurements they obtained stabilities of 1.6 x 10 to the -13th/sq rt tau (tau between 50 and 800 s) with a 160-mHz wide atomic resonance linewidth and a signal-to-noise ratio of 40 for each measurement cycle. Atomic resonance lines as narrow as 30 mHz on the 40.5-GHz clock transition have been measured with no appreciable reduction in the ion signal. A stability of 7 x 10 to the -14th/sq rt tau is made possible by the signal-to-noise and line Q of this measured transition. Analysis of fundamental sources of frequency instability indicates that a long-term stability of 2 x 10 to the -16th is feasible for this device with existing technology for tau = 10 to the 6th s or more.
Recent measurements on the superconducting cavity maser (SCM) oscillator show frequency stability of parts in 10 exp 15 for times from 1 to 1000 sec. Phase noise of approximately -80 dB/f-cubed was also measured. This short- and mid-term performance is believed to be better than that of any known microwave oscillator. In particular, stability at a measuring time of 1 sec is 10 times better than that of a hydrogen maser, and phase noise at 8 GHz is more than 20 dB below that of the best multiplied quartz crystal oscillators. Substantial technical improvements have been made to eliminate frequency instability due to operational parameters. They are temperature, pump frequency, pump power, pump frequency polarization, temperature gradient, coupling strength, and output VSWR. Either the parameter was stabilized or the coefficient which couples the parameter to the operating frequency was minimized. A frequency pulling coil has been implemented and tested to enable the SCM to be slaved to a hydrogen maser with a time constant of approximately 50 sec. This combination would allow the excellent long term performance of the hydrogen maser to be improved by the newly available short term performance of the SCM.
The development by NASA JPL of high-temperature superconductors (HTSs) for use in microwave circuit elements is discussed. The synthesis of HTS films and characterization of their microwave absorption are reviewed. Applications to cryogenic low-noise receivers, spacecraft microwave systems, and low-noise oscillators are considered.
Oscillator configurations which reduce the effect of 1/f noise sources for both direct feedback and stabilized local oscillator (STALO) circuits are developed and analyzed. By appropriate use of carrier suppression, a small signal is generated which suffers no loss of loop phase information or signal-to-noise ratio. This small signal can be amplified without degradation by multiplicative amplifier noise, and can be detected without saturation of the detector. Together with recent advances in microwave resonator Qs, these circuit improvements will make possible lower phase noise than can be presently achieved without the use of cryogenic devices.
A novel linear ion trap was designed, which permits storage of a large number of ions with reduced susceptibility to the second-order Doppler effect caused by the RF confining fields. This new trap should store about 20 times the number of ions as a conventional RF trap with no corresponding increase in second-order Doppler shift from the confining field. In addition, the sensitivity of this shift to trapping parameters, i.e., RF voltage, RF frequency, and trap size, is greatly reduced.
A novel linear ion trap that permits storage of a large number of ions with reduced susceptibility to the second-order Doppler effect caused by the radio frequency (RF) confining fields has been designed and built. This new trap should store about 20 times the number of ions a conventional RF trap stores with no corresponding increase in second-order Doppler shift from the confining field. In addition, the sensitivity of this shift to trapping parameters, i.e., RF voltage, RF frequency, and trap size, is greatly reduced.
Tests of the superconducting cavity maser (SCM) ultra-stable frequency source have been made for the first time using a hydrogen maser for a frequency reference. In addition to characterizing the frequency stability, the sensitivity of the output frequency to several crucial parameters was determined for various operating conditions. Based on this determination, the refrigeration and thermal control systems of the SCM were modified. Subsequent tests showed substantially improved performance, especially at the longest averaging times.
In order to provide frequency standards for the Deep Space Network (DSN) which are more stable than present-day hydrogen masers, a research task was established under the Advanced Systems Program of the TDA to develop a Hg-199(+) trapped ion frequency standard. The first closed-loop operation of this kind is described. Mercury-199 ions are confined in an RF trap and are state-selected through the use of optical pumping with 194 nm UV light from a Hg-202 discharge lamp. Absorption of microwave radiation at the hyperfine frequency (40.5 GHz) is signaled by atomic fluorescence of the UV light. The frequency of a 40.5 GHz oscillator is locked to a 1.6 Hz wide atomic absorption line of the trapped ions. The measured Allan variance of this locked oscillator is currently gamma sub y (pi) = 4.4 x 10 to the minus 12th/square root of pi for 20 is less than pi is less than 320 seconds, which is better stability than the best commercial cesium standards by almost a factor of 2. This initial result was achieved without magnetic shielding and without regulation of ion number.
The general features of the Hg-199(+) trapped-ion frequency standard are outlined and compared to other atomic frequency standards, especially the hydrogen maser. The points discussed are those which make the trapped Hg-199(+) standard attractive: high line Q, reduced sensitivity to external magnetic fields, and simplicity of state selection, among others.
Presented are the experimental and computational results of a study on a new kind of dielectric resonator oscillator (DRO). It consists of a cooled, cylindrically symmetric sapphire resonator surrounded by a metallic shield and is capable of higher Q's than any other dielectric resonator. Isolation of fields to the sapphire by the special nature of the electromagnetic mode allows the very low loss of the sapphire itself to be expressed. Calculations show that the plethora of modes in such resonators can be effectively reduced through the use of a ring resonator with appropriate dimensions. Experimental results show Q's ranging from 3 x 10 to the 8th at 77 K to 10 to the 9th at 4.2 K. Performance is estimated for several types of DROs incorporating these resonators. Phase noise reductions in X-band sources are indicated at values substantially lower than those previously available.
A new fast autotuner for the hydrogen maser was implemented. By modulating the cavity, a phase shift in the maser output signal is induced which is proportional to the cavity tuning error. The phase shift is detected and fed back to a varactor tuner to stabilize the cavity against long-term drifts. Also, a PIN-diode cavity modulator which gives no incidental frequency shift over a very wide range of operation was developed. Modulated at over 200 Hz, it allows variations in maser cavity frequency to be compensated with a loop gain greater than 1000. Compensation of incidental amplitude modulation of the output was demonstrated.
Cavity-modulation tuning system maintains resonance of hydrogen-maser cavity automatically, stabilizing maser frequency, without introducing undesirable frequency modulation. System tunes maser cavity rapidly by modulating one of physical characteristics of cavity affecting resonant frequency. Frequency-controlling components of tuning system placed at maser cavity, within maser vacuum. Thermal environment well controlled, and device insensitive to driving signal. Features contribute to stability of maser frequency.
A cavity consisting of a superconducting lead film on a sapphire substrate has been fabricated to obtain the enhanced frequency stability possible with this configuration. The cavity exhibits a quality value Q exceeding 2 x 10 to the 9th in its TE011 mode with a resonant frequency of 2.689 GHz. Methods of fabrication and testing of the cavity are presented. Since the interface between the film and substrate is exposed ot the full value of the resonant magnetic field, the present experiment is the most sensitive test to date for enhanced losses at the interface itself. No evidence of such losses is used. In fact, the measured values of the surface resistance match very well predictions for RF losses based on the BCS theory.