Engineering topics
Dick, G. J.
Publications and source records attributed to Dick, G. J..
Progress Report for a New Cryogenic Sapphire Oscillator
We present design progress and subsystem test results for a new short-term frequency standard, the Voltage Controlled Sapphire Oscillator (VCSO). Included are sapphire resonator and coupling design, cryocooler environmental sensitivity tests, Q measurement results, and turnover temperature results. A previous report presented history of the design related to resonator frequency and frequency compensation [1]. Performance goals are a frequency stability of 1x10(exp -14) (1 second less than or equal to (tau) less than or equal to 100 seconds) and two years or more continuous operation. Long-term operation and small size are facilitated by use of a small Stirling cryo-cooler (160W wall power) with an expected 5 year life.
A high performance frequency standard and distribution system for Cassini Ka-band experiment
This paper provides an overview and update of a specialized frequency reference system for the NASA Deep Space Network (DSN) to support Ka-band radio science experiments with the Cassini spacecraft, currently orbiting Saturn. Three major components, a Hydrogen Maser, Stabilized Fiber-optic Distribution Assembly (SFODA), and 10 Kelvin Cryocooled Sapphire Oscillator (10K CSO) and frequency-lock-loop, are integrated to achieve the very high performance, ground based frequency reference at a remote antenna site located 16 km from the hydrogen maser. Typical measured Allan Deviation is 1.6 -14 1 0a't 1 second and 1.7 x 10 -15 at 1000 seconds averaging intervals. Recently two 10K CSOs have been compared in situ while operating at the remote DSN site DSS-25. The CSO references were used operationally to downconvert the Ka band downlink received from the Cassini spacecraft in a series of occultation measurements performed over a 78 day period from March to June 2005.
Update on the low temperature microgravity physics facility
Explore the source record for details and available documents.
High stability 40 Kelvin cryo-cooled sapphire oscillator
Explore the source record for details and available documents.
Design for the microwave interrogation structure in PARCS
Explore the source record for details and available documents.
High stability 40 Kelvin cryo-cooled sapphire oscillator
We present initial test results for a new short-term frequency standard, the 40K Compensated Sapphire Oscillator (40K CSO).
The low temperature microgravity physics facility: progress and status
JPL is developing the Low Temperature Microgravity Physics Facility. The LTMPF is a multiple user and multiple flight facility that will provide a long duration low temperature environment for performing state of the art experiments at the International Space Station.
Design concept for microwave interrogation structure in PARCS
Explore the source record for details and available documents.
Design concept for microwave interrogation structure in PARCS
Explore the source record for details and available documents.
Design concept for the microwave interrogation structure in PARCS
In this paper we will describe key aspects of the conceptual design of the microwave interrogation structure in the laser-cooled cesium frequency standard that is part of the Primary Atomic Reference Clock in Space (PARCS) experiment.
The science capability of the Low Temperature Microgravity Physics Facility
The Low Temperature Microgravity Physics Facility (LTMPF) is a multiple user and multiple-flight NASA facility that will provide a low temperature environment for about 4. 5 months on board the International Space Station (ISS).
The science capability of the Low Temperature Microgravity Physics Facility
Explore the source record for details and available documents.
Cryo-cooled sapphire oscillator with mechanical compensation
We present test results for a short-term frequency standard, 40K Compensated Sapphire Oscillator (CSO).
The capabilities of the low temperature microgravity physics facility for performing science
Explore the source record for details and available documents.
The capabilitiesof the low temperature microgravity physics facility for performance science
Explore the source record for details and available documents.
Stabilized reference frequency distribution for radio science with the Cassini spacecraft and the Deep Space Network
This paper provides an overview and update of the end to end high performance frequency and timing subsystm.
Recent developments in cryogenic compensated sapphire oscillations
Cryogenic microwave oscillators offer the highest short term stability of any frequency sources.