Engineering Papers⌕ Search

Engineering topics

Davies, A.

Publications and source records attributed to Davies, A..

At least 19 records

Third international challenge to model the medium- to long-range transport of radioxenon to four Comprehensive Nuclear-Test-Ban Treaty monitoring stations

In 2015 and 2016, atmospheric transport modeling challenges were conducted in the context of the Comprehensive Nuclear-Test-Ban Treaty (CTBT) verification, however, with a more limited scope with respect to emission inventories, simulation period and number of relevant samples (i.e., those above the Minimum Detectable Concentration (MDC)) involved. Therefore, a more comprehensive atmospheric transport modeling challenge was organized in 2019. Stack release data of Xe-133 were provided by the Institut National des Radioéléments/IRE (Belgium) and the Canadian Nuclear Laboratories/CNL (Canada) and accounted for in the simulations over a three (mandatory) or six (optional) months period. Best estimate emissions of additional facilities (radiopharmaceutical production and nuclear research facilities, commercial reactors or relevant research reactors) of the Northern Hemisphere were included as well. Model results were compared with observed atmospheric activity concentrations at four International Monitoring System (IMS) stations located in Europe and North America with overall considerable influence of IRE and/or CNL emissions for evaluation of the participants’ runs. Participants were prompted to work with controlled and harmonized model set-ups to make runs more comparable, but also to increase diversity. It was found that using the stack emissions of IRE and CNL with daily resolution does not lead to better results than disaggregating annual emissions of these two facilities taken from the literature if an overall score for all stations covering all valid observed samples is considered. A moderate benefit of roughly 10% is visible in statistical scores for samples influenced by IRE and/or CNL to at least 50% and there can be considerable benefit for individual samples. Effects of transport errors, not properly characterized remaining emitters and long IMS sampling times (12–24 h) undoubtedly are in contrast to and reduce the benefit of high-quality IRE and CNL stack data. Complementary best estimates for remaining emitters push the scores up by 18% compared to just considering IRE and CNL emissions alone. Despite the efforts undertaken the full multi-model ensemble built is highly redundant. An ensemble based on a few arbitrary runs is sufficient to model the Xe-133 background at the stations investigated. The effective ensemble size is below five. An optimized ensemble at each station has on average slightly higher skill compared to the full ensemble. However, the improvement (maximum of 20% and minimum of 3% in RMSE) in skill is likely being too small for being exploited for an independent period.

54 ENVIRONMENTAL SCIENCES↗

Hot Raman amplification

A parameter regime is identified for Raman amplification at high temperatures, where deleterious laser–plasma instabilities that limit current amplification experiments are avoided, yet sufficient gain for an effective power amplifier is attained. Furthermore, calculations and kinetic simulations show that even at high temperatures, an amplifier is able to satisfy the criteria set forth to present a proof-of-principle system scalable to high powers, where energy transfer efficiencies are ≥30%, intensity gains are ≥10, and output intensities are ≥100× the pump intensity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

InterCarb: A Community Effort to Improve Interlaboratory Standardization of the Carbonate Clumped Isotope Thermometer Using Carbonate Standards

Abstract Increased use and improved methodology of carbonate clumped isotope thermometry has greatly enhanced our ability to interrogate a suite of Earth‐system processes. However, interlaboratory discrepancies in quantifying carbonate clumped isotope (Δ 47 ) measurements persist, and their specific sources remain unclear. To address interlaboratory differences, we first provide consensus values from the clumped isotope community for four carbonate standards relative to heated and equilibrated gases with 1,819 individual analyses from 10 laboratories. Then we analyzed the four carbonate standards along with three additional standards, spanning a broad range of δ 47 and Δ 47 values, for a total of 5,329 analyses on 25 individual mass spectrometers from 22 different laboratories. Treating three of the materials as known standards and the other four as unknowns, we find that the use of carbonate reference materials is a robust method for standardization that yields interlaboratory discrepancies entirely consistent with intralaboratory analytical uncertainties. Carbonate reference materials, along with measurement and data processing practices described herein, provide the carbonate clumped isotope community with a robust approach to achieve interlaboratory agreement as we continue to use and improve this powerful geochemical tool. We propose that carbonate clumped isotope data normalized to the carbonate reference materials described in this publication should be reported as Δ 47 (I‐CDES) values for Intercarb‐Carbon Dioxide Equilibrium Scale.

58 GEOSCIENCES↗

Flying focus: Spatial and temporal control of intensity for laser-based applications

An advanced focusing scheme, called a "flying focus," uses a chromatic focusing system combined with a broadband laser pulse with its colors arranged in time to propagate a high intensity focus over a distance that can be much greater than its Rayleigh length, while decoupling the speed at which the peak intensity propagates from its group velocity. The flying focus generates a short effective pulse duration with a small diameter focal spot that co- or counter-propagates along the optical axis at any velocity. Experiments validating the concept measured subluminal (–0.09c) to superluminal (39c) focal spot velocities with a nearly constant peak intensity over 4.5 mm. Experiments that increased the peak intensity above the ionization threshold for gas demonstrated ionization waves propagating at the velocity of the flying focus. Here these ionization waves of any velocity overcome several laser-plasma propagation issues, including ionization-induced refraction. The flying focus presents opportunities to overcome current fundamental limitations in laser-plasma amplifilers, laser wakefield accelerators, photon accelerators, and high-order frequency conversion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Flying focus and its application to plasma-based laser amplifiers

Combining a chirped laser pulse with a chromatic lens yields a flying focus—a laser focus that moves dynamically in time. This provides control over the propagation of the peak laser intensity within an extended focal region that can be many times larger than the system’s Rayleigh length. Any velocity is achievable, including backward relative to the laser propagation direction. Previous simulation results have shown that a laser beam with a flying focus can create a counter-propagating ionization wave and subsequently pump a frequency-downshifted laser via the stimulated Raman scattering instability. Compared to a conventional Raman amplification scheme, several advantages were highlighted, including improved temperature control, plasma uniformity, and precursor growth mitigation. Here, we extend those results to demonstrate additional benefits: (1) the flying focus makes it possible for an unseeded Raman amplifier to produce a short, high-intensity beam; and (2) the flying focus minimizes collisional absorption of the pump, facilitating amplifier operation at higher plasma densities. Preliminary experiments have laid the groundwork for a high-performance plasma-based laser amplifier. The focal spot dynamics were initially confirmed at low intensity. It was subsequently demonstrated that ionization waves of arbitrary velocity can be produced at higher intensity. Here, we show a counter-propagating ionization front moving at approximately the speed of light—the optimal result for a Raman amplifier.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Raman Amplification with a Flying Focus

Here, we propose a new laser amplifier scheme utilizing stimulated Raman scattering in plasma in conjunction with a "flying focus" - a chromatic focusing system combined with a chirped pump beam that provides spatiotemporal control over the pump's focal spot. Pump intensity isosurfaces are made to propagate at v=-c so as to be in sync with the injected counterpropagating seed pulse. By setting the pump intensity in the interaction region to be just about the ionization threshold of the background gas, an ionization wave is produced that travels at a fixed distance ahead of the seed. Simulations show that this will make it possible to optimize the plasma temperature and mitigate many of the issues that are known to have impacted previous Raman amplification experiments, in particular, the growth of precursors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

EXILL—a high-efficiency, high-resolution setup for γ-spectroscopy at an intense cold neutron beam facility

In the EXILL campaign a highly efficient array of high purity germanium (HPGe) detectors was operated at the cold neutron beam facility PF1B of the Institut Laue-Langevin (ILL) to carry out nuclear structure studies, via measurements of γ-rays following neutron-induced capture and fission reactions. The setup consisted of a collimation system producing a pencil beam with a thermal capture equivalent flux of about 10 8 n s -1 cm -2 at the target position and negligible neutron halo. The target was surrounded by an array of eight to ten anti-Compton shielded EXOGAM Clover detectors, four to six anti-Compton shielded large coaxial GASP detectors and two standard Clover detectors. For a part of the campaign the array was combined with 16 LaBr 3 :(Ce) detectors from the FATIMA collaboration. The detectors were arranged in an array of rhombicuboctahedron geometry, providing the possibility to carry out very precise angular correlation and directional-polarization correlation measurements. The triggerless acquisition system allowed a signal collection rate of up to 6 × 10 5 Hz. The data allowed to set multi-fold coincidences to obtain decay schemes and in combination with the FATIMA array of LaBr 3 :(Ce) detectors to analyze half-lives of excited levels in the pico- to microsecond range. Precise energy and efficiency calibrations of EXILL were performed using standard calibration sources of 133 Ba, 60 Co and 152 Eu as well as data from the reactions 27 Al(n,γ) 28 Al and 35 Cl(n,γ) 36 Cl in the energy range from 30 keV up to 10 MeV.

47 OTHER INSTRUMENTATION↗

Analysis of 161 Tb by radiochemical separation and liquid scintillation counting

The determination of 161 Tb activity is problematic due to its very low fission yield, short half-life, and the complication of its gamma spectrum. At AWE, radiochemically purified 161 Tb solution was measured on a PerkinElmer 1220 Quantulus TM Liquid Scintillation Spectrometer. Since there was no 161 Tb certified standard solution available commercially, the counting efficiency was determined by the CIEMAT/NIST Efficiency Tracing method. The method was validated during a recent inter-laboratory comparison exercise involving the analysis of a uranium sample irradiated with thermal neutrons. Lastly, the measured 161 Tb result was in excellent agreement with the result using gamma spectrometry and the result obtained by Pacific Northwest National Laboratory.

07 ISOTOPE AND RADIATION SOURCES↗

Polarimetry diagnostic on OMEGA EP using a 10-ps, 263-nm probe beam

A polarimetry diagnostic was built and characterized for magnetic-field measurements in laser-plasma experiments on the OMEGA EP laser. This diagnostic was built into the existing 4ω (263-nm) probe system that employs a 10-ps laser pulse collected with an f/4 imaging system. The diagnostic measures the rotation of the probe beam's polarization. The polarimeter uses a Wollaston prism to split the probe beam into orthogonal polarization components. Spatially localized intensity variations between images indicate polarization rotation. Magnetic fields can be calculated by combining the polarimetry data with the measured plasma density profile obtained from angular filter refractometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Volcanism on Io

Explore the source record for details and available documents.

Io Galileo volcanism↗

Autonomous Science on the EO-1 Mission

In mid-2003, we will fly software to detect science events that will drive autonomous scene selectionon board the New Millennium Earth Observing 1 (EO-1) spacecraft. This software will demonstrate the potential for future space missions to use onboard decision-making to detect science events and respond autonomously to capture short-lived science events and to downlink only the highest value science data.

autonomous systems robust execution↗

The Techsat-21 autonomous space science agent

In this paper we discuss how these AI technologies are synergistically integrated in a hybrid multi-layer control architecture to enable a virtual spacecraft science agent.

autonomy software agents onboard decision-making↗

Upper bound on Io's heat flow

Analysis of the temperatures and areas of Io's thermal anomalies yields an upper bound on the total heat flow.

Thermal emmission infrared observationstemperature↗