Application of the Cohn-alpha Method on Bare Highly Enriched Uranium Using Organic Scintillators [Poster]

The prompt neutron decay constant (α), can be used to calculate the lifetime of prompt fission chains within a multiplying system and verify reactor startup and shutdown. We analyze a fast, bare system consisting of highly enriched uranium (93% 235 U) hemisphere shells known as the Measurements of Uranium Subcritical and Critical (MUSiC). We measured the system with a three by-four array of organic scintillators (OSCAR) to obtain the gamma-ray and fast neutron signals. Pulse shape discrimination was used to isolate the neutron time series data. The Cohn-α method was used to estimate α for 3 supercritical measurements of Configurations 8 MUSiC. We use these estimates to linearly extrapolate α at delayed critical. These values can be compared to highly detailed simulations in MCNP6.2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiplicity counting using organic scintillators to distinguish neutron sources: An advanced teaching laboratory

In this advanced instructional laboratory, students explore complex detection systems and nondestructive assay techniques used in the field of nuclear physics. After setting up and calibrating a neutron detection system, students carry out timing and energy deposition analyses of radiation signals. Through the timing of prompt fission neutron signals, multiplicity counting is used to carry out a special nuclear material (SNM) nondestructive assay. Our experimental setup is comprised of eight trans-stilbene organic scintillation detectors in a well-counter configuration, and measurements are taken on a spontaneous fission source as well as two (α,n) sources. By comparing each source's measured multiplicity distribution, the resulting measurements of the (α,n) sources can be distinguished from that of the spontaneous fission source. Such comparisons prevent the spoofing, i.e., intentional imitation, of a fission source by an (α,n) neutron source. This instructional laboratory is designed for nuclear engineering and physics students interested in organic scintillators, neutron sources, and nonproliferation radiation measurement techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary verification of the MCNP perturbation and fixed-source tally sensitivity tools

Integral benchmark experiments are vital in the adjustment and validation of the nuclear data that govern predictive simulations across the nuclear community. The nuclear data sensitivity capabilities of the Monte Carlo N-Particle (MCNP ®) transport code are currently limited; however, expanding sensitivity capabilities will allow benchmark experiments to be designed to resolve compensating errors and adjust nuclear data where previously prohibitively difficult. This paper provides details of a preliminary verification for the use of (i.) the recently revised perturbation and (ii.) developmental fixed-source sensitivity tools within MCNP to calculate sensitivities of tallied responses (such as current integrated over a surface, F1, and flux averaged over a cell, F4) to nuclear data in fixed-source simulations. Energy-binned and energy-integrated sensitivities calculated with these tools are compared against sensitivities calculated using a central-difference approximation. Here, the verification is completed for four configurations of a benchmarked system using a 4.5-kg plutonium sphere surrounded by varying amounts of copper and/or polyethylene. The results show that sensitivities calculated with the perturbation and fixed-source sensitivity tools agree with the central-difference-based approach.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Examination of Digital-Delay Rossi-$\alpha$ for 252 Cf-Driven Highly Enriched Uranium Using Organic Scintillators

Neutron noise techniques constitute several analysis methods applicable to non-destructive assay. One technique is the Rossi-α method to calculate the prompt neutron decay constant (α) or its inverse, the prompt neutron period (1/α), for assemblies of fissionable material. This work evaluates a high-data-throughput measurement at the National Criticality Experiments Research Center (NCERC) with organic scintillators measuring a subcritical assembly of highly enriched uranium (HEU) metal (93% 235 U). The assembly comprises hemi shells stacked together to form fully closed shells and is driven by a Cf source at the center. The assembly is a total of 59.85 kg HEU and a k eff of 0.99, according to MCNP6.2 KCODE simulations. Measurements were acquired with a three-by-four array of 5.08-cm-diameter by 5.08-cm-length trans-stilbene crystals 166 cm from the assembly center. Two types of coincident binning methods are used to build the Rossi-α distribution of coincident neutron detections: A) type 1 binning, also known as any-and-all forward time differences, and B) type 1 binning with a digital-delay technique that is analogous to Orndoff’s use of delay cabling in early Rossi-alpha measurements. Method B) disregards same-detector coincidences and once all nearest time coincidences are collected between all detectors after a trigger, a time delay of 0.75 µs is implemented. The measured prompt neutron decay constants for both techniques are calculated from single exponential fits and the two methods are compared. Method A) shows an apparent timing discontinuity near 500 ns time differences. This timing discontinuity interferes with the fitting method used to calculate the prompt neutron decay constant. Method B) mitigates the artificial timing discontinuity and removes the disagreement of the fit. Future work will model the time-dependent detector response to discern why this timing discontinuity occurs, discern how Method B) reduces the amplitude of this timing discontinuity, and apply this method to critical assembly measurements to ultimately confirm the recommendation to use Method B) for high-data-throughput measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of Photoneutrons from Depleted Uranium and Comparison Study Using MCNPX-PoliMi

High-energy photon interrogation is a nondestructive technique that is used to detect special nuclear materials and characterize nuclear waste. The development of such systems is complex and requires Monte Carlo simulations to optimize system performance. Monte Carlo simulations rely on various scattering, absorption, and photonuclear cross-section data. While the scattering and absorption cross-section data have been extensively studied and validated with experiments, the results obtained from photonuclear simulations are often found to underpredict measured results, indicating uncertainties in the photonuclear cross sections themselves. Thus, there is a need for new measured results that can be used to quantify underpredictions in simulations using photonuclear cross-section data. In the present work, we interrogated depleted uranium with a 9-MV electron linac and detected photoneutrons with trans-stilbene organic scintillators. The measurement of photoneutrons with organic scintillators is challenging due to the presence of the intense photon flux, which causes issues such as pulse pile-up, detector saturation, and poor signal-to-background ratio. To mitigate these challenges, we used iron and polyethylene shielding of varying thicknesses around the depleted uranium target and a neural network–based digital pulse processing algorithm to recover neutron and photon information from piled-up events. Our goal was to compare the measured photoneutron count rate with the simulated rate obtained using the MCNPX-PoliMi transport code. For a light output window of 0.28 to 2.67 MeVee (1.66- to 6.85-MeV proton recoil energy), we found that the simulated count rate obtained using the ENDF/B-VII photonuclear cross-section library underpredicts the measured rate by 32.8% 3.2%. Additionally, we compared the simulated and measured photoneutron light output distributions. For the least thicknesses of shielding, the simulation was found to underpredict measurements in the 0.70- to 2.67-MeVee light output window. For the greatest thicknesses of shielding, the simulation was found to underpredict the measurement across the entire light output window of 0.28 to 2.67 MeVee.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Correlations between energy and $\gamma$-ray emission in 239 Pu($n, f$)

Here, we study $\gamma$-ray emission following $^{239}\mathrm{Pu}(n,\mathrm{f})$ over an incident neutron energy range of $2 < E_i < 40$ MeV. We present the first experimental evidence for positive correlations between the total angular momentum generated in fission and the excitation energy of the compound nucleus prior to fission. The $\gamma$-ray multiplicity increases linearly with incident energy below the 2\textsuperscript{nd}-chance fission threshold with a slope of $0.085 \pm 0.010$~MeV$^{-1}$. This linear trend appears to hold for the average excitation energy of the compound nucleus between $9 < \langle E_x \rangle < 19$ MeV. Most of the multiplicity increase comes from an enhancement around a $\gamma$-ray energy of 0.7 MeV, which we interpret as stretched quadrupole $\gamma$ rays that indicate an increase in total fission-fragment angular momentum with excitation energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Real-time mixed reality display of dual particle radiation detector data

Radiation source localization and characterization are challenging tasks that currently require complex analyses for interpretation. Mixed reality (MR) technologies are at the verge of wide scale adoption and can assist in the visualization of complex data. Herein, we demonstrate real-time visualization of gamma ray and neutron radiation detector data in MR using the Microsoft HoloLens 2 smart glasses, significantly reducing user interpretation burden. Radiation imaging systems typically use double-scatter events of gamma rays or fast neutrons to reconstruct the incidence directional information, thus enabling source localization. The calculated images and estimated ’hot spots’ are then often displayed in 2D angular space projections on screens. By combining a state-of-the-art dual particle imaging system with HoloLens 2, we propose to display the data directly to the user via the head-mounted MR smart glasses, presenting the directional information as an overlay to the user’s 3D visual experience. We describe an open source implementation using efficient data transfer, image calculation, and 3D engine. We thereby demonstrate for the first time a real-time user experience to display fast neutron or gamma ray images from various radioactive sources set around the detector. We also introduce an alternative source search mode for situations of low event rates using a neural network and simulation based training data to provide a fast estimation of the source’s angular direction. Using MR for radiation detection provides a more intuitive perception of radioactivity and can be applied in routine radiation monitoring, education & training, emergency scenarios, or inspections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Multiplicity Counting Diagnosis of Uranium Assemblies Interrogated by Cf-252 [Poster]

Researchers concluded: First neutron multiplicity counting of tens of kilograms of 235 U with organic scintillators; leakage multiplication estimates to be improved by incorporating detector cross-talk; provides data comparison for “Multiplicity Theory Beyond the Point Model;" promotes continued use of organic scintillators for NCERC and elsewhere.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Verification of Revised and Upcoming Nuclear Data Sensitivity MCNP Features [Poster]

Nuclear data is ubiquitous across nuclear applications. Improved nuclear data means more accurate simulations. Past focus on k eff caused compensating error and areas of unvalidated nuclear data. Sensitivity can be used to optimize experiments to focus on specific areas. Sensitivity capabilities must be expanded and improved to design multivariate experiments focused on nuclear data needs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Directional dependence of the event-by-event neutron-γ multiplicity correlations in 252 Cf(sf)

We differentiate the event-by-event n-γ multiplicity data from 252 Cf(sf) with respect to the energies of the emitted particles as well as their relative angles of emission. We determine that neutron emission enhances γ-ray emission around 0:7 and 1:2 MeV, but the only directional alignment was observed for E γ ≤ 0:7 MeV and tended to be parallel and antiparallel to neutrons emitted in the same event. The emission of γ rays at other energies was determined to be nearly isotropic. The presence of the emission and alignment enhancements is explained by positive correlations between neutron emission and quadrupole γ-ray emission along rotational bands in the de-exciting fragments. This observation corroborates the hypothesis of positive correlations between the angular momentum of a fragment and its intrinsic excitation energy. The results of this work are especially relevant in view of the recent theoretical and experimental interest in the generation of angular momentum in fission. Specifically, we have determined an alignment of the fragments angular momenta in a direction perpendicular to the direction of motion. We interpret the lack of n-γ angular correlations for fission fragments near closed shells as a weakening of the alignment process for spherical nuclei. Lastly, we have observed that statistical γ rays are emitted isotropically, indicating that the average angular momentum removed by this radiation is small. These results, and the analysis tools presented in this work, represent a stepping stone for future analysis of n-γ emission correlations and their connection to angular momentum properties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Verification of Upcoming MCNP Features For Estimating Nuclear Data Sensitivities in Fixed Source Simulations [Abstract]

Predictive simulation codes, like the Monte Carlo N-Particle (MCNP) transport code, are used throughout the nuclear community. These simulations are based on nuclear data. Maximizing the accuracy and precision of nuclear data maximizes the accuracy and precision of the overall simulation. This is imperative to applications that rely on simulations. For example, improving nuclear data for special nuclear material improves simulation accuracy in stockpile stewardship applications, which results in larger safety margins and decreased operational costs. The improvement and validation of nuclear data is completed through integral benchmark experiments. Past benchmarks have primarily been limited to focus on the effective multiplication factor ($\kappa$ eff ); broadening the purview of benchmarks beyond $\kappa$ eff -dependent nuclear data addresses nuclear data deficiencies. Different response types depend on different areas of nuclear data. This dependence is quantified as nuclear data sensitivity: the change in response due to perturbation of a contributing parameter. The larger the nuclear data sensitivity of a response, the more the experiment is influenced by the uncertainties of the nuclear data. The optimization of nuclear data sensitivities in future benchmarks would result in more detailed validation of lesser studied areas of nuclear data. Currently, direct sensitivity capabilities are not easily found for all experiment types and parameters. An MCNP tool to directly estimate the cross section sensitivities of tallied values is under development. Additionally, updates have been made to the perturbation feature of MCNP, which can be used in a less direct approach to estimating sensitivities. This work verifies these features to estimate nuclear data sensitivities in fixed source simulations of a 4.5-kg sphere of alpha- phase weapons-grade plutonium surrounded by differing amounts of copper and polyethylene. Integrated estimates made using MCNP’s tools were found to statistically agree with integrated estimates made from manual perturbation of nuclear data proving the validity of the MCNP tools.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Verification of Flux Sensitivity Estimates Using the MCNP Tally Perturbation Tool

Nuclear data is commonly used in applications such as nuclear nonproliferation, safeguards, and criticality safety. More specifically, nuclear data is used in predictive simulation codes like the Monte-Carlo N-Particle (MCNP ® ) transport code, Serpent, and similar radiation transport codes. The improvement of nuclear data enables more precise and accurate simulations, which result in higher fidelity designs and reduced operational/procedural costs. Therefore, the improvement of nuclear data is of paramount importance across the nuclear community. Nuclear data is improved and validated through integral benchmark experiments. The design of benchmark experiments is an extensive process; therefore, these experiments are often optimized on multiple characteristics, including sensitivity to the nuclear data, during the design process. Sensitivity is a measure of how much a quantity changes due to changes in independent variables such as experimental configuration. An experimental design that has a larger sensitivity to the nuclear data of interest will have a larger impact on the accuracy and precision of the validated data. Past integral benchmark experiments have primarily used the effective multiplication factor ($k_{eff}$) as the predominant measured quantity; however, experiments designed with other quantities in mind would be able to optimize on validating different areas of the nuclear data. A primary goal of the EUCLID project is to design, constrain, and reduce compensating errors in experiments focused on quantities other than $k_{eff}$ to better validate nuclear data across the board. Currently, there is a capability in MCNP to easily calculate the sensitivity of $k_{eff}$ to specific nuclear data of numerous reactions types and isotopes (KSEN card); however, the sensitivity of other quantities must be estimated in more strenuous manners. For example, the perturbation feature (PERT card) of MCNP can be used to estimate first-order sensitivities of some response in fixed source simulations. A recent announcement revealed that the first- and second-order perturbation features in previous releases of MCNP contained a bug. It was identified that particles were being scored into the wrong energy bin. The bug is in the most recent public release (MCNP6.2); however, a patch has been added to the most up to date version (MCNP6.2.2) that has not been released publicly. A direct comparison of the PERT card results for an F4 (neutron flux averaged over a cell) tally before and after the patch are shown in figure 1. All simulations used in the sensitivity estimates in this report were performed with MCNP6.2.2. This work verifies the patched MCNP perturbation tool by comparing first order sensitivities made using the PERT card to estimates made using manual perturbation of the compact ENDF (ACE) files.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron Imaging Using Organic Glass Scintillators

In this work, we develop of a compact neutron imaging system based on organic glass scintillator and silicon photomultiplier arrays. The recently developed organic glass scintillator has excellent neutron and gamma-ray detection efficiency and exhibits pulse shape discrimination capability that is nearly as good as current state-of-the-art materials such as trans-stilbene. We have cast and characterized 6 mm by 6 mm by 50 mm bars of organic glass in our laboratory. When coupled to a silicon photomultiplier array, these bars demonstrated better energy and timing resolution than the stilbene organic scintillator. Here, this performance makes organic glass an ideal material for a compact neutron imaging system, which must resolve neutron scatter events on a sub-nanosecond time scale. We have demonstrated neutron imaging with bars of organic glass scintillator coupled to arrays of silicon photomultipliers. Additional bars of organic glass will be implemented into the system to improve the efficiency and imaging performance. The resulting system will be demonstrated using 252 Cf and PuBe neutron sources in our laboratory. In addition, we will compare imaging performance to other compact neutron imaging systems that exist in literature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structure in the event-by-event energy-dependent neutron-$γ$ multiplicity correlations in 252 Cf(sf)

The emission of neutrons and γ rays by fission fragments reveal important information about the properties of fragments immediately following scission. The initial fragment properties, correlations between fragments, and emission competition give rise to correlations in neutron-γ emission. Recent theoretical and experimental advances have been proposed to explain the mechanism of angular momentum generation in fission, which would result in observable signature in neutron-γ emission correlations. In this paper, we present a novel analysis method of neutrons and γ rays emitted by fission fragments that allows us to discern structure in the observed correlations. We have analyzed data collected on 252 Cf (sf) at the Chi-Nu array at the Los Alamos Neutron Science Center. Through our analysis of the energy-differential neutron-γ multiplicity covariance, we have observed enhanced neutron-γ correlations, corresponding to rotational band γ-ray transitions, at γ-ray energies of 0.7 and 1.2 MeV. To shed light on the origin of this structure, we compare the experimental data with the predictions of three model calculations. The origin of the observed correlation structure is understood in terms of a positive spin-energy correlation in the generation of angular momentum in fission.