Simulation tools, first results and experimental status of the MURAVES experiment

The MUon RAdiography of VESuvius (MURAVES) project aims at the study of Mt. Vesuvius, an active and hazardous volcano near Naples, Italy, with the use of muons freely and abundantly produced by cosmic rays. In particular, the MURAVES experiment intends to perform muographic imaging of the internal structure of the summit of Mt. Vesuvius. The challenging measurement of the rock density distribution in its summit by muography, in conjunction with data from other geophysical techniques, can help model possible eruption dynamics. The MURAVES apparatus consists of an array of three independent and identical muon trackers, with a total sensitive area of 3 square meters. In each tracker, a sequence of 4 XY tracking planes made of plastic scintillators is complemented by a 60 cm thick lead wall inserted between the two downstream planes to improve rejection of background from low energy muons. The apparatus is currently acquiring data. This paper presents preliminary results from the analysis of the first data samples acquired with trackers pointing towards Mt. Vesuvius, including the first relative measurement of the density projection of two flanks of the volcano at three different altitudes; we also present the workflow of the simulation chain of the MURAVES experiment and its ongoing developments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large scale SiPM testing for the Cosmic Muon Veto detector

A Cosmic Muon Veto (CMV) detector using extruded plastic scintillators is being built around the mini-Iron Calorimeter (mini-ICAL) detector at the transit campus of the India based Neutrino Observatory, Madurai. The extruded plastic scintillators will be embedded with wavelength shifting (WLS) fibres to absorb scintillating photons and propgate the re-emitted photons to the silicon-photomultipliers for the electronic signals. The CMV detector will require 760 extruded plastic scintillators to shield the mini-ICAL detector, and will require 3040 SiPMs for the readout. The design goal for the cosmic muon veto efficiency of the CMV is $>$99.99\% and fake veto rate less than 10$^{-5}$. Hence, every SiPM used in the detector needs to be characterised to satisfy the design goal of the CMV. For this, a large-scale testing system was developed, using an LED driver, to measure the gain and noise rate of each SiPM, and thus determine it's breakdown voltage ($V_{br}$) and optimum operating overvoltage ($V_{ov}$).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mass testing of SiPMs for the CMVD at IICHEP

A Cosmic Muon Veto Detector (CMVD) is being built around the mini-Iron Calorimeter (mini-ICAL) detector at the transit campus of the India based Neutrino Observatory, Madurai. The CMV detector will be made using extruded plastic scintillators with embedded wavelength shifting (WLS) fibres which propagate re-emitted photons of longer wavelengths to silicon photo-multipliers (SiPMs). The SiPMs detect these scintillation photons, producing electronic signals. The design goal for the cosmic muon veto efficiency of the CMV is $>$99.99% and fake veto rate less than 10$^{-5}$. A testing system was developed, using an LED driver, to measure the noise rate and gain of each SiPM, and thus determine its overvoltage ($V_{ov}$). This paper describes the test results and the analysed characteristics of about 3.5k SiPMs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Qualification study of SiPMs on a large scale for the CMVD Experiment

A Cosmic Muon Veto (CMV) detector using extruded plastic scintillators is being designed around the mini-Iron Calorimeter (mini-ICAL) detector at the transit campus of the India based Neutrino Observatory, Madurai for the feasibility study of shallow depth underground experiments. The scintillation signals that are produced in the plastic due to muon trajectories are absorbed by wavelength shifting (WLS) fibres. The WLS fibres re-emit photons of longer wavelengths and propagate those to silicon photo-multipliers (SiPMs). The SiPMs detect these photons, producing electronic signals. The CMV detector will use more than 700 scintillators to cover the mini-ICAL detector and will require around 3000 SiPMs. The design goal for the cosmic muon veto efficiency of the CMV is >99.99%. Hence, every SiPM used in the detector needs to be tested and characterised to satisfy the design goal of CMV. A mass testing system was developed for the measurement of gain and choice of the overvoltage ($V_{ov}$) of each SiPMs using an LED driver. The $V_{ov}$ is obtained by studying the noise rate, the gain of the SiPM. This paper describes the experimental setup used to test the SiPMs characteristics along with detailed studies of those characteristics as a function of temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutrino Scattering Measurements on Hydrogen and Deuterium: A Snowmass White Paper

Neutrino interaction uncertainties are a limiting factor in current and next-generation experiments probing the fundamental physics of neutrinos, a unique window on physics beyond the Standard Model. Neutrino-nucleon scattering amplitudes are an important part of the neutrino interaction program. However, since all modern neutrino detectors are composed primarily of heavy nuclei, knowledge of elementary neutrino-nucleon amplitudes relies heavily on experiments performed in the 1970s and 1980s, whose statistical and systematic precision are insufficient for current needs. In this white paper, we outline the motivation for attempting measurements on hydrogen and deuterium that would improve this knowledge, and we discuss options for making these measurements either with the DUNE near detector or with a dedicated facility.

Alvarez-Ruso, Luis↗

Bubble Chamber Detectors with Light Nuclear Targets: A Snowmass 2021 White Paper

Neutrino cross sections are a critical ingredient in experiments that depend on neutrino scattering to reconstruct event kinematics and infer neutrino characteristics, like NOvA and T2K. An opportunity exists to reduce the 5-10% broad uncertainty on neutrino cross sections by producing more measurements of neutrino scattering from light nuclear targets at the relevant energies. Bubble chambers with light nuclear targets would be ideal for these measurements but the most recent device designed for use with an accelerator neutrino source is at least fifty years old. A new bubble chamber with light nuclear targets could be designed by observing how the technology has progressed for use in dark matter experiments and producing smaller modular devices that use more efficient cooling systems. A smaller modular device could also be designed for deployment to all functioning neutrino beams, but an investigation of the proper operating characteristics is necessary to adapt newer detectors to the structure of contemporary neutrino beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Physics Case for a Neutrino Factory

Neutrino factories, neutrino beams produced in the decay of a muon or antimuon beam inside a storage ring, yield cleaner, richer, and more flexible neutrino beams relative to super-beams. We explore the physics case for this type of beam both for standard oscillation as well as new physics searches and present some machine options. We argue that there is a rich program beyond what the current neutrino program can cover and a string synergy with the muon collider program.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of Silicon-Photomultipliers for a Cosmic Muon Veto detector

A Cosmic Muon Veto (CMV) detector using extruded scintillators is being designed around the mini-Iron Calorimeter detector at the transit campus of the India-based Neutrino Observatory, Madurai for measuring its efficiency at shallow depth underground experiments. The scintillation signal is transmitted through a Wavelength Shifting (WLS) fibre and readout by Hamamatsu Silicon-Photomultipliers (SiPMs). A Light Emitting Diode (LED) system is included on the front-end readout for in-situ calibration of the gain of each SiPM. A characterization system was developed for the measurement of gain and choice of the overvoltage (V ov ) of SiPMs using the LED as well as a cosmic muon telescope. The V ov is obtained by studying the noise rate, the gain of the SiPM, and the muon detection efficiency. In case of any malfunction of the LED system during the operation, the SiPM can also be calibrated with the noise data as well as using radioactive sources. Furthermore, this paper describes the basic characteristics of the SiPM and the comparison of the calibration results using all three methods, as well as the V ov of the SiPMs and muon selection criteria for the veto detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Conceptual Design of DUNE Near Detector Superconducting Magnet System

The Deep Underground Neutrino Experiment (DUNE) has formed a near detector design group (NDDG) tasked with delivering a CDR by the end of 2019. The DUNE Near Detectors will be housed in an underground hall on the Fermilab site. The two main detector systems are a liquid argon detector and a high-pressure gas time projection chamber (HPgTPC). The HPgTPC requires a magnet that generates a 0.5 T solenoidal magnetic field in a large volume of 6 m diameter, and 5 m length. Herein, we present a superconducting magnet system design. We investigated: an open air core magnet with three coils, and a five coils system having two active fringe field shielding coils. Coils positions were optimized to obtain the specified field homogeneity in the magnet good field region, while minimizing the Lorentz forces and the superconductor volume. We discuss the magnetic, mechanical, and thermal conceptual designs.

43 PARTICLE ACCELERATORS↗

A New Concept for Kilotonne Scale Liquid Argon Time Projection Chambers

We develop a novel Time Projection Chamber (TPC) concept suitable for deployment in kilotonne-scale detectors, with a charge-readout system free from reconstruction ambiguities, and a robust TPC design that reduces high-voltage risks while increasing the coverage of the light-collection system and maximizing the active volume. This novel concept could be used as a far detector module in the Deep Underground Neutrino Experiment (DUNE). For the charge-readout system, we used the charge-collection pixels and associated application-specific integrated circuits currently being developed for the liquid argon (LAr) component of the DUNE Near Detector design, ArgonCube. In addition, we divided the TPC into a number of shorter drift volumes, reducing the total voltage used to drift the ionization electrons, and minimizing the stored energy per TPC. Segmenting the TPC also contains scintillation light, allowing for precise trigger localization and a more expansive light-readout system. Furthermore, the design opens the possibility of replacing or upgrading components. These augmentations could substantially improve the reliability and the sensitivity, particularly for low-energy signals, in comparison to traditional monolithic LArTPCs with projective-wire charge readouts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The DUNE Near Detector Complex [Slides]

The DUNE Near Detector Design Group (NDDG) has been formed to deliver a CDR for near detectors and the facility. I have outlined the basic approach that is being studied and which will form the bases of the CDR to a large extent.

43 PARTICLE ACCELERATORS↗

Operational Experience with the MICE Spectrometer Solenoid System

The Muon Ionization Cooling Experiment located at Rutherford Appleton Laboratory in England utilizes a supercon-ducting solenoid system for the muon cooling channel that also holds particle tracking detectors and muon absorbers inside their bores. The solenoid system installation was completed in summer of 2015 and after commissioning the system it has been running successfully. As a result, this paper summarizes the commissioning results and operational experience with the magnets focusing on the per-formance of the two Spectrometer Solenoids built by the US.

43 PARTICLE ACCELERATORS↗

Analysis of the Training Behavior of the MICE Spectrometer Solenoid

Muon ionization cooling is theoretically well understood but has never been fully demonstrated experimentally. Ionization cooling is regarded as an important technology both in terms of cost and performance for a Neutrino Factory and is absolutely essential for a Muon Collider. The MICE experiment (Muon Ionization Cooling Experiment), based at the Rutherford Appleton Laboratory, U.K., is currently collecting data to prove the concept. Part of MICE are two spectrometer magnets, each consisting of five superconducting large bore solenoids. The spectrometer solenoid is designed for a peak field of 4T. Both spectrometer magnets required about 15 quenches to reach the design current. However, it was discovered that both spectrometers do not remember their training; after a warm-up the spectrometers have to be retrained, following a very similar training curve. The MICE spectrometer was analyzed using 2-D and 3-D finite element software to understand the quench and training behavior; the analysis revealed a clamping mechanism, leading to a stick-slip situation for one of the coils in its coil pocket. This paper summarizes the results and makes suggestions how to improve the design.

43 PARTICLE ACCELERATORS↗

Muography of the Puy de Dôme

Muon radiography is an imaging technique that relies on the transmission of cosmic muons through matter. It allows the measurement of density maps of large structures such as volcanoes. Furthermore, during the second half of 2013 the MURAY detector prototype carried out a data taking at the Puy de Dôme in the framework of the scientific collaboration with the experiment TOMUVOL in order to compare the results and performance of the two different detectors. Finally, both experimental apparatuses measure a muon transmission of some orders of magnitude higher than that expected highlighting a background that perturbs these measures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress on the MICE RF Module at LBNL

The international Muon Ionization Cooling Experiment aims to demonstrate the transverse cooling of a muon beam by ionization in energy absorbers. The final MICE cooling channel configuration has two RF modules, each housing a 201 MHz RF cavity used to compensate the longitudinal energy loss in the absorbers. The assembly of MICE RF Module is being carried out at LBL. In this paper we will report the recent progress on the assembly work.

43 PARTICLE ACCELERATORS↗

nuSTORM FFAG Decay Ring

The neutrino beam produced from muons decaying in a storage ring would be an ideal tool for precise neutrino cross section measurements and search for sterile neutrinos due to its precisely known flavour content and spectrum. In the proposed nuSTORM facility pions would be directly injected into a racetrack storage ring, where circulating muon beam would be captured. The storage ring has two options: a FODO solution with large aperture quadrupoles and a racetrack FFAG (Fixed Field Alternating Gradient) using the recent developments in FFAGs. Machine parameters, linear optics design and beam dynamics are discussed in this paper.

43 PARTICLE ACCELERATORS↗

FFAG Beam Line for nuPIL - Neutrinos from PIon Beam Line

The Long Baseline Neutrino Facilities (LBNF) program aims to deliver a neutrino beam for the Deep Underground Neutrino Experiment (DUNE). The current baseline for LBNF is a conventional magnetic horn and decay pipe system. Neutrinos from PIon beam Line (nuPIL) is a part of the optimization effort to optimize the LBNF. It consists of a pion beam line after the horn to clean the beam of high energy protons and wrong-sign pions before transporting them into a decay beam line, where instrumentation could be implemented. This paper focuses on the FFAG solution for this pion beam line. The resulting neutrino flux is also presented.

43 PARTICLE ACCELERATORS↗

The MURAVES muon telescope: technology and expected performances

Here, the MURAVES project aims to study the inner structure of the upper part of the Mt. Vesuvius volcano by muon radiography (muography) technique. Very high energy muons, produced by cosmic rays in the atmosphere, can penetrate large thickness of rocks. By measuring the attenuation of the muons flux trough the volcano cone is possible to obtain a 2D image of the density structure. Internal discontinuities, with a spatial resolution of about 10 m, can be, in principle, resolved. An absolute average density measurement can be provided too. The project, funded by the Italian Ministry of University, Research and Education (MIUR), is led by INGV and INFN. In this article the mechanical structure of the detectors and background suppression techniques are reported.