Second Flight of the Zeno Experiment on USMP-3

The second flight of the Zeno experiment in the USMP-3 flight has shown successful control of density perturbations near the window surfaces. These density changes were demonstrated to be arising from the rate of temperature change in the sample cell during the flight. These effects could be controlled by using decreasing ramp rates as Tc was approached. The cell window interference was carefully recorded to provide data about the phase of the interference close to the critical point and the effective window reflectivity. Correlograms were recorded from 500 mili K down to 2 mili K at 24 temperatures, 383 correlograms in all. The efforts to get closer were prevented by a long (greater than two week time constant) decay of a 1.3% density error caused by local heating from the 17 micro W laser beam. The phase boundary was located with unprecedented precision of +/- 2O micro K. The complete experiment sequence was done with ground commanding and uploaded script files, bypassing the original autonomous-mode program sequence.

Gammon, Robert W.

Zeno: Critical Fluid Light Scattering Experiment

The Zeno (Critical Fluid Light Scattering) experiment is the culmination of a long history of critical fluid light scattering in liquid-vapor systems. The major limitation to making accurate measurements closer to the critical point was the density stratification which occurs in these extremely compressible fluids. Zeno was to determine the critical density fluctuation decay rates at a pair of supplementary angles in the temperature range 100 mK to 100 (mu)K from T(sub c) in a sample of xenon accurately loaded to the critical density. This paper gives some highlights from operating the instrument on two flights March, 1994 on STS-62 and February, 1996 on STS-75. More detail of the experiment Science Requirements, the personnel, apparatus, and results are displayed on the Web homepage at http://www.zeno.umd.edu.

Gammon, Robert W.

Highlights of the Zeno Results from the USMP-2 Mission

The Zeno instrument, a High-precision, light-scattering spectrometer, was built to measure the decay rates of density fluctuations in xenon near its liquid-vapor critical point in the low-gravity environment of the U.S. Space Shuttle. Eliminating the severe density gradients created in a critical fluid by Earth's gravity, we were able to make measurements to within 100 microKelvin of the critical point. The instrument flew for fourteen days in March, 1994 on the Space Shuttle Columbia, STS-62 flight, as part of the very successful USMP-2 payload. We describe the instrument and document its performance on orbit, showing that it comfortably reached the desired 3 microKelvin temperature control of the sample. Locating the critical temperature of the sample on orbit was a scientific challenge; we discuss the advantages and short-comings of the two techniques we used. Finally we discuss problems encountered with making measurements of the turbidity of the sample, and close with the results of the measurement of the decay rates of the critical-point fluctuations.

Gammon, Robert W.

Statistical fitting accuracy in photon correlation spectroscopy

Continuing our experimental investigation of the fitting accuracy associated with photon correlation spectroscopy, we collect 150 correlograms of light scattered at 90 deg from a thermostated sample of 91-nm-diameter, polystyrene latex spheres in water. The correlograms are taken with two correlators: one with linearly spaced channels and one with geometrically spaced channels. Decay rates are extracted from the single-exponential correlograms with both nonlinear least-squares fits and second-order cumulant fits. We make several statistical comparisons between the two fitting techniques and verify an earlier result that there is no sample-time dependence in the decay rate errors. We find, however, that the two fitting techniques give decay rates that differ by 1 percent.

Shaumeyer, J. N.

Measurement of the temperature coefficient of ratio transformers

We have measured the temperature coefficient of the output of several ratio transformers at ratios near 0.500,000 using an ac bridge and a dual-phase, lock-in amplifier. The two orthogonal output components were each resolved to +/- ppb of the bridge drive signal. The results for three commercial ratio transformers between 20 and 50 C range from 0.5 to 100 ppb/K for the signal component in phase with the bridge drive, and from 4 to 300 ppb/K for the quadrature component.

Briggs, Matthew E.

The susceptibility critical exponent for a nonaqueous ionic binary mixture near a consolute point

We report turbidity measurements of a nonaqueous ionic solution of triethyl n-hexylammonium triethyl n-hexylboride in diphenyl ether. A classical susceptibility critical exponent gamma = 1.01 +/- 0.01 is obtained over the reduced temperature range t between values of 0.1 and 0.0001. The best fits of the sample transmission had a standard deviation of 0.39 percent over this range. Ising and spherical model critical exponents are firmly excluded. The correlation length amplitude xi sub 0 from fitting is 1.0 +/- 0.2 nm which is much larger than values found in neutral fluids and some aqueous binary mixtures.

Zhang, Kai C.

Critical speeding up in pure fluids

The extreme compressibility of a pure fluid near its critical point significantly affects its bulk dynamic response to temperature changes through adiabatic processes. Equations that describe the dynamics in the absence of gravity are developed, and the magnitude of the effect is illustrated with numerical solutions in one dimension. The results are remarkable: 5 mm of critical xenon, quenched from 20 to 10 mK above its critical temperature, cools by over 99 percent in less than 5 s. Moreover, adiabatic cooling is faster when the fluid is closer to the critical point.