Flux of high-LET cosmic-ray particles in manned space flight

On the Apollo and Skylab missions the high-energy heavy ion (HZE) flux was measured by means of plastic nuclear track detectors. Measurements involved the fluxes of high linear energy transfer (LET), particles with Z between 6 and 26 incident on astronauts and on several biological experiments. Partial results of these measurements are presented; the effects of shielding and solar modulation are discussed.-

Benton, E. V.↗

Physical dosimetric evaluations in the Apollo 16 microbial response experiment

Texts of high-energy multicharged particle, ultraviolet light, and galactic irradiation fluxes on exposed biological specimens aboard Apollo 16 are described. Passive nuclear track detectors, passive dosimeters, and thermoluminescent dosimeters, respectively, were used for the measurements. Biological phenomena studied ranged from lipolytic alpha toxin production in Bacillus thuringiensis to animal tissue invasion (of human hair by Trichophyton terrestre). Fluxes observed were lower than those recorded by detectors located in the Biostack and in the passive personnel dosimeters worn by the astronauts, suggesting a greater average shielding in the latter two environments.

Taylor, G. R.↗

On particle track detectors

Aqueous sodium hydroxide is widely used to develop charged particle tracks in polycarbonate film, particularly Lexan. The chemical nature of the etching process for this system has been determined. A method employing ultra-violet absorbance was developed for monitoring the concentration of the etch products in solution. Using this method it was possible to study the formation of the etching solution saturated in etch products. It was found that the system super-saturates to a significant extent before precipitation occurs. It was also learned that the system approaches its equilibrium state rather slowly. It is felt that both these phenomena may be due to the presence of surfactant in the solution. In light of these findings, suggestions are given regarding the preparation and maintenance of the saturated etch solution. Two additional research projects, involving automated techniques for particle track analysis and particle identification using AgCl crystals, are briefly summarized.

Benton, E. V.↗

The high energy multicharged particle exposure of the microbial ecology evaluation device on board the Apollo 16 spacecraft

The high energy multicharged cosmic-ray-particle exposure of the Microbial Ecology Evaluation Device package on board the Apollo 16 spacecraft was monitored using cellulose nitrate, Lexan polycarbonate, nuclear emulsion, and silver chloride crystal nuclear-track detectors. The results of the analysis of these detectors include the measured particle fluences, the linear energy transfer spectra, and the integral atomic number spectrum of stopping particle density. The linear energy transfer spectrum is used to compute the fractional cell loss in human kidney (T1) cells caused by heavy particles. Because the Microbial Ecology Evaluation Device was better shielded, the high-energy multicharged particle exposure was less than that measured on the crew passive dosimeters.

Benton, E. V.↗

Biocore experiment

The Apollo 17 biological cosmic ray experiment to determine the effect of heavy cosmic ray particles on the brain and eyes is reported. The pocket mouse was selected as the biological specimen for the experiment. The radiation monitors, animal autopsy and animal processing are described, and the radiation effects on the scalp, retina, and viscera are analyzed.

Bailey, O. T.↗

On charged particle tracks in cellulose nitrate and Lexan

Investigations were performed aimed at developing plastic nuclear track detectors into quantitative tools for recording and measuring multicharged, heavy particles. Accurate track etch rate measurements as a function of LET were performed for cellulose nitrate and Lexan plastic detectors. This was done using a variety of incident charged particle types and energies. The effect of aging of latent tracks in Lexan in different gaseous atmospheres was investigated. Range distributions of high energy N-14 particle bevatron beams in nuclear emulsion were measured. Investigation of charge resolution and Bragg peak measurements were carried out using plastic nuclear track detectors.

Benton, E. V.↗

High Z particle Apollo astronaut dosimetry with plastics

On Apollo missions, the individual astronauts' high Z particle exposure is measured by means of Lexan polycarbonate plastic. These layers form one component of the passive dosimetry packets worn in the constant wear garment. They serve as threshold type, high Z, charged particle track detectors, recording only the very highly ionizing particles. The detectors yield information on the particles' charge, energy, and direction of travel. This data, in turn, is used to obtain the track fluence, the stopping particle density as an integral Z distribution, and the particles' integral LET spectrum. Some of the data gathered on Apollo missions 8-13 is presented.

Benton, E. V.↗