Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “zone pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Bayesian inference for heterogeneous caprock permeability based on above zone pressure monitoring

The presence of faults/ fractures or highly permeable zones in the primary sealing caprock of a CO2 storage reservoir can result in leakage of CO2. Monitoring of leakage requires the capability to detect and resolve the onset, location, and volume of leakage in a systematic and timely manner. Pressure-based monitoring possesses such capabilities. This study demonstrates a basis for monitoring network design based on the characterization of CO2 leakage scenarios through an assessment of the integrity and permeability of the caprock inferred from above zone pressure measurements. Four representative heterogeneous fractured seal types are characterized to demonstrate seal permeability ranging from highly permeable to impermeable. Based on Bayesian classification theory, the probability of each fractured caprock scenario given above zone pressure measurements with measurement error is inferred. The sensitivity to injection rate and caprock thickness is also evaluated and the probability of proper classification is calculated. The time required to distinguish between above zone pressure outcomes and the associated leakage scenarios is also computed.

54 ENVIRONMENTAL SCIENCES↗

Probabilistic Assessment of Above Zone Pressure Predictions at a Geologic Carbon Storage Site

Carbon dioxide (CO2) storage into geological formations is regarded as an important mitigation strategy for anthropogenic CO2 emissions to the atmosphere. This study first simulates the leakage of CO2 and brine from a storage reservoir through the caprock. Then, we estimate the resulting pressure changes at the zone overlying the caprock also known as Above Zone Monitoring Interval (AZMI). A data-driven approach of arbitrary Polynomial Chaos (aPC) Expansion is then used to quantify the uncertainty in the above zone pressure prediction based on the uncertainties in different geologic parameters. Finally, a global sensitivity analysis is performed with Sobol indices based on the aPC technique to determine the relative importance of different parameters on pressure prediction. The results indicate that there can be uncertainty in pressure prediction locally around the leakage zones. The degree of such uncertainty in prediction depends on the quality of site specific information available for analysis. The scientific results from this study provide substantial insight that there is a need for site-specific data for efficient predictions of risks associated with storage activities. The presented approach can provide a basis of optimized pressure based monitoring network design at carbon storage sites.

54 ENVIRONMENTAL SCIENCES↗

Above zone pressure interpretation for leaky well characterization and its identification from leaky caprock/fault

Pressure transient analysis has long been used for reservoir characterization. Above-zone (AZ) pressure has been recently investigated for inferring leakage pathway characteristics in leakage events from subsurface injection operations. The recorded pressure in the AZ should be purely related to leakage and therefore it can be safely inverted to deduce leakage characteristics. It is crucial to evaluate fluid leakage through abandoned wells to plan for further measurements of leakage prevention. However, the recorded AZ leakage signal may not be related to leaky well(s). Therefore, identification and spatial investigation of well leakage is required for leakage evaluation. Here in this paper, we propose a pressure interpretation method for early detection of leaky pathways, applying two observation points in the AZ. We distinguish leaky well, fault and caprock based on their corresponding flow regime identification. We show that the pressure difference of the two observation wells can be applied as a proxy for unknown leakage rate, which is crucial for leakage identification as well as characterization. Results show that the estimated location of the leaky well, leakage coefficient, and the leakage rate are in good agreement with the actual values. The estimated leakage coefficient of the leaky well can be used to evaluate well leakage in multiphase systems such as carbon dioxide leakage in deep saline aquifers.

02 PETROLEUM↗

Systems for low frequency seismic and infrasound detection of geo-pressure transition zones

Methods for determining the existence and characteristics of a gradational pressurized zone within a subterranean formation are disclosed. One embodiment involves employing an attenuation relationship between a seismic response signal and increasing wavelet wavelength, which relationship may be used to detect a gradational pressurized zone and/or determine characteristics thereof. In another embodiment, a method for analyzing data contained within a response signal for signal characteristics that may change in relation to the distance between an input signal source and the gradational pressurized zone is disclosed. In a further embodiment, the relationship between response signal wavelet frequency and comparative amplitude may be used to estimate an optimal wavelet wavelength or range of wavelengths used for data processing or input signal selection. Systems for seismic exploration and data analysis for practicing the above-mentioned method embodiments are also disclosed.

58 GEOSCIENCES↗

High pressure floating zone growth and structural properties of ferrimagnetic quantum paraelectric BaFe{sub 12}O{sub 19}

High quality single crystals of BaFe{sub 12}O{sub 19} were grown using the floating zone technique in 100 atm of flowing oxygen. Single crystal neutron diffraction was used to determine the nuclear and magnetic structures of BaFe{sub 12}O{sub 19} at 4 K and 295 K. At both temperatures, there exist local electric dipoles formed by the off-mirror-plane displacements of magnetic Fe{sup 3+} ions at the bipyramidal sites. The displacement at 4 K is about half of that at room temperature. The temperature dependence of the specific heat shows no anomaly associated with long range polar ordering in the temperature range from 1.90 to 300 K. The inverse dielectric permittivity, 1/ε, along the c-axis shows a T{sup 2} temperature dependence between 10 K and 20 K, with a significantly reduced temperature dependence displayed below 10 K. Moreover, as the sample is cooled below 1.4 K there is an anomalous sharp upturn in 1/ε. These features resemble those of classic quantum paraelectrics such as SrTiO{sub 3}. The presence of the upturn in 1/ε indicates that BaFe{sub 12}O{sub 19} is a critical quantum paraelectric system with Fe{sup 3+} ions involved in both magnetic and electric dipole formation.

36 MATERIALS SCIENCE↗

SECARB Pressure Monitoring Data

Bottom-hole, above zone monitoring interval, and injection zone pressure data collected during the SECARB project in Cranfield, Mississippi to assess the relationship between pressure field and multiphase field. Submission includes 10-second interval data from Detailed Area of Study wells: CFU31-F1 (injector), CFU31-F2 (observation), CFU31-F3 (observation) and Ella G Lees no. 7 (observation) well located west of the DAS. Associated Publications: Joy, C. A., 2011, The effects of pressure variation and chemical reactions on the elasticity of the lower Tuscaloosa sandstone of the Cranfield Field Mississippi, The University of Texas at Austin, Master’s thesis, 97 p. Kim, S., and Hosseini, S. A., 2013, Above-zone pressure monitoring and geomechanical analysis of a field scale CO2 injection, Cranfield Mississippi, Greenhouse Gases: Science and Technology, doi:10.1002/ghg.1388. Kim, S., and Hosseini, S. A., 2017, Study on the ratio of pore-pressure/stress changes during fluid injection and its implications for CO2 geologic storage: Journal of Petroleum Science and Engineering, v. 149, p. 138-150, doi:10.1016/j.petrol.2016.10.037. Mathias, S. A., Gluyas, J. G., Gonzalez Martinez de Miguel, G. J., and Hosseini, S. A., 2011, Role of partial miscibility on pressure buildup due to constant rate injection of CO2 into closed and open brine aquifers: Water Resources Research, v. 47, W12525, 11 p., doi:10.1029/2011WR011051. Meckel, T. A., Zeidouni, M., Hovorka, S. D., and Hosseini, S.A., 2013, Assessing sensitivity to well leakage from three years of continuous reservoir pressure monitoring during CO2 injection at Cranfield, MS, USA: International Journal of Greenhouse Gas Control, [insert volume no., page numbers], doi:10.1016/j.ijggc.2013.01.019. Nicot, J.-P., Oldenburg, C. M., Bryant, S. L., and Hovorka, S. D., 2009, Pressure perturbations from geologic carbon sequestration: area-of-review boundaries and borehole leakage driving forces, in Energy Procedia (v. 1, no.1), Proceedings of 9th International Conference on Greenhouse Gas Control Technologies, GHGT9, 16–20 November, Washington DC, p. 47–54. Tao, Q., Bryant, S. L., and Meckel, T. A., 2013, Modeling above-zone measurements of pressure and temperature for monitoring CCS sites: International Journal of Greenhouse Gas Control, v. 18, p. 523–530, doi:10.1016/j.ijggc.2012.08.011.

above zone monitoring interval↗

High oxygen pressure floating zone growth and crystal structure of the metallic nickelates R4Ni3O10 ( R=La,Pr )

Single crystals of the metallic Ruddlesden-Popper trilayer nickelates R 4 Ni 3 O 10 ( R = La , Pr ) were successfully grown using an optical-image floating zone furnace under oxygen pressure ( p O 2 ) of 20 bar for La 4 Ni 3 O 10 and 140 bar for Pr 4 Ni 3 O 10 . Furthermore, a combination of synchrotron and laboratory x-ray single-crystal diffraction, high-resolution synchrotron x-ray powder diffraction and measurements of physical properties revealed that R 4 Ni 3 O 10 ( R = La , Pr ) crystallizes in the monoclinic P 2 1 / a ( Z = 2 ) space group at room temperature, and that a metastable orthorhombic phase ( Bmab ) can be trapped by postgrowth rapid cooling. Both La 4 Ni 3 O 10 and Pr 4 Ni 3 O 10 crystals undergo a metal-to-metal transition (MMT) below room temperature. In the case of Pr 4 Ni 3 O 10 , the MMT is found at 157.6 K. For La 4 Ni 3 O 10 , the MMT depends on the lattice symmetry: 147.5 K for Bmab vs 138.6 K for P 2 1 / a . Lattice anomalies were found at the MMT that, when considered together with the pronounced dependence of the transition temperature on subtle structural differences between Bmab and P 2 1 / a phases, demonstrate a not insignificant coupling between electronic and lattice degrees of freedom in these trilayer nickelates.

36 MATERIALS SCIENCE↗

High-resolution simulation of free-surface flow and tracer retention over streambeds with ripples

This study presents a novel high-resolution simulation of free-surface flow and tracer retention over a streambed with ripples based on varying ripple morphologies, surface hydraulics and the transport of a tracer pulse from surface water to surface dead zone. For the simulations, the computational fluid dynamics (CFD) model OpenFOAM was used to solve the three-dimensional Navier-Stokes equations in combination with an implemented transport equation. Pressure gradients at the streambed were used to account for hyporheic exchange, assuming water flow from high pressure zones to low pressure zones. Flow velocities, ripple sizes and spacing showed to significantly affect these pressure gradients, but also the transport of a passive tracer at the streambed, which was not investigated so far. Due to the velocity field, large parts of the tracer mass were transported alongside the main stream above the ripples. Tracer mass reaching the space between the ripples was temporarily retained due to low velocities and recirculations. It was shown that the retention is depending on the ripple size and space between the ripples as well as on the flow velocity. Decreasing ripple sizes and higher flow velocities lead to a smaller tracer retention. Furthermore we showed that the ripple length to height ratio controls the generation of recirculation zones which affect the residence time of the tracer significantly. Ripple spacing leads to temporarily higher tracer concentration at the streambed, but smaller tracer retention. We conclude that the impact of the streambed morphology on the hydraulics in combination with tracer retention should be addressed for a comprehensive understanding of compound movement, exchange and transformation within the hyporheic zone.

54 ENVIRONMENTAL SCIENCES↗

Explosion behavior investigation and safety assessment of large-format lithium-ion pouch cells

We report large-format lithium-ion (Li-ion) batteries with high energy density for electric vehicles are prone to thermal runaway (or even explosion) under abusive conditions. In this study, overcharge induced explosion behaviors of large-format Li-ion pouch cells with Li[Ni 0.8 Co 0.1 Mn 0.1 ]O 2 cathode at different current rates (C-rates) (0.5C, 1C, 2C) were investigated. The explosion characteristics of the cells were elucidated by discussing the evolution of the cell voltage, the surface temperature and the shock wave pressure. Generally, the whole overcharge process could be divided into four stages according to the evolution of several key parameters and the overcharge behaviors; the overcharge C-rate has a great influence on cells’ thermal behaviors. The experimental results showed that the thermal runaway process of Li-ion cells caused by overcharging consisted of two kinds of explosions, physical explosion and chemical explosion. The existence of observable negative pressure zone in the pressure curves indicated that the Li-ion cells are not a self-supplying oxygen system during the explosion. Further, the explosion dynamics parameters were matched. An explosion TNT-equivalent conversion strategy that depended on the pressure of the shock wave was utilized to evaluate the released energy and its hazards. In addition, with respect to the overcharge of Li-ion pouch cells, a safety assessment method and a safety management method were proposed based on the explosion behaviors. From the perspective of battery safety, this study is of great significance for the safety design of Li-ion cells and can provide guidance for engineers to optimize the safety function of battery packs.

25 ENERGY STORAGE↗

Alabama Department of Environmental Management Temporary Abandonment Report [Well Names/ID: D4-13]

Two temporarily abandoned Citronelle Oil Field wells (D 4-13 and D 4-14) located up-dip from the D 9- 7#2 injection well (approximately 3,500 feet away) and outside of the area of review (Figure 1) were designated to be used for the monitoring activities associated with the SECARB Anthropogenic Test. Both wells were recompleted prior to the project, which included perforating the D 4-14 within the injection zone and the D 4-13 above the proposed confining unit. The D-4-13 well provides above-zone pressure monitoring in a perforated interval from 9,186 feet to 9,188 feet, with the gauge landing nipple at 9,111 feet. In-zone pressure monitoring occurs in the D-4- 14, perforated from 9,420 feet to 9,422 feet. The gauge landing nipple was set at 9,375 ft. Following the completion of the project These wells were converted back to their original condition for oilfield operations.

01 COAL, LIGNITE, AND PEAT↗

Uncertainty quantification for evaluating the impacts of fracture zone on pressure build-up and ground surface uplift during geological CO₂ sequestration

A series of numerical test cases reflecting broad and realistic ranges of geological formation and preexisting fault properties was developed to systematically evaluate the impacts of preexisting faults on pressure buildup and ground surface uplift during CO₂ injection. Numerical test cases were conducted using a coupled hydro-geomechanical simulator, eSTOMP (extreme-scale Subsurface Transport over Multiple Phases). For efficient sensitivity analysis and reliable construction of a reduced-order model, a quasi-Monte Carlo sampling method was applied to effectively sample a high-dimensional input parameter space to explore uncertainties associated with hydrologic, geologic, and geomechanical properties. The uncertainty quantification results show that the impacts on geomechanical response from the pre-existing faults mainly depend on reservoir and fault permeability. When the fault permeability is two to three orders of magnitude smaller than the reservoir permeability, the fault can be considered as an impermeable block that resists fluid transport in the reservoir, which causes pressure increase near the fault. When the fault permeability is close to the reservoir permeability, or higher than 10⁻¹⁵ m² in this study, the fault can be considered as a conduit that penetrates the caprock, connecting the fluid flow between the reservoir and the upper rock.

CO₂ geological sequestration↗

Air Leakage and Air Transfer Between Garage and Living Space

This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the Baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air Leakage and Air Transfer Between Garage and Living Space

This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Air Leakage and Air Transfer Between Garage and Living Space, Waldorf, Maryland (Fact Sheet)

This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the Baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Solutions Case Study: Air Leakage and Air Transfer Between Garage and Living Space, Waldorf, Maryland

In this project, Building Science Corporation worked with production homebuilder K. Hovnanian to evaluate air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multipoint fan pressurization tests and additional zone pressure diagnostic testing measured the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

air leakage↗

Low-cost Radon Reduction Pilot Study

The U.S. Department of Energy's Building America research team Partnership for Advanced Residential Retrofits conducted a primary scoping study on the impact of air sealing between the foundation and the living space on radon transport reduction across the foundation and living space floor assembly. Fifteen homes in the Champaign, Illinois, area participated in the study. These homes were instrumented for hourly continuous radon measurements and simultaneous temperature and humidity measurements. Blower door and zone pressure diagnostics were conducted at each house. The treatments consisted of using air-sealing foams at the underside of the floor that separated the living space from the foundation and providing duct sealing on the ductwork that is situated in the foundation area. The hypothesis was that air sealing the floor system that separated the foundation from the living space should better isolate the living space from the foundation; this isolation should lead to less radon entering the living space from the foundation. If the hypothesis had been proven, retrofit energy-efficiency programs may have chosen to adopt these isolation methods for enhanced radon protection to the living space.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Minimizing exposure to legacy wells and avoiding conflict between storage projects: Exploring area of review as a screening tool

Elevated pressure from large-volume injection is a key driver of risk and project cost. If transmissive features (e.g., non-isolating wells or fracture systems) are present, increased injection-zone pressure can drive fluids from depth toward protected freshwater resources. In US Carbon Capture and Storage (CCS) law, the area at risk is known as the Area of Review (AoR). The size and number of potentially transmissive features to be evaluated and possibly remediated or managed is a function of the size and location of the AoR. The size of the AoR depends on several variables, including properties of the injection zone, properties of protected resources, and injection rate and duration. Evaluation of the intersection of these variables across a portfolio of sites highlights the injection zone depth and boundary conditions as top-level controls. Deep injection, use of multiple stacked injection zones, reduced injection rate and choice of injection well location can all be used to minimize AoR and the number of potentially transmissive features within it. Here, we introduce the concept of pressure space (defined as connected pore volume times pressure) as the key subsurface commodity for CO 2 storage and we suggest that it forms a more robust basis for leasing and regulation than pore space alone.

58 GEOSCIENCES↗

Static solutions in Einstein-Chern-Simons gravity

In this paper we study static solutions with more general symmetries than the spherical symmetry of the five-dimensional Einstein-Chern-Simons gravity. In this context, we study the coupling of the extra bosonic field h{sup a} with ordinary matter which is quantified by the introduction of an energy-momentum tensor field associated with h{sup a}. It is found that exist (i) a negative tangential pressure zone around low-mass distributions (μ < μ{sub 1}) when the coupling constant α is greater than zero; (ii) a maximum in the tangential pressure, which can be observed in the outer region of a field distribution that satisfies μ < μ{sub 2}; (iii) solutions that behave like those obtained from models with negative cosmological constant. In such a situation, the field h{sup a} plays the role of a cosmological constant.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗