Engineering PapersSearch

SEARCH · Engineering Papers

Results for “xe-127”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

A target for production of radioxenons

A liquid cesium target has been developed which permits the production and identification of the neutron deficient isotopes of xenon. The thick target yields of Xe-127 and Xe-129 m were measured for proton energies between 28 and 40 MeV. Production of Xe-129 m, as indicated by the presence of a 196 keV line in the gamma ray spectra, occurred at all proton energies; Xe-127 was produced at proton energies above 33 MeV. Both accumulated on the target with the same time constant, and the cross sections were comparable in magnitude. The radioxenons were removed from the target by a stream of carrier gas so that chemical separation was unnecessary.

Blue, J. W.

A target design for irradiation of NaI at high beam current

A solution to the targetry problems encountered when the iodine nucleus is a target for cyclotron irradiation is given as a target design. A target based on this design was used in 30 microampere irradiations of 46 MeV alpha particles for one-half hour without significant damage. Such an irradiation produces 6 to 7 mCi of Cs-129. This target should also be considered for cyclotron production of the radioisotopes Cs-127, I-123, and Xe-127.

Blue, J. W.

A target design for irradiation of NaI at high beam current.

A solution to the targetry problems encountered when the iodine nucleus is a target for cyclotron irradiation is given as a new target design. A target based on this design has been used in 30 microampere irradiations of 46 MeV alpha particles for one-half hour without significant damage. Such an irradiation produces 6 to 7 mCi of Cs-129, an isotope useful in nuclear medicine. This target should also be considered for cyclotron production of the radioisotopes Cs-127, I-123, and Xe-127.

Blue, J. W.

Gamma ray spectrometer experiment, NaI(Tl) detector crystal activation

Preliminary results are presented of data on the extent of the cosmic ray-induced activity obtained by a sodium iodide thallium-activated crystal flown onboard the Apollo 17 command module. Qualitative identification is reported for the following: Na-24, I-123, I-124, I-125, I-126, and Xe-127.

Trombka, J. I.

A target for production of radioxenons

A liquid cesium target has been developed which allows the production and separate identification of the neutron deficient isotopes of xenon. The present report describes irradiations utilizing 34 to 41 MeV protons to produce millicurie quantities of Xe-127 and Xe-129m. At higher energies, however, the target could be used without modification to produce xenon isotopes as light as 119.

Blue, J. W.

127 Xe quantification method development and intercomparison exercise

Monitoring of the atmosphere for fission products ( 131m Xe, 133m Xe, 133 Xe, and 135 Xe) is performed by various laboratories to detect nuclear explosions. Quantification of 127 Xe is not routinely performed by laboratories measuring atmospheric radioxenon because it is not a fission product. 127 Xe was recently detected by a ground-based beta-gamma air monitoring system. When measured using beta-gamma coincidence detector systems, such as those in use on the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty (CTBT), 127 Xe can interfere with the quantification of fission product radioxenon due to overlap of the 127 Xe beta-gamma coincidence signatures with those of fission product radioxenon. Here, this work demonstrates quantification of 127 Xe at different laboratories with different measurement techniques. Production and purification of 127 Xe was performed by neutron activation of enriched 126 Xe. The purified 127 Xe was then split between laboratories, and detection and quantification methods were developed. At Idaho National Laboratory, a quantification method involving high purity germanium detectors was devised that included self-attenuation correction. At AWE, a beta-gamma coincidence counting method, as used in support of the IMS, was modified to enable the measurement and analysis of the 127 Xe samples. Corrections were made for self-attenuation, which showed a strong xenon volume dependency, for some coincidence signatures. The gas sample activity concentration was used as the comparison metric and it showed excellent agreement between the methods.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P

Analysis of 127 Xe tracer measurements using a net counts method

A suite of measurement systems were deployed as part of the Physical Experiment 1 series of experiments, which involved detonating chemical explosives along with radionuclide tracers in an underground cavity, at the Nevada National Security Site (NNSS) in the United States. One of the radionuclide tracers, 127 Xe was released from the containment following the explosion and detected on a SAUNA Q B sampler situated approximately 3.5 km away. The system uses a beta-gamma coincidence detector system to measure fission product radioisotopes of xenon relevant to nuclear explosion monitoring. In this work we use the coincidence measurement data to analyse and interpret the results from the SAUNA Q B system, to calculate the measured 127 Xe activity concentration(s).

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P