Engineering PapersSearch

SEARCH · Engineering Papers

Results for “x-ray detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Gepta-EX: a multi-channel germanium detector for X-ray absorption fine structure

Fluorescence-mode X-ray absorption spectroscopy (XAS) at high photon energies requires detectors with high stopping power and excellent energy resolution to measure weak element-specific signals. Traditional silicon-based detectors suffer from poor efficiency above ∼20 keV, while most high-Z materials such as cadmium telluride, cadmium zinc telluride, and gallium arsenide have focused predominantly on imaging applications with limited spectroscopic resolution. In contrast, germanium combines excellent stopping power with superior intrinsic energy resolution due to its low Fano factor and favorable charge transport properties, making it ideal for high-resolution spectroscopy in the 15 keV to 100 keV range. To address these requirements, we report on the development, fabrication, and performance evaluation of Gepta-EX, a compact multi-channel high-purity germanium (HPGe) detector system for fluorescence-mode XAS. The Gepta-EX system features a monolithic seven-channel HPGe pixel array integrated with low-noise CUBE charge-sensitive preamplifiers, housed within a thermally isolated compact cryostat operating near 90 K. The detector achieves energy resolutions of 218 eV at 5.9 keV (from a 55 Fe source) and 373 eV at 59.5 keV (from a 241 Am source), with uniform performance across all channels. By avoiding the escape peak interference commonly associated with silicon detectors and providing stable, high-resolution performance, Gepta-EX represents a powerful tool for high-energy X-ray spectroscopy.

36 MATERIALS SCIENCE

New perspectives on materials and device dynamics using time-resolved full-field diffraction X-ray imaging

Understanding how materials evolve during synthesis, processing, or device operation requires experimental access to structural dynamics across wide ranges of length and time scales, often in bulk samples or even within packaged devices. Time-resolved full-field diffraction X-ray microscopy has recently emerged as a powerful way to meet this need by combining the penetration and structural sensitivity of X-ray diffraction with objective-lens-based magnification, sensitive high-resolution X-ray imaging detectors, and pump-probe and real-time imaging strategies. Advances in full-field X-ray diffraction microscopy, often termed dark-field X-ray microscopy (DFXM), enable simultaneous imaging of extended fields of view while retaining crystallographic selectivity. Time-resolved DFXM promises to enable advances in materials processing and dynamics, electrochemical and photochemical processes, and the design of electronic devices. This Perspective summarizes the key instrumental concepts that define the performance of these methods, including the choice of imaging optics, detector considerations, and the impact of source time structure at synchrotron light sources and X-ray free-electron lasers (XFELs). We discuss the simultaneous use of complementary imaging modes that are increasingly used in practice. The early demonstrations of the potential of time-resolved DFXM include real-time defect and grain-boundary dynamics during metal annealing, stroboscopic imaging of functional devices with high strain sensitivity, and ultrafast pump-probe implementations at XFELs that directly visualize acoustic-wave propagation and energy dissipation in bulk crystals.

Dark-field X-ray microscopy

Adapting High-Resolution X-Ray Microcalorimeter Spectrometers to Transform MFE Plasma Diagnostics

The aim of this project was to begin the transformation of magnetic fusion energy (MFE) X-ray diagnostics by applying detector technology developed over the past several decades by the astrophysics community. We installed and operated an X-ray microcalorimeter detector system under fusion-relevant plasma conditions at the Madison Symmetric Torus (MST). X-ray microcalorimeter spectrometers combine the best characteristics of instrumentation currently available on fusion devices: the high spectral resolution of crystal spectrometers (2 eV) and broadband coverage provided by pulse-height analysis systems. These spectrometers have small port-access requirements, a key advantage for future MFE experiments. This new plasma diagnostic technique will satisfy the need for multispecies impurity ion data by providing absolute measurements of impurity core accumulation, and it will provide the core impurity ion temperature. This project was a joint effort between Lawrence Livermore National Laboratory (LLNL) and researchers at the Wisconsin Plasma Physics Laboratory (WiPPl) at the University of Wisconsin–Madison (UW–Madison). Megan E. Eckart is the principal investigator at LLNL, which is funded separately from UW–Madison. This final report fulfills the reporting obligation of the UW–Madison effort.

Den Hartog, Daniel J. [Department of Physics, Univ

Optimization of X-ray Absorbers for High-Resolution TES Detectors in NewATHENA X-IFU

NewATHENA’s X-ray Integral Field Unit (X-IFU) uses a large-format array of Transition Edge Sensor (TES) microcalorimeters coupled with absorbers made of gold and bismuth providing 4 eV FWHM resolution up to 7 keV in the 0.2- 12 keV band. X-ray absorbers must be thick enough for photon absorption, maintain low heat capacity for energy resolution, and have good thermalization properties. The X-IFU requires total Quantum Efficiency (QE) of 96%, 87%, and 63% at 1, 7, and 9.5 keV, respectively. Optimal thicknesses are 1.05 µm gold and 5.5 µm bismuth to achieve 0.731 pJ/K at 90 mK and 87% QE at 7 keV. While typical TES absorbers are 3-4 µm thick, producing the required 5.5 µm Bi absorbers via standard electroplating creates enlarged grains and surface roughness. The increased roughness and grain size variability produced with our standard recipe have resulted in instances of 1) low energy spectral tails 2) spectral broadening of the energy resolution and 3) thermal shorts between pixels when a large grain bridges the gap between absorbers. In this study, we have introduced a new fabrication process and altered the morphology of the thick Bi through changes in the electroplating process. The process changes are intended to address all three issues as well as reduce particulate contamination observed on the finished detector arrays.

Absorber

Measurement of low energy characteristic X-rays emitted present in U-10Mo HALEU alloy fuel

Advance high density monolithic alloy HALEU fuels have been scanned with a silicon drift detector scanning system to measure low-energy characteristic X-rays emitted by uranium daughters, as well as zirconium present as a foil diffusion barrier. Four peaks were measured across the surfaces of three plates, and are consistent with other thorium and protactinium peaks present in depleted uranium samples that are induced by the decay of 235 U and 238 U. Of the four peaks detected, three are dominated by the decay of 235 U, and one peak at 15.70 keV covers two characteristic X-rays from the zirconium diffusion barrier (Kα 1 ) and from a 231 Th 15.62 keV X-ray induced by 235 U α-decay. The low energies of these lines suggest that they are mostly emitted from the fuel meat surface, and the poor counting statistics caused by strong self-attenuation make these data a poor candidate for 235 U/ 238 U ratio analysis. We suggest, then, that these X-rays could be used for passive measurement of variations in the cladding thickness of these fuels to complement manual thickness measurement methods.

HALEU

Lunar accelerometer network gravitational observatory (LANGO)

With ground-based interferometers detecting hundreds of gravitational-wave (GW) events, GW astronomy has continued to blossom. U.S. and European scientists are developing plans to construct third-generation ground-based interferometers. ESA has proceeded through the mission formulation phase of space-based interferometer in a lower-frequency band, 10 –4 –0.1 Hz. Despite all these exciting developments, there is still a missing frequency band, 0.1–10 Hz. This mid-frequency band is rich with interesting astrophysical events. Coalescence and merger of intermediate-mass black holes (IMBHs) will occur in this frequency band. Coalescing stellar-mass BHs will pass through this frequency band days before they reach the frequency band of LIGO and Virgo. Detection of such signals would enable a mid-frequency detector to issue an advance notice to the high-frequency GW detectors, as well as to optical, x-ray and γ-ray telescopes. We propose Lunar Accelerometer Network Gravitational Observatory (LANGO) to detect GWs in this frequency band. In the first phase (LANGO 1), we propose to deploy four ambient-temperature (250 K) accelerometers in the tetrahedral or in a square configuration on the hemisphere facing the Earth. After successful operation at 250 K, LANGO would be upgraded to a cryogenic (4 K) version with over two orders of magnitude increased sensitivity (LANGO 2), with coherent rejection of seismic noise implemented. LANGO is a full-tensor detector, capable of determining the source direction and wave polarization. Each test mass (TM) is suspended as a pendulum with resonance frequency ∼ 0.01 Hz, thus is only weakly coupled to the lunar surface horizontally. LANGO is designed to detect the relative motion of globally separated, nearly free, TMs by using the Moon as a large quiet platform. LANGO 1 and 2 accelerometers aim at sensitivities ⩽ 10 –11 m s –2 Hz –1/2 and ⩽ 10 –13 m s –2 Hz –1/2 in the horizontal axes over the frequency band of 1 mHz–10 Hz, which yield GW sensitivities 1.1 x 10 -21 Hz -1/2 and 3.8 x 10 -24 Hz -1/2 at 1 Hz, respectively. The LANGO accelerometers will be 10 3 –10 5 times more sensitive than Apollo seismometers. With such sensitivity, LANGO will also make great contribution to the advancement of lunar geophysics.

79 ASTRONOMY AND ASTROPHYSICS

Light-tight Skipper-CCDs for X-Ray Detection in Space

Skipper Charge-Coupled Devices (skipper-CCDs) are pixelated silicon detectors with deep sub-electron resolution. Their radiation hardness and capability to reconstruct energy deposits with unprecedented precision make them a promising technology for space-based X-ray astronomy. In this scenario, optical and near-infrared photons may saturate the sensor, distorting the reconstructed signal. We present a light-tight shield for skipper-CCDs to suppress optical backgrounds while preserving X-ray detection efficiency. We deposited thin aluminum layers on the CCD surface using an e-beam evaporator and evaluated their blinding performance across wavelengths from 650 to 1000 nm using a monochromator, as well as the X-ray transmission using an 55 Fe source. We find that 50 and 100 nm layers provide >99.6% light suppression, with no efficiency loss for 5.9 and 6.4 keV X-rays. In addition, we used Geant4 simulations to extend these results to a broader energy range and quantify the efficiency loss for different aluminum thicknesses. Results show that thin aluminum coatings are an effective, low-cost solution for optical suppression in skipper-CCDs intended for X-ray detection and space instrumentation.

79 ASTRONOMY AND ASTROPHYSICS

Energy response characterization of current-mode MeV Cherenkov aerogel detectors

Current-mode Cherenkov aerogel detectors have been used to measure time resolved spectra of MeV radiographic x-ray sources and have been considered to replace gas Cherenkov systems. The simulations of the Cherenkov response of aerogel detectors have uncertainties in how to model the complex structure of aerogels. Data from three sites—the Idaho electron beam, the Los Alamos Site electron beam and microtron sources at Los Alamos—have been used to calibrate the relative energy response of 15 aerogels, varying in density from 10 to 430 mg/cm 3 , from incident electrons with energies from 1 to 12 MeV. Detector simulations need to introduce density variation in the aerogels to match the collected data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Part-scale evolution of fine-scale microstructural heterogeneity in solid-state additive manufacturing

Current solid-state additive manufacturing methods, refined through costly and time-consuming trial and error, have spurred interest in computational models that replicate material behavior under typical thermomechanical conditions (e.g., strain-rate ~ 102 s−1). These models, however, struggle to capture time-dependent microstructural evolution. In this work, Additive Friction-Stir Deposition (AFSD) is used as a representative case study for part-scale quantification of microstructure evolution at a fine spatial resolution (200 μm) by examining a liquid-nitrogen-cooled stop-action build via energy-dispersive X-ray diffraction coupled with a multi-channel detector. These results inform modeling efforts by linking process asymmetry to stored plastic strain, residual elastic strain, and texture development, and unlike current state-of-the-art characterization methods (e.g., EBSD or neutron diffraction), this approach provides both the spatial resolution and collection efficiency necessary to quantify fine-scale microstructural heterogeneity over large component volumes. As such, this technique provides essential validation data for computational models, e.g., crystal plasticity, enabling future prediction of heterogeneous behavior in AFSD and other additive manufacturing processes.

Franz, Cole [ORNL] (ORCID:0000000213465881)

Toward Large Field-of-view X-ray Spectrometers with Magnetic Microcalorimeters

A future X-ray telescope mission like Lynx, a X-ray flagship mission concept, requires a large field of view, high energy resolution, and high spatial resolution. The Magnetic Microcalorimeter (MMC) detectors we are developing for such a mission feature a 5-arcminute field of view, approximately 100,000 pixels, each spanning 0.5–1 arcsecond. These detectors require the readout of 8,000 sensors. Three different array types have been designed to meet scientific goals, two of which utilize thermal multiplexing to reduce the number of readout channels in a scheme called “Hydra.” We are currently fabricating detectors on a recently completed buried wiring wafer with connections to every sensor. The sensors are read out using a microwave multiplexer (μMUX) with flux ramp modulation. A single μMUX can read out approximately 1,000 sensors with only two feed lines. We will report on the test of the first two-dimensional μMUX chip, consisting of 78 resonators. μMUX chips that pass screening will be directly bonded to MMC array chips using indium bump bonding. In parallel, we have tested a kinetic inductance traveling wave parametric amplifier (KI-TWPA) to amplify signals at low temperatures. The KI-TWPA exhibits extremely low internal noise, approaching the standard quantum limit. Since the energy resolution of an MMC is primarily limited by the readout system, the KI-TWPA is an ideal amplifier for MMCs with μMUX readout. We recently measured the readout noise of a μMUX with a KI-TWPA, demonstrating its capability for reading out MMC arrays. We present the design and fabrication of the latest MMC detectors, along with its readout performance.

Magntic Microcalorimeters

BM3DORNL

BM3DORNL is a high-performance, open-source library for removing streak and ring artifacts from computed-tomography (CT) data, developed for neutron imaging at Oak Ridge National Laboratory's Spallation Neutron Source (VENUS beamline) and applicable to X-ray CT as well. Ring artifacts — concentric rings in reconstructed slices caused by detector pixel-to-pixel response non-uniformities — appear as vertical streaks in the sinogram and degrade both image quality and quantitative analysis. BM3DORNL operates in the sinogram domain using an adaptation of the BM3D (block-matching and 3D collaborative filtering) algorithm (Dabov et al., 2007). It provides a dedicated streak-removal mode, a true multi-scale BM3D variant (after Mäkinen et al., 2021) that suppresses wide streaks single-scale methods miss, and an alternative Fourier–SVD method (~2.6× faster) combining FFT-based energy detection with rank-1 SVD. The computationally intensive core is implemented in Rust with parallel (Rayon) block matching, integral-image pre-screening, and optimized transforms, and is exposed through a simple Python API (with an optional GUI) so it integrates directly into existing tomography reconstruction pipelines. It processes both 2D sinograms and 3D sinogram stacks, is pip-installable for Linux and macOS, and is documented at https://bm3dornl.readthedocs.io.

Zhang, Chen [Oak Ridge National Laboratory (ORNL),

High EneRgy Observatory for Imaging X-rays (HEROIX) Mission Concept

The High EneRgy Observatory for Imaging X-rays (HEROIX) is a next-generation broadband X-ray space telescope concept under development as a Medium-Class Explorer mission. Building on more than three decades of replicated NiCo shell technology at NASA’s Marshall Space Flight Center, HEROIX will deliver 5 arcsecond half-power-diameter imaging resolution in the hard X-ray band. The observatory will incorporate four co-aligned telescopes with advanced multilayer coatings, extending the bandpass into the hard X-ray regime and providing an integrated effective area of 380 cm² at 30 keV. A suite of focal plane detectors will enable imaging capability throughout its 1–80 keV bandpass. This combination of angular resolution and high-energy coverage will open new windows into non-thermal processes in extreme astrophysical environments. HEROIXwill deliver transformative science, advancing the astrophysics community’s understanding of supernova physics, the X-ray binary population of the Galactic Center, accretion-driven galaxy evolution, and the origin of the Cosmic X-ray Background.

Nick Thomas

Ground calibration plan for the Athena/X-IFU microcalorimeter spectrometer

The X-ray Integral Field Unit is the X-ray imaging spectrometer on board one of ESA’s next large missions, Athena. Athena is set to investigate the theme of the Hot and Energetic Universe, with a launch planned in the late-2030s. Based on a high-sensitivity transition edge sensor (TES) detector array operated at very low temperature (50 mK), X-IFU will provide spatially resolved high-resolution spectroscopy of the X-ray sky in the 0.2 to 12 keV energy band, with an energy resolution goal of 4 eV up to 7 keV [3 eV design goal]. This work presents the current calibration plan of the X-IFU. It provides the requirements applicable to the X-IFU calibration, describes the overall calibration strategy, and details the procedure and sources needed for the ground calibration of each parameter or characteristics of the X-IFU.

47 OTHER INSTRUMENTATION

Fast and bright scintillators for ultrafast materials dynamics using 4th generation synchrotron

We present recent advances in fast and bright scintillators for ultrafast X-ray phase contrast imaging of dynamic materials experiments at the upgraded Advanced Photon Source (APS-U), a fourth generation synchrotron. APS-U enables hard X-ray imaging at frame rates of at least 13 MHz (corresponding to 77 ns or shorter interframe intervals), creating a new need for scintillators with faster response and higher light output than lutetium yttrium oxyorthosilicate (LYSO). For indirect imaging and diffraction with ultrafast cameras, commercial lanthanum bromide (LaBr3) and cerium bromide (CeBr3) are promising candidates. These materials exhibit decay times approximately a factor of two shorter than LYSO (around 40 ns) and lutetium oxyorthosilicate (LSO), while maintaining comparable light yield per incident X-ray photon. However, their implementation at APS-U requires addressing several challenges, including material limitations due to hygroscopicity, efficient optical coupling to imaging systems, and high quantum efficiency for conversion of scintillation light, predominantly at wavelengths below 400 nm, into detectable electronic signals. We report results from material characterization, detector integration and packaging, and beamline experiments of materials with impact. In addition, emerging scintillator classes, including perovskites and high-entropy materials, are discussed as potential alternatives for next-generation ultrafast X-ray diagnostics.

Wang, Zhehui [Los Alamos] (ORCID:0000000178264063)

Visualization of Thermal and Strain Dynamics in X-ray Optics by Time-Resolved Rocking Curve Imaging

The absorption of intense X-ray pulses from free-electron lasers by X-ray crystal optics triggers rapid thermal and mechanical responses, including lattice compression, expan- sion, and strain-wave propagation, which dynamically modify diffraction conditions and wavefront properties. These effects pose significant challenges for next-generation high- repetition-rate X-ray sources, particularly for crystal monochromators used in XFEL beam- lines and self-seeding. Here, we demonstrate time-resolved rocking curve imaging (TrRCI) of X-ray Bragg optics with high spatial resolution (6.4 μm) and sub-1-μrad angular resolu- tion, enabling direct visualization of lattice dynamics from nanoseconds to microseconds. By combining a high-flux beamline at SPring-8, a scintillator-coupled sCMOS detector, and a synchronized femtosecond laser system, we capture lattice dynamics induced by tran- sient laser heating with a strain sensitivity on the order of 10−6 . Our results reveal transient lattice deformation and the propagation of laser-induced strain waves over millimeter-scale distances. This approach provides experimental benchmarks for understanding heat-load effects in high-repetition-rate X-ray optics.

Source record

The next-generation particle x-ray temporal diagnostic for simultaneous time-resolved measurements of nuclear-burn and x-ray emission histories in support of basic-science and inertial confinement fusion experiments at OMEGA

The next-generation Particle X-ray Temporal Diagnostic (PXTD) has been implemented for simultaneous measurements of x-ray, charged particle, and neutron emission histories from a wide range of inertial confinement fusion and high energy density plasma experiments, demonstrating excellent timing accuracy and greatly improved experimental flexibility. The key changes to the previously fielded system are a redesigned set of thin foil filters in front of the scintillators and individual neutral density filters for each region of the detector. The fully implemented PXTD system can provide unique information about the evolution of ion and electron temperatures in multi-ion and kinetic-physics experiments, proton radiography experiments, and DT experiments executed at the OMEGA facility. The system has 35 ps time resolution and negligible relative timing uncertainty between measured emission history signals. The first use of the upgraded four-channel PXTD system during a set of D 3 He-filled silica-glass implosions on OMEGA captured electron temperatures with a minimum uncertainty of 0.5 keV and resolved both the relative timings and widths of neutron, proton, and x-ray peaks within a single recorded image.

Evans, T. E. [Massachusetts Inst. of Technology (M

In situ cryogenic characterization of proton damage in thick p-channel skipper CCDs

Skipper charge-coupled devices (CCDs) are an offshoot of standard silicon pixel detectors and are capable of performing repeated non-destructive charge measurements, enabling deeply sub-electron readout noise. This capability has opened the door to single-photon counting from the near-infrared ($\sim$1.1 $μ$m) to the soft X-ray (several keV), making these devices strong candidates for future astronomical instruments operating in the photon-starved limit. Furthermore, the p-channel architecture used to fabricate Skipper CCDs on n-type silicon has been demonstrated to have an increased hardness to the intense radiation environment of space. Building upon previous irradiation campaigns on room-temperature sensors, here we describe the first radiation-hardness tests of p-channel skipper CCDs at their cryogenic operating temperatures. We assess the performance of the floating-gate output stage and global CCD parameters (charge transfer inefficiency, dark current, hot pixels, and charge traps). We find that these devices maintain excellent performance after displacement damage doses equivalent to ${\sim}$10 years at the Earth/Sun L2 Lagrange point, demonstrating for the first time that these sensors remain radiation-hard in realistic deep-space thermal and radiation environments.

Roach, Brandon M. [Chicago U., KICP] (ORCID:000000

Taking three-dimensional x-ray diffraction (3DXRD) from the synchrotron to the laboratory scale

Three-dimensional x-ray diffraction (3DXRD), a rotating x-ray diffraction technique, is a powerful tool for studying the micromechanical behavior of polycrystalline materials, capable of measuring the volume, position, orientation, and strain of thousands of grains simultaneously. However, its application has been historically limited to synchrotron facilities. Here, we present the first demonstration of laboratory-scale 3DXRD (Lab-3DXRD) using a liquid-metal-jet source. Lab-3DXRD achieves accuracy comparable to synchrotron-based 3DXRD, as validated against laboratory diffraction contrast tomography (LabDCT) and synchrotron-3DXRD. Over 96% of the grains detected with Lab-3DXRD are cross-validated, particularly for coarse grains (> ~60 μm), while the results suggest that finer grains should be accessible by taking advantage of high-efficiency detectors. We further demonstrate that its sensitivity to finer grains is enhanced by incorporating pre-characterization into the analysis. This study establishes Lab-3DXRD as a practical alternative to synchrotron techniques, making 3DXRD accessible to a wider range of academic and industrial researchers.

characterization and analytical techniques