SEARCH · Engineering Papers
Results for “white beam”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
ARCS White Beam Vanadium Normalization Data for SNS Cycle 2023B
A data set used to normalize the detector response of the ARCS instrument see ARCS_256693.md in the data set for more details.
ARCS White Beam Vanadium Normalization Data for SNS Cycle 2015B
A data set used to normalize the detector response of the ARCS instrument see ARCS_58221.md in the data set for more details.
ARCS White Beam Vanadium Normalization Data for SNS Cycle 2025A
A data set used to normalize the detector response of the ARCS instrument. See ARCS_295641.md in the data set for more details.
ARCS White Beam Vanadium Normalization Data for SNS Cycle 2026A
A data set used to normalize the detector response of the ARCS instrument. See ARCS_336659.md in the data set for more details.
White-beam X-ray diffraction and radiography studies on high-boron-containing borosilicate glass at high pressures
Abstract not provided
LauePt, a graphical-user-interface program for simulating and analyzing white-beam x-ray diffraction Laue patterns.
LauePt is a robust and extremely easy-to-use Windows application for accurately simulating, indexing and analyzing white-beam X-ray diffraction Laue patterns of any crystals under arbitrary diffraction geometry. This program has a user-friendly graphic interface and can be conveniently used by nonspecialists with little X-ray diffraction or crystallography knowledge. Its wide range of applications include (1) determination of single-crystal orientation with the Laue method, (2) white-beam topography, (3) white-beam microdiffraction, (4) X-ray studies of twinning, domains and heterostructures, (5) verification or determination of crystal structures from white-beam diffraction, and (6) teaching of X-ray crystallography.
ARCS White Beam Vanadium Normalization for SNS Cycle 2021A
This is a white beam data set from V to normalize the relative detector perfromance. See the ARCS_175852.md file for more information
ARCS White Beam Vanadium Normalization for SNS Cycle 2021B
This is a white beam data set from V to normalize the relative detector performance. See the ARCS_201562.md file for more information
ARCS White Beam Vanadium Normalization for SNS Cycle 2020A
This is a white beam data set from V to normalize the relative detector performance. See the ARCS_155050.md file for more information
A new white beam x-ray microdiffraction setup on the BM32 beamline at the European Synchrotron Radiation Facility
A white beam microdiffraction setup has been developed on the bending magnet source BM32 at the European Synchrotron Radiation Facility. The instrument allows routine submicrometer beam diffraction to perform orientation and strain mapping of polycrystalline samples. The setup features large source to optics distances allowing large demagnification ratios and small beam sizes. The optics of the beamline is used for beam conditioning upstream a secondary source, suppressing any possible interference of beam conditioning on beam size and position. The setup has been designed for an easy and efficient operation with position control tools embedded on the sample stage, a high magnification large aperture optical microscope, and fast readout detectors. Switching from the white beam mode to the monochromatic mode is made easy by an automatic procedure and allows the determination of both the deviatoric and hydrostatic strain tensors.
Quantification of grain rotation in bulk nanostructured copper via in situ heating white beam synchrotron X-ray diffraction
Grain rotation during microstructural relaxation under heating is conventionally studied extensively through transmission electron microscopy and simulations. However, there is a shortage in examining grain rotations at larger length and volume scales in bulk materials. It is critical to understand the thermal stability of bulk nanostructured metals, since those enhanced mechanical properties have been well recognized. Here, this study aimed to employ a white beam microdiffraction X-ray technique under in situ heating from 300 K to 1073 K at 12 K/min on a nanostructured copper processed by high-pressure torsion, yielding an initial grain size of ∼260 nm before the heating. Evaluation across a wide range of temperatures reveals transition temperatures associated with microstructural relaxation processes. By tracking separate Laue diffraction peaks stemming from individual grains, changes in their orientations can be estimated and quantified. This approach becomes particularly effective when the number of grains within the probed volume is reasonably small. At temperatures above 940 K, about 7.5 % of Cu grains are rotating at speeds of ∼2 × 10 –3 °/s. The radial direction of the disk specimen is found to be the preferred direction of grain rotation, with the rotation axis along the shear direction. Further analysis found no correlation between peak intensity and peak size, related to grain sizes and deviatoric strain, respectively, with rotation conditions or speed. These findings demonstrate that the diffraction technique utilizing white beam X-rays is a complementary and novel characterization tool for understanding microstructural evolution, especially in grain rotations, of bulk crystalline materials.
High-speed, two-dimensional synchrotron white-beam x-ray radiography of spray breakup and atomization
High-speed, two-dimensional synchrotron x-ray radiography and phase-contrast imaging are demonstrated in propulsion sprays. Measurements are performed at the 7-BM beamline at the Advanced Photon Source user facility at Argonne National Laboratory using a recently developed broadband x-ray white beam. This novel enhancement allows for high speed, high fidelity x-ray imaging for the community at large. Quantitative path-integrated liquid distributions and spatio-temporal dynamics of the sprays were imaged with a LuAG:Ce scintillator optically coupled to a high-speed CMOS camera. Images are collected with a microscope objective at frame rates of 20 kHz and with a macro lens at 120 kHz, achieving spatial resolutions of 12 μm and 65 μm, respectively. Imaging with and without potassium iodide (KI) as a contrast-enhancing agent is compared, and the effects of broadband attenuation and spatial beam characteristics are determined through modeling and experimental calibration. In addition, phase contrast is used to differentiate liquid streams with varying concentrations of KI. The experimental approach is applied to different spray conditions, including quantitative measurements of mass distribution during primary atomization and qualitative visualization of turbulent binary fluid mixing. High-speed, two-dimensional synchrotron white-beam x-ray radiography of spray breakup and atomization. Available from: https://www.researchgate.net/publication/312567827_High-speed_two-dimensional_synchrotron_white-beam_x-ray_radiography_of_spray_breakup_and_atomization [accessed Aug 31, 2017].
ARCS White Beam Vanadium Normalization Data for SNS Cycle 2022B
Neutron scattering Data from a Vanadium cylinder. Acquired on the ARCS spectrometer in white beam mode to normalize the detector efficiencies. During Cycle 2022B
Mapping of Defects in Large-Area Silicon Carbide Wafers via Photoluminescence and its Correlation with Synchrotron White Beam X-Ray Topography
Comparative studies of defect microstructure in 4H-SiC wafers have been carried out using photoluminescence (PL) imaging and grazing-incidence Synchrotron White Beam X-ray Topography. Images of low angle grain boundaries on the PL images correlate well with SWBXT observations, and similar correlation can be established for some micropipe images although the latter is complicated by the overall level of distortion and misorientation associated with the low angle grain boundaries and the fact that many of the micropipes are located in or close to the boundaries. This validation indicates that PL imaging may provide a rapid way of imaging such defect structures in large-scale SiC wafers.
White Beam Normalization
Raw data used to normalize detector performance on the ARCS instrument For the run cycle starting in June 2023. This is a V cylinder and the T0 chopper is set to 150 Hz and phased for 300 meV. All Fermi Choppers are out of the Beam.
Energy dispersive detector for white beam synchrotron x-ray fluorescence imaging
A novel, “single-shot” fluorescence imaging technique has been demonstrated on the B16 beamline at the Diamond Light Source synchrotron using the HEXITEC energy dispersive imaging detector. A custom made furnace with 200µm thick metal alloy samples was positioned in a white X-ray beam with a hole made in the furnace walls to allow the transmitted beam to be imaged with a conventional X-ray imaging camera consisting of a 500 µm thick single crystal LYSO scintillator, mirror and lens coupled to an AVT Manta G125B CCD sensor. The samples were positioned 45° to the incident beam to enable simultaneous transmission and fluorescence imaging. The HEXITEC detector was positioned at 90° to the sample with a 50 µm pinhole 13 cm from the sample and the detector positioned 2.3m from pinhole. The geometric magnification provided a field of view of 1.1×1.1mm{sup 2} with one of the 80×80 pixels imaging an area equivalent to 13µm{sup 2}. Al-Cu alloys doped with Zr, Ag and Mo were imaged in transmission and fluorescence mode. The fluorescence images showed that the dopant metals could be simultaneously imaged with sufficient counts on all 80x80 pixels within 60 s, with the X-ray flux limiting the fluorescence imaging rate. This technique demonstrated that it is possible to simultaneously image and identify multiple elements on a spatial resolution scale ~10µm or higher without the time consuming need to scan monochromatic energies or raster scan a focused beam of X-rays. Moving to high flux beamlines and using an array of detectors could improve the imaging speed of the technique with element specific imaging estimated to be on a 1 s timescale.