Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “wearable sensors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Robustness of topological persistence in knowledge distillation for wearable sensor data

Topological data analysis (TDA) has shown great success in various applications involving wearable sensor data. However, there are difficulties in leveraging topological features in machine learning and wearable sensors because of the large time consumption and computational resources required to extract the features. To address this problem, knowledge distillation (KD) is utilized to generate a small model and accommodate topological features with persistence image (PI) representations from the raw time series data. Deploying topological knowledge in KD enables the student to achieve better performance compared to the one trained solely on raw time series data. However, it is not yet known if there are coherent characteristics for topological features in PI, which can aid in improving the performance during KD. In this paper, we investigate the suitability and challenges of utilizing topological features in KD for wearable sensor data, thereby contributing to the advancement of the field. Our study explores the impact of transferred topological features by comparing the Teacher-to-Student framework with Multiple Teachers-to-Student where teachers utilize both time series data and persistence images obtained by TDA as inputs. Additionally, we conduct a rigorous examination of topological knowledge effects by testing under various corruptions, knowledge types, and learning strategies in the context of human activity recognition tasks. Our analysis of topological features in KD presents the optimal strategy for incorporating these features. This study includes datasets of varying scales, window lengths, and activity classes, providing a comprehensive evaluation. Our results demonstrate that leveraging topological features in KD to enhance performance across databases.

97 MATHEMATICS AND COMPUTING↗

Optimizing Patient-Specific Medication Regimen Policies Using Wearable Sensors in Parkinson’s Disease

Effective treatment of Parkinson’s disease (PD) is a continual challenge for healthcare providers, and providers can benefit from leveraging emerging technologies to supplement traditional clinic care. We develop a data-driven reinforcement learning (RL) framework to optimize PD medication regimens through wearable sensors. We leverage a data set of n = 26 PD patients who wore wrist-mounted movement trackers for two separate six-day periods. Using these data, we first build and validate a simulation model of how individual patients’ movement symptoms respond to medication administration. We then pair this simulation model with an on-policy RL algorithm that recommends optimal medication types, timing, and dosages during the day while incorporating human-in-the-loop considerations on medication administration. The results show that the RL-prescribed medication regimens outperform physicians’ medication regimens, despite physicians having access to the same data as the RL agent. To validate our results, we assess our wearable-based RL medication regimens using n = 399 PD patients from the Parkinson’s Progression Markers Initiative data set. We show that the wearable-based RL medication regimens would lead to significant symptom improvement for these patients, even more so than training RL policies directly from this data set. In doing so, we show that RL models from even small data sets of wearable data can offer novel, generalizable clinical insights and medication strategies, which may outperform those derived from larger data sets without wearable data.

60 APPLIED LIFE SCIENCES↗

The Second Skin: A Wearable Sensor Suite that Enables Real-Time Human Biomechanics Tracking Through Deep Learning

Objective: Real-time determination of human kinematics and kinetics could advance biomechanics research and enable valuable applications of biofeedback and generalizable exoskeleton control. Here, this work aims to investigate a taskindependent, user-independent method for obtaining precise realtime joint state estimation across lower-body joints during a wide variety of tasks. Methods: We developed a generalizable sensing approach using a suit comprised of inertial measurement units (IMUs) and pressure insoles. With the suit, we collected a dataset of 33 tasks commonly performed during construction and hazardous waste cleanup (N = 10). We then trained deep learning user-independent, task-agnostic models to estimate joint lowerbody kinematics and dynamics using only worn sensor data. We likewise computed joint kinematics and dynamics analytically from sensor data to serve as a comparison tool for model results. Results: Our models achieved overall angle estimation root-meansquared-errors (RMSE) of 6.56±.92°, 8.60±1.01°, 7.58±.89°, and 6.00±.73° compared to 13.9±.1.3°, 15.31±1.0°, 10.76±.70°, and 7.56±.48° via analytical methods at the lower back, hip, knee, and ankle, respectively. Likewise, our models achieved overall normalized moment estimation RMSEs of .207±.069 Nm/kg, .242±.044 Nm/kg, .202±.038 Nm/kg, and .193±.034 Nm/kg compared to .306±.036 Nm/kg, .407±.021 Nm/kg, 1.18 ±.022 Nm/kg, and 1.73±.071 Nm/kg via analytical methods at the lower back, hip, knee, and ankle, respectively. Conclusion: These results are comparable to other state-of-the-art wearable sensing systems, establishing deep learning as a viable sensing approach that generalizes to new users and tasks. Significance: This work shows promise for enabling accurate real-world biomechanical data collection and enhancement of biofeedback systems and wearable robot control.

Casey, Ryan T. F. [Georgia Institute of Technology↗

Wearable Sensors Measure Ankle Joint Changes of Patients with Parkinson’s Disease before and after Acute Levodopa Challenge

Background . Previous studies found levodopa could improve the activity of the ankle joints of patients with Parkinson’s disease (PD). But ankle joint movement is composed of four motion ranges. The specific changes of four motion ranges in PD remain unknown. Objective . The purpose of this study was to decompose the complex ankle joint movement, measure ankle joint changes before and after the acute levodopa challenge test (ALCT), and investigate the effects of these parameters on gait performance. Methods . 29 PD patients and 30 healthy control subjects (HC) completed the Instrumented Stand and Walk (ISAW) test and gait parameters were collected by the JiBuEn gait analysis system. The percentage of improvement of gait data and the UPDRS III in the on-drug condition (ON) were determined with respect to the off-drug condition (OFF). Results . We observed a reduction in the heel strike angle (HS), 3-plantarflexion (3-PF) angle, and 4-dorsiflexion (4-DF) angle of ankle joints. We did not find significant difference in the toe-off angle (TO), 1-plantarflexion (1-PF) angle, and 2-dorsiflexion (2-DF) angle among three groups. Stride length improvement rate was significantly correlated with HS ( r s = 0.616, P < 0.001 ) and 3-PF ( r s = 0.639, P < 0.001 ) improvement rates. The improvement in the sum of rigidity items (UPDRS motor subsection item 22) was also correlated with HS ( r s = 0.389, P = 0.037 ) and 3-PF ( r s = 0.373, P = 0.046 ) improvement rates. Conclusions . Exogenous levodopa supplementation can significantly reduce the rigidity of patients with PD, improve their 3-PF and 4-DF of ankle joint kinematic parameters, and ultimately enhance their gait.

Wu, Zhuang↗

The Potential of Wearable Sensor Technology for EVA Glove Ergonomic Evaluation

Injuries to the hands are common among astronauts who train for extravehicular activity (EVA). Many of these injuries refer to the gloves worn during EVA as the root cause. While pressurized, the bladder and outer material of these gloves restrict movement and create pressure points while performing tasks, sometimes resulting in pain, muscle fatigue, abrasions, and occasionally a more severe injury, onycholysis (fingernail delamination). The most common injury causes are glove contact (pressure point/rubbing), ill-fitting gloves, and/or performing EVA tasks in pressurized gloves. A brief review of the Lifetime Surveillance of Astronaut Health's injury database reveals over 57% of the total injuries to the upper extremities during EVA training occurred either to the metacarpophalangeal (MCP) joint, fingernail, or the fingertip. Twenty-five of these injuries resulted in a diagnosis of onycholysis.

Reid, Christopher R.↗

The Potential of Wearable Sensor Technology for EVA Glove Ergonomic Evaluation

Injuries to the hands are common among astronauts who train for extravehicular activity (EVA). Many of these injuries refer to the gloves worn during EVA as the root cause. While pressurized, the bladder and outer material of these gloves restrict movement and create pressure points while performing tasks, sometimes resulting in pain, muscle fatigue, abrasions, and occasionally a more severe injury, onycholysis (fingernail delamination). The most common injury causes are glove contact (pressure point/rubbing), ill-fitting gloves, and/or performing EVA tasks in pressurized gloves. A brief review of the Lifetime Surveillance of Astronaut Health's injury database reveals over 57% of the total injuries to the upper extremities during EVA training occurred either to the metacarpophalangeal (MCP) joint, fingernail, or the fingertip. Twenty-five of these injuries resulted in a diagnosis of onycholysis

Reid, Christopher R.↗

Additively Printed Flexible Temperature Sensor for Wearable Applications

The flexible sensor has the capability to be mounted on any curved surfaces of applications and be used for portable devices. Additively printed sensors have received attention owing to their compact design and ability of application to non-planar surfaces. Wearable applications require capability of integration into a variety of surfaces with ability to flex, fold, twist and stretch under the stresses of daily motion. There is scarcity of data on the interaction of the process parameters with the realized performance. In addition, there is need for data focused on sensor accuracy, repeatability, and reliability. In this study, experimental analysis on function of the fabricated sensing board is conducted. The temperature sensors are made by direct write printing method with nScrypt printer. A calibration of the sensors has been conducted to confirm that resistance is well related to actual temperature and find TCR (temperature coefficient to resistance). The evolution of resistance has been correlated with the environmental temperature. The sensor hysteresis has been quantified using upswing and downswing of the environmental temperature. In addition, the effect of humidity on the temperature sensor accuracy and performance has been quantified. The effect of a polymide coat on the sensor to prevent humidity effects has also been quantified.

Pradeep Lall↗

Let’s Get Real: Are Wearable Plant Sensors Ready for Crop Monitoring?

In recent years, the number of publications describing new and exciting developments in wearable plant sensors (WPSs) has skyrocketed. These small, lightweight sensors hold promise to assist precision agriculture and may thus help reduce crop losses, increase resource use efficiency, and automate crop production. However, WPSs are often not adequately tested in environments relevant for crop growth, and the majority of experimental WPS studies reveal a glaring lack of basic knowledge of plant biology. This review aims to bridge the communication gap between WPS developers and the wider plant research community by (1) providing essential physiological and environmental background information for engineers in relation to WPS sensing capabilities, (2) offering a step-by-step guide to conduct sensor tests on plants correctly, and (3) highlighting potential challenges and suggesting WPS applications in the open field, greenhouses, and vertical farming systems. We hope this review facilitates the development of WPSs and guides them to be truly “ready for the world”.

crop monitoring↗

Hybrid printing of wearable piezoelectric sensors

Piezoelectricity provides an ideal electromechanical mechanism with emerging applications in wearable devices due to its simplicity and self-powered nature. However, the 3D printing of piezoelectric devices still faces many challenges, including material printability, high energy poling process, and low dimensional accuracy. This study demonstrates, for the first time, a tellurium nanowire-based piezoelectric device fabricated by a hybrid printing method integrating highly complementary aerosol jet printing and extrusion printing in a single printing platform. The aerosol-jet-printed tellurium nanowire demonstrates piezoelectric properties without the need for any poling processing due to the unique properties of the tellurium nanowires. The silver nanowire electrodes printed by aerosol jet printing demonstrate excellent conductivity and stretchability without the need for sintering. An extrusion method is employed to print the silicone films, which serve as the stretchable substrate and the electrical insulation layers between the printed tellurium and silver. The printed wearable piezoelectric devices were attached to a human wrist to detect different hand gestures and to a human neck to detect heartbeat without using an external power source. In conclusion, the fully printed, sintering-free and poling-free, and stretchable piezoelectric device opens enormous opportunities for facile integration with a broad range of printed electronics and wearable devices.

47 OTHER INSTRUMENTATION↗

Single-atom materials boosting wearable orthogonal uric acid detection

Abstract Uric acid (UA) is a vital biomarker for the diagnosis and management of various health conditions, including cardiovascular diseases, gout, kidney disorders, metabolic syndrome, and wound healing. Despite significant advances in wearable sensor technology, challenges persist in developing wearable sensors that are capable of maintaining high sensitivity, selectivity, and stability. In this study, we present an epidermal sensing platform enhanced with single-atom materials (SAMs) designed for flexible and orthogonal electrochemical detection of UA. We designed and synthesized an SAM with Fe-N 5 active sites to boost the electrochemical sensing signals, integrating it with laser-engraved graphene (LEG) to fabricate a wearable SAM-based UA patch sensor. This design provides superior UA detection performance compared to sensors based on conventional nanomaterials. In addition, we enhanced the detection accuracy and range by using an orthogonal approach that combines direct oxidation through differential pulse voltammetry (DPV) along with parallel biocatalytic amperometric detection. The resulting SAM-based UA orthogonal sensor patch demonstrated exceptional performance in wearable applications through tests measuring sweat UA levels in subjects before and after consuming a purine-rich diet. Graphical Abstract

Ding, Shichao↗

Functional Data Analysis in Wearable Body Sensor Networks

Improving response time of indirect room-size calorimeters is still an outstanding problem in metabolic research. Accurate estimates of instantaneous rates of gaseous exchange require numerical differentiation of measured gaseousgas concentrations. We propose a new method to estimate the instantaneous gaseousgas exchange rates in indirect calorimetry. In contrast to the previously developed techniques, the method addresses the problem of differentiation of gaseous concentrations as an ill-posed problem. By applying the method of regularization, the problem of differentiation is converted into a well-posed problem resulting in smooth and consistent gaseous exchange rates. The validity of the method is tested on a large dataset of calorimeter experiments which included 313 human experiments along with 231 alcohol combustion experiments. It is demonstrated that the method is able to reliably differentiate between the “unphysiological” process of alcohol combustion and physiological variations produced by human metabolism. The method also allowed unraveling the previously unreported relative kinetics of O2 consumption and Respiratory Quotient (RQ) in humans. It was found that the kinetics of oxidative fuel selection lags behind the energy expenditure in humans exhibiting some sort of oxidative inertia. The time lag varies from 2-3 min up to 30 min, depending on particular individual. No such lag was found in alcohol combustion experiments. In addition to the relative kinetics of substrate oxidation, two statistical indexes reflecting variability of minute-by-minute RQ were estimated. The indexes were the RQ’s standard deviation and RQ’s first-order derivative. Both indexes showed statistically significant difference between human experiments and alcohol combustion experiments. We conclude that the proposed method can consistently extract physiologically-relevant information from noisy calorimetry data and the aforesaid information can provide additional insights into the mechanism of metabolic fuel selection in humans.

54 ENVIRONMENTAL SCIENCES↗

Functional Data Analysis in Wearable Body Sensor Networks

Improving response time of indirect room-size calorimeters is still an outstanding problem in metabolic research. Accurate estimates of instantaneous rates of gaseous exchange require numerical differentiation of measured gaseousgas concentrations. We propose a new method to estimate the instantaneous gaseousgas exchange rates in indirect calorimetry. In contrast to the previously developed techniques, the method addresses the problem of differentiation of gaseous concentrations as an ill-posed problem. By applying the method of regularization, the problem of differentiation is converted into a well-posed problem resulting in smooth and consistent gaseous exchange rates. The validity of the method is tested on a large dataset of calorimeter experiments which included 313 human experiments along with 231 alcohol combustion experiments. It is demonstrated that the method is able to reliably differentiate between the “unphysiological” process of alcohol combustion and physiological variations produced by human metabolism. The method also allowed unraveling the previously unreported relative kinetics of O2 consumption and Respiratory Quotient (RQ) in humans. It was found that the kinetics of oxidative fuel selection lags behind the energy expenditure in humans exhibiting some sort of oxidative inertia. The time lag varies from 2-3 min up to 30 min, depending on particular individual. No such lag was found in alcohol combustion experiments. In addition to the relative kinetics of substrate oxidation, two statistical indexes reflecting variability of minute-by-minute RQ were estimated. The indexes were the RQ’s standard deviation and RQ’s first-order derivative. Both indexes showed statistically significant difference between human experiments and alcohol combustion experiments. We conclude that the proposed method can consistently extract physiologically-relevant information from noisy calorimetry data and the aforesaid information can provide additional insights into the mechanism of metabolic fuel selection in humans.

60 - APPLIED LIFE SCIENCES↗

Lunar Health Monitor (LHM)

Orbital Research, Inc., has developed a low-profile, wearable sensor suite for monitoring astronaut health in both intravehicular and extravehicular activities. The Lunar Health Monitor measures respiration, body temperature, electrocardiogram (EKG) heart rate, and other cardiac functions. Orbital Research's dry recording electrode is central to the innovation and can be incorporated into garments, eliminating the need for conductive pastes, adhesives, or gels. The patented dry recording electrode has been approved by the U.S. Food and Drug Administration. The LHM is easily worn under flight gear or with civilian clothing, making the system completely versatile for applications where continuous physiological monitoring is needed. During Phase II, Orbital Research developed a second-generation LHM that allows sensor customization for specific monitoring applications and anatomical constraints. Evaluations included graded exercise tests, lunar mission task simulations, functional battery tests, and resting measures. The LHM represents the successful integration of sensors into a wearable platform to capture long-duration and ambulatory physiological markers.

Lisy, Frederick J.↗

Multifunctional Silk Fibroin Hydrogels with Strong Adhesion for Tissue Sealing and Wearable Electronic Sensors

Multifunctional hydrogels with excellent adhesion, biodegradability, and conductivity are essential for overcoming the obstacles of postoperative secondary injury, flexible sensing instability, and so on. Herein, we develop a multifunctional silk fibroin (SF) hydrogel modified with poly(acrylic acid). Owing to the stable chemical cross-linking network and the abundant carboxylic acid groups of the SF network, the SF hydrogel exhibits a high tensile strength of 74.34 kPa due to sufficient cohesion and interfacial interactions. Additionally, the tensile strain reaches a maximum of 414.6%, the compressive strength is 0.9 MPa, and the shear adhesive strength for pig skin tissues is as high as 64 kPa. Compared with most hydrogels, our multifunctional SF hydrogel with a low swelling ratio provides excellent adhesion, biodegradation, and conductivity, which shows advantages in terms of invasive tissue sealing. Furthermore, the use of self-adhesive SF hydrogels as conductive hydrogels in flexible sensors also benefits the collection of physiological electricity and human motion signals in the field of wearable and implantable electronic devices.

adhesive↗

Graphene K‐Tape Meshes for Densely Distributed Human Motion Monitoring

Abstract Wearable sensors that measure parameters associated with physical activity and bodily motions have been regarded as an indispensable tool for assessing personal wellness. Recent advances in nanocomposite strain sensors have been successfully used for monitoring skin strains and other strain‐derived physiological parameters. This study complements the existing body of work and presents a flexible, self‐adhering, fabric‐based wearable sensor for measuring skin strains and human motions. Graphene nanosheet thin films are directly spray‐coated onto kinesiology tape (K‐Tape) to obtain a self‐adhering strain sensor of high sensitivity and linearity. Their stable sensing performance and high repeatability are verified, while human subject tests confirm that they adequately capture muscle engagement during functional movements. In addition, densely distributed strain monitoring can be achieved using an electrical impedance tomography measurement approach and algorithm. Spatial strain sensing is successfully demonstrated using a single strip of piezoresistive K‐Tape, as well as when a K‐Tape network or mesh pattern is formed. The results show promise for using graphene K‐Tape meshes to measure how specific major muscle groups engage during different physical activities.

Lin, Yun‐An↗

Freestanding BaTiO 3 ‐Au Vertically Aligned Nanocomposite toward Flexible Multi‐Sensing Platform

Abstract Flexible and wearable sensors show enormous potential for personalized healthcare devices by real‐time monitoring of an individual's health. Typically, a single functional material is selected for one sensor to sense a particular physical signal while multiple materials will be selected for multi‐mode sensing. Vertically aligned nanocomposites (VANs) have recently demonstrated various material combinations and novel coupled multifunctionalities that are hard to achieve in any single‐phase material alone, including multiphase multiferroics, magneto‐optic coupling, and strong magnetic and optical anisotropy. Integrating these novel VANs into wearable sensors shows enormous potential in multi‐mode sensing owing to their multifunctional nature. In this work, the transfer of VANs onto polydimethylsiloxane as a novel flexible chemical and pressure sensor is demonstrated. For this demonstration, the classical BaTiO 3 ‐Au VAN with combined plasmonic and piezoelectric properties is used to demonstrate a multi‐sensing mechanism. A thin water‐soluble buffer of Sr 3 Al 2 O 6 serves as a buffer layer for the epitaxial growth and transfer process. The electrical output based on the piezoelectric responses and identifying 4‐mercaptobenzoic acid by surface‐enhanced Raman spectroscopy reveal great potential for free‐standing VANs in a wearable multifunctional sensing platform.

Tsai, Benson Kunhung [School of Materials Engineer↗

Optimizing Individualized Treatment Planning for Parkinson’s Disease Using Deep Reinforcement Learning

More than one million people currently live with Parkinson's Disease (PD) in the U.S. alone. Medications, such as levodopa, can help manage PD symptoms. However, medication treatment planning is generally based on patient history and limited interaction between physicians and patients during office visits. This limits the extent of benefit that may be derived from the treatment as disease/patient characteristics are generally non-stationary. Wearable sensors that provide continuous monitoring of various symptoms, such as bradykinesia and dyskinesia, can enhance symptom management. However, using such data to overhaul the current static medication treatment planning approach and prescribe personalized medication timing and dosage that accounts for patient/care-giver/physician feedback/preferences remains an open question. We develop a model to prescribe timing and dosage of medications, given the motor fluctuation data collected using wearable sensors in real-time. We solve the resulting model using deep reinforcement learning (DRL). The prescribed policy determines the optimal treatment plan that minimizes patient's symptoms. Our results show that the model-prescribed policy outperforms the static a priori treatment plan in improving patients' symptoms, providing a proof-of-concept that DRL can augment medical decision making for treatment planning of chronic disease patients.

Watts, Jeremy↗

Flexible Vanadium Dioxide Photodetectors for Visible to Longwave Infrared Detection at Room Temperature

Abstract Flexible optoelectronics is a rapidly growing field, with a wide range of potential applications. From wearable sensors to bendable solar cells, curved displays, and curved focal plane arrays, the possibilities are endless. The criticality of flexible photodetectors for many of these applications is acknowledged, however, devices that are demonstrated thus far are limited in their spectral range. In this study, flexible photodetectors are demonstrated using a VO x nanoparticle ink, with an extremely broad operating wavelength range of 0.4 to 20 µm. This ink is synthesized using a simple and scalable wet‐chemical process. These photodetectors operate at room temperature and exhibit minimal variance in performance even when bent at angles of up to 100 ° at a bend radius of 6.4 mm. In addition, rigorous strain testing of 100 bend and release cycles revealed a photoresponse with a standard deviation of only 0.55%. This combination of mechanical flexibility, wide spectral response, and ease of fabrication makes these devices highly desirable for a wide range of applications, including low‐cost wearable sensors and hyperspectral imaging systems.

36 MATERIALS SCIENCE↗