Engineering PapersSearch

SEARCH · Engineering Papers

Results for “water vapor pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Distributions of eight meteorological variables at Cape Kennedy, Florida and Vandenberg Air Force Base, California

Extreme values, median values, and nine percentile values are tabulated for eight meteorological variables at Cape Kennedy, Florida and at Vandenberg Air Force Base, California. The variables are temperature, relative humidity, station pressure, water vapor pressure, water vapor mixing ratio, density, and enthalpy. For each month eight hours are tabulated, namely, 0100, 0400, 0700, 1000, 1300, 1600, 1900, and 2200 local time. These statistics are intended for general use for the space shuttle design trade-off analysis and are not to be used for specific design values.

Graves, M. E.

Water-vapor pressure control in a volume

The variation with time of the partial pressure of water in a volume that has openings to the outside environment and includes vapor sources was evaluated as a function of the purging flow and its vapor content. Experimental tests to estimate the diffusion of ambient humidity through openings and to validate calculated results were included. The purging flows required to produce and maintain a certain humidity in shipping containers, storage rooms, and clean rooms can be estimated with the relationship developed here. These purging flows are necessary to prevent the contamination, degradation, and other effects of water vapor on the systems inside these volumes.

Scialdone, J. J.

Effects of Water Vapor on the Reactivity of Aluminosilicates in Vapor-Phase Propanal Aldol Condensation

Aluminosilicate materials have been extensively studied as efficient aldol catalysts for C-C coupling reactions due to their acidic nature, high surface area, thermal stability, and porous structure. This work investigated the impact of water vapor pressure on the catalytic reactivity of aluminosilicates for the aldol condensation of propanal to 2-methyl-2-pentenal (MP). The catalytic performance of amorphous SiO2-Al2O3 (A-Si-Al) and aluminated MCM-41 (Al-MCM-41) for the vapor-phase aldol condensation of propanal was evaluated at 200 degrees C as a function of vapor-phase water content at atmospheric pressure. Our findings demonstrate that co-feeding low water vapor pressures (1-18 kPa) with propanal enhances the rates of MP production at 200 degrees C on A-Si-Al. Conversely, water vapor pressures of 25 kPa result in a decrease in aldol dimer formation rates. The rate of MP production evaluated on Al-MCM-41 also increased in the presence of 5 kPa water compared to anhydrous conditions. Propylamine temperature-programmed desorption analyses revealed an increase in Bronsted acid site density when both catalysts were exposed to water, which likely accounts for the observed enhancement in aldol condensation reactivity under hydrous conditions. Reversibility testing of the water vapor effect under reaction conditions, combined with X-ray diffraction analysis of fresh, spent, and regenerated catalysts, revealed no structural changes in either aluminosilicate upon exposure to water or reaction conditions. The rates of aldol condensation and the impact of water vapor were highly consistent across both materials, suggesting that zeolite crystallinity has minimal influence on the catalytic performance.

acid catalysts

Evaluation of Mechanical and Thermomechanical Water Vapor Compression Techniques for Enabling High Temperature Lift Hydration-Based Chemical Heat Pumps

Achieving high temperature lifts (>200 K) via a chemical heat pump based on salt hydration/dehydration reactions requires the transport of water vapor from low to high pressure. Alternative compression approaches require condensing of low-pressure water vapor, pumping of liquid water, and subsequent evaporation when the low-side pressure corresponds to sub-ambient water saturation temperatures. Thus, this study compares four steam compression methods for use within a chemical heat pump system based on a reversible calcium oxide hydration/dehydration reaction with a temperature lift from 350 °C heat to >600 °C. Purely mechanical and thermochemical/mechanical compression technologies are considered. A parametric study of maximum allowable temperature, the isentropic efficiency of mechanical compressors, the effectiveness of heat exchangers, and the assumed allowable heat exchanger pressure drop is conducted to determine the mechanical and thermal energy consumed per kilogram of compressed steam. The system complexity in terms of the number of main system components, maximum pressure ratio, and maximum allowable temperature is estimated. Model results show an absorption-based steam compressor has the highest exergetic efficiency for the required chemical heat pump required conditions. As a result, this system configuration was then experimentally demonstrated to illustrate the impact of system performance on component effectiveness.

Advanced reactors

Respiratory weight losses during exercise.

Evaporative water loss from the respiratory tract was determined over a wide range of exercise. The absolute humidity of the expired air was the same at all levels of exercise and equal to that measured at rest. The rate of respiratory water loss during exercise was found to be 0.019 of the oxygen uptake times (44 minus water vapor pressure). The rate of weight loss during exercise due to CO2-O2 exchange was calculated. For exercise at oxygen consumption rates exceeding 1.5 L/min in a dry environment with a water vapor pressure of 10 mm Hg, the total rate of weight loss via the respiratory tract is on the order of 2-5 g/min.

Mitchell, J. W.

The prediction of zenith range refraction from surface measurements of meteorological parameters

In the last two decades, increasingly sophisticated deep space missions have placed correspondingly stringent requirements on navigational accuracy. As part of the effort to increase navigational accuracy, and hence the quality of radiometric data, much effort has been expended in an attempt to understand and compute the tropospheric effect on range (and hence range rate) data. The general approach adopted has been that of computing a zenith range refraction, and then mapping this refraction to any arbitrary elevation angle via an empirically derived function of elevation. The prediction of zenith range refraction derived from surface measurements of meteorological parameters is presented. Refractivity is separated into wet (water vapor pressure) and dry (atmospheric pressure) components. The integration of dry refractivity is shown to be exact. Attempts to integrate wet refractivity directly prove ineffective; however, several empirical models developed by the author and other researchers at JPL are discussed. The best current wet refraction model is here considered to be a separate day/night model, which is proportional to surface water vapor pressure and inversely proportional to surface temperature. Methods are suggested that might improve the accuracy of the wet range refraction model.

Berman, A. L.

Measurement of transpiration in Pinus taeda L. and Liquidambar styraciflua L. in an environmental chamber using tritiated water

Transpiration rates of loblolly pine (Pinus taeda L.) and sweetgum (Liquidambar styraciflua L.) were measured at two different atmospheric water vapor pressure deficits (V.P.D.) in a controlled environment growth chamber using tritiated water as a tracer. The trees were maintained in a sealed plant bed containing a hydroponic nutrient solution into which labeled water (spike) was introduced. Samples of leaves, chamber air, spiked nutrient solution and control water were assayed for ratio-activity using liquid scintillation techniques to determine transpiration rates. The transpiration rate of sweetgum in ml./hr./gm. (4.95) was found to be 5 times greater than that of loblolly pine (1.03) at 1.84 V.P.D. and 8 times greater at 6.74 V.P.D. (15.99 for sweetgum vs. 2.19 for pine). Transpiration (based on measurements of leaf radioactivity) in both species rose with increasing deficit; however sweetgum increased its output by 3 times while pine only doubled its rate. Cyclical changes in transpiration rates were noted in both species; the sweetgum cycle required a 6 hour interval whereas the pine cycle required a 9 hour interval.

Levy, G. F.

Phase Transformation and Water Adsorption Behavior of As‐Deposited and Annealed Ru Metal Thin Films Prepared by Atomic Layer Deposition

ABSTRACT Surfaces play a central role in catalytic processes, and understanding the transformation of ruthenium metal into ruthenium oxide during annealing is essential for tailoring functional catalytic interfaces. In this study, we systematically investigate ≈22 nm thick Ru metal films deposited by atomic layer deposition (ALD) at 300°C, focusing on their chemical composition, structural evolution, and surface hydration behavior following post‐deposition annealing in air from 400 to 600°C. Lab‐based and synchrotron X‐ray photoelectron spectroscopy (XPS) reveal a gradual conversion from metallic Ru to fully oxidized Ru 4+ with increasing annealing temperature, accompanied by a corresponding increase in lattice oxygen. X‐ray diffraction (XRD) shows amorphous Ru oxide phases at 400°C and 500°C that evolve into crystalline RuO 2 at 600°C, while atomic force microscopy (AFM) indicates enhanced grain growth and surface roughening upon annealing. Ambient‐pressure XPS (AP‐XPS) under controlled H 2 O vapor environments (1–17 Torr) demonstrates that samples annealed at 400°C and 500°C exhibit initially high hydroxyl coverage that decreases with increasing water vapor pressure, concurrent with a rise in molecular H 2 O adsorption. In contrast, the crystalline RuO 2 surface formed at 600°C maintains stable hydroxylation and supports increased water uptake. Overall, this work provides fundamental insight into Ru oxide–H 2 O interactions and establishes design principles for engineering oxide surfaces optimized for electrocatalytic applications.

APXPS

The solubility of NdPO 4 and DyPO 4 and stability of Nd and Dy chloride and hydroxyl complexes as a function of pH and salinity to 450 °C

The mobility of rare earth elements (REE) in geological systems is often controlled by the stability of monazite and xenotime, which are important hosts for the light and heavy REE. These REE phosphates constitute important resources and provide information on ore formation conditions and timing due to their uses as geothermometers and geochronometers. While the thermodynamic properties for these minerals are well-established up to high temperature and pressure, the properties for the aqueous REE complexes are not well constrained with limited information up to 300 °C. In this study, the solubility of synthetic NdPO 4 and DyPO 4 endmembers were measured in hydrothermal sub- to supercritical NaCl-bearing aqueous solutions from 350 at saturated water vapor pressure to 450 °C at 700 bar. The speciation of Nd and Dy was determined in acidic to alkaline solutions (pH 25 °C values from 2 to 10), and indicates that the hydroxyl species REE(OH) 2 + and REE(OH) 3 0 predominate at low salinity (0.01 mol/kg NaCl) with some contribution of REE chloride species REECl 2+ and REECl 2 + in acidic fluids. The REE phosphate solubility measured in these experiments is up to two orders of magnitude higher than predicted using existing thermodynamic properties from literature for aqueous species extrapolated from lower temperature data to supercritical conditions. To address this discrepancy, the thermodynamic properties of the REE aqueous species were optimized using GEMSFITS to derive the formation constants for the REE chloride (β Cl ) and hydroxyl (β OH ) complexes in the studied temperature range. This study highlights the importance of the hydroxyl species REE(OH) 2 + and REE(OH) 3 0 over a wide range of pH and temperature. As a result, the revised thermodynamic properties for Dy and Nd chloride and hydroxyl species more accurately predict the solubility of NdPO 4 and DyPO 4 and provide insight into the speciation and mobility of the light and heavy REE in hydrothermal supercritical fluids in the crust.

58 GEOSCIENCES

Hydrothermal solubility of Dy hydroxide as a function of pH and stability of Dy hydroxyl aqueous complexes from 25 to 250 °C

The rare earth elements (REE) have important applications in green energy technologies. The formation of mineral deposits in geologic systems commonly involves hydrothermal fluids which can mobilize the REE. However, the REE speciation is not well known as a function of pH. The thermodynamic properties of REE hydroxyl complexes used in geochemical models are based on the Helgeson-Kirkham-Flowers (HKF) equation of state parameters which were derived by extrapolation of low temperature experimental and estimated data. In this study, Dy hydroxide solubility experiments are combined with available literature data to improve these models from 25 to 250 °C and optimize the thermodynamic properties of Dy 3+ and Dy hydroxyl complexes using GEMSFITS. Batch-type solubility experiments were conducted from 150 to 250 °C and at saturated water vapor pressure in perchloric acid solutions with initial pH values of 2 to 5 in 0.5 pH unit increments. The measured solubility of Dy hydroxide is retrograde with temperature and decreases with pH. The logarithm of total dissolved Dy molality ranges from –2.3 to –5.3 at 150 °C (pH 4.7–5.5), from –2.4 to –5.6 at 200 °C (pH 3.9–5.1), and from –3.7 to –6.9 at 250 °C (pH of 3.4 and 5.0). The optimized standard partial molal Gibbs energies of formation (Δ f G° T ) derived for Dy 3+ and DyOH 2+ display a close to linear relationship with temperature, fitting with previous optimizations based on DyPO 4 solubility data in the literature. A comparison of the optimized ΔfG°T values for aqueous Dy species with predictions from available HKF parameters indicates significant differences ranging from +11 to –26 kJ/mol between 25 and 250 °C. The experimental fits are used to derive the Dy hydroxide solubility products (K s0 ) and formation constants for the hydrolysis of Dy (β n with n = 1 to 3; Dy 3+ + nOH – = DyOH n 3-n ) as a function of temperature. The optimization method presented yields accurate thermodynamic properties for the Dy 3+ aqua ions and the DyOH 2+ species at the acidic to mildly acidic pH studied whereas more experimental work is needed at near-neutral and alkaline conditions to better constrain the other hydroxyl complexes. Furthermore, the optimized thermodynamic data have a significant impact on geochemical modeling of the mobility and solubility of REE minerals in acidic hydrothermal fluids.

58 GEOSCIENCES

Selective transport of light vs. heavy rare earth elements by sulfate/bisulfate complexes in hydrothermal fluids

Here, this study explores the transport of rare earth elements (REE) in acidic sulfate-bearing hydrothermal fluids and the implications for the fractionation of light/heavy REE in critical mineral deposits. The speciation of Nd (light REE) and Yb (heavy REE) sulfate complexes were determined via in situ Raman spectroscopy using fused SiO 2 capillary cells up to 300 ºC at saturated water vapor pressure and in a hydrothermal diamond anvil cell up to 500 ºC and 540 MPa. The REE monosulfate (REESO 4 + ) and REE disulfate (REE(SO 4 ) 2 - ) species are stable below 150 to 250 ºC but become less stable at higher temperatures, particularly the light REE, due to the decreased solubility of REE sulfate solids. At higher pressure, these REE sulfate complexes display an increased stability field up to 400 ℃. The REE bisulfate complex (REEHSO 4 2+ ) was identified with a wide stability field below 400 ºC for the HREE in acidic Yb 2 (SO 4 ) 3 -bearing solutions, whereas in Nd 2 (SO 4 ) 3 -bearing solutions, the LREE bisulfate complex is restricted to below 100 ℃. These results suggest that bisulfate is a previously unrecognized selective ligand for heavy REE transport at low temperature in acidic oxidized hydrothermal fluids. Such fluids are responsible for hydrothermal alteration in many REE deposits. Prediction of phase stabilities across pressure, temperature, and composition space (P-T- x ) is crucial for predicting the role of aqueous REE sulfate complexes in the mobilization of REE in crustal fluids.

58 GEOSCIENCES

Chemical-specific Parameters Dataset

The chemical-specific parameters dataset is searchable for physicochemical information for multiple chemicals simultaneously. After selecting chemicals of interest and the desired parameters, the RAIS will generate a table containing the values, chosen according to an established hierarchy. Results can be downloaded in Excel format. Over 40 parameters are available, including melting point, boiling point, density, density, vapor pressure, water solubility, and Henry’s Law constants. Thirteen primary sources are used to populate the dataset of chemical-specific parameters. These values should be used in cancer risk and noncancer hazard assessments for the calculation of preliminary remediation goals (PRGs), hazard characterization, and transport modeling. Users can select up to 1000 chemicals per query. The dataset supports environmental risk assessments, regulatory decision-making, and environmental planning with tools for benchmarking against risk-based standards. This structured approach ensures a robust evaluation of environmental risks tailored to regulatory needs.

Dolislager, Fred [Oak Ridge National Laboratory (O

Infrared thermal mapping experiment - The Viking Mars Orbiter.

The Mars infrared thermal mapper (IRTM) will be carried on the scan platform of the orbiter of the Viking 1975 mission. The IRTM is a multichannel radiometer with several detectors in each of six spectral regions. The spectral channels are selected to be sensitive to surface emissivity variations and provide good temperature resolution over the entire range of Martian temperatures. These observations will allow determination of the surface kinetic temperature and thermal balance, and by coverage of the dark hemisphere, a search for regions with anomalous cooling can be made. Observations of ground frosts or clouds will help to determine their composition, and in the case of extensive H2O frosts, will allow the local water vapor pressure to be estimated.

Kieffer, H. H.