Engineering PapersSearch

SEARCH · Engineering Papers

Results for “water temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A wave tank study of the dependence of X band cross sections on wind speed and water temperature

The effects of varying the water temperature, wind speed, and wind stress on the values of backscatter were investigated using measurements of normalized radar cross sections of wind-generated waves, made at X band for both vertical and horizontal polarization for incidence angles 10, 28, 48, and 68 deg. The experiment was conducted using the Naval Research Laboratory wind-wave tank. Measurements made for a wide range of wind speeds and water temperatures are compared with results of backscattering models currently in use.

Keller, Mary Ruth

Remote sensing of subsurface water temperature by Raman scattering

The application of Raman scattering to remote sensing of subsurface water temperature and salinity is considered, and both theoretical and experimental aspects of the technique are discussed. Recent experimental field measurements obtained in coastal waters and on a trans-Atlantic/Mediterranean research cruise are correlated with theoretical expectations. It is concluded that the Raman technique for remote sensing of subsurface water temperature has been brought from theoretical and laboratory stages to the point where practical utilization can now be developed.

Leonard, D. A.

The effect of water temperature and synoptic winds on the development of surface flows over narrow, elongated water bodies

Simulations of the thermally induced breeze involved with a relatively narrow, elongated water body is presented in conjunction with evaluations of sensible heat fluxes in a stable marine atmospheric surface layer. The effect of the water surface temperature and of the large-scale synoptic winds on the development of surface flows over the water is examined. As implied by the sensible heat flux patterns, the simulation results reveal the following trends: (1) when the synoptic flow is absent or light, the induced surface breeze is not affected noticeably by a reduction of the water surface temperature; and (2) for stronger synoptic flow, the resultant surface flow may be significantly affected by the water surface temperature.

Segal, M.

Remote sensing of subsurface water temperature by laser Raman spectroscopy

This paper describes experimental remote sensing of subsurface water temperature using the Raman spectroscopic technique. By the use of a pulsed laser and range gating detection techniques, Raman scattering is analyzed as a function of depth in a radar-like echo mode, and thus subsurface profiles of temperature and transmission are obtained. Experiments are described in which Raman data using polarization spectroscopy has been obtained from a ship as a function of depth in ocean water near Grand Bahama Island. A spectral temperature accuracy of + or - 1 C has been obtained from this data in the first two optical attenuation lengths. Raman data obtained from ocean water using the NASA airborne oceanographic lidar is also presented.

Leonard, D. A.

An algorithm for the estimation of water temperatures from thermal multispectral airborne remotely sensed data

A method for water temperature estimation on the basis of thermal data is presented and tested against NASA's Thermal IR Multispectral Scanner. Using realistic bounds on emissivities, temperature bounds are calculated and refined to estimate a tighter bound on the emissivity of the source. The method is useful only when a realistic set of bounds can be obtained for the emissivities of the data.

Jaggi, S.

Effect of water temperature on diuresis-natriuresis: AVP, ANP, and urodilatin during immersion in men

Effects of water temperature on diuresis, natriuresis, and associated endocrine responses during head-out immersion were studied in eight men during four 5-h experimental conditions: air control at 28 C and immersion at 34.5 C (thermoneutral (Tnt)), 36 C (above Tnt (aTnt)), and 32 C (below Tnt (bTnt). Esophageal temperature decreased by approximately 0.4 C in bTnt and increased by approximately 0.5 C in aTnt. Cardiac output increased by approximately 80% in aTnt and approximately 40% in bTnt while thoracic impedance, an index of central blood pooling, decreased by 7.5 ohms in bTnt (NS vs. Tnt) and 8.8 ohms in aTnt. Total peripheral resistance decreased at all temperatures (50% in aTnt, 20% in bTnt). Urine flow and Na(+) excretion increased by sixfold in bTnt and Tnt but by only threefold in aTnt. Creatinine clearance was unchanged while osmolal clearance (but not free water clearance) increased two-fold with all immersions. Plasma atrial natriuretic peptide (ANP), urinary urodilatin, and urinary guanosine 3',5'-cyclic monophosphate increased while plasma renin activity, aldosterone, and arginine vasopressin (AVP) decreased similarly at all temperatures. bTnt did not potentiate diuresis by selective attenuation of AVP. The overall natriuretic response exhibited a higher correlation with urodilatin than with ANP. Because diuresis and natriuresis were significantly attenuated in aTnt where central blood pooling was greater, we conclude that mechanisms other than the atrial stretch receptor reflex, i.e., urodilatin and effective arterial blood volume, may play more predominant roles in the mechanism of immersion-induced diuresis and natriuresis.

Nakamitsu, S.

Corrosion reduction of aluminum alloys in flowing high-temperature water

Report describes a technique for reducing the corrosion rate of aluminum by adding colloidal substances in a closed-loop system. Experimental work shows that the addition of graphite and colloidal hydrated aluminum oxide significantly reduces the corrosion rate in flowing high-temperature water.

Draley, J. E.

Experimental and predicted cavitation performance of an 80.6 deg helical inducer in high temperature water

The cavitating performance of a stainless steel 80.6 degree flat-plate helical inducer was investigated in water over a range of liquid temperatures and flow coefficients. A semi-empirical prediction method was used to compare predicted values of required net positive suction head in water with experimental values obtained in water. Good agreement was obtained between predicted and experimental data in water. The required net positive suction head in water decreased with increasing temperature and increased with flow coefficient, similar to that observed for a like inducer in liquid hydrogen.

Kovich, G.

Method of measuring sea surface water temperature with a satellite including wideband passive synthetic-aperture multichannel receiver

A wideband passive synthetic-aperture multichannel receiver with an antenna is mounted on a satellite which travels in an orbit above the Earth passing over large bodies of water, e.g., the Atlantic Ocean. The antenna is scanned to receive signals over a wide frequency band from each incremental surface area (pixel) of the water which are related to the pixel's sea temperature. The received signals are fed to several channels which are tuned to separate selected frequencies. Their outputs are fed to a processor with a memory for storage. As the antenna points to pixels within a calibration area around a buoy of known coordinates, signals are likewise received and stored. Exactly measured sea temperature is received from the buoy. After passing over several calibration areas, a forward stepwise regression analysis is performed to produce an expression which selects the significant from the insignificant channels and assigns weights (coefficients) to them. The expression is used to determine the sea temperature at each pixel based on the signals received therefrom. Wind temperature, pressure, and wind speed at each pixel can also be calculated.

Stacey, J. M.

The spatial variability of coastal surface water temperature during upwelling

Thermal scanner imagery acquired during a field experiment designed to study an upwelling event in Lake Superior is investigated. Temperature data were measured by the thermal scanner, with a spatial resolution of 7 m. These data were correlated with temperatures measured from boats. One- and two-dimensional Fourier transforms of the data were calculated and temperature variances as a function of wavenumber were plotted. A k-to-the-minus-three dependence of the temperature variance on wavenumber was found in the wavenumber range of 1-25/km. At wavenumbers greater than 25/km, a k-to-the-minus-five-thirds dependence was found.

Scarpace, F. L.

Experimental remote sensing of subsurface temperature in natural ocean water

The first successful depth-resolved remote sensing measurements of subsurface ocean water temperature were obtained by spectral analysis of the 3400 per cm O-H stretching Raman band of liquid water. Raman spectral data were obtained from a research vessel at various depths from the surface to 10 meters below the surface in a tidal estuary. The temperature inferred from the spectra was consistent with ground truth temperature to within the shot noise limited accuracy of plus or minus 2 C. The performance of a future fully developed airborne laser Raman water temperature measurement system is estimated on the basis of these first tests.

Leonard, D. A.

Efficacy of Wrist/Palm Warming as an EVA Countermeasure to Maintain Finger Comfort in Cold Conditions During EVA

This study explored the effectiveness of local wrist/palm warming as a potential countermeasure for providing finger comfort during extended duration EVA. Methods: Six subjects (5 males and 1 female) were evaluated in a sagitally divided liquid cooling/warming garment (LCWG) with modified liquid cooling/warming (LCW) gloves in three different experimental conditions. Condition 1: Stage 1- no LCWG; chamber adaptation with LCW glove inlet water temperature 33 C; Stage 2-LCW glove inlet water temperature cooled to 8 C; Stage 3-LCW glove inlet water temperature warmed to 45 C; Condition 2: Stage1-LCWG and LCW glove inlet water temperature 33 C; Stage 2-LCWG inlet temperature cooled to 31 C, LCW gloves, 8 C; Stage 3-LCWG inlet water temperature remains at 31 C, LCW glove inlet water temperature warmed to 45 C; Condition 3: Stage l -LCWG and LCW gloves 33 C; Stage 2-LCWG inlet water temperature cooled to 28 C, LCW gloves, 8 C; Stage 3-LCWG remains at 28 C, LCW glove water temperature warmed to 45 C. Results: Wrist/palm area warming significantly increased finger temperature (Tfing) and blood perfusion in Stage 3 compared to Stage 2. The LCW gloves were most effective in increasing Stage 3 Tfing in Condition 1; and in increasing blood perfusion in Conditions 1 and 2 compared to Condition 3. Ratings of subjective perception of heat in the hand and overall body heat were higher at Stage 3 than Stage 2, with no significant differences across Conditions. Conclusions: Local wrist/palm warming was effective in increasing blood circulation to the distal extremities, suggesting the potential usefulness of this technique for increasing astronaut thermal comfort during EVA while decreasing power requirements. The LCW gloves were effective in heating the highly cooled fingers when the overall body was in a mild heat deficit.

Koscheyev, Victor S.

The effect on engine performance of change in jacket-water outlet temperature

Tests made on a Curtiss D-12 engine in the Altitude Laboratory at the Bureau of Standards show the following effects on engine performance of change in jacket-water outlet temperature: 1) Friction at all altitudes is a linear function of the jacket-water temperature, decreasing with increasing temperature. 2) The brake horsepower below an altitude of about 9,000 feet decreases, and at higher altitudes increases, with jacket-water temperature. 3) The brake specific fuel consumption tends to decrease, at all altitudes, with increasing jacket-water temperature. 4) The percentage change in brake power output is roughly equal to the algebraic sum of the percentage change in volumetric efficiency and mechanical efficiency.

Garlock, E A

Effects of vertical distribution of water vapor and temperature on total column water vapor retrieval error

Results are presented of a test of the physically based total column water vapor retrieval algorithm of Wentz (1992) for sensitivity to realistic vertical distributions of temperature and water vapor. The ECMWF monthly averaged temperature and humidity fields are used to simulate the spatial pattern of systematic retrieval error of total column water vapor due to this sensitivity. The estimated systematic error is within 0.1 g/sq cm over about 70 percent of the global ocean area; systematic errors greater than 0.3 g/sq cm are expected to exist only over a few well-defined regions, about 3 percent of the global oceans, assuming that the global mean value is unbiased.

Sun, Jielun

The role of large-scale atmospheric circulation in the formation of temperature anomalies in surface waters as illustrated by the northern part of the Pacific Ocean

One important reason for thermal anomalies in the ocean is the dynamic action of anomalous wind systems that set masses of surface water in motion; predominant longitudinal transport of water and air leads to a significant redistribution of cold and warm waters. Heat exchange between the ocean and atmosphere plays an additional role in the formation of water temperature anomalies.

Sorkina, A. I.