Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “water screening tool”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Handbook: Water Evaluation Tools

This document provides general instructions on performing a walk-through water survey to collect the required data for a comprehensive water evaluation and entering data into the online Water Balance Tool.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exploring Approaches for Accelerated Mass Spectrometric Detection of Fluorochemicals from Aqueous Solutions Using Indirect, Adsorbent-Facilitated Desorption Ionization

There is a growing need for rapid, low-cost analytical tools to screen water supplies for persistent contaminants. Due to their ubiquitous presence in the environment and their detrimental effects on human health, there is a public interest in widespread testing for perfluoroalkyl substances (PFAS). However, the most common methods for PFAS analysis can be time-intensive, requiring a preconcentration step followed by liquid chromatography–mass spectrometry (LC–MS), and are cost-prohibitive for most members of the public. To address these challenges, this study explores a novel method for rapid analysis of aqueous analytes by concentrating analytes on solid adsorbents and detecting them using mass spectrometric analysis via desorption ionization directly from the adsorbent surface. We demonstrate this general approach of indirect solution analysis (ISA) with desorption electrospray ionization (ISA-DESI) and laser desorption ionization (ISA-LDI). Various adsorbent materials were screened, including commercial mesoporous carbons, alumina, and metal–organic frameworks (MOFs). Using ISA-DESI, we consistently detect concentrations as low as 5–100 parts per trillion (ppt) for perfluorooctanoic acid (PFOA) and 10–100 ppt for perfluoroundecanoic acid (PFUnDA). This approach enables rapid detection in under 5 min, making it suitable for applications requiring trace detection with fast response times. We further demonstrate the use of ISA-DESI on a range of environmentally relevant contaminants. Advantages of this indirect solution analysis approach include simplified sample preparation, accelerated analysis, and low cost with readily available materials, making it a promising tool to accelerate mass spectrometric PFAS detection for identifying contaminated sites, performing laboratory studies, and monitoring industrial waste streams.

Bays, Nathan Robert [Sandia National Laboratories ↗

Technical Background and Validation Report on the Residential Water Inhalation Risk Calculator Presented in the Risk Assessment Information System

Indoor air quality (IAQ) is critical for human health. Poor IAQ is linked to respiratory issues, cardiovascular diseases, and cancer. Indoor pollutants are emitted by typical household items such as cleaning products, personal care items, building materials, and tap water - an understudied volatile organic compound (VOC) source. This document presents the Residential Water Inhalation Risk Calculator (RWIRC), which estimates daily VOC exposure concentrations from various household water uses, such as showering and dishwashing, to assess exposure risks for the most vulnerable occupant. Integrated into the Risk Assessment Information System (RAIS) and sponsored by the US Department of Energy (DOE), the calculator divides a house into three compartments: shower, bathroom, and other spaces, accounting for daily water usage patterns and calculating VOC concentrations. Exposure data generated using the calculator can assist health assessors in estimating excess lifetime cancer risk (ELCR) and hazard index (HI) from VOC inhalation. Unlike traditional exposure models that utilize Andelman’s constant, the RWIRC continuously assesses variability in VOC concentrations and environmental conditions using differential equations to track VOC concentrations and air exchange between compartments. The calculator also provides unique volatilization fractions for each chemical and appliance, enhancing accuracy of the exposure concentration estimation. The RWIRC is accessible online and allows users to customize parameters (i.e., number of bathrooms, water temperature, and exhaust fan conditions) and input VOC characteristics (i.e., tap water and ambient air concentrations). This document provides a step-by-step guide on implementing the calculator. It also provides comparisons with the ATSDR-SHOWER calculator, using eight VOCs with varying physicochemical properties to reveal differences in algorithms and output concentrations. Simulations also assess how bathroom door positions and exhaust fan usage affect VOC exposure. The calculator results can enhance EPA risk screening levels for inhalation exposure to VOCs from tap water, offering a sophisticated tool for assessing inhalation risks and improving public health protection.

54 ENVIRONMENTAL SCIENCES↗

Early Detection of Drought Stress in Durum Wheat Using Hyperspectral Imaging and Photosystem Sensing

Wheat, being the third largest U.S. crop and the principal food grain, faces significant risks from climate extremes such as drought. This necessitates identifying and developing methods for early water-stress detection to prevent yield loss and improve water-use efficiency. This study investigates the potential of hyperspectral imaging to detect the early stages of drought stress in wheat. The goal is to utilize this technology as a tool for screening and selecting drought-tolerant wheat genotypes in breeding programs. Additionally, this research aims to systematically evaluate the effectiveness of various existing sensors and methods for detecting early stages of water stress. The experiment was conducted in a durum wheat experimental field trial in Maricopa, Arizona, in the spring of 2019 and included well-watered and water-limited treatments of a panel of 224 replicated durum wheat genotypes. Spectral indices derived from hyperspectral imagery were compared against other plant-level indicators of water stress such as Photosystem II (PSII) and relative water content (RWC) data derived from proximal sensors. Our findings showed a 12% drop in photosynthetic activity in the most affected genotypes when compared to the least affected. The Leaf Water Vegetation Index 1 (LWVI1) highlighted differences between drought-resistant and drought-susceptible genotypes. Drought-resistant genotypes retained 43.36% more water in leaves under well-watered conditions compared to water-limited conditions, while drought-susceptible genotypes retained only 15.69% more. The LWVI1 and LWVI2 indices, aligned with the RWC measurements, revealed a strong inverse correlation in the susceptible genotypes, underscoring their heightened sensitivity to water stress in earlier stages. Several genotypes previously classified based on their drought resistance showed spectral indices deviating from expectations. Results from this research can aid farmers in improving crop yields by informing early management practices. Moreover, this research offers wheat breeders insights into the selection of drought-tolerant genotypes, a requirement that is becoming increasingly important as weather patterns continue to change.

Roy, Bishal (ORCID:0000000199125505)↗

The Risk Assessment Information System Compendium of Ecological Screening Benchmarks for Chemicals and Radionuclides (2025) (Volume I – Text, Radionuclides for all Media, Chemicals for Air and Biota)

The Risk Assessment Information System Ecological Benchmark Tool compiles screening level benchmark values for assessing potential ecological risks posed by chemical and radionuclide contaminants. Drawing from a wide array of federal, state, and international sources, it consolidates benchmarks across environmental media, including soil, water, sediment, air, and biota, and presents values for a broad range of receptors and exposure pathways. The tool includes both effect-based and no-effect thresholds, with media- and organism-specific guidance derived from peer-reviewed literature and regulatory frameworks. By integrating diverse benchmark types into a unified reference, the tool supports consistent, scientifically grounded evaluations in ecological risk assessments and environmental management practices.

54 ENVIRONMENTAL SCIENCES↗

A review of neutronics and thermal hydraulics–based screening methods applied to accelerated nuclear fuel qualification

This paper reviews the state-of-the-art engineering approach for using thermal hydraulic (TH) and neutronics modeling and simulation (M&S) tools to perform rapid screening studies of novel nuclear fuel concepts within the context of accelerated fuel qualification. Global research efforts have introduced nuclear fuel and material concepts that mark a significant departure from traditional reactor materials. The number of new technologies being considered for development for light water reactors and advanced reactor types has created the need for an accelerated fuel qualification procedure. A key component of this procedure is the rapid identification of the most promising fuel concepts using computational screening studies. Advanced TH and neutronic M&S tools should be leveraged to efficiently determine whether the reactor performance and safety characteristics of a given concept warrant additional studies or whether the concept requires modification or elimination. This paper reviews best practices for performing these TH and neutronics screening studies at various stages during a fuel concept's progression through the qualification procedure. The motivation behind standardizing this approach is to minimize time and resources spent on qualification activities for fuel concepts that could be quickly refined or eliminated from consideration based on their reactor physics and TH characteristics. Adoption of this screening procedure—which focuses primarily on nuclear fuels but may be applicable to other reactor materials—will also help accelerate new material qualification by generating boundary conditions crucial to fuel performance evaluations and highlighting needed areas of separate effects experimentation. This article reviews the motivation behind the introduction of novel nuclear fuel concepts, provides incentive for utilizing TH- and neutronics-based screening studies, describes the screening approach and methodology, and includes discussion on how to interpret screening results to provide recommendations for the continued development of a given concept.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NEWTS Economic Data Dashboard: Critical Materials for Energy

The NEWTS Economic Data Dashboard: Critical Materials for Energy is an economic screening tool for assessing the concentration and potential value of the 18 critical materials for energy in fossil energy-related wastewater across the United States. Datasets used to develop the dashboard and complete economic calculations are available as supplementary downloads. These resources were developed primarily using geochemical composition and volume data from the NEWTS Integrated dataset (version 1.0). Energy-related wastewater types presented in the dashboard include produced water (PW), brackish groundwater (BW), acid mine drainage (AMD), coal combustion residual leachate (CCRL), power plant flue gas desulfurization wastewater (FGD), and geothermal fluids. The concentrations of the following critical minerals were included in the analysis, when available: Al, Co, Cu, Dy, F, Ga, Ge, C, Ir, Li, Mg, Mn, Nd, Ni, Pt, Pr, Si, Tb. This economic screening tool was built to support identification of promising critical mineral feedstocks and economic research targets.

Critical Minerals; Critical Minerals and Materials↗

Fast and Accurate Machine Learning Strategy for Calculating Partial Atomic Charges in Metal–Organic Frameworks

Computational high-throughput screening using molecular simulations is a powerful tool for identifying top-performing metal–organic frameworks (MOFs) for gas storage and separation applications. Accurate partial atomic charges are often required to model the electrostatic interactions between the MOF and the adsorbate, especially when the adsorption involves molecules with dipole or quadrupole moments such as water and CO 2 . Although ab initio methods can be used to calculate accurate partial atomic charges, these methods are impractical for screening large material databases because of the high computational cost. We developed a random forest machine learning model to predict the partial atomic charges in MOFs using a small yet meaningful set of features that represent both the elemental properties and the local environment of each atom. The model was trained and tested on a collection of about 320 000 density-derived electrostatic and chemical (DDEC) atomic charges calculated on a subset of the Computation-Ready Experimental Metal–Organic Framework (CoRE MOF-2019) database and separately on charge model 5 (CM5) charges. The model predicts accurate atomic charges for MOFs at a fraction of the computational cost of periodic density functional theory (DFT) and is found to be transferable to other porous molecular crystals and zeolites. In conclusion, a strong correlation is observed between the partial atomic charge and the average electronegativity difference between the central atom and its bonded neighbors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Heat Pump Retrofits for Central Plant Hydronic Heating Systems: A Software Toolkit for Screening and Design

Retrofitting existing central plants with high-efficiency heat pump technologies can play a crucial role in achieving long-term planning goals. Modern heat pump technologies are able to use waste heat recovery to meet a building's heating demand, but there is a lack of accessible tools designed for non-HVAC experts, such as building owners, to quickly and easily conduct what-if analysis, e.g., estimating retrofit costs and payback period for their partial or full equipment replacement. This paper introduces an open-source software toolkit designed to facilitate the initial screening and decision-making of heat pump retrofits in existing central plants using a building's yearly load profile from metered or utility bill data. The toolkit evaluates the technical and economic viability of replacing traditional central plant equipment with various options including water-to-water or air-to-water heat pumps, which can provide efficient and lower-cost heating and cooling. It allows users to compare current central plant configurations with retrofit scenarios, assessing energy consumption, life-cycle costs, and environmental impact. The toolkit offers (1) a web-based tool designed for user-friendly access by a broad audience and (2) Python-based source code for researchers and engineers conducting parametric studies and design parameter optimization. The toolkit compares a typical central plant configuration to a configuration that uses a heat pump to supply hydronic heating and cooling. The output metrics include energy consumption and output of each equipment, life-cycle cost analyses and metrics, and environmental impact of the system.

Excell, L↗

Activation dynamics of a water-soluble human mu-opioid receptor

The mu-opioid receptor (MOR), a class A G protein-coupled receptor mediates opioid analgesia and remains a central target for pain therapeutics. While crystal structures of MOR exist, they provide limited insight into the receptor’s dynamic conformational landscape underlying function. Here, we engineered a thermostable water-soluble MOR variant (wsMOR) that retains native-like ligand-binding and activation dynamics. This variant enables high-yield production and detailed solution-phase structural studies that are challenging with membrane-embedded MOR, providing a valuable tool for studying receptor activation and aqueous-phase drug screening. Using a combined computational and experimental approach, we performed long-timescale all-atom molecular dynamics simulations together with neutron scattering and single-molecule FRET, revealing a structurally stable receptor with a diverse ensemble of conformations at different temporal resolutions. In the ligand-free state, wsMOR displayed high conformational flexibility, which decreased upon agonist binding, particularly in transmembrane helix 6, a hallmark of G protein-coupled receptor activation. Positive allosteric modulation and G protein binding further stabilized active-like states. These findings highlight wsMOR’s conformational plasticity across picosecond to millisecond timescales and provide a foundation for structure-guided development of next-generation opioid ligands with improved efficacy and safety.

E, Agyemang [University of Tennessee Knoxville]↗

A Multi-criteria CCUS Screening Evaluation of the Gulf of Mexico, USA - Supplementary Data

The Wendt et al. study aims to incorporate multiple and disparate carbon capture, utilization, and storage (CCUS) decision-making criteria into a systematic, quantitative analytical approach to help identify areas with potentially high suitability to serve as offshore CO2 storage or EOR regions. Spatially-distributed data from publicly-available sources within the Gulf of Mexico (GOM) study area (limited to federal waters; state waters were not evaluated) was compiled using the U.S. Department of Energy's (DOE) National Energy Technology Laboratory (NETL) Cumulative Spatial Impact Layers™ (CSIL) tool to easily aggregate data based on evenly-distributed grids across the study region set at a resolution of approximately 25 square miles (65 square kilometers). The data included in this Microsoft Excel™ workbook provide the aggregated scores for each grid point across the study domain as well the weighting for each criterion under the four scenarios evaluated.

CCUS↗

Determination of transition metal ions in fossil fuel associated wastewaters using chelation ion chromatography

Here, this study outlines the development and subsequent validation of a method using chelation ion chromatography (CIC) pretreatment followed by traditional ion chromatography (IC) and post column UV/vis detection to measure transition metals in fossil fuel wastewaters, such as oil & gas (O&G) brines and coal mine drainage (CMD) waters. Measurement of transition metals is often an important characterization step in the research of environmental and energy systems. IC represents one way to measure these metals with the advantages of being versatile, simple and relatively low cost compared to other analytical methods. However, high concentrations of alkali and alkaline earth metals present in fossil fuel wastewaters will decrease IC detectability of transition metals in these waters. In this study, a CIC method was developed for the analysis of transition metal ions (Fe 3+ , Cu 2+ , Ni 2+ , Zn 2+ , Co 2+ , Mn 2+ , and Fe 2+ ) in fossil fuel associated wastewaters such as Appalachian CMD and O&G wastewaters from the Permian and Bakken shale basins in the United States. CIC system incorporated an on-line chelator column (e.g., the MetPac CC-1) with high selectivity for transition metals over alkali and alkaline earth metals for salt matrix removal prior to transition metal separation and detection. Additional method developments also included acidifying all samples to 2% v/v HCl and using gradient elution rather than isocratic. The recoverability of transition metals in simple salt solutions commonly found in CMD and brine samples (e.g. NaCl, Na 2 SO 4 , CaCl 2 ) using CIC was evaluated and compared to that using traditional IC. Our results found that the CIC system significantly improved transition metal recoveries for samples in 10,000 mg/L CaCl 2 matrix, reaching 87%-108% recovery for all analytes, as opposed to 2-323% recovery in traditional IC. The limits of detection in this study achieved 10.09 – 161.2 μg/L, comparable to reported values in similar IC studies. The developed method was also verified with certified water samples, resulting in 89% - 111% recoveries in samples with higher analyte concentrations (i.e. >4x the LoDs). The developed method achieved 87% -112% recoveries for most analytes in CMD samples and 72%-138% recoveries for Bakken shale samples, relative to ICP-MS values. Overall, the current IC method can be a very good screening tool for fast and cheap analysis for transition metals at mg/L level, to facilitate selection of samples for more detailed ICP-MS analysis.

01 COAL, LIGNITE, AND PEAT↗

An automatic gore panel mapping system

The Automatic Gore Mapping System is being developed to reduce the time and labor costs associated with manufacturing the External Tank. The present chem-milling processes and procedures are discussed. The down loading of the simulation of the system has to be performed to verify that the simulation package will translate the simulation code into robot code. Also a simulation of this system has to be programmed for a gantry robot instead of the articulating robot that is presently in the system. It was discovered using the simulation package that the articulation robot cannot reach all the point on some of the panels, therefore when the system is ready for production, a gantry robot will be used. Also a hydrosensor system is being developed to replace the point-to-point contact probe. The hydrosensor will allow the robot to perform a non-contact continuous scan of the panel. It will also provide a faster scan of the panel because it will eliminate the in-and-out movement required for the present end effector. The system software is currently being modified so that the hydrosensor will work with the system. The hydrosensor consists of a Krautkramer-Branson transducer encased in a plexiglass nozzle. The water stream pumped through the nozzle is the couplant for the probe. Also, software is being written so that the robot will have the ability to draw the contour lines on the panel displaying the out-of-tolerance regions. Presently the contour lines can only be displayed on the computer screens. Research is also being performed on improving and automating the method of scribing the panels. Presently the panels are manually scribed with a sharp knife. The use of a low power laser or water jet is being studied as a method of scribing the panels. The contour drawing pen will be replaced with scribing tool and the robot will then move along the contour lines. With these developments the Automatic Gore Mapping Systems will provide a reduction in time and labor costs associated with manufacturing the External Task. The system also has the potential of inspecting other manufactured parts.

Shiver, John D.↗

Natural Charge-Transfer Analysis: Eliminating Spurious Charge-Transfer States in Time-Dependent Density Functional Theory via Diabatization, with Application to Projection-Based Embedding

For many types of vertical excitation energies, linear-response time-dependent density functional theory (LR-TDDFT) offers a useful degree of accuracy combined with unrivaled computational efficiency, although charge-transfer excitation energies are often systematically and dramatically underestimated, especially for large systems and those that contain explicit solvent. As a result, low energy electronic spectra of solution-phase chromophores often contain tens to hundreds of spurious charge-transfer states, making LR-TDDFT needlessly expensive in bulk solution. More nefariously, intensity borrowing by the low-energy charge-transfer states can affect intensities of the valence excitations even if those excitation energies are accurate. At higher excitation energies, it is difficult to distinguish spurious CT states from genuine charge-transfer-to-solvent (CTTS) excitations. In this work, we introduce an automated diabatization scheme that enables fast and effective screening of the CTTS acceptor space in bulk solution. Our procedure introduces the concept of “natural charge-transfer orbitals”, which provide a means to isolate characteristic pairs of orbitals that are most likely to participate in a CTTS excitation. The projection of these orbitals onto solvent-centered virtual orbitals provides a criterion for defining the most important solvent molecules in a given excitation. We apply this method to analyze an ab initio molecular dynamics (MD) trajectory of I-(aq) and report the lowest-energy CTTS band in the absorption spectrum. Our results are in excellent agreement with experimental measurements for bulk I-(aq), and only one-third of the water molecules in the I-(H2O)96 simulation cell need to be described with LR-TDDFT in order to obtain excitation energies that are converged to < 0.1 eV. The tools introduced herein will improve the accuracy, efficiency, and usability of LR-TDDFT in solution-phase environments

Carter-Fenk, Kevin D.↗

Soil, Foodstuffs, and Biota Program [Slides]

We use several environmental monitoring tools to assess ecosystem health and in part, risk to human health. Generally, the concentrations of chemicals we observe are below background and screening levels. All of our monitoring data are available in Intellus, and our analyses and results are reported in the Annual Site Environmental Report. Our program is only one of several monitoring programs at LANL, others include air, surface water, ground water, canyon sediments. We strive to improve the program by incorporating new monitoring techniques, monitoring new locations, monitoring new chemicals of interest, and by using robust statistical analyses.

54 ENVIRONMENTAL SCIENCES↗

From Obsolete to Optimal (ATR Demineralized Water System)

My project was migrating a Human-Machine Interface (HMI) and Programmable Logic Controller (PLC) program from legacy software to a modern platform, enhancing operational efficiency and eliminating unsupported, obsolete equipment. Initially, I used a migration tool to transfer the programs to the new software, then manually updated variables to align with the new PLC. I optimized the PLC code by leveraging new scaling features in the I/O cards, removing over 45 obsolete rungs, and enhancing clarity with functional tag aliases. Next, I modernized the HMI's visuals with an updated color scheme and 3D buttons. I developed multiple interface versions iteratively refining them based on operator feedback. I also designed and created a dedicated "Rounds" screen incorporating insights from a previous intern’s project to streamline daily rounds. To improve clarity, consistency, and efficiency I redesigned the entire interface. Adding visual indicators to enhance operational awareness: red is used for values outside normal specifications, green for normal operating modes, yellow for manual mode, and grey for offline units. Additionally, I added a dynamic visual representation of tank levels, creating PLC logic to show the level in inches as well as inches and feet. I then incorporated a navigation sidebar to facilitate efficient screen transitions. Risk of human error was mitigated by defining narrow input ranges for tank level shutoff and password protecting setpoint changes. I also fixed issues with datatypes that caused inaccuracies in the original code. Overall, this comprehensive upgrade significantly enhanced the HMI's functionality, user experience, and operational reliability.

47 - OTHER INSTRUMENTATION↗

Data from: "Towards CONUS-Wide ML-Augmented Conceptually-Interpretable Modeling of Catchment-Scale Precipitation-Storage-Runoff Dynamics"

This data package was generated to support the manuscript “Towards CONUS-Wide Machine Learning-Augmented Conceptually Interpretable Modeling of Catchment-Scale Precipitation-Storage-Runoff Dynamics.” It provides input files, model outputs, plotting data, scripts, notebooks, and documentation used to develop, evaluate, and reproduce Mass-Conserving Perceptron (MCP)-based hydrologic modeling experiments across 513 selected Catchment Attributes and Meteorology for Large-sample Studies in the United States (CAMELS-US) basins. The files are organized by modeling component and analysis purpose, including rainfall–runoff experiments, snow module experiments, coupled hydrologic-snow experiments, Long Short-Term Memory (LSTM) benchmark results, model skill metrics, initialization and epoch records, cell-state normalization files, Akaike Information Criterion (AIC)-based model comparison files, and data used to generate manuscript figures. Tabular files can be opened using standard spreadsheet software or Python/R data-analysis tools. Python scripts, Jupyter notebooks, and selected MATLAB scripts are included for model execution, postprocessing, plotting, and statistical analysis. Quality assurance and quality control were conducted through the source-data selection and modeling workflow. Meteorological forcing, streamflow, and static catchment attributes were derived from the CAMELS-US dataset, and snow water equivalent data were derived from the University of Arizona (UA) Snow Water Equivalent dataset. Selected basins and time periods were screened during the associated research workflow to avoid missing observations or poor-quality cases. Static geospatial features were processed primarily using Quantum Geographic Information System (QGIS) and Geospatial Data Abstraction Library (GDAL) workflows. Additional details are provided in the associated manuscript and documentation.

ESS-DIVE CSV File Formatting Guidelines Reporting ↗