Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “waste glass melter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Predictive modeling of crystal accumulation in high-level waste glass melters processing radioactive waste

The effectiveness of HLW vitrification is limited by precipitation/accumulation of spinel crystals [(Fe, Ni, Mn, Zn)(Fe, Cr)2O4] in the glass discharge riser of Joule-heated ceramic melters during idling. These crystals do not affect glass durability; however, if accumulated in thick layer, they can clog the melter and prevent discharge of molten glass into canisters. To address this problem, an empirical model was developed that can predict thicknesses of accumulated layers as a function of glass composition. This model predicts well the accumulation of single crystals and/or small-scale agglomerates, but, excessive agglomeration observed in high-Ni-Fe glass resulted in an under-prediction of accumulated layers, which gradually worsen over time as an increased number of agglomerates formed. Accumulation rate of ~53.8 ± 3.7 µm/h determined for this glass will result in ~26 mm thick layer in 20 days of melter idling.

Crystal accumulation↗

Computational Fluid Dynamics Modeling of Bubbling in a Viscous Fluid for Validation of Waste Glass Melter Modeling

At the Hanford site, radioactive waste stored in underground tanks is slated for vitrification for final disposal. A comprehensive knowledge of the glass batch melting process will be useful in optimizing the process, which could potentially reduce the cost and duration of this multi-billion dollar cleanup effort. We are developing a high-fidelity heat transfer model of a Joule-heated ceramic lined melter to improve the understanding of the complex, inter-related processes occurring with the melter. The glass conversion rates in the cold cap layer are dependent on promoting efficient heat transfer. In practice, heat transfer is augmented by inserting air bubblers into the molten glass. However, the computational simulations must be validated to provide confidence in the solutions. As part of a larger validation procedure, it is beneficial to split the physics of the melter into smaller systems to validate individually. The substitution of molten glass for a simulant liquid with similar density and viscosity at room temperature provides a way to study mixing through bubbling as an isolated effect without considering the heat transfer dynamics. The simulation results are compared to experimental data obtained by the Vitreous State Laboratory at the Catholic University of America using bubblers placed within a large acrylic tank that is similar in scale to a pilot glass waste melter. Comparisons are made for surface area of the rising air bubbles between experiments and CFD simulations for a variety of air flow rates and bubble injection depths. Also, computed bubble rise velocity is compared to a well-accepted expression for bubble terminal velocity (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Computational Fluid Dynamics Modeling of Bubbling in a Viscous Fluid for Validation of Waste Glass Melter Modeling

At the Hanford site, radioactive waste stored in underground tanks is slated for vitrification for final disposal. A comprehensive knowledge of the glass batch melting process will be useful in optimizing the process, which could potentially reduce the cost and duration of this multi-billion dollar cleanup effort. We are developing a high-fidelity heat transfer model of a Joule-heated ceramic lined melter to improve the understanding of the complex, inter-related processes occurring with the melter. The glass conversion rates in the cold cap layer are dependent on promoting efficient heat transfer. In practice, heat transfer is augmented by inserting air bubblers into the molten glass. However, the computational simulations must be validated to provide confidence in the solutions. As part of a larger validation procedure, it is beneficial to split the physics of the melter into smaller systems to validate individually. The substitution of molten glass for a simulant liquid with similar density and viscosity at room temperature provides a way to study mixing through bubbling as an isolated effect without considering the heat transfer dynamics. The simulation results are compared to experimental data obtained by the Vitreous State Laboratory at the Catholic University of America using bubblers placed within a large acrylic tank that is similar in scale to a pilot glass waste melter. Comparisons are made for surface area of the rising air bubbles between experiments and CFD simulations for a variety of air flow rates and bubble injection depths. Also, computed bubble rise velocity is compared to a well-accepted expression for bubble terminal velocity.

bubbling↗

Use of X-Ray Tomography to Elucidate Cold Cap Structure in Waste Glass Melter

In a waste glass melter, the cold cap plays a vital role in establishing the melt rate for a particular melter feed. Data from x-ray tomography of laboratory-scale cold caps provide insight into the topology of bubble distribution within the cold cap for various feed compositions at temperatures from 600°C to 1040°C. The images were thresholded to capture features of interest, then processed by software to obtain statistics that can be used to characterize bubble topology. Statistics obtained include total pellet volume, porosity, bubble size distribution and morphology as a function of temperature. These statistics will be used to compare the melting behavior of the different glass formulations as a function of temperature. Information on bubble topology at various temperatures will be used to synthetically generate a cold cap structure that can be used to model heat transfer through the cold cap layer.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Bubbling Behavior in a Waste Glass Melter

Legacy tank waste from five decades of plutonium production at the Hanford Site during the Cold War will be vitrified into a stable waste form for disposal. A Waste Treatment Plant, currently under construction, houses Joule heated ceramic-lined waste glass melters wherein radioactive waste will be combined with glass formers to produce borosilicate glass. Through testing conducted in pilot-scale melters with surrogate waste, as well as operational experience at other sites, it has been demonstrated that the use of bubblers can dramatically improve the glass production rate. However, knowledge of the bubble dynamics in the molten glass is necessary for prediction and design of improved melting processes. A computational fluid dynamics model of the melter has been developed to investigate the processes affecting feed melt rate. The model shows that the convection currents within the melt pool due to Joule heating supplied by the electrodes are enhanced by forced air bubbling. In this paper, parameters influencing the formation and rise of a bubble stream in a viscous liquid are investigated. Experimental data and observations from laboratory and pilot-scale testing are integrated with first principles to develop a set of equations that form a mechanistic bubbling model to be incorporated into the melter model.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Numerical comparison of bubbling in a waste glass melter

Radioactive tank waste is scheduled for vitrification at the Hanford Tank Waste Treatment and Immobilization Plant, also known as the Vit Plant, being constructed at the Hanford Site. Testing of the pilot-scale, joule-heated DuraMelter 1200 at the Vitreous State Laboratory has shown that bubbling increases the melt rate, and as a result, melter throughput. Computational fluid dynamics (CFD) models of this pilot-scale waste glass melter were developed to improve our understanding of the processes that occur within the melter to aid in process optimization and troubleshooting of the Vit Plant melters. Unfortunately, model validation is complicated by the difficulty of obtaining suitable experimental data for operational melters attributed to the large-scale, radioactivity and high temperatures at which these melters are operated. This study focuses on confirming the fidelity of the CFD models to accurately reproduce the bubbling behavior. Because of the paucity of experimental data at the resolution required for CFD validation, a code-to-code comparison was used to evaluate two common approaches for simulating flows of immiscible fluids on numerical grids and resolving multiphase interfaces. Here, the volume of fluid and level set methods are used to track the dynamically evolving interfaces between the molten glass and the air bubbles. To aid in the verification of the results of these codes, a comparison of the bubble behavior, growth, and frequency of bubble generation are presented and a grid convergence study is performed for the two approaches. In addition to comparing the numerical results to available experimental data and observations from pilot-scale testing, the results are evaluated in relation to laboratory experiments with bubbles injected into viscous fluids, empirical correlations obtained from the published literature, and the basic laws of fluid dynamics. Furthermore, the results of this work can assist in validating waste glass melter models and provide a better understanding of the flow patterns within the WTP melters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Chrome Refractory Characterization: Part II . Accumulation of Spinel Corrosion Deposits in Radioactive Waste Glass Melters

High Cr 2 O 3 containing Monofrax ™ K‐3 is a robust refractory that is used in radioactive waste glass melters worldwide. Monofrax ™ K‐3 contains highly reduced phases. Conversely, many of the radioactive feeds being processed are highly oxidizing. The K‐3 refractory corrosion rates in oxidizing (high nitrate) feeds were ~1.8–2.8 times higher than the rates determined using reducing feeds. The corrosion product formed is a mixture of spinel and glass (slag) that can accumulate on the melter floor. A methodology to calculate the depth of slag deposits from refractory corrosion is presented and verified with slag measurements from the Defense Waste Processing Facility ( DWPF ) melter after it had processed oxidized feeds for 1.75 years. The calculations show that had the facility continued to process oxidized feeds the melter lifetime (based on when the deposits could have reached and blocked the pour spout riser) would have been ~4.5 years. The DWPF changed to a reducing flow sheet after ~3 years of operation. The lifetimes of Melter #1 and Melter #2, assuming a failure due to pour spout blockage, are calculated as 7.7–12 years based on corrosion rates measured with reducing feeds. Lifetimes of 9 and >11 years have actually been achieved.

Jantzen, Carol M.↗

Incorporating Cold Cap Behavior in a Joule-heated Waste Glass Melter Model

In this paper, an overview of Joule-heated waste glass melters used in the vitrification of high level waste (HLW) is presented, with a focus on the cold cap region. This region, in which feed-to-glass conversion reactions occur, is critical in determining the melting properties of any given glass melter. An existing 1D computer model of the cold cap, implemented in MATLAB, is described in detail. This model is a standalone model that calculates cold cap properties based on boundary conditions at the top and bottom of the cold cap. Efforts to couple this cold cap model with a 3D STAR-CCM+ model of a Joule-heated melter are then described. The coupling is being implemented in ModelCenter, a software integration tool. The ultimate goal of this model is to guide the specification of melter parameters that optimize glass quality and production rate.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

THERMAL ANALYSIS OF WASTE GLASS MELTER FEEDS

Melter feeds for high-level nuclear waste (HLW) typically contain a large number of constituents that evolve gas on heating, Multiple gas-evolving reactions are both successive and simultaneous, and include the release of chemically bonded water, reactions of nitrates with organics, and reactions of molten salts with solid silica. Consequently, when a sample of a HLW feed is subjected to thermogravimetric analysis (TGA), the rate of change of the sample mass reveals multiple overlapping peaks. In this study, a melter feed, formulated for a simulated high-alumina HLW to be vitrified in the Waste Treatment and Immobilization Plant, currently under construction at the Hanford Site in Washington State, USA, was subjected to TGA. In addition, a modified melter feed was prepared as an all-nitrate version of the baseline feed to test the effect of sucrose addition on the gas-evolving reactions. Activation energies for major reactions were determined using the Kissinger method. The ultimate aim of TGA studies is to obtain a kinetic model of the gas-evolving reactions for use in mathematical modeling of the cold cap as an element of the overall model of the waste-glass melter. In this study, we focused on computing the kinetic parameters of individual reactions without identifying their actual chemistry, The rough provisional model presented is based on the first-order kinetics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Computational Fluid Dynamics Simulation of a Pilot-Scale Waste Glass Melter

The INL has been developing a high-fidelity computational fluid dynamics (CFD) model of a Joule-heated ceramic-lined waste glass melter. The purpose is to better understand the dynamics of heat transfer within the system, in order to provide support for the optimization of the Hanford Waste Treatment Plant (WTP) that will be used for vitrification of legacy tank waste. The simulation presented here is for the DM1200 pilot-scale system, which has been operated by the Vitreous State Laboratory (VSL) over the past several decades. This system is about one-third of the scale of the full size WTP melter. Experimental data from this system is being used to validate computational simulations. The examination of the melter with a fully coupled CFD model should give an accurate assessment of the heat transfer into the reactive cold cap region. Heat is provided to the cold cap region from conduction and convection from the molten glass pool as well as radiation from the hot plenum above the cold cap. The CFD model implements a mathematical model of the cold cap developed for the assessment of the melting rate during the vitrification of tank waste. This sub-model implemented directly into the CFD model combines the mass and enthalpy balance of the cold cap together with the conversion kinetics of the feed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Heat Transfer Model of a Small-Scale Waste Glass Melter with Cold Cap Layer

At the Hanford site in the state of Washington, more than 56 million gallons of radioactive waste is stored in underground tanks. The cleanup plan for this waste is vitrification at the Waste Treatment Plant (WTP), currently under construction. At the WTP, the waste will be blended with glass-forming materials and heated to 1423K, then poured into stainless steel canisters to cool and solidify. A fundamental understanding of the glass batch melting process is needed to optimize the process to reduce cost and decrease the life cycle of the cleanup effort. The cold cap layer that floats on the surface of the glass melt is the primary reaction zone for the feed-to-glass conversion. The conversion reactions include water release, melting of salts, evolution of batch gases, dissolution of quartz and the formation of molten glass. Obtaining efficient heat transfer to this region is crucial to achieving high rates of glass conversion. Computational fluid dynamics (CFD) modeling is being used to understand the heat transfer dynamics of the system and provide insight to optimize the process. A CFD model was developed to simulate the DM1200, a pilot-scale melter that has been extensively tested by the Vitreous State Laboratory (VSL). Electrodes are built into the melter to provide Joule heating to the molten glass. To promote heat transfer from the molten glass into the reactive cold cap layer, bubbling of the molten glass is used to stimulate forced convection within the melt pool. A three-phase volume of fluid approach is utilized to model the system, wherein the molten glass and cold cap regions are modeled as separate liquid phases, and the bubbling gas and plenum regions are modeled as one lumped gas phase. The modeling of the entire system with a volume of fluid model allows for the prescription of physical properties on a per-phase basis. The molten glass phase and the gas phase physical properties are obtained from previous experimental work. Finding representative properties for the cold cap region is more difficult, as this region is not a true liquid, but rather a multilayer region consisting of a porous and a foamy layer. Physical properties affecting heat transfer, namely the thermal conductivity and heat capacity, have been fit to closely match data and observations from laboratory experiments. Data from xray tomography and quenching of laboratory-scale cold caps provide insight into the topology of bubble distribution within the cold cap at various temperatures. Heat transfer within the melter was validated by comparison with VSL data for the pilot-scale melter.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Heat transfer enhancement due to cold cap motion from bubbling in a waste glass melter

In this study, a computational fluid dynamics (CFD) model was developed to model the motion of a solid cold cap in a waste glass melter. Forced convection bubblers at the base of the melter release air into the molten glass, which forms large bubbles that travel upwards to the cold cap and augment heat transfer from the glass to the cold cap. The CFD model employs the Navier- Stokes equations to solve for the fluctuating flowfield using a rigid body motion dynamic fluid body interaction module. This allows for movement of the floating body in response to the bubbling forces calculated at each time step. Further, the heat flux delivered to the cold cap by the convective bubbling is studied as a function of the bubbling rate. Results for the moving cold cap are compared with the computed heat flux trends for a stationary cold cap. The heat flux delivered to the cold cap from the glass is 25% higher for the case with the moving cold cap. The heat flux was found to be proportional to v0.6 as opposed to v0.9 (where v is the normalized bubbling rate) for the stationary cold cap.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a Validation Approach for an Integrated Waste Glass Melter Model

Integrated models are being developed to represent the physics occurring within the high-level and low-activity waste melters that will be used to vitrify legacy tank waste at the Hanford site. These models couple the melt pool, cold cap, and plenum region within a single computational domain. Validation of the models is essential to ensure the reliability of the numerical predictions of the operational melters. Experimental data from laboratory- and pilot-scale tests are thus being used to inform and validate various aspects of the melter model. This study presents a tiered approach to model validation consisting of a series of progressively more complex test cases designed to model the physics occurring in the full-scale system. A hierarchical methodology has been developed to segregate and simplify the physical phenomena affecting the multiphase flow and heat transfer within a waste glass melter. Finally, four hierarchical levels are defined in a validation pyramid and built up in levels of increasing complexity from unit problems to subsystem cases, to pilot-scale systems, and then to the full-scale system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determination of heat conductivity and thermal diffusivity of waste glass melter feed: Extension to high temperatures

The heat conductivity ({lambda}) and the thermal diffusivity (a) of reacting glass batch, or melter feed, control the heat flux into and within the cold cap, a layer of reacting material floating on the pool of molten glass in an all-electric continuous waste glass melter. After previously estimating {lambda} of melter feed at temperatures up to 680 deg C, we focus in this work on the {lambda}(T) function at T > 680 deg C, at which the feed material becomes foamy. We used a customized experimental setup consisting of a large cylindrical crucible with an assembly of thermocouples, which monitored the evolution of the temperature field while the crucible with feed was heated at a constant rate from room temperature up to 1100°C. Approximating measured temperature profiles by polynomial functions, we used the heat transfer equation to estimate the {lambda}(T) approximation function, which we subsequently optimized using the finite-volume method combined with least-squares analysis. The heat conductivity increased as the temperature increased until the feed began to expand into foam, at which point the conductivity dropped. It began to increase again as the foam turned into a bubble-free glass melt. We discuss the implications of this behavior for the mathematical modeling of the cold cap.

36 MATERIALS SCIENCE↗

A Predictive Model for Offgas Composition in Waste Glass Melters - Spring 2021 SULI General Audience Abstract

Approximately 56 million gallons of nuclear waste are currently stored in 177 underground storage tanks at the Hanford site in Washington state. A portion of the tank waste is targeted for immobilization by converting the nuclear waste to borosilicate glass through a process called vitrification. During vitrification, emissions are produced in addition to the intended glass product. These emissions, contained in a volume above the molten glass called the plenum, are composed of water vapor, air components, aerosols, particulates, and other gaseous species that result from evaporation, reactions, and air influx. The formation of these gasses causes the surface of the glass to foam. To reduce foaming, sucrose is added to the waste stream before the conversion to glass. Sucrose also reduces the formation of hazardous gasses in the plenum including nitrous oxides, NOx, and carboxides, COx. However, if excess sucrose is present, the reactions that produce the gasses in the plenum will be incomplete, and increased levels of NOx and COx can be observed. The Waste Treatment and Immobilization Plant at the Hanford site is equipped with the technology to treat the plenum emissions. Though many tests have been run to determine the presence of particulates in the plenum emissions, there is does not exist an established method to confidently predict the composition of the gaseous species in the plenum prior to treatment without physical testing. A model was created in the process modeling software Aspen Plus to predict the composition of NOx and COx in the plenum. The model employs a constant stirred tank reactor and user-defined reaction chemistry to determine the plenum composition. To verify the model, the offgas predicted by the model were compared to available offgas data for ten different feed compositions. It is demonstrated that the developed Aspen Plus model is capable of predicting the composition of NOx and COx in the plenum.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Computationally-Aided Design of a Small-Scale Radioactive Waste Glass Melter

To provide mission support to the Hanford Waste Immobilization and Treatment Plant for the vitrification of legacy nuclear tank waste, a reduced-scale vitrification pilot system is being designed to process simulated and actual radioactive tank wastes. The tank waste will be separated into high-level waste (HLW) and low-activity waste (LAW) fractions, where the majority by mass (~90%) is LAW and by activity (>95%) is HLW. The first tank waste to be processed at the WTP will be LAW. Since Hanford tank waste and the resultant melter feed compositions are known to vary widely, pilot-scale operations are essential to identify potential problems, provide needed data, confirm assumptions, and determine impacts to full-scale melters and off-gas systems from these different feeds. In addition, the reduced-scale melter system must be capable of quickly providing results to operations without the typically high costs of radioactive operations and provide an engineering platform in close proximity to local operations staff. The objective is to produce similar process conditions to those encountered in the full-scale LAW melters and minimize the volume of radioactive waste necessary for the evaluations. To this end, melter design features are being explored to increase production without significantly increasing surface area, melter glass volumes or compromising data quality. In support of these objectives, a set of computational fluid dynamic models have been developed to provide insight into the flow patterns within these small melters and evaluate design features to increase production without significantly increasing glass inventory. Computed velocities were evaluated at the interface between the cold cap and the molten glass pool and within the bulk glass pool. A method was developed to correlate results to an estimated melt rate and down-select design features that produce the highest gains.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Computationally-Aided Design of a Small-Scale Radioactive Waste Glass Melter

To provide mission support to the Hanford Waste Immobilization and Treatment Plant for the vitrification of legacy nuclear tank waste, a reduced-scale vitrification pilot system is being designed to process simulated and actual radioactive tank wastes. The tank waste will be separated into high-level waste (HLW) and low-activity waste (LAW) fractions, where the majority by mass (~90%) is LAW and by activity (>95%) is HLW. The first tank waste to be processed at the WTP will be LAW. Since Hanford tank waste and the resultant melter feed compositions are known to vary widely, pilot-scale operations are essential to identify potential problems, provide needed data, confirm assumptions, and determine impacts to full-scale melters and off-gas systems from these different feeds. In addition, the reduced-scale melter system must be capable of quickly providing results to operations without the typically high costs of radioactive operations and provide an engineering platform in close proximity to local operations staff. The objective is to produce similar process conditions to those encountered in the full-scale LAW melters and minimize the volume of radioactive waste necessary for the evaluations. To this end, melter design features are being explored to increase production without significantly increasing surface area, melter glass volumes or compromising data quality. In support of these objectives, a set of computational fluid dynamic models have been developed to provide insight into the flow patterns within these small melters and evaluate design features to increase production without significantly increasing glass inventory. Computed velocities were evaluated at the interface between the cold cap and the molten glass pool and within the bulk glass pool. A method was developed to correlate results to an estimated melt rate and down-select design features that produce the highest gains.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Computationally Aided Design of a Small-Scale Waste-Glass Melter - 20452

To provide mission support to the WTP for the vitrification of legacy nuclear tank waste at the Hanford site, a reduced-scale vitrification pilot system is being designed to process simulated and actual radioactive tank wastes. The waste stored in underground tanks will be separated into HLW and LAW fractions, where the majority is LAW by mass (approximately 90%) and HLW by activity (greater than 95%). The first tank waste to be processed at the WTP will be LAW. Because Hanford tank waste and the resultant melter feed compositions are known to vary widely, pilot-scale operations are essential to identify potential problems, provide needed data, confirm assumptions, and determine impacts to full-scale melters and off-gas systems from these different feeds. In addition, the reduced-scale melter system must be capable of quickly providing results to operations without the typically high cost of full-scale radioactive operations and to provide an engineering platform in close proximity to local operations staff. The objectives of this computational modeling effort are to produce process conditions like those encountered in the WTP LAW melters and to minimize the volume of radioactive waste necessary for the evaluations. To this end, melter design features are being explored to increase production without significantly increasing surface area or melter-glass volumes or compromising data quality. In support of these objectives, a set of computational fluid dynamic models was developed to provide insight into the flow patterns within these small melters and evaluate design features to increase production without significantly increasing glass inventory. Computed velocities were evaluated at the interface between the cold cap and the molten-glass pool and within the bulk-glass pool. Since melt rate correlates with the velocity underneath the cold cap, this information can be used to select design features that produce the highest gains. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗