Engineering PapersSearch

SEARCH · Engineering Papers

Results for “voltage inference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Optical Arc-Length Sensor For TIG Welding

Proposed subsystem of tungsten/inert-gas (TIG) welding system measures length of welding arc optically. Viewed by video camera, in one of three alternative optical configurations. Length of arc measured instead of inferred from voltage.

Smith, Matthew A.

Preliminary results on the conversion of laser energy into electricity

A preliminary experiment was performed to investigate conversion of 10.6 micron laser energy to electrical energy via a laser-sustained argon plasma. Short-circuit currents of 0.7 A were measured between a thoriated-tungsten emitter and collector electrodes immersed in the laser-sustained argon plasma. Open-circuit voltages of about 1.5 V were inferred from the current-voltage load characteristics. The dominant mechanism of laser energy conversion is uncertain at this time. Much higher output powers appear possible.

Thompson, R. W.

Initial comparison of SSPM ground test results and flight data to NASCAP simulations

The satellite surface potential monitor (SSPM) has been developed for the P78-2 SCATHA (Spacecraft Charging At The High Altitudes) satellite to determine the response of selected spacecraft materials to charged-particle environmental fluxes. Since the monitor infers total surface voltages from a single point on the interior side of insulators, a ground simulation program was undertaken to develop analytical techniques to model the monitors and to obtain an experimental calibration of the relationship between the flight measurement techniques and actual measurements. The experimental testing was conducted using monoenergetic electron beams irradiating samples in the dark. An analytical computer model was developed in the NASCAP (NASA Charging Analyzer Program) code. The analytical model material properties for Kapton that controlled backscatter and secondary yield were adjusted to obtain a single set of values that produced reasonable fits for both voltages and currents. The analytical techniques developed in the ground technology investigation have been applied to space flight conditions. Predictions were compared with limited flight data. The agreement is very good indicating that the technique, and NASCAP, can be used to predict spacecraft material charging behavior. Details of the testing, the analytical modelling technique and flight data comparisons are presented.

Stevens, N. J.

Thrust and efficiency of a self-field MPD thruster

Thrust and efficiency of a quasi-steady multi-MW argon MPD thruster are determined for one-millisecond current pulses. Terminal voltage and impulse bit per pulse are measured for a benchmark thruster geometry on a swinging gate thrust stand in a dielectric vacuum tank, at a background pressure of 0.0001 torr, for a range of argon flow rates and arc currents. The quasi-steady thrust data scale quadratically with arc current, and confirm previous estimates of the electromagnetic and electrothermal components of thrust from magnetic and pressure probe measurements. Thruster efficiency is found to increase monotonically with specific impulse, reaching a value of 25% for 4.5 to 6.0 g/sec at 2000 seconds. Results of further experiments show that the inferred specific impulse for voltage fluctuation onset can be increased to 3000 seconds, and the thrust efficiency to above 30%.

Burton, R. L.

Toward an automated signature recognition toolkit for mission operations

Signature recognition is the problem of identifying an event or events from its time series. The generic problem has numerous applications to science and engineering. At NASA's Johnson Space Center, for example, mission control personnel, using electronic displays and strip chart recorders, monitor telemetry data from three-phase electrical buses on the Space Shuttle and maintain records of device activation and deactivation. Since few electrical devices have sensors to indicate their actual status, changes of state are inferred from characteristic current and voltage fluctuations. Controllers recognize these events both by examining the waveform signatures and by listening to audio channels between ground and crew. Recently the authors have developed a prototype system that identifies major electrical events from the telemetry and displays them on a workstation. Eventually the system will be able to identify accurately the signatures of over fifty distinct events in real time, while contending with noise, intermittent loss of signal, overlapping events, and other complications. This system is just one of many possible signature recognition applications in Mission Control. While much of the technology underlying these applications is the same, each application has unique data characteristics, and every control position has its own interface and performance requirements. There is a need, therefore, for CASE tools that can reduce the time to implement a running signature recognition application from months to weeks or days. This paper describes our work to date and our future plans.

Cleghorn, T.

The voltage threshold for arcing for solar cells in LEO: Flight and ground test results

Ground and flight results of solar cell arcing in low Earth orbit (LEO) conditions are compared and interpreted. It is shown that an apparent voltage threshold for arcing may be produced by a strong power law dependence of arc rate on voltage, combined with a limited observation time. The change in this apparent threshold with plasma density is a reflection of the density dependence of the arc rate. A nearly linear dependence of arc rate on density is inferred from the data. A real voltage threshold for arcing for 2 by 2 cm solar cells may exist however, independent of plasma density, near -230 V relative to the plasma. Here, arc rates may change by more than an order of magnitude for a change of only 30 V in array potential. For 5.9 by 5.9 solar cells, the voltage dependence of the arc rate is steeper, and the data are insufficient to indicate the existence of an arcing increased by an atomic oxygen plasma, as is found in LEO, and by arcing from the backs of welded-through substrates.

Ferguson, D. C.

The voltage threshold for arcing for solar cells in Leo - Flight and ground test results

Ground and flight results of solar cell arcing in low earth orbit (LEO) conditions are compared and interpreted. It is shown that an apparent voltage threshold for arcing may be produced by a storage power law dependence of arc rate on voltage, combined with a limited observation time. The change in this apparent threshold with plasma density is a reflection of the density dependence of the arc rate. A nearly linear dependence of arc rate on density is inferred from the data. A real voltage threshold for arcing for 2 by 2 cm solar cells may exist however, independent of plasma density, near -230 V relative to the plasma. Here, arc rates may change by more than an order of magnitude for a change of only 30 V in array potential. For 5.9 by 5.9 solar cells, the voltage dependence of the arc rate is steeper, and the data are insufficient to indicate the existence of an arcing increased by an atomic oxygen plasma, as is found in LEO, and by arcing from the backs of welded-through substrates.

Ferguson, Dale C.

The contribution of flux transfer events to convection

It is shown from flux transfer event (FTE) occurrence statistics, observed as a function of MLT by the ISEE satellites, that recent 2-dimensional analytic theories of the effects of pulsed Petschek reconnection predict FTEs to contribute between 50 and 200 kV to the total reconnection voltage when the magnetosheath field points southward. The upper limit (200 kV) allows the possibility that FTEs provide all the antisunward transport of open field lines into the tail lobe. This range is compared with the voltages associated with series of FTEs signatures, as inferred from ground-based observations, which are in the range 10-60 kV. We conclude that the contribution could sometimes be made by a series of single, large events; however, the voltage is often likely to be contributed by several FTEs at different MLT.

Lockwood, M.

Fuzzy Control Hardware for Segmented Mirror Phasing Algorithm

This paper presents a possible implementation of a control model developed to phase a system of segmented mirrors, with a PAMELA configuration, using analog fuzzy hardware. Presently, the model is designed for piston control only, but with the foresight that the parameters of tip and tilt will be integrated eventually. The proposed controller uses analog circuits to exhibit a voltage-mode singleton fuzzifier, a mixed-mode inference engine, and a current-mode defuzzifier. The inference engine exhibits multiplication circuits that perform the algebraic product composition through the use of operational transconductance amplifiers rather than the typical min-max circuits. Additionally, the knowledge base, containing exemplar data gained a priori through simulation, interacts via a digital interface.

Roth, Elizabeth

Inductive Measurement of Plasma Jet Electrical Conductivity (MSFC Center Director's discretionary Fund)

Measurement of plasma jet electrical conductivity has utility in the development of explosively driven magnetohydrodynamic (MHD) energy converters as well as magnetic flux compression reaction chambers for nuclear/chemical pulse propulsion and power. Within these types of reactors, the physical parameter of critical importance to underlying MHD processes is the magnetic Reynolds number, the value of which depends upon the product of plasma electrical conductivity and velocity. Therefore, a thorough understanding of MHD phenomena at high magnetic Reynolds number is essential, and methods are needed for the accurate and reliable measurement of electrical conductivity in high-speed plasma jets. It is well known that direct measurements using electrodes suffer from large surface resistance, and an electrodeless technique is desired. To address this need, an inductive probing scheme, originally developed for shock tube studies, has been adapted. In this method, the perturbation of an applied magnetic field by a plasma jet induces a voltage in a search coil, which, in turn, can be used to infer electrical conductivity through the inversion of a Fredholm integral equation of the first kind. A 1-in.-diameter probe using a light-gas gun. Exploratory laboratory experiments were carried out using plasma jets expelled from 15-g shaped charges. Measured conductivities were in the range of 4 kS/m for unseeded octol charges and 26 kS/m for seeded octol charges containing 2-percent potassium carbonate by mass.

Turner, M. W.

Inductive Measurement of Plasma Jet Electrical Conductivity

An inductive probing scheme, originally developed for shock tube studies, has been adapted to measure explosive plasma jet conductivities. In this method, the perturbation of an applied magnetic field by a plasma jet induces a voltage in a search coil, which, in turn, can be used to infer electrical conductivity through the inversion of a Fredholm integral equation of the first kind. A 1-inch diameter probe was designed and constructed, and calibration was accomplished by firing an aluminum slug through the probe using a light-gas gun. Exploratory laboratory experiments were carried out using plasma jets expelled from 15-gram high explosive shaped charges. Measured conductivities were in the range of 3 kS/m for unseeded octol charges and 20 kS/m for seeded octol charges containing 2% potassium carbonate by mass.

Turner, Matthew W.

Environmentally-induced voltage limitations in large space power systems

Large power systems proposed for future space missions imply higher operating voltage requirements which, in turn, will interact with the space plasma environment. The effects of these interactions can only be inferred because of the limited data base of ground simulations, small test samples, and two space flight experiments. This report evaluates floating potentials for a 100 kW power system operating at 300, 500, 750, and 1000 volts in relation to this data base. Of primary concern is the possibility of discharging to space. The implications of such discharges were studied at the 500 volt operational setting. It was found that discharging can shut down the power system if the discharge current exceeds the array short circuit current. Otherwise, a power oscillation can result that ranges from 2 to 20 percent, depending upon the solar array area involved in the discharge. Means of reducing the effect are discussed.

Stevens, N. J.

NEXT Single String Integration Tests in Support of the Double Asteroid Redirection Test Mission

A system integration test has been performed utilizing a prototype model NEXT ion thruster, an engineering model power processing unit, and a laboratory model command and data handling system. The objectives of the test were to: a) verify that the integrated system meets performance requirements, b) demonstrate that the integrated system is functional across the anticipated thermal, power processor, and Xe propellant ranges for the DART mission, and to c) evaluate fault detection and operation of the command and data handling system. Measurements made during this test included: thruster performance, PPU input voltages, PPU electrical and thermal telemetry, software states, and fault flags. Additionally, a far-field electrostatic probe diagnostic was used to infer relative changes in the thrust vector across the various propellant flow splits. This manuscript presents the results of these tests, which include integrated ion propulsion system demonstrations of performance, details on the execution of DART flight algorithms, and software fault handling.

Thomas, Robert E.

NEXT Single String Integration Tests in Support of the Double Asteroid Redirection Test Mission

A system integration test has been performed utilizing a prototype model NEXT ion thruster, an engineering model power processing unit, and a laboratory model command and data handling system. The objectives of the test were to: a) verify that the integrated system meets performance requirements, b) demonstrate that the integrated system is functional across the anticipated thermal, power processor, and Xe propellant ranges for the DART mission, and to c) evaluate fault detection and operation of the command and data handling system. Measurements made during this test included: thruster performance, PPU input voltages, PPU electrical and thermal telemetry, software states, and fault flags. Additionally, a far-field electrostatic probe diagnostic was used to infer relative changes in the thrust vector across the various propellant flow splits. This manuscript presents the results of these tests, which include integrated ion propulsion system demonstrations of performance, details on the execution of DART flight algorithms, and software fault handling.

Thomas, Robert

Measurements of Siple transmitter signals on the DE 1 satellite - Wave normal direction and antenna effective length

A new experimental technique is developed to simultaneously measure the wave propagation direction and the effective length of a small (L value much smaller than wavelength) electric dipole antenna on a spin-stabilized satellite in the magnetosphere. The technique relies on the near simultaneous measurement of single components of the electric and magnetic fields of a coherent VLF signal injected into the medium from a ground-based source. The spin fading characteristics of the signal received by the electric dipole and the magnetic loop antenna permit the measurement of the wave normal direction assuming whistler-mode propagation. In-situ and remote measurements of the local cold plasma density are used to determine the refractive index. The wave electric field is then inferred from the wave magnetic field as measured on the loop antenna, the refractive index and the direction of propagation. Comparing this electric field with the measured voltage across the dipole antenna leads to the determination of the effective length of the receiving electric dipole. The technique is applied to data from the Dynamics Explorer 1 satellite observations of whistler mode signals injected into the magnetosphere from the Siple, Antarctica, VLF transmitter. In one case, with the measured background cold plasma density being 15 el/cu cm, the effective length of the 200 m-long electric dipole antenna is found to be 222 + or - 56 m, i.e., about twice the conventional value.

Sonwalker, V. S.

Investigation of a repetitive pulsed electrothermal thruster

A pulsed electrothermal (PET) thruster with 1000:1 ratio nozzle is tested in a repetitive mode on water propellant. The thruster is driven by a 60J pulse forming network at repetition rates up to 10 Hz (600W). The pulse forming network has a .31 ohm impedance, well matched to the capillary discharge resistance of .40 ohm, and is directly coupled to the thruster electrodes without a switch. The discharge is initiated by high voltage breakdown, typically at 2500V, through the water vapor in the interelectrode gap. Water is injected as a jet through a .37 mm orifice on the thruster axis. Thruster voltage, current and impulse bit are recorded for several seconds at various power supply currents. Thruster to power ratio is typically T/P = .07 N/kW. Tank background pressure precludes direct measurement of exhaust velocity which is inferred from calculated pressure and temperature in the discharge to be about 14 km/sec. Efficiency, based on this velocity and measured T/P is .54 + or - .07. Thruster ablation is zero at the throat and becomes measurable further upstream, indicating that radiative ablation is occurring late in the pulse.

Burton, R. L.

Convection of tin in a Bridgman system. I - Flow characterization by effective diffusivity measurements

An electrochemical titration method was used to investigate the dynamic states in a cylindrical layer of convecting tin. The liquid tin was contained in a cell, with curved boundaries made of quartz and flat boundaries made of a solid state electrolyte - yttria-stabilized zirconia (YSZ). The electrolyte acted as a window through which a trace amount of oxygen could be pumped in or out by the application of a constant voltage. The concentration at the YSZ interface was monitored by operating the electrochemical cell in the galvanic mode. Experimentally determined effective diffusivities of oxygen were compared with the molecular diffusivity. Dynamic states in the convective flow were thus inferred. Temperature measurements were simultaneously made in order to identify the onset of oscillations from a steady convective regime. The experiments were conducted for two different aspect ratios for various imposed temperature gradients and two different orientations with respect to gravity. Transcritical states were identified and comparison to two-dimensional numerical models were made.

Sears, B.

Interpretation of F-106B in-flight lightning signatures

Various characteristics of the electromagnetic data obtained on a NASA F-106B aircraft during direct lightning strikes are presented. Time scales of interest range from 10 ns to 400 microsecond. The following topics are discussed: (1) Lightning current, I, measured directly versus I obtained from computer integration of measured I-dot; (2) A method of compensation for the low frequency cutoff of the current transformer used to measure I; (3) Properties of fast pulses observed in the lightning time-derivative waveforms; (4) The characteristic D-dot signature of the F-106B aircraft; (5) An RC-discharge interpretation for some lightning waveforms; (6) A method for inferring the locations of lightning channel attachment points on the aircraft by using B-dot data; (7) Simple, approximate relationships between D-dot and I-dot and between B and I; and (8) Estimates of energy, charge, voltage, and resistance for a particular lightning event.

Trost, T. F.