Here, a novel method, the Gaussian Integral Method (GIM), is presented for calculating void fractions in Computational Fluid Dynamics–Discrete Element Method (CFD-DEM) simulations. GIM is versatile and applicable to various grid types, including structured and unstructured polyhedral meshes, without requiring special boundary treatments. An optimization technique is introduced to make GIM independent of grid resolution and type. The method is validated against experimental data from a fluidized bed, demonstrating that GIM produces realistic simulations closely resembling experimental observations. Additionally, unstructured polyhedral grids using GIM outperform structured grids of equivalent resolution, yielding results more aligned with experimental data. The gradient of the void fraction is computed in the CFD solver and utilized in the DEM solver for precise estimation at particle locations. Overall, GIM provides an effective solution for void fraction calculations in particulate media simulations with complex geometries, enhancing the accuracy and applicability of CFD-DEM simulations for industrial processes.
Void fraction /local density/ measurements are made in an axisymmetric cavitation flow inside of a venturi tube operating with mercury, using a gamma-ray densitometer
Here, this study presents, to the authors knowledge, the first experimental investigation on the void fraction and flow patterns in two-phase flows through a diamond-type Triply Periodic Minimal Surface (TPMS) lattice. An additively manufactured TPMS structure was tested under upward co-current flow of a water/nitrogen mixture. Superficial velocities varied for a total of 42 test conditions (gas: 0.01–2.4 m/s; liquid: 0.01–2.4 m/s; mass flux: 20–2370 kg/m 2 ·s). High-speed video and X-ray imaging enabled time-averaged void fraction measurements and identified six distinct flow regimes which were used to develop a flow pattern map. Comparison of the void fraction data with correlations from literature demonstrated the Rouhani and Axelsson (1970) [49] correlation modified by Steiner (1993) [52] provided the best agreement, which was improved with empirically fit coefficients. This approach predicted the void fraction with errors < ±20% for 64% of the data, with a mean absolute percent deviation (MAPD) of 23%. The measured frictional pressure drop was compared to correlations from literature which captured the observed trends but did not provide good accuracy. The best agreement was found after optimizing the empirical coefficients of the Muller-Steinhagen & Heck (1986) [56] correlation; this approach captured 33% of the data within ±20% with a MAPD of 46% over the full range and captured 71% of the data within ±20% a MAPD of 13.3% at mass fluxes >1100 kg/m 2 -s. These results provide foundational insight into TPMS two-phase flow behavior and inform modeling and design of advanced heat exchange components incorporating TPMS geometries.
We used a permanent-magnet MRI system to estimate the integral and spatially- and/or temporally-resolved void-fraction distributions and flow patterns in gas-liquid two-phase flows. Air was introduced at the bottom of the stagnant liquid column using an accurate and programmable syringe pump. Air flow rates were varied between 1 and 200 ml/min. The cylindrical non-conducting test tube in which two-phase flow was measured was placed in a 2.67 kGauss MRI with MRT spectrometer/imager. Roughly linear relationship has been obtained for the integral void-fraction, obtained by volume-averaging of the spatially-resolved signals, and the air flow rate in upward direction. The time-averaged spatially-resolved void fraction has also been obtained for the quasi-steady flow of air in a stagnant liquid column. No great accuracy is claimed as this was an exploratory proof-of-concept type of experiment. Preliminary results show that MRI a non-invasive and non-intrusive experimental technique can indeed provide a wealth of different qualitative and quantitative data and is especially well suited for averaged transport processes in adiabatic and diabatic multi-phase and/or multi-component flows.
One-shot gamma attenuation technique for measuring void fractions in two-phase flow
Void fraction measurements in cavitating venturi tube with liquid metal flow
Heat addition in the empirical correlation of void fractions for steam-water flow
Two-phase flow, using hot wire anemometer technique for detecting void distribution and phase velocities
Gamma-ray densitometer technique for precise measurement of local or mean density in axially symmetric two phase flow with attention to cavitating mercury in venturi
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The effects of porosity on damage incurred by low-velocity impact are investigated. Specimens of graphite/epoxy composite were fabricated with various volume fractions of voids. The void fraction was independently determined using optical examination and acid resin digestion methods. Thermal diffusivity and ultrasonic attenuation were measured, and these results were related to the void volume fraction. The relationship between diffusivity and fiber volume fraction was also considered. The slope of the ultrasonic attenuation coefficient was found to increase linearly with void content, and the diffusivity decreased linearly with void volume fraction, after compensation for an approximately linear dependence on the fiber volume fraction.
Accurate prediction of pebble packing structure is important for pebble bed reactors because the spatial distribution of void fraction directly affects coolant flow, pressure drop, heat transfer, and neutronic behavior. However, experimentally validated DEM studies that directly evaluate local void-fraction structure in reactor-relevant pebble beds remain limited. In this work, the pebble bed experiment conducted at Missouri University of Science and Technology is simulated using the graphics processing unit (GPU)-based discrete element method (DEM) code Chrono::GPU. The study focuses on evaluating the ability of Chrono::GPU to reproduce the packing arrangement and void-fraction distribution of a randomly packed spherical pebble bed. The DEM results are first verified against established radial void-fraction correlations, including the Mueller and Vortmeyer-Schuster models, to assess the predicted bulk porosity, near-wall behavior, and oscillatory packing structure. The simulation is then verified against reference DEM data and validated against gamma-ray computed tomography (CT) experimental data at three axial locations. The Chrono::GPU results reproduce the main features of the experimental packing, including the high void fraction near the wall, the first near-wall trough, and the damped oscillatory radial profile caused by wall-induced ordering. Quantitative comparison with DEM data and the CT-based radial profiles shows good agreement, with mean absolute errors on the order of 0.07 and root-mean-square errors below 0.09 for the averaged profiles. These results demonstrate that Chrono::GPU can accurately capture the void-fraction structure of spherical pebble beds and provides a reliable DEM framework for future pebble bed reactor packing, recycling, and thermal-hydraulic studies.
The present investigation reports a study of bubble generation under reduced gravity conditions, using both a co-flow and a cross-flow configuration. This study may be used in the conceptual design of a space-based thermal management system. Ensuing two-phase flow void fraction can be accurately monitored using a single nozzle gas injection system within a continuous liquid flow conduit, as utilized in the present investigation. Accurate monitoring of void fraction leads to precise control of heat and mass transfer coefficients related to a thermal management system; hence providing an efficient and highly effective means of removing heat aboard spacecraft or space stations. Our experiments are performed in parabolic flight aboard the modified DC-9 Reduced Gravity Research Aircraft at NASA Lewis Research Center, using an air-water system. For the purpose of bubble dispersion in a flowing liquid, we use both a co-flow and a cross-flow configuration. In the co-flow geometry, air is introduced through a nozzle in the same direction with the liquid flow. On the other hand, in the cross-flow configuration, air is injected perpendicular to the direction of water flow, via a nozzle protruding inside the two-phase flow conduit. Three different flow conduit (pipe) diameters are used, namely, 1.27 cm, 1.9 cm and 2.54 cm. Two different ratios of nozzle to pipe diameter (D(sub N))sup * are considered, namely (D(sub N))sup * = 0.1 and 0.2, while superficial liquid velocities are varied from 8 to 70 cm/s depending on flow conduit diameter. It is experimentally observed that by holding all other flow conditions and geometry constant, generated bubbles decrease in size with increase in superficial liquid velocity. Detached bubble diameter is shown to increase with air injection nozzle diameter. Likewise, generated bubbles grow in size with increasing pipe diameter. Along the same lines, it is shown that bubble frequency of formation increases and hence the time to detachment of a forming bubble decreases, as the superficial liquid velocity is in-creased. Furthermore, it is shown that the void fraction of the resulting two-phase flow increases with volumetric gas flow rate Q(sub d), pipe diameter and gas injection nozzle diameter, while they decrease with surrounding liquid flow. The important role played by flowing liquid in detaching bubbles in a reduced gravity environment is thus emphasized. We observe that the void fraction can be accurately controlled by using single nozzle gas injection, rather than by employing multiple port injection, since the later system gives rise to unpredictable coalescence of adjacent bubbles. It is of interest to note that empirical bubble size and corresponding void fraction are somewhat smaller for the co-flow geometry than the cross-flow configuration at similar flow conditions with similar pipe and nozzle diameters. In order to supplement the empirical data, a theoretical model is employed to study single bubble generation in the dynamic (Q(sub d) = 1 - 1000 cu cm/s) and bubbly flow regime within the framework of the co-flow configuration. This theoretical model is based on an overall force balance acting on the bubble during the two stages of generation, namely the expansion and the detachment stage. Two sets of forces, one aiding and the other inhibiting bubble detachment are identified. Under conditions of reduced gravity, gas momentum flux enhances, while the surface tension force at the air injection nozzle tip inhibits bubble detachment. In parallel, liquid drag and inertia can act as both attaching and detaching forces, depending on the relative velocity of the bubble with respect to the surrounding liquid. Predictions of the theoretical model compare well with our experimental results. However, at higher superficial liquid velocities, as the bubble loses its spherical form, empirical bubble size no longer matches the theoretical predictions. In summary, we have developed a combined experimental and theoretical work, which describes the complex process of bubble generation and resulting two-phase flow in a microgravity environment. Results of the present study can be used in a wide range of space-based applications, such as thermal energy and power generation, propulsion, cryogenic storage and long duration life support systems, necessary for programs such as NASA's Human Exploration for the Development of Space (HEDS).
Based on the experiments carried out over the past decade at microgravity conditions, an overview of our current knowledge of bubbly and slug flows is presented. The transition from bubble to slug flow, the void fraction and the pressure drop are discussed from the data collected in the literature. The transition from bubble to slug flow may be predicted by introducing a critical void fraction that depends on the fluid properties and the pipe diameter; however, the role of coalescence which controls this transition is not clearly understood. The void fraction may be accurately calculated using a drift-flux model. It is shown from local measurements that the drift of the gas with respect to the mixture is due to non-uniform radial distribution of void fraction. The pressure drop happens to be controlled by the liquid flow for bubbly flow whereas for slug flow the experimental results show that pressure drops is larger than expected. From this study, the guidelines for future research in microgravity are given.
This paper presents test results of an experimental study of low power operation in a loop heat pipe. The main objective was to demonstrate how changes in the vapor void fraction inside the evaporator core would affect the loop behavior, The fluid inventory and the relative tilt between the evaporator and the compensation chamber were varied so as to create different vapor void fractions in the evaporator core. The effect on the loop start-up, operating temperature, and capillary limit was investigated. Test results indicate that the vapor void fraction inside the evaporator core is the single most important factor in determining the loop operation at low powers.