Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “virtual imaging trials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

AAPM Truth‐based CT (TrueCT) reconstruction grand challenge

Background: This Special Report summarizes the 2022, AAPM grand challenge on Truth-based CT image reconstruction. Purpose: To provide an objective framework for evaluating CT reconstruction methods using virtual imaging resources consisting of a library of simulated CT projection images of a population of human models with various diseases. Methods: Two hundred unique anthropomorphic, computational models were created with varied diseases consisting of 67 emphysema, 67 lung lesions, and 66 liver lesions. The organs were modeled based on clinical CT images of real patients. The emphysematous regions were modeled using segmentations from patient CT cases in the COPDGene Phase I dataset. For the lung and liver lesion cases, 1–6 malignant lesions were created and inserted into the human models, with lesion diameters ranging from 5.6 to 21.9 mm for lung lesions and 3.9 to 14.9 mm for liver lesions. The contrast defined between the liver lesions and liver parenchyma was 82 ± 12 HU, ranging from 50 to 110 HU. Similarly, the contrast between the lung lesions and the lung parenchyma was defined as 781 ± 11 HU, ranging from 725 to 805 HU. For the emphysematous regions, the defined HU values were −950 ± 17 HU ranging from −918 to −979 HU. The developed human models were imaged with a validated CT simulator. The resulting CT sinograms were shared with the participants. The participants reconstructed CT images from the sinograms and sent back their reconstructed images. Further, the reconstructed images were then scored by comparing the results against the corresponding ground truth values. The scores included both task-generic (root mean square error [RMSE] and structural similarity matrix [SSIM]), and task-specific (detectability index [d’] and lesion volume accuracy) metrics. For the cases with multiple lesions, the measured metric was averaged across all the lesions. To combine the metrics with each other, each metric was normalized to a range of 0 to 1 per disease type, with “0” and “1” being the worst and best measured values across all cases of the disease type for all received reconstructions. Results: The True-CT challenge attracted 52 participants, out of which 5 successfully completed the challenge and submitted the requested 200 reconstructions. Across all participants and disease types, SSIM absolute values ranged from 0.22 to 0.90, RMSE from 77.6 to 490.5 HU, d’ from 0.1 to 64.6, and volume accuracy ranged from 1.2 to 753.1 mm3. The overall scores demonstrated that participant “A” had the best performance in all categories, except for the metrics of d’ for lung lesions and RMSE for liver lesions. Participant “A” had an average normalized score of 0.41 ± 0.22, 0.48 ± 0.32, and 0.42 ± 0.33 for the emphysema, lung lesion, and liver lesion cases, respectively. Conclusions: The True-CT challenge successfully enabled objective assessment of CT reconstructions with the unique advantage of access to a diverse population of diseased human models with known ground truth. This study highlights the significant potential of virtual imaging trials in objective assessment of medical imaging technologies.

60 APPLIED LIFE SCIENCES↗

Black-box optimization of CT acquisition and reconstruction parameters: a reinforcement learning approach

Protocol optimization is critical in Computed Tomography (CT) for achieving desired diagnostic image quality while minimizing radiation dose. Due to the inter-effect of influencing CT parameters, traditional optimization methods rely on the testing of exhaustive combinations of these parameters. This poses a notable limitation due to the impracticality of exhaustive parameter testing. This study introduces a novel methodology leveraging Virtual Imaging Trials (VITs) and reinforcement learning to more efficiently optimize CT protocols. Computational phantoms with liver lesions were imaged using a validated CT simulator and reconstructed with a novel CT reconstruction Toolkit. The optimization parameter space included tube voltage, tube current, reconstruction kernel, slice thickness, and pixel size. The optimization process was done using a Proximal Policy Optimization (PPO) agent which was trained to maximize the Detectability Index (d’) of the liver lesion for each reconstructed image. Results showed that our reinforcement learning approach found the absolute maximum d’ across the test cases while requiring 79.7% fewer steps compared to an exhaustive search, demonstrating both accuracy and computational efficiency, offering a efficient and robust framework for CT protocol optimization. The flexibility of the proposed technique allows for use of varying image quality metrics as the objective metric to maximize for. Our findings highlight the advantages of combining VIT and reinforcement learning for CT protocol management.

Fenwick, David [Duke University Medical Center]↗

In situ tumor model for longitudinal in silico imaging trials

Abstract Objective.In this article, we introduce a computational model for simulating the growth of breast cancer lesions accounting for the stiffness of surrounding anatomical structures.Approach.In our model, ligaments are classified as the most rigid structures while the softer parts of the breast are occupied by fat and glandular tissues As a result of these variations in tissue elasticity, the rapidly proliferating tumor cells are met with differential resistance. It is found that these cells are likely to circumvent stiffer terrains such as ligaments, instead electing to proliferate preferentially within the more yielding confines of the breast’s soft topography. By manipulating the interstitial tumor pressure in direct proportion to the elastic constants of the tissues surrounding the tumor, this model thus creates the potential for realizing a database of unique lesion morphology sculpted by the distinctive topography of each local anatomical infrastructure. We modeled the growth of simulated lesions within volumes extracted from fatty breast models, developed by Graffet alwith a resolution of 50μm generated with the open-source and readily available Virtual Imaging Clinical Trials for Regulatory Evaluation (VICTRE) imaging pipeline. To visualize and validate the realism of the lesion models, we leveraged the imaging component of the VICTRE pipeline, which replicates the siemens mammomat inspiration mammography system in a digital format. This system was instrumental in generating digital mammogram (DM) images for each breast model containing the simulated lesions.Results.By utilizing the DM images, we were able to effectively illustrate the imaging characteristics of the lesions as they integrated with the anatomical backgrounds. Our research also involved a reader study that compared 25 simulated DM regions of interest (ROIs) with inserted lesions from our models with DM ROIs from the DDSM dataset containing real manifestations of breast cancer. In general the simulation time for the lesions was approximately 2.5 hours, but it varied depending on the lesion’s local environment.Significance.The lesion growth model will facilitate and enhance longitudinal in silico trials investigating the progression of breast cancer.

Engineering↗

A VR-based volumetric medical image segmentation and visualization system with natural human interaction

Volume rendering produces informative two-dimensional (2D) images from a 3-dimensional (3D) volume. It highlights the region of interest and facilitates a good comprehension of the entire data set. However, volume rendering faces a few challenges. First, a high-dimensional transfer function is usually required to differentiate the target from its neighboring objects with subtle variance. Unfortunately, designing such a transfer function is a strenuously trial-and-error process. Second, manipulating/visualizing a 3D volume with a traditional 2D input/output device suffers dimensional limitations. To address all the challenges, we design NUI-VR 2 , a natural user interface-enabled volume rendering system in the virtual reality space. NUI-VR 2 marries volume rendering and interactive image segmentation. It transforms the original volume into a probability map with image segmentation. A simple linear transfer function will highlight the target well in the probability map. More importantly, we set the entire image segmentation and volume rendering pipeline in an immersive virtual reality environment with a natural user interface. NUI-VR 2 eliminates the dimensional limitations in manipulating and perceiving 3D volumes and dramatically improves the user experience.

42 ENGINEERING↗