Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vessel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Vessel Rupture Thresholds for Vessel–Bubble Interactions Using an Earthworm Vasculature Model

Intravenous microbubble oscillation in the presence of ultrasound has the potential to yield a wide range of therapeutic benefits. However, the likelihood of vessel damage caused by mechanical effects has not been quantified as a function of the numerous important parameters in therapeutic ultrasound procedures. In this study, we examined the effects of microbubbles injected into the vasculature of the earthworm. It was found that the elastic properties of earthworm blood vessels are similar to those of arteries in older humans, and that earthworms are well suited to the large number of experiments necessary to investigate safety of procedures involving microbubble oscillation in sonicated vessels. Microbubbles were infused into earthworm vessels, and the rupture time during sonication was recorded as a function of ultrasound frequency, pulse repetition frequency and acoustic pressure. A modified mechanical index (MMI) was defined that successfully captured the trends in rupture probability and rupture time for the different parameter values, creating a database of vessel rupture thresholds. In the absence of bubbles, the product of MMI squared and rupture time was approximately constant, indicating a possible radiation-force effect. Here, the MMI was an effective correlating parameter in the presence of bubbles, though the mathematical dependence is not yet apparent. The results of the study are expected to be valuable in designing more refined studies in vertebrate models, as well as informing computational models.

59 BASIC BIOLOGICAL SCIENCES↗

Strain Gauge Diagnostic Development for use in Vessel Health Monitoring for Hydro-shots

Six-foot vessels are a crucial component to protecting high fidelity equipment at DARHT. Analysis shows these vessels have a limited life span (~10 shots) due to fatigue, ratcheting, and damage accumulation. Vessel health monitoring and diagnostics can help inform decision on a vessel’s fitness for service. Strain gauges are an easy and effective sensor for use in vessel health monitoring. In early March, J-2 executed a qualification shot, uniform blast loading with minimal fragments, with bi-axial strain gauges fielded at four locations around vessel. Several damage features were extracted from the data, and frequency content helps to validate computer modelling of the vessel response. Permanent plastic strain at each location was significant with location one having the most strain at the end state, with 230 micro-strain. However, residual pressure in the vessel could be a major factor in this strain. PEEQ is a measure of total plastic equivalent strain accumulation. The equivalent strain at location one exceeded the plastic strain limit four times and accumulated the most PEEQ with 2036 micro-strain. As expected, this qualification shot did contribute to damage in the vessel, and should be considered in its fitness for service, but not critical enough to pull it from service. Frequency content also gave valuable information on the modal response of the vessel and contributes to the understanding of how the vessel responds to the initial blast load with an expected lower frequency membrane/breathing mode and transitioning to higher frequency bending modes in the vessel wall.

42 ENGINEERING↗

Effects of vessel traffic and ocean noise on gray whale stress hormones

Human use of marinescapes is rapidly increasing, especially in populated nearshore regions where recreational vessel traffic can be dense. Marine animals can have a physiological response to such elevated human activity that can impact individual health and population dynamics. To understand the physiological impacts of vessel traffic on baleen whales, we investigated the adrenal stress response of gray whales (Eschrichtius robustus) to variable vessel traffic levels through an assessment of fecal glucocorticoid metabolite (fGC) concentrations. This analysis was conducted at the individual level, at multiple temporal scales (1–7 days), and accounted for factors that may confound fGC: sex, age, nutritional status, and reproductive state. Data were collected in Oregon, USA, from June to October of 2016–2018. Results indicate significant correlations between fGC, month, and vessel counts from the day prior to fecal sample collection. Furthermore, we show a significant positive correlation between vessel traffic and underwater ambient noise levels, which indicates that noise produced by vessel traffic may be a causal factor for the increased fGC. This study increases knowledge of gray whale physiological response to vessel traffic and may inform management decisions regarding regulations of vessel traffic activities and thresholds near critical whale habitats.

59 BASIC BIOLOGICAL SCIENCES↗

Initial Testing of an In Situ Load Retention Aging Vessel

A thermal aging vessel instrumented with load cells was fabricated. The primary function of the vessel is to continuously monitor the in situ load retention of up to three compressed polymer coupons undergoing thermally accelerated aging under nitrogen. A secondary function is to enable gas sampling of the vessel headspace during thermal aging. Heating of the vessel is achieved using a custom heater jacket. To improve upon our conventional aging study methods which require periodic interruption of aging to perform load testing in an Instron machine at room temperature, this technology aims to automate/facilitate data acquisition/analysis, improve data quality, and enable uninterrupted compression of the polymer which represents the service condition. As an example case to assess functionality of the in situ vessel, the load retention of a siloxane elastomer material additively manufactured by direct-ink-writing (DIW) was measured at three different isothermal aging temperatures for ~1 month. Initial compression of the coupons while near the aging temperature was achieved by temporarily opening the heated vessel to access the interior chamber and manually tightening four nuts to drive the heated compression plate down onto the heated coupons. Initial testing demonstrated achievement of the primary load retention monitoring function. Unfortunately, the vessel leaked which prevented gas sampling; an active purge was used to maintain a nitrogen atmosphere. Welded or otherwise sealed joints, which could be implemented in a future design, would likely eliminate leak paths. To apply time-temperature superposition (TTS), a technique used to provide long-term prediction of the load retention from short-term isothermal data, the load retention needed to be calculated relative to the load at an estimated “equilibrium” time, after most of the transient viscoelastic physical relaxation occurred. The peak load immediately after compression could not be used as the load retention basis for two reasons: (1) age-related changes must be isolated from non-age-related physical relaxation before applying TTS and (2) the manual mechanism used to compress the specimens at the aging temperature was neither smooth nor repeatable which affected the peak load value. To better understand the effect of the mode of initial compression on the measured load, and possibly better estimate “equilibrium” physical relaxation times, systematic stress relaxation experiments were performed using an Instron machine with a thermal chamber. At a given temperature, the DIW polymer was compressed to a fixed strain in either a stepped or continuous manner at two different rates, then held at that strain for 24 hrs. The results indicated that, at a given temperature, the different stress relaxation curves appeared to converge to the same curve at some “equilibrium” time when the non-age-related physical relaxation was mostly complete. Though this observation suggests that the discontinuous manual compression employed by the vessel is feasible, a compression mechanism that is rapid, smooth, and repeatable would enhance its use.

36 MATERIALS SCIENCE↗

A Novel Design for Improving the Control on the Stainless-Steel Vessel Welding Process for Superconducting Magnets

Stainless steel vessels see widespread use in superconducting magnets for particle accelerator applications. Their function varies in different magnet designs: they always provide the necessary liquid helium containment, but in some cases are also used to provide azimuthal prestress and can also be welded to the magnet end plate to provide additional longitudinal stiffness. A magnet designed with the bladder and key technology does not rely on the structural role of the vessel. They are structurally supported using azimuthally prestressed aluminum shells, and the longitudinal constraint by rods. In this case, the magnet designer would generally like to minimize the interaction between the magnet and the stainless-steel vessel and to minimize the coil stress variation due to the vessel. The stress state in the vessel and in the coil is a function of the circumferential interference, defined as the vessel azimuthal length minus the magnet circumference. The vessel and the magnet azimuthal length machining tolerances are relatively large resulting in significant stress variations in the superconducting coils. Here in this paper we introduce an interference-control shim, which can significantly limit the stress variation of the coils for a given variation of the interference. The effectiveness of the interference-control shim is evaluated numerically on the MQXF, the low-β quadrupole for the High Luminosity LHC.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Automated remote sensing tools to counter illicit maritime activity: vessel detection, bathymetry and topography from WorldView imagery

Illicit maritime activity, such as piracy and smuggling, is a global issue that often occurs in areas where interdiction authorities are sparse, ground-based monitoring technologies like radar lack range and coverage, and dark vessels abound. Our objective was to assess vessel congregation patterns, identify likely beaching areas based on terrain maps, and use them to narrow the search for potential smuggling transfer and overland routes in a specific region along the Puntland coast of Somalia. To accomplish this goal, we developed automated protocols applied to WorldView satellite imagery for (1) vessel detection and size classification, (2) shallow-water bathymetric characterization, and (3) coastal topography mapping. Utilizing a single sensor for vessel detection and topographic and bathymetric extraction at high spatial resolution and at a high re-visit rate provides a simplification to near-shore characterization for monitoring purposes. The extracted topography and bathymetry are then presented as a single, comprehensive perspective of a coastal region. The vessel-detection algorithm identified all vessels larger than approximately 15 metres in length (35 of 35), but misidentified six artefacts (i.e. false positives), resulting in an overall accuracy of 85%. The combined vessel and terrain maps facilitated the identification of a potential beaching and overland transportation route location.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Salt Vessel-Sample Generator Interface

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches for interfacing relevant unit operations with salt analysis to improve the timeliness and accuracy of sampling-based accountancy measurements. One technology under development is a vacuum sampler loop module. In this system, molten salt is drawn from a process vessel through a heated sampling line and into a charge vessel. Next, one or more samples are split from the volume in the charge vessel and the remaining salt is returned to the process. The vacuum sampler loop module is being developed to interface with other sample processing and analysis modules to enable rapid at-line sample characterization. The main purpose of the vacuum sampling loop module is to enable the collection of samples that are more representative of the bulk salt by replacing traditional point samplers (i.e., dip probes) with a sampling approach that captures a larger cross section of salt. Additionally, the vacuum sampling approach eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. Two methods of interfacing the vacuum sampling loop with a precision pneumatic sample generator were investigated in FY21. This report covers the testing of fluidic coupling between the two modules. Two iterations of the fluidically coupled modules were tested. The first iteration system coupled the two modules using a freeze valve to seal the vacuum sampler during filling and to control flow into the pneumatic sample generator. While this integrated system functioned as intended, some changes were implemented to make the system more robust and better suited to remote deployment. Specifically, the system was made to be more modular and active control of the vacuum filling operation was replaced with a passive control mechanism. For passive filling, the salt charge vessel was vented to a small gas tank that was at negative pressure, causing salt to be drawn into the vessel until the force of the fluid head was in equilibrium with the gas pressure. The passive control system performed well and will be used in future iterations. Another change in the second system was a newly configured pneumatic sample generator in which sample ejection occurred through a hole in the reservoir’s stainless-steel side wall instead of through a non-wetted sapphire orifice on the bottom. This alternate configuration may be better suited for near-process deployment because it enables on-line orifice maintenance and an orifice bypass drain back to the process. A third change in the second iteration system was the transition to a two-chamber charge vessel which split off a fraction of the sampled salt as a liquid aliquot. The goal was to create a buffer mechanism that would allow reproducible aliquoting of samples, independently of variability in the charge vessel fill height. While the two-chamber design was functional, the sample size reproducibility was below target values. To improve reproducibility and overcome many of the impediments to remote deployment of the vacuum sampling loop module, separate work was conducted to replace the two-chamber liquid aliquoting mechanism with aliquoting into single-use sample tubes. Solid salt transfer in the sample tubes will replace fluidic coupling for integrating the vacuum sampler with downstream modules. Because the proposed operations can all be executed with simple overhead actuation mechanisms or other existing hot-cell technology, there will be no need for large investments in novel hot cell sample handling technologies using this alternate approach. As such, near-term deployment of the vacuum sampling technology will be achievable. This new approach for automated coupling of sample tubes with down-stream modules is covered in a separate FY21 report, and a remotely operated version of the vacuum sampler loop module with the tube aliquoting feature is planned for FY22.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Multiscale Modeling Approach to Cryocompressed Hydrogen Storage Pressure Vessels – Part II: Constitutive Modeling and Finite Element Analysis

Subjected to thermomechanical cycling, composite cryogenic hydrogen (H2) storage pressure vessels experience high stresses in the carbon fiber (CF)/epoxy overwrap which can lead to vessel failure due to a combination of degradation mechanisms such as matrix cracking, fiber/matrix debonding, delamination, and fiber rupture. The present paper is the second part of a set of two articles on this subject that addresses analysis and design of these pressure vessels. Predictive finite element (FE) modeling capabilities have been used to support a material acceptance process that aims at providing guidance to evaluate specialty resins, vessel liner options, and CF composites through thermomechanical testing. We have applied a multiscale modeling approach recently developed (B.N. Nguyen et al., International Journal of Hydrogen Energy, 2019, https://doi.org/10.1016/j.ijhydene.2019.09.200) to perform three-dimensional (3D) FE analysis and design of a cryo-compressed H2 storage pressure vessel for its operation in a large temperature range from room to cryogenic temperatures. The developed approach termed the micro-meso-macro approach determines the laminar stresses in different layers of the vessel in addition to constituent (i.e., fiber and matrix) stresses that are important to the design of the composite overwrap for its layup and material combination to reduce the risk of vessel failure.

Nguyen, Ba Nghiep↗

A Novel Design for Improving the Control on the Stainless-Steel Vessel Welding Process for Superconducting Magnets

Stainless steel vessels see widespread use in superconducting magnets for particle accelerator applications. Their function varies in different magnet designs: they always provide the necessary liquid helium containment, but in some cases are also used to provide azimuthal prestress and can also be welded to the magnet end plate to provide additional longitudinal stiffness. A magnet designed with the bladder and key technology does not rely on the structural role of the vessel. They are structurally supported using azimuthally prestressed aluminum shells, and the longitudinal constraint by rods. In this case, the magnet designer would generally like to minimize the interaction between the magnet and the stainless-steel vessel and to minimize the coil stress variation due to the vessel. The stress state in the vessel and in the coil is a function of the circumferential interference, defined as the vessel azimuthal length minus the magnet circumference. The vessel and the magnet azimuthal length machining tolerances are relatively large resulting in significant stress variations in the superconducting coils. In this paper we introduce an interference control shim, which can significantly limit the stress variation of the coils for a given variation of the interference. The effectiveness of the interference-control shim is evaluated numerically on the MQXF, the low-β quadrupole for the High Luminosity LHC.

43 PARTICLE ACCELERATORS↗

Boron injection system for controlling a nuclear reaction by delivering boron into a containment vessel

A nuclear power system includes a reactor vessel that includes a reactor core mounted within a volume of the reactor vessel. The reactor core includes one or more nuclear fuel assemblies configured to generate a nuclear fission reaction. The nuclear power system further includes a containment vessel sized to enclose the reactor vessel such that an open volume is defined between the containment vessel and the reactor vessel. A boron injection system is positioned in the open volume of the containment vessel and includes an amount of boron sufficient to stop the nuclear fission reaction or maintain the nuclear fission reaction at a sub-critical state. The boron injection system is positioned to deliver the amount of boron into the open volume.

Linik, Larry↗

Experimental and numerical studies of seismic fluid-structure interaction in a base-supported cylindrical vessel

Seismic design and qualification of advanced reactors will rely heavily on the use of verified and validated numerical models capable of capturing the interaction of the vessel, its contained fluid, and the internal equipment: fluid-structure interaction (FSI) analysis. Analytical solutions can be used for preliminary sizing and design of such vessels but their application is limited to simple geometries and boundary conditions, and small amplitude, translational (and rotational) inputs. To validate numerical models for seismic FSI analysis in finite element codes, a comprehensive set of experiments was performed on a liquid-filled cylindrical vessel, using a 6 degree-of-freedom earthquake simulator. Results in terms of sloshing frequency, damping ratio in sloshing modes, and hydrodynamic responses (wave height, hydrodynamic pressure, base shear, and base moment) for multi-directional earthquake simulator inputs are reported and compared with analytical solutions for liquid-filled vessels. The impact of seismic (base) isolation on hydrodynamic responses was studied using earthquake simulator inputs generated using a virtual isolation system. Data from the experiments are used to validate a numerical model of the fluid-filled vessel using the Arbitrary Lagrangian Eulerian (ALE) solver in the commercial finite element program LS-DYNA. Validation studies are presented for multi-directional seismic inputs, including rocking motions. Lagrangian modeling approaches using an elastic material formulation for the fluid are also investigated and their limitations and possible applications are identified. Here, the results are broadly applicable to the seismic response of base supported, liquid-filled vessels.

58 GEOSCIENCES↗

Vessel Fabrication Overview

LANL utilizes spherical vessels for numerous basic science, materials, and system performance experiments. These pressure vessels are designed and fabricated to meet the intent of ASME B&PV Section VIII, Division 3 and Code Case 2564. LANL has successfully contracted vessel construction in the past, utilizing HSLA-100 steel. As current vessel inventories approach design life, we are once again embarking upon a series of fabrication contracts to produce replacement components and vessel assemblies to support continued experiment cadence at LANL. LANL’s intent is to ramp up a continuous vessel supply chain for the DOE Complex.

42 ENGINEERING↗

Xylem-dwelling pathogen unaffected by local xylem vessel network properties in grapevines ( Vitis spp.)

Abstract Background and aims Xylella fastidiosa (Xf) is the xylem-dwelling bacterium associated with Pierce’s disease (PD), which causes mortality in agriculturally important species, such as grapevine (Vitis vinifera). The development of PD symptoms in grapevines depends on the ability of Xf to produce cell-wall-degrading enzymes to break up intervessel pit membranes and systematically spread through the xylem vessel network. Our objective here was to investigate whether PD resistance could be mechanistically linked to xylem vessel network local connectivity. Methods We used high-resolution X-ray micro-computed tomography (microCT) imaging to identify and describe the type, area and spatial distribution of intervessel connections for six different grapevine genotypes from three genetic backgrounds, with varying resistance to PD (four PD resistant and two PD susceptible). Key results Our results suggest that PD resistance is unlikely to derive from local xylem network connectivity. The intervessel pit area (Ai) varied from 0.07 ± 0.01 mm2 mm−3 in Lenoir to 0.17 ± 0.03 mm2 mm−3 in Blanc do Bois, both PD resistant. Intervessel contact fraction (Cp) was not statically significant, but the two PD-susceptible genotypes, Syrah (0.056 ± 0.015) and Chardonnay (0.041 ± 0.013), were among the most highly connected vessel networks. Neither Ai nor Cp explained differences in PD resistance among the six genotypes. Bayesian re-analysis of our data shows moderate evidence against the effects of the traits analysed: Ai (BF01 = 4.88), mean vessel density (4.86), relay diameter (4.30), relay density (3.31) and solitary vessel proportion (3.19). Conclusions Our results show that radial and tangential xylem network connectivity is highly conserved within the six different Vitis genotypes we sampled. The way that Xf traverses the vessel network may limit the importance of local network properties to its spread and may confer greater importance on host biochemical responses.

Plant Sciences↗