Variable Transmission Line Ratings

This paper outlines the concept of variable-transmission facility ratings. This topic is of heightened importance following the recent Federal Energy Regulatory Commission (FERC) Order No. 881 which requires the implementation of ambient adjusted ratings (AARs) for FERC jurisdictional portions of the transmission system. Additionally, FERC issued an Advanced Notice of Proposed Rulemaking (ANOPR) implying a future order on Dynamic Line Rating (DLR) requirements. The various types of facility-rating methodologies will be discussed with a focus on how they can benefit the stability, capacity, and reliability of the grid.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Sensitivity Effects of High Temperature Overhead Conductors to Line Rating Variables

For traditional overhead transmission lines, the maximum allowable conductor operating temperature on ASCR, AAC, or AAAC lines for determining the static line ratings can be quite low, typically well under 100 C. At these low temperatures, the primary driver for determining static line ratings are assumptions made about the wind speed and direction and the ambient temperature. Assumptions for solar loading and emitted thermal radiation, driven by line emissivity and absorptivity, are secondary factors, and only provide small changes to the static ratings. However, when considering newer high temperature conductors such as ACSS, ACCR, ZTACIR, and ACCC® the maximum allowable conductor temperatures can be significantly higher, up to 250° C. This higher temperature shifts the importance of the emissivity assumptions of the overhead transmission line, due to the nature of the T4 dependence of the radiative heat loss compared to the T1 dependence of the convective heat loss, as well as shifting the dependency on local wind conditions. Typical assumptions in the United States for the emissivity/absorptivity of overhead transmission lines in determining the static ratings are to use a value of 0.5 for both parameters or set a value in the range of 0.7 to 0.9. Recent experimental tests at EPRI have shown that higher emissivity aging assumptions may not be valid in some regions of the US, and that actual values may be much lower (0.25-0.45) than older studies have predicted (0.8-0.9). Here, the assumptions of different US Regional Transmission Operators (RTOs) and different utilities within RTOs are examined for the static ratings for traditional lower operating temperatures up to 100° C as well as with the higher maximum temperature conductors associated with newer conductor designs at 250° C. The sensitivity of the static ratings is examined at both lower and higher temperature conductors with respect to overhead line emissivity and absorptivity, wind speed, wind direction, and solar loading, and ambient temperature. It is shown that the effects of the conductor absorptivity, solar flux and ambient temperature on the static rating are increased when the transmission line has a lower maximum conductor temperature. The effects of the conductor emissivity, wind direction and wind speed have increased effects on the static rating when the transmission line has a higher maximum conductor temperature. In addition, example weather data is used to calculate the conductor temperature with different line emissivity and absorptivity assumptions. This shows the effect of assumptions made for emissivity only has a minor impact for low temperature lines, but for high temperature transmission lines can cause a 150-200° C temperature swing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sensitivity Effects of High Temperature Overhead Conductors to Line Rating Variables

IEEE/CIGRE standards provide a base for overhead transmission line ratings Steady State Ampacity industry standard for Static Ratings using conservative environmental assumptions Measurement of many types of sensors provide a possibility to provide more capacity as a time varying capability Direct sensors of line temperature, tension, or sag provide critical, location specific information. Require complex transformation to determine line ampacity rating Are direct measurements sensors placed at key location(s)? Testing and careful calibration of sensors required Need to understand impact of uncertainties on sensors/measurements/ and forecasts

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integration of New Technology Considering the Trade-Offs Between Operational Benefits and Risks: A Case Study of Dynamic Line Rating

Electric grid operators are adept at handling complexity and uncertainty. However, with increasing introduction of renewable generation, distributed energy resources, and more frequent severe weather events, operators will experience new workload and challenging decision scenarios. Here, this paper quantifies risks and benefits from an operator's perspective of introducing weather based forecast Dynamic Line Ratings (DLR) using variable wind conditions in addition to ambient temperature to relieve transmission congestion and facilitating more offshore wind (OSW). A concept of operations (CONOPS) applied to a forecast DLR implementation and its integration with OSW is defined. A method for evaluating tradeoffs of derating to make the rating more conservative but decreasing the benefit was developed and applied to a case study for two existing overhead transmission lines on Long Island, New York. The CONOPS uses historical day-ahead and hour-ahead High Resolution Rapid Refresh weather forecasts and weather station data to support planning and real-time operations. The analysis determines the risk of downgrades in real-time operational rating compared to the forecast and quantifies the frequency and severity of last-minute downgrades. The risk is compared against the benefits in increased capacity to provide insights on the additional amount of uncertainty DLR and OSW will add to the operator's workload.

17 WIND ENERGY↗

Sensitive Procedures for Determining the Permeation Resistance of Chlorinated Polyethylene Against Liquid Propellants

The permeation resistance of chlorinated polyethylene (CPE) used in totally encapsulating chemical protective suits against the aerospace fuels hydrazine, monomethylhydrazine, and uns-dimethylhydrazine was determined by measuring the breakthrough time (BT) and time-averaged vapor transmission rate (VTR) using procedures consistent with ASTM F 739 and ASTM F 1383. Two exposure scenarios were simulated: a 2 hour (h) fuel vapor exposure, and a liquid fuel "splash" followed by a 2 h vapor exposure. To simulate internal suit pressure during operation, a positive differential pressure of 0.3 in. water (75 Pa) on the collection side of the permeation apparatus was used. Using the available data, a model was developed to estimate propellant concentrations inside an air-line fed, totally encapsulating chemical protective suit. Concentrations were calculated under simulated conditions of fixed vapor transmission rate, variable breathing air flow rate, and variable splash exposure area. Calculations showed that the maximum allowable permeation rates of hydrazine fuels through CPE were of the order of 0.05 to 0.08 ng/sq cm min for encapsulating suits with low breathing air flow rates (of the order of 5 scfm or 140 L min-1). Above these permeation rates, the 10 parts-per-billion (ppb) threshold limit value time-weighted average could be exceeded. To evaluate suit performance at 10 ppb threshold-limiting value/time-weighted average level concentrations, use of a sensitive analytical method such as cation exchange high performance liquid chromatography with amperometric detection was found to be essential. The analytical detection limit determines the lowest measurable VTR, which in turn governed the lowest per meant concentration that could be calculated inside the totally encapsulating chemical protective suit.

Waller, Jess M.↗

INVESTIGATION OF A DYNAMIC POWER LINE RATING CONCEPT FOR IMPROVED WIND ENERGY INTEGRATION OVER COMPLEX TERRAIN

Dynamic Line Rating (DLR) is a smart grid technology that allows the rating of power line to be based on real-time conductor temperature dependent on local weather conditions. In current practice overhead power lines are generally given a conservative rating based on worst case weather conditions. Using historical weather data collected over a test bed area, we demonstrate there is often additional transmission capacity not being utilized with the current static rating practice. We investigate a new dynamic line rating methodology using computational fluid dynamics (CFD) to determine wind conditions along transmission lines at dense intervals. Simulated results are used to determine conductor temperature by calculating the transient thermal response of the conductor under variable environmental conditions. In calculating the conductor temperature, we use both a calculation with steady-state assumption and a transient calculation. Under low wind conditions, steady-state assumption predicts higher conductor temperatures that could lead to curtailments, whereas transient calculations produce conductor temperatures that are significantly lower, implying the availability of additional transmission capacity.

13 HYDRO ENERGY↗

Probabilistic Approach to Quantifying the Contribution of Variable Generation and Transmission to System Reliability: Preprint

The increasing electrical load served by variable generation (VG), such as wind and solar energy, in the United States and many other countries has stimulated an interesting line of research to better quantify the capacity value of these resources. Methods applied traditionally to thermal units based on their average outage rates do not apply to VG because of their uncertain and non-dispatchablenature. The North American Electric Reliability Corporation's Integration of Variable Generation Task Force recently released a report that highlighted the need to develop and benchmark underlying loss-of-load expectation and related metrics that reasonably and fairly calculate the contribution to planning reserves, or capacity value, of solar and wind power. As the fraction of generation comingfrom VG becomes more significant, their estimated capacity value will have a larger impact on system planning. In this paper, we provide a method to include VG in traditional probabilistic-based adequacy methods. This method has been implemented in the Renewable Energy Probabilistic Resource Assessment tool developed at the National Renewable Energy Laboratory. Through an example based on the U.S. Western Interconnection, this method is applied to assess the effect that transmission can have on resource adequacy. We also analyze the interactions between available transmission and capacity value for VG.

14 SOLAR ENERGY↗

Detecting structural variances of Co3O4 catalysts by controlling beam-induced sample alterations in the vacuum of a transmission electron microscope

Abstract This article summarizes core aspects of beam-sample interactions in research that aims at exploiting the ability to detect single atoms at atomic resolution by mid-voltage transmission electron microscopy. Investigating the atomic structure of catalytic Co 3 O 4 nanocrystals underscores how indispensable it is to rigorously control electron dose rates and total doses to understand native material properties on this scale. We apply in-line holography with variable dose rates to achieve this goal. Genuine object structures can be maintained if dose rates below ~100 e/Å 2 s are used and the contrast required for detection of single atoms is generated by capturing large image series. Threshold doses for the detection of single atoms are estimated. An increase of electron dose rates and total doses to common values for high resolution imaging of solids stimulates object excitations that restructure surfaces, interfaces, and defects and cause grain reorientation or growth. We observe a variety of previously unknown atom configurations in surface proximity of the Co 3 O 4 spinel structure. These are hidden behind broadened diffraction patterns in reciprocal space but become visible in real space by solving the phase problem. An exposure of the Co 3 O 4 spinel structure to water vapor or other gases induces drastic structure alterations that can be captured in this manner.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WECC Variable Generation Planning Reference Book: Appendices

The document titled “WECC Variable Generation Planning Reference Book”. This book is divided into two volumes; one is the main document (volume 1)and the other is appendices (volume 2). The main document is a collection of the best practices and the information regarding the application and impact of variables generation on power system planning. This volume (appendices) has additional information on the following topics: Probabilistic load flow problems. 2. Additional useful indices. 3. high-impact low-frequency (HILF) events. 4. Examples of wide-area nomograms. 5. Transmission line ratings, types of dynamic rating methods. 6. Relative costs per MW-km of different electric power transmission technologies. 7. Ultra-high voltage (UHV) transmission. 8.High voltage direct current (VSC-HVDC). 9. HVDC. 10. Rewiring of existing transmission lines. 11. High-temperature low sag (HTLS) conductors. 12. The direct method and energy functions for transient stability analysis in power systems. 13.Blackouts caused by voltage instability. 14. Algorithm for parameter continuation predictor-corrector methods. 15. Approximation techniques available for security regions. 16. Impacts of wind power on power system small signals stability. 17. FIDVR. 18. FACTS. 19. European planning standard and practices. 20. International experience in wind and solar energy sources. 21. Western Renewable Energy Zones (WREZ). 22. various energy storage technologies. 23. demand response. 24. BA consolidation and cooperation options. 25. generator power management requirements and 26. European planning guidelines.

Makarov, Yuri V.↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

As we know, power transformers are the most critical asset of the transmission network. Although highly reliable, they still can fail prematurely or ultimately retire at the end of their service life. In today’s design practices, transformers are tailored to their specific application and therefore cannot replace each other unless identical. Additionally, they provide minimal support to the grid operation and therefore limit the grid flexibility and resiliency when facing severe conditions. In this presentation, we will introduce the concept of flexible power transformer and demonstrate how one single unit can serve as a spare to multiple units in a given fleet, allow to control the power flow between transformers or lines operating in parallel and ultimately be used to limit subsequent faults in transmission lines. We will also introduce the world’s first prototype in operation, a 60MVA, 165kV flexible autotransformer.

flexible power transformer, autotransformer, varia↗

Chance Constrained Optimal Power Flow: Risk-Aware Network Control under Uncertainty

When uncontrollable resources fluctuate, Optimum Power Flow (OPF), routinely used by the electric power industry to re-dispatch hourly controllable generation (coal, gas and hydro plants) over control areas of transmission networks, can result in grid instability, and, potentially, cascading outages. This risk arises be cause OPF dispatch is computed without awareness of major uncertainty, in particular fluctuations in renewable output. As a result, grid operation under the OPF with renewable variability can lead to frequent conditions where power line flow ratings are significantly exceeded. Such a condition, which is borne by simulations of real grids, would likely resulting in automatic line tripping to protect lines from thermal stress, a risky and undesirable outcome which compromises stability. Smart grid goals include a commitment to large penetration of highly fluctuating renewables, thus calling to reconsider current practices, in particular the use of standard OPF. Our Chance Constrained (CC) OPF corrects the problem and mitigates dangerous renewable fluctuations with minimal changes in the current operational procedure. Assuming availability of a reliable wind forecast parameterizing the distribution function of the uncertain generation, our CC-OPF satisfies all the constraints with high probability while simultaneously minimizing the cost of economic re-dispatch. CC-OPF allows efficient implementation, e.g. solving a typical instance over the 2746-bus Polish network in 20s on a standard laptop.

Energy Planning, Policy, & Economy(29)↗

Improving the maximum transmission distance of continuous-variable quantum key distribution using a noiseless amplifier

We show that the maximum transmission distance of continuous-variable quantum key distribution in presence of a Gaussian noisy lossy channel can be arbitrarily increased using a heralded noiseless linear amplifier. We explicitly consider a protocol using amplitude and phase modulated coherent states with reverse reconciliation. Assuming that the secret key rate drops to zero for a line transmittance T{sub lim}, we find that a noiseless amplifier with amplitude gain g can improve this value to T{sub lim}/g{sup 2}, corresponding to an increase in distance proportional to log g. We also show that the tolerance against noise is increased.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Predictability of Malaria Transmission Intensity in the Mpumalanga Province, South Africa, Using Land Surface Climatology and Autoregressive Analysis

There has been increasing effort in recent years to employ satellite remotely sensed data to identify and map vector habitat and malaria transmission risk in data sparse environments. In the current investigation, available satellite and other land surface climatology data products are employed in short-term forecasting of infection rates in the Mpumalanga Province of South Africa, using a multivariate autoregressive approach. The climatology variables include precipitation, air temperature and other land surface states computed by the Off-line Land-Surface Global Assimilation System (OLGA) including soil moisture and surface evaporation. Satellite data products include the Normalized Difference Vegetation Index (NDVI) and other forcing data used in the Goddard Earth Observing System (GEOS-1) model. Predictions are compared to long- term monthly records of clinical and microscopic diagnoses. The approach addresses the high degree of short-term autocorrelation in the disease and weather time series. The resulting model is able to predict 11 of the 13 months that were classified as high risk during the validation period, indicating the utility of applying antecedent climatic variables to the prediction of malaria incidence for the Mpumalanga Province.

Grass, David↗

X-RAY DETERMINATION OF THE VARIABLE RATE OF MASS ACCRETION ONTO TW HYDRAE

Diagnostics of electron temperature (T{sub e} ), electron density (n{sub e} ), and hydrogen column density (N{sub H}) from the Chandra High Energy Transmission Grating spectrum of He-like Ne IX in TW Hydrae (TW Hya), in conjunction with a classical accretion model, allow us to infer the accretion rate onto the star directly from measurements of the accreting material. The new method introduces the use of the absorption of Ne IX lines as a measure of the column density of the intervening, accreting material. On average, the derived mass accretion rate for TW Hya is 1.5 Multiplication-Sign 10{sup -9} M{sub Sun} yr{sup -1}, for a stellar magnetic field strength of 600 G and a filling factor of 3.5%. Three individual Chandra exposures show statistically significant differences in the Ne IX line ratios, indicating changes in N{sub H}, T{sub e} , and n{sub e} by factors of 0.28, 1.6, and 1.3, respectively. In exposures separated by 2.7 days, the observations reported here suggest a five-fold reduction in the accretion rate. This powerful new technique promises to substantially improve our understanding of the accretion process in young stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulating AXAF Grating Spectra of Accreting White Dwarfs

We present simulated AXAF spectra of accreting white dwarfs, using parameters appropriate for magnetic cataclysmic variables. The very high spectral resolution that can be obtained with the High-Energy Transmission Grating of AXAF can resolve the keV X-ray emission lines that characterize the temperature, density and velocity profiles of the shock-heated emission regions of these systems. These simulations demonstrate that actual spectra will allow us to place constraints on the white-dwarf mass and the accretion rate of the systems. The high-resolution spectra also allow the measurement of the velocity of the accretion flow in regions close to the white-dwarf surface.

Tennant, Allyn F.↗

Advanced Flexible Transformers

Advanced grid solutions are comprised of advanced transmission technologies and grid enhancing technologies. In this webinar, experts will provide participants with insights into eight advanced grid solutions. The advanced transmission technologies that will be discussed include point-to-point high voltage direct current and advanced conductoring and the grid enhancing technologies that experts will explore include topology optimization, advanced power flow control, dynamic line rating, energy storage, virtual power plants, and advanced flexible transformers

flexible power transformer, power flow controller,↗

EVOLUTION OF X-RAY SPECTRA AND LIGHT CURVES OF V1494 AQUILAE

We present six Chandra X-ray spectra and light curves obtained for the nova V1494 Aql (1999 No. 2) in outburst. The first three observations were taken with the Advanced CCD Imaging Spectrometer (ACIS-I) on days 134, 187, and 248 after outburst. The count rates were 1.00, 0.69, and 0.53 counts s{sup -1}, respectively. We found no significant periodicity in the ACIS light curves. The X-ray spectra show continuum emission and lines originating from N and O. We found acceptable spectral fits using isothermal APEC models with significantly increased elemental abundances of O and N for all observations. On day 248 after outburst a bright soft component appeared in addition to the fading emission lines. The Chandra observations on days 300, 304, and 727 were carried out with the High Resolution Camera/Low Energy Transmission Grating Spectrometer (LETGS). The spectra consist of continuum emission plus strong emission lines of O and N, implying a high abundance of these elements. On day 300, a flare occurred and periodic oscillations were detected in the light curves taken on days 300 and 304. This flare must have originated deep in the outflowing material since it was variable on short timescales. The spectra extracted immediately before and after the flare are remarkably similar, implying that the flare was an extremely isolated event. Our attempts to fit blackbody, cloudy, or APEC models to the LETGS spectra failed, owing to the difficulty in disentangling continuum and emission-line components. The spectrum extracted during the flare shows a significant increase in the strengths of many of the lines and the appearance of several previously undetected lines. In addition, some of the lines seen before and after the flare are not present during the flare. On day 727 only the count rate from the zeroth order could be derived, and the source was too faint for the extraction of a light curve or spectrum.

79 ASTRONOMY AND ASTROPHYSICS↗

November 2016 HERMES Outdoor Shot Series 10268-313: Spherical Compton Diodes

In November 2016, the High-Energy Radiation Megavolt Electron Source (HERIVIES)-III gamma simulator was used in a series of physics experiments. As part of the environmental characterization, six Spherical Compton Diodes (SCDs) were fielded in order to measure the dose rate at various locations. This report documents the locations, calibration, compensation, and analysis of these sensors. Several short studies are conducted of the SCD signals examining their change with respect to distance, comparison to other sensors and historical data, evaluation of the log-derivative, and signal behavior with a partially obscured converter. Recommendations for future work includes study and extension of SCD bandwidth, characterization of the HERMES-III output spectrum variability, and study of sensor signals with the courtyard shielded from the top of the Magnetically Insulated Transmission Line (MITL).

61 RADIATION PROTECTION AND DOSIMETRY↗