Modeling Variable-Impedance, Magnetically Insulated, Transmission Lines

Coupling generator current to electron-beam loads and dynamic-inductance loads (z pinches) is greatly improved with low-inductance vacuum transmission lines. Typically, magnetically insulated transmission lines (MITLs) utilize nearly constant impedance geometries where the minimum impedance (anode-cathode gap) is limited by electron loss during the setup of magnetic insulation. Constant-impedance MITL designs are not optimized for low inductance (Zτ) when given a constraint on vacuum electron flow. We describe the design and the modeling of MITLs that have a nonconstant impedance. The baseline variable-impedance MITL designs are based on equilibrium vacuum-electron flow models [1] that are incorporated into the Screamer circuit code [2]. Such designs satisfy the MITL limits in the areal density of the loss current and have magnetically insulated flow that is stable everywhere along the MITL. Different MITL designs are then modeled analytically and with a 2-D particle-in-cell computer code in order to quantify subtle electron losses driven by changes to the vacuum impedance as a function of distance along the transmission line. We present a variable-impedance MITL design that delivers more current with a lower inductance than found in constant-impedance MITL designs.

47 OTHER INSTRUMENTATION↗

Evaluating Variable-Impedance Magnetically-Insulated Transmission Lines as a Risk-Mitigation Measure for Next-Generation Pulsed Power

This project has produced the first detailed characterizations of power flow resulting from applying the “variable-impedance MITL” concept to real-life systems in Sandia’s pulsed power program (Z and next-generation pulsed power (NGPP)). We present simulation results and analyses for constant-impedance versions of both Z and NGPP and survey the operational viability of several variable-impedance re-designs in the parameter space of linear tapers. Circuit modeling (SCREAMER/Bertha) was used to pinpoint promising candidate designs, and EM-PIC (Empire) simulations were used to evaluate these candidates more rigorously. This approach was particularly successful in the Z regime which resulted in the identification of several viable variable-impedance MITL designs for each level. The approach was more challenged in the operating space NGPP occupies, producing data points that speak to a more restrictive design space due to anode plasma turn-on. In the end, we were able to converge on one viable variable-impedance design for the highest inductance line (level “F”) and one for the highest current line (level “A”). Altogether, the body of simulation evidence presented in this report suggest there does exist flexibility in operating space for magnetically-insulated transmission lines (MITLs) having variable geometric impedance to be a potential enabling technology for safely increasing current delivery (and potentially lowering stack voltage) in pulsed-power drivers by manipulating electron losses; however, operating points for a particular design must be carefully screened. Circuit and EM-PIC modeling provided consistent verdicts in safe operating regimes for operational viability, but additional physics such as anode plasma turn-on which is included in Empire but not in SCREAMER/Bertha was found to be a critical factor affecting power flow that lead to different assessments between the codes. It is not always the case that the occurrence of anode plasma caused a design to fail (some designs turned on anode plasma yet still delivered load currents meeting design targets); the details matter such as how early in the pulse anode surfaces break down (and how large a region). However, in every case that it did fail it was found that the feedback from anode plasma was the cause (i.e., turning off the anode plasma model in Empire restored agreement with the circuit model prediction). As circuit simulations represent an efficient and practical means of surveying design space compared to more computationally-expensive approaches such as EM-PIC, it could be prudent to invest in the research and development of models to include the effects of anode plasma such as ion emission in circuit codes. The variable-impedance MITL design is a new concept that enables controlled manipulation of the initial electron losses in the outer MITL and can be tested on Z today. We encourage follow-on work to explore further optimization (including alternative variable-impedance profiles, e.g., having constant dZ/dR), and to confirm the major findings presented in this report by fielding test hardware on actual Z shots.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Superconducting fault current-limiter with variable shunt impedance

A superconducting fault current-limiter is provided, including a superconducting element configured to resistively or inductively limit a fault current, and one or more variable-impedance shunts electrically coupled in parallel with the superconducting element. The variable-impedance shunt(s) is configured to present a first impedance during a superconducting state of the superconducting element and a second impedance during a normal resistive state of the superconducting element. The superconducting element transitions from the superconducting state to the normal resistive state responsive to the fault current, and responsive thereto, the variable-impedance shunt(s) transitions from the first to the second impedance. The second impedance of the variable-impedance shunt(s) is a lower impedance than the first impedance, which facilitates current flow through the variable-impedance shunt(s) during a recovery transition of the superconducting element from the normal resistive state to the superconducting state, and thus, facilitates recovery of the superconducting element under load.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Method and system for measurement of impedance of electrochemical devices

The present disclosure provides methods for determining impedance of an electrochemical device by electrically connecting a variable impedance in parallel with the electrochemical device; electrically connecting a power supply to the electrochemical device, the power supply generating a power supply current; modulating a current through the variable impedance; measuring a stack current flowing through the electrochemical device; measuring, at the electrochemical device, a voltage across at least a portion of the electrochemical device; and calculating, based on the measured stack current and the measured voltage, the impedance of the electrochemical device. Systems for performing such methods are also provided.

Klein, Jr., Walter Ellis↗

Petawatt pulsed-power accelerator

A petawatt pulsed-power accelerator can be driven by various types of electrical-pulse generators, including conventional Marx generators and linear-transformer drivers. The pulsed-power accelerator can be configured to drive an electrical load from one- or two-sides. Various types of loads can be driven; for example, the accelerator can be used to drive a high-current z-pinch load. When driven by slow-pulse generators (e.g., conventional Marx generators), the accelerator comprises an oil section comprising at least one pulse-generator level having a plurality of pulse generators; a water section comprising a pulse-forming circuit for each pulse generator and a level of monolithic triplate radial-transmission-line impedance transformers, that have variable impedance profiles, for each pulse-generator level; and a vacuum section comprising triplate magnetically insulated transmission lines that feed an electrical load. When driven by LTD generators or other fast-pulse generators, the need for the pulse-forming circuits in the water section can be eliminated.

Stygar, William A.↗

On the design of magnetically insulated transmission lines for z -pinch loads

Many papers have been published on the theory of magnetic insulation and the use of Z flow analysis of magnetically insulated transmission lines (MITL’s). We describe herein a novel design process using the circuit code SCREAMER , for a real-world MITL for z-pinch loads based on the Z flow model of magnetic insulation. In particular, we design a 15-TW, 10-MA, 100 ns double-disk transmission lines using only circuit modeling tools and Z flow analysis of the MITL. Critical issues such as current loss to the anode during the setup of magnetic insulation and the transition from a non-emitting vacuum power feed to a MITL play a large role in the MITL design. This very rapid design process allows us for the first time to explore innovative MITL designs such as variable-impedance MITL’s that provide a significantly lower total inductance and improved energy delivery to the load. In conclusion the tedious process of modeling the final MITL design with highly resolved 2-D and 3-D electromagnetic particle-in-cell codes occurs as a validation step, not as part of the design process.

42 ENGINEERING↗

Remotely powered line monitor

Improved devices, apparatuses, systems, and methods involving the use of field probes with voltage-controlled variable impedance elements and surface-launched acoustic wave devices, including surface acoustic wave (SAW) devices and SAW sensor-tag wireless interface devices to measure voltage and current in current carrying conductors (CCCs) via measurement of the electric fields and magnetic fields around said CCCs are disclosed. The devices, apparatuses, systems, and methods taught in the present invention include a remotely powered line-mounted measurement unit that requires no connection to electrical ground for operation, and that has no internal energy source, no energy harvesting or power conditioning circuitry, no discrete energy storage components, and no radio. The devices, apparatuses, systems, and methods taught in the present invention also provide for determining the phase (leading or lagging) of the current relative to the voltage in AC power systems, and also provide for measurement of temperature of the conductor.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Self-triggering superconducting fault current limiter

A modular and scaleable Matrix Fault Current Limiter (MFCL) that functions as a "variable impedance" device in an electric power network, using components made of superconducting and non-superconducting electrically conductive materials. The matrix fault current limiter comprises a fault current limiter module that includes a superconductor which is electrically coupled in parallel with a trigger coil, wherein the trigger coil is magnetically coupled to the superconductor. The current surge doing a fault within the electrical power network will cause the superconductor to transition to its resistive state and also generate a uniform magnetic field in the trigger coil and simultaneously limit the voltage developed across the superconductor. This results in fast and uniform quenching of the superconductors, significantly reduces the burnout risk associated with non-uniformity often existing within the volume of superconductor materials. The fault current limiter modules may be electrically coupled together to form various "n" (rows).times."m" (columns) matrix configurations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Impedance Response Influenced by Variability in the Random Distribution of Physical Properties of Coated Materials in Two-Dimensional Space

Heterogeneous physical characteristics of a system featuring a single-layer film on a metallic surface have been explored via its impedance response. The Nyquist plot showed a distorted semicircle, indicative of the system's unique distribution characteristics. Utilizing a copula-based probability method, a two-dimensional deterministic impedance model was successfully integrated, accounting for spatial physical properties such as permittivity and electrical conductivity. This strategy enabled in-depth exploration and mechanistic quantification of a broad spectrum of properties. A quantitative understanding of impedance signal alterations, characterized by normally or log-normally correlated variables, was achieved through the variation in aspect ratio and characteristic frequency of the impedance spectra. Log-normally distributed electrical properties provided a superior representation of the distorted impedance spectra. As coefficient of variation (CV) values fluctuated, the aspect ratio and characteristic frequency showed heightened sensitivity to log-normal permittivity compared to log-normal electrical conductivity. Notably, a marked positive linear correlation between electrical properties resulted in an impedance response that approximated perfect semicircular spectra. The variability in the electrical properties' distribution was demonstrated by considering the correlation coefficient between electrical conductivity and the z-direction position. Furthermore, the highest aspect ratio of the impedance spectra was observed when the electrical conductivity was randomly distributed across the z-direction space.

36 MATERIALS SCIENCE↗

Predicting oncology drug-induced cardiotoxicity with donor-specific iPSC-CMs—a proof-of-concept study with doxorubicin

Abstract Many oncology drugs have been found to induce cardiotoxicity in a subset of patients, which significantly limits their clinical use and impedes the benefit of lifesaving anticancer treatments. Human induced pluripotent stem cell-derived cardiomyocytes (iPSC-CMs) carry donor-specific genetic information and have been proposed for exploring the interindividual difference in oncology drug-induced cardiotoxicity. Herein, we evaluated the inter- and intraindividual variability of iPSC-CM-related assays and presented a proof of concept to prospectively predict doxorubicin (DOX)-induced cardiotoxicity (DIC) using donor-specific iPSC-CMs. Our findings demonstrated that donor-specific iPSC-CMs exhibited greater line-to-line variability than the intraindividual variability in impedance cytotoxicity and transcriptome assays. The variable and dose-dependent cytotoxic responses of iPSC-CMs resembled those observed in clinical practice and largely replicated the reported mechanisms. By categorizing iPSC-CMs into resistant and sensitive cell lines based on their time- and concentration-related phenotypic responses to DOX, we found that the sensitivity of donor-specific iPSC-CMs to DOX may predict in vivo DIC risk. Furthermore, we identified a differentially expressed gene, DND microRNA-mediated repression inhibitor 1 (DND1), between the DOX-resistant and DOX-sensitive iPSC-CMs. Our results support the utilization of donor-specific iPSC-CMs in assessing interindividual differences in DIC. Further studies will encompass a large panel of donor-specific iPSC-CMs to identify potential novel molecular and genetic biomarkers for predicting DOX and other oncology drug-induced cardiotoxicity.

Toxicology↗

Flexible Transformers for Resilient and Adaptable Power Systems

This paper presents experience with grid ready flexible transformer unit, which is in service for two years without any difficulty. Transformer unit is capable of changing short circuit impedance on load and it is equipped with state-of-the-art monitoring system.

field validation↗

Advanced Flexible Transformers

Advanced grid solutions are comprised of advanced transmission technologies and grid enhancing technologies. In this webinar, experts will provide participants with insights into eight advanced grid solutions. The advanced transmission technologies that will be discussed include point-to-point high voltage direct current and advanced conductoring and the grid enhancing technologies that experts will explore include topology optimization, advanced power flow control, dynamic line rating, energy storage, virtual power plants, and advanced flexible transformers

flexible power transformer, power flow controller,↗

Local impedance imaging of boron-doped polycrystalline diamond thin films

Local impedance imaging (LII) was used to visualise surficial deviations of AC impedances in polycrystalline boron-doped diamond (BDD). The BDD thin film electrodes were deposited onto the highly doped silicon substrates via microwave plasma-enhanced CVD. The studied boron dopant concentrations, controlled by the [B]/[C] ratio in plasma, ranged from 1 × 10{sup 16} to 2 × 10{sup 21} atoms cm{sup −3}. The BDD films displayed microcrystalline structure, while the average size of crystallites decreased from 1 to 0.7 μm with increasing [B]/[C] ratios. The application of LII enabled a direct and high-resolution investigation of local distribution of impedance characteristics within the individual grains of BDD. Such an approach resulted in greater understanding of the microstructural control of properties at the grain level. We propose that the obtained surficial variation of impedance is correlated to the areas of high conductance which have been observed at the grain boundaries by using LII. We also postulate that the origin of high conductivity is due to either preferential boron accumulation, the presence of defects, or sp{sup 2} regions in the intragrain regions. The impedance modulus recorded by LII was in full agreement with the bulk impedance measurements. Both variables showed a decreasing trend with increasing [B]/[C] ratios, which is consistent with higher boron incorporation into BDD film.