Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vacuum break”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Facility and Methods Developed for Simulated Space Vacuum Ultraviolet Exposure Testing of Polymer Films

Vacuum ultraviolet (VUV) radiation of wavelengths between 115 and 200 nm produced by the Sun in the space environment can degrade polymer films, producing changes in their optical, mechanical, and chemical properties. These effects are particularly important for thin polymer films being considered for ultralightweight space structures, because, for most polymers, VUV radiation is absorbed in a thin surface layer. The NASA Glenn Research Center has developed facilities and methods for long-term ground testing of polymer films to evaluate space environmental VUV radiation effects. VUV exposure can also be used as part of combined or sequential simulated space environmental exposures to determine combined damaging effects with other aspects of the space environment, which include solar ultraviolet radiation, solar flare x-rays, electron and proton radiation, atomic oxygen (for low-Earth-orbit missions), and temperature effects. Because the wavelength sensitivity of VUV damage is not well known for most materials, Glenn's VUV facility uses a broad-spectrum deuterium lamp with a magnesium fluoride window that provides output between 115 and 200 nm. Deuterium lamps of this type were characterized by the National Institute of Standards and Technology and through measurements at Glenn. Spectral irradiance measurements show that from approximately 115 to 160 nm, deuterium lamp irradiance can be many times that of air mass zero solar irradiance, and as wavelength increases above approximately 160 nm, deuterium lamp irradiance decreases in comparison to the Sun. The facility is a cryopumped vacuum chamber that achieves a system pressure of approximately 5310(exp -6) torr. It contains four individual VUV-exposure compartments in vacuum, separated by water-cooled copper walls to minimize VUV radiation and any sample contamination cross interactions between compartments. Each VUV-exposure compartment contains a VUV deuterium lamp, a motor-controlled sample stage coupled with a moveable cesium iodide VUV phototube, and two thermocouples for temperature measurement. The vacuum chamber and exterior equipment is shown. Each VUV lamp is located at the top of the chamber with its projection-tube pushed through an O-ring compression fitting. The lamp assemblies are located on ports that can be isolated from the rest of the vacuum chamber, permitting maintenance or replacement of the lamps without breaking vacuum in the main chamber where the samples are located. A view of two of the four interior VUV-exposure compartments, including the moveable sample stages and detector holders is also shown. Glenn is using this facility to support testing of Next Generation Space Telescope sunshield materials that is being led by the NASA Goddard Space Flight Center and to develop an understanding of the wavelength, intensity, and temperature dependence of VUV-induced polymer degradation.

Dever, Joyce A.↗

Optical Integrating Sphere for Vacuum Ultraviolet

Optical integrating sphere with integral sliding sample holder saves time by allowing radiometric measurements made on each of four samples without breaking vacuum. Designed to operate with interior evacuated so dye samples illuminated with short-wavelength ultraviolet strongly absorbed by air; need not be evacuated when using longer wavelengths. Device mounts on monochromator and evacuated through port that admits light from monochromator.

Butner, C. L.↗

Steady State Vacuum Ultraviolet Exposure Facility With Automated Calibration Capability

NASA Glenn Research Center at Lewis Field designed and developed a steady state vacuum ultraviolet automated (SSVUVa) facility with in situ VUV intensity calibration capability. The automated feature enables a constant accelerated VUV radiation exposure over long periods of testing without breaking vacuum. This test facility is designed to simultaneously accommodate four isolated radiation exposure tests within the SSVUVa vacuum chamber. Computer-control of the facility for long, term continuous operation also provides control and recording of thermocouple temperatures, periodic recording of VUV lamp intensity, and monitoring of vacuum facility status. This paper discusses the design and capabilities of the SSVUVa facility.

Stueber, Thomas J.↗

Anti-Fog Coatings For Spacesuit Helmets

A permanent and robust anti-fog coating was developed that is applied to the interior of polycarbonate spacesuit helmets. The coating is a mechanically resilient and permanent superhydrophilic (SHPL) layer produced by a two-step process consisting of a plasma processing pre-etch followed by the deposition of an optically transparent Diamond Like Carbon (DLC) coating to achieve an anti-fog, SHPL-DLC layer with Water Contact Angle (WCA) < 10°. The all-dry vacuum process consists of an oxygen plasma etching to engineer the surface of the polycarbonate, creating a well-controlled nanotextured morphology, which is key to the superhydrophilic properties, followed by vacuum deposited Plasma Enhanced Chemical Vapor Deposition (PECVD) DLC coating with high surface energy. The process is carried out at low temperatures compatible with polycarbonate materials and the two steps are performed back-to-back without breaking vacuum between steps. The process is readily scalable and compatible with large scale production volumes. The SHPL-DLC coating was tested for > 200 hours exposure using a breath simulator with no detrimental effect on the coating performance. The coating was also tested for exposure to cleaning fluids, IPA chemical exposure, adhesion testing per ASTM D3359, and abrasion resistance per MIL-E-12397 with no detrimental effects.

Spacesuit↗

Ion thruster system (8-cm) cyclic endurance test

This report describes the qualification test of an Engineering-Model 5-mN-thrust 8-cm-diameter mercury ion thruster which is representative of the Ion Auxiliary Propulsion System (IAPS) thrusters. Two of these thrusters are scheduled for future flight test. The cyclic endurance test described herein was a ground-based test performed in a vacuum facility with a liquid-nitrogen-cooled cryo-surface and a frozen mercury target. The Power Electronics Unit, Beam Shield, Gimal, and Propellant Tank that were used with the thruster in the endurance test are also similar to those of the IAPS. The IAPS thruster that will undergo the longest beam-on-time during the actual space test will be subjected to 7,055 hours of beam-on-time and 2,557 cycles during the flight test. The endurance test was successfully concluded when the mercury in the IAPS Propellant Tank was consumed. At that time, 8,471 hours of beam-on-time and 599 cycles had been accumulated. Subsequent post-test-evaluation operations were performed (without breaking vacuum) which extended the test values to 652 cycles and 9,489 hours of beam-on-time. The Power Electronic Unit (PEU) and thruster were in the same vacuum chamber throughout the test. The PEU accumulated 10,268 hr of test time with high voltage applied to the operating thruster or dummy load.

Dulgeroff, C. R.↗

Integrated material-surface analyzer

These 10 surface-analysis tests can be run without breaking vacuum: secondary-ion mass spectroscopy, ion-scattering spectroscopy, electron-stimulated desorption, residual-gas analysis, auger electron spectroscopy, x-ray photoelectron spectroscopy, ultraviolet photoelectron spectroscopy, characteristic-electron energy-loss spectroscopy, scanning electron microscope, scanning low-energy electron probe. Quadruple mass spectrometer, used in first 4 tests, serves as electron transfer lens in last 6 tests.

Grunthaner, F. J.↗

Modifications of the X-ray source and monitor at the X-ray Calibration Facility

In order to test the instruments aboard the Advanced X-ray Astrophysics Facility (AXAF) some modifications will need to be made in the X-ray Calibration Facility at Marshall. Several of these modifications involve the X-ray source and the monitor. The source was redesigned to increase the spectral purity of the beam and decrease its polarization by minimizing the number of bremsstrahlung photons in the beam. This was accomplished by utilizing an annular electron gun which allowed the beam to take off antiparallel to the direction at which electrons are incident on the anode. Two other features of the source are the conical anode which decreases the effective spot size and a rotatable anode and filter wheel which allow the operator to change targets without breaking vacuum. The monitor is an important part of the facility because it is used to determine the X-ray flux at the target. A commercially available solid-state detector, Si(Li), should be used along with appropriate proportional counters for monitoring. This detector will be particularly useful when energy or wavelength dispersive instruments are tested because of its good resolution.

Newbolt, W. Barlow↗

YBa2Cu3O(7-delta)/Au/Nb sandwich geometry SNS weak links on c-axis oriented YBa2Cu3O(7-delta)

Sandwich geometry superconductor/normal metal/superconductor structures have been fabricated on LaAlO3 and cubic zirconia with laser-ablated, c-axis-oriented YBa2Cu3O(7-delta) base electrodes, 100-600 A of Au, and Nb counter electrodes, all formed in situ without breaking vacuum. Junctions range in size from 5 to 50 micron on a side. Four probe I-V measurements at 4.2 K show RnA products as low as 6 x 10 to the -9th sq cm and critical current densities up to 5.2 kA/sq cm. AC Josephson steps were observed with the application of 10-GHz radiation. The temperature dependence of Jc and the observation of the AC Josephson effect suggest that true supercurrents are present and that they do indeed represent the characteristics of the YBa2Cu3O(7-delta)/Au/Nb structure. The best results were obtained when the devices were annealed at about 450 C in O2 for 30 min after Au deposition.

Foote, M. C.↗

Fabrication of an Aluminum Based Hot Electron Mixer for Terahertz Applications

Aluminum based diffusion cooled hot electron bolometers (HEB) mixers, predicted to have better noise, bandwidth and to require less LO power than Nb based diffusion cooled HEBs, have been fabricated. Preliminary DC tests were performed. The bolometer elements consisted of short (0.1 to 0.3 micron), narrow (0.08 to 0. 15 micron) and thin (11 nm) aluminum wires connected to large contact pads consisting of a novel trilayer Al/Ti/Au. The patterns were defined by electron beam lithography and the metal deposition involved a double angle process, the Aluminum wires being deposited straight on and the pads being deposited at a 45 degree angle without breaking vacuum. The Al/Ti/Au trilayer was developed to provide a way of making contact between the aluminum wire and the gold antenna. The Titanium layer acts as a diffusion barrier to avoid damage of the Aluminum contact and bolometer wire and to lower the transition temperature of the pads to below that of the bolometer wire. The Au layer avoids the formation of an oxide on the Ti layer and provides good electrical contact to the IF/antenna structure. The resistance of the bolometers as a function of temperature was measured. It is clear that below the transition temperature of the wire (1.8K) but above the transition temperature of the contact pads (0.6K), the proximity effect drives most of the bolometer wire normal, causing a very broad transition. This effect should not affect the performance of the bolometers since they will be operated at a temperature below the TC of the pads. This is evident from the IV characteristics measured at 0.3K. RF characterization tests will begin shortly.

Echternach, P. M.↗

JWST NIRSpec Cryogenic Light Shield Mechanism

The focal plane detectors for the Near-Infrared Spectrometer (NIRSpec) instrument on the James Webb Space Telescope (JWST) require a light tight cover for calibration along with an open field-of-view during g round performance testing within a cryogenic dewar. In order to meet the light attenuation requirements and provide open and closed fields of view without breaking vacuum, a light shield mechanism was designe d. This paper describes the details of the light shield mechanism design and test results. Included is information on the labyrinth light p ath design, motor capability and performance, dry film lubrication, m echanism control, and mechanism cryogenic performance results.

Hale, Kathleen↗

JWST NIRSpec Cryogenic Light Shield Mechanism

The focal plane detectors for the Near-Infrared Spectrometer (NIRSpec) instrument on the James Webb Space Telescope (JWST) require a light tight cover for calibration along with an open field-of-view during ground performance testing within a cryogenic dewar. In order to meet the light attenuation requirements and provide open and closed fields of view without breaking vacuum, a light shield mechanism was designed. This paper describes the details of the light shield mechanism design and test results. Included is information on the labyrinth light path design, motor capability and performance, dry film lubrication, mechanism control, and mechanism cryogenic performance results.

Hale, Kathleen↗

NASA MSFC Electrostatic Levitator (ESL) Rapid Quench System

Electrostatic levitation, a form of containerless processing, is an important tool in materials research. Levitated specimens are free from contact with a container; therefore, heterogeneous nucleation on container walls is not possible. This allows studies of deeply undercooled melts. Furthermore, studies of high‐temperature, highly reactive materials are also possible. Studies of the solidification and crystallization of undercooled melts is vital to the understanding of microstructure development, particularly the formation of alloys with unique properties by rapid solidification. The NASA Marshall Space Flight Center (MSFC) Electrostatic Levitator (ESL) lab has recently been upgraded to allow for rapid quenching of levitated materials. The ESL Rapid Quench System uses a small crucible‐like vessel that can be partially filled with a low melting point material, such as a Gallium alloy, as a quench medium. An undercooled sample can be dropped into the vessel to rapidly quench the sample. A carousel with nine vessels sits below the bottom electrode assembly. This system allows up to nine rapid quenches before having to break vacuum and remove the vessels. This new Rapid Quench System will allow materials science studies of undercooled materials and new materials development. In this presentation, the system is described and initial results are presented.

SanSoucie, Michael P.↗

Design/Use of the Remotely Operated Bakeout Box Shutter (ROBBS)

A thermal vacuum box bakeout and certification allows orbital payloads to be cleaned and certified when the background TQCM measurements (a measure of how much molecular contamination is on a payload or chamber) are unacceptable or unmanageable in the standard thermal vacuum chamber. The box bakeout procedure is usually performed in 4 steps: bakeout the box, certify the box, bake out the payload, and finally certify the payload. In the procedure's current setup, the contaminant conduction hole ("lid") is initially open and a vacuum chamber break must occur between the bakeout and certification phases to close the box from the vacuum chamber. This exposure is necessary to allow the outgassed contaminants to escape the box's volume rapidly during bakeout phase, but payload certification isn't usually performed while the lid is still open, because it exposes the payload, TQCM, and box volume to chamber contaminants. The Remotely Operated Bakeout Box Shutter (ROBBS) is a new facility design and will allow the remote closure of the contamination hole while the chamber is still under vacuum, and with little or no time to do so.

Ottens, Brian P.↗

On the measurement of material damping in a simulated space environment

A new, experimental method of measuring the material damping of test models is presented. The method involves measuring the decay of free vibrations as the model is lofted into free-fall in a vacuum. Vibration signals are transmitted through the vacuum by a miniature telemetry system. The resulting data are recorded and later analyzed using a fast Fourier transform technique to determine the percent critical damping. The experimental apparatus offers a unique means to reset the experiment without breaking the vacuum, which reduces the time between runs.

Edberg, D. L.↗

Variable-Temperature Cryostat For Radiation-Damage Testing Of Germanium Detectors

Variable-temperature cryostats developed to study radiation damage to, and annealing of, germanium gamma-ray detectors. Two styles: one accommodates large single detector and one accommodates two medium-sized detectors. New cryostats allow complete testing of large-volume germanium gamma-ray detectors without breaking cryostat vacuum and removing detectors for annealing.

Floyd, Samuel R.↗

Germanium detector vacuum encapsulation

This paper describes an encapsulation technology that should significantly improve the viability of germanium gamma-ray detectors for a number of important applications. A specialized vacuum chamber has been constructed in which the detector and the encapsulating module are processed in high vacuum. Very high vacuum conductance is achieved within the valveless encapsulating module. The detector module is then sealed without breaking the chamber vacuum. The details of the vacuum chamber, valveless module, processing, and sealing method are presented.

Madden, N. W.↗

Method of forming multi-element thin hot film sensors on polyimide film

The invention comprises a method of forming a multi-element, thin hot film sensor on a polyimide film. The sensor is formed by first cleaning one surface of the polyimide. Then, under a continuous vacuum, the surface is simultaneously cleaned by ion bombardment while nickel is deposited by evaporation. The ion beam cleaning is discontinued and copper is then deposited to an initial thickness by evaporation without a break in the vacuum. The vacuum is then removed and a final thickness of copper is deposited by plating. Sensor patterns are then defined in the nickel and copper layers using conventional photolithography and etching techniques.

Hopson, Jr., Purnell↗

Soft CP violation and the global matter-antimatter symmetry of the universe

Scenarios for baryon production are considered within the context of SU(5) and SO(10) grand unified theories where CP violation arises spontaneously. The spontaneous CP symmetry breaking then results in a matter-antimatter domain structure in the universe. Two possible, distinct types of theories of soft CP violation are defined. In the first type the CP nonconservation originates only from the breaking of SU(2) sub L X U(1) symmetry, and in the second type, even at the unification temperature scale, CP violation can emerge as a result of symmetry breaking by the vacuum expectation values of the superheavy Higgs sector scalars.

Senjanovic, G.↗