Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “usdw”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Potential Chemical Impacts of CO2 Leakage on Underground Source of Drinking Water Assessed by Quantitative Risk Analysis

Many geologic carbon storage site options include not only excellent storage reservoirs bounded by effective seal layers, but also Underground Sources of Drinking Water (USDWs). An effective risk assessment and mitigation plan provides maximum protection for USDWs, to respect not only current policy but also to accommodate likely future USDW-specific regulatory protections. The goal of this study is to quantify possible risks to USDWs, specifically risks associated with chemical impacts on USDWs. Reactive transport models involve tremendous computational expense. Therefore, a secondary purpose of this study is to develop, calibrate and test reduced order models specifically for assessing risks of USDW chemical impacts by CO2 leakage from a storage reservoir. In order to achieve these goals, a geochemical model was developed to interpret changes in water chemistry following CO2 intrusion. A response surface methodology (RSM) based on these geochemical simulations was used to quantify associated risks. The case study example for this analysis is the Ogallala aquifer overlying the Farnsworth unit (FWU), an active commercial-scale CO2-enhanced oil recovery field. Specific objectives of this study include: (1) to understand how CO2 leakage is likely to influence geochemical processes in aquifer sediments; (2) to quantify potential risks to the Ogallala groundwater aquifer due to CO2 leakage from the FWU oil reservoir; and (3) to identify water chemistry factors for early detection criteria. Results indicate that the leakage rate would most likely range between 10-14 – 10-10 kg/(m2·year) for typical and likely leakage pathway permeability ranges. Within this range of CO2 leakage rate, groundwater quality is not likely to be significantly impacted. The worst-case scenario yields trace metal concentrations approximately twice as much as the initial value, but these predicted concentrations are still less than one-fifth of regulation-stipulated maximum contamination levels and do not exceed the no-impact thresholds. Finally, the results of this analysis suggest that pH may be an effective geochemical indicator of CO2 leakage.

CO2 leakage, USDWs, Groundwater quality, Risk anal↗

Probabilistic risk-based Area of Review (AoR) determination for a deep-saline carbon storage site

Regulatory oversight of a geologic carbon sequestration (GCS) project relies on iterative estimations, throughout the project lifetime, of the area where increased risks to underground sources of drinking water (USDWs) may occur due to injection of CO2. This area, referred to as Area of Review (AoR), is typically delineated by predicting the migration of fluid between the reservoir and the lowermost USDW via an open wellbore using predictions from physics-based reservoir simulators. The inherent uncertainty in input parameters used in reservoir modeling therefore affects the accuracy of determining the AoR for a project. Furthermore, the standard analytical approaches for calculating a critical pressure to delineate the risk area yield an infinite AoR for cases where the injection reservoir is overpressured relative to the USDW. A methodology is presented in this paper to better characterize the risk to USDWs while accounting for the uncertainty in reservoir modeling, with an application to a permitted GCS project with an overpressured injection formation, FutureGen 2.0. The methodology is demonstrated using the National Risk Assessment Partnership’s open-source integrated assessment model (NRAP-Open-IAM) to develop a probabilistic estimate of impact risk to USDW quality. CO2 and pressure predictions from the reservoir modeling conducted using the STOMP-CO2 simulator for the FutureGen 2.0 site are used in a NRAP-Open-IAM model with reservoir, wellbore, and aquifer components to: (1) assess the extent of potential leakage into the USDW for the predicted reservoir pressure conditions; (2) evaluate the extent of potential impact using “no-net-degradation” thresholds; and (3) account for uncertainty in reservoir permeabilities.

03 NATURAL GAS↗

Risk-based area of review estimation in overpressured reservoirs to support injection well storage facility permit requirements for CO 2 storage projects

This paper by the Energy & Environmental Research Center presents a workflow and modeling approach for delineating a risk-based area of review (AOR) to support a U.S. Environmental Protection Agency (EPA) Class VI permit for a carbon dioxide (CO 2 ) storage project. The approach combines semianalytical solutions for estimating formation fluid leakage through a hypothetical leaky wellbore with the results of numerical reservoir simulations to define the AOR. The modeling utilizes 1) semianalytical solutions from the peer-reviewed literature for formation fluid leakage through abandoned wellbores by Raven (1990) and Avci (1994), 2) a FORTRAN model compiled and described in Cihan et al. (2011, 2012) called ASLMA (Analytical Solution for Leakage in Multilayered Aquifers), and 3) a computational framework for estimating a risk-based AOR first proposed by Oldenburg et al. (2014, 2016). Therefore, the approach builds upon well-established research and underlying hydrogeological principles that have been upheld for nearly three decades. Moreover, the ASLMA model has been broadly applied to an array of storage projects. The work presented herein extends these earlier works using a custom wrapper written in the software environment, R (R Core Team, 2020), which was developed to perform multiple runs of the ASLMA model using given ranges for one or more input parameters. In addition, the current work simulates the pressure buildup within the storage reservoir in response to CO 2 injection using a compositional simulator to better accommodate the temporospatial evolution of pressure buildup within the storage reservoir that is more accurately modeled using a heterogeneous geologic model and a compositional simulator that accounts for the multiphase interactions. The workflow is demonstrated using a case study for a 180,000-metric-ton-per-year storage project located in the PCOR (Plains CO 2 Reduction) Partnership region. For the storage project evaluated here, under the scenario where the leaky wellbore is open to a saline aquifer (thief zone) between the overlying seal (cap rock) and the underground sources of drinking water (USDW), the risk-based AOR essentially collapses to the areal extent of the CO 2 plume in the storage reservoir because the pressure buildup in the storage reservoir beyond the CO 2 plume is insufficient to drive formation fluids up a hypothetical leaky wellbore into the USDW. However, even under the conservative assumption that the leaky wellbore is not open to a thief zone, beyond the areal extent of the CO 2 plume, the incremental leakage is less than 400 m 3 over 20 years, which represents ~0.0001% or less of the total volume of water contained within the USDW rock volume. As discussed in the text, the threshold criterion for defining the risk-based AOR is site-specific and should be informed by the results of the sensitivity analysis and available site characterization data. The approach outlined in this paper is designed to be protective of USDWs and, therefore, comply with the Safe Drinking Water Act requirements and provisions for the U.S. EPA Class VI Underground Injection Control (UIC) Program (Class VI Rule) and North Dakota Administrative Code Chapter 43-05-01.

54 ENVIRONMENTAL SCIENCES↗

Potential Chemical Impacts of Subsurface CO 2 : An Integrated Experimental and Numerical Assessment for a Case Study of the Ogallala Aquifer

Leakage from geologic CO 2 sequestration (GCS) reservoirs to overlying underground sources of drinking water (USDW) is a tangible risk. This study is an integrated assessment that combines column experiments and reactive transport simulations of sediments sampled from the Ogallala aquifer above an active commercial-scale GCS site (the Farnsworth Unit in northern Texas). Experimental and simulation results suggest that carbonate mineral (calcite and dolomite) dissolution is the most significant reaction following CO 2 intrusion, and is also the dominant source of trace metal release. Cation exchange is another key mechanism controlling trace metal release by cation interference. Most of the trace metals, including Ba, Sr, As, Pb, and Zn, show a short-term release and quickly drop to the baseline values, suggesting low risk to the overlying USDW quality. Other trace metals, such as Mn and U, exhibit a tangible increase of their concentrations in the beginning, and drop to a higher level compared to the baseline, which may become a potential concern of long-term USDW quality change with CO2introduction. This study provides a comprehensive example of combining laboratory experiments and simulations for assessment of CO 2 -sediment interactions with combined release mechanisms in shallow groundwater aquifers. Data presented here provides useful insights for quantitative risk assessment and effective public education regarding CO 2 geological sequestration, and trace metal reactive transport studies in shallow groundwater aquifers.

54 ENVIRONMENTAL SCIENCES↗

Assessment of the Area of Review and Leakage Impact for Site 7 using the NRAP-IAM-CCS Tool, Northern Michigan Basin-CarbonSAFE Phase 1 Pre-Feasibility Study

U.S. Environmental Protection Agency’s (EPA’s) Class VI regulations require owners or operators of carbon storage projects to determine an Area of Review (AoR) representative of project risk to underground sources of drinking water (USDWs). The AoR is an estimate of the project footprint and is used to develop monitoring plans to ensure protection of USDWs. In this syudy, the NRAP-IAM-CS software tool was applied to estimate the AoR and the leakage potential of legacy wells located within the AoR to impact groundwater quality at a carbon storage screening site for the NMB-CS, Phase 1 project. The NRAP-IAM-CS is a science-based toolset developed by the U.S. Department of Energy for quantitative risk assessment of geologic sequestration of carbon dioxide (CO 2 ) (Pawar et al., 2016). The toolset adopts a stochastic approach in which predictions include site uncertainties using storage reservoir, leakage scenario, and shallow groundwater impact reduced order models (ROMs). Risk-based analysis done using the NRAP-IAM-CS yielded an AoR that was comparable to estimates defined by the critical pressure needed move fluid from the reservoir to the overlying USDW through an open wellbore. The risk-based AoR was slightly smaller than that based on the critical pressure (234 km 2 compared to 269 km 2 ), because small fluxes did not impact groundwater quality. Leakage from two legacy wells located within the AoR should not impact groundwater quality over the 30-year injection period. Legacy Well 1 penetrates the simulated CO 2 plume and would require a permeability of 5 x 10 -12 m 2 (~5 Darcy) to impact groundwater quality after about 20 years of injection. Legacy Well 2 falls outside of the CO 2 plume footprint, where reservoir pressures are too small to generate large enough leakage flux to change groundwater quality even with well permeabilities as high as 5 x 10 -11 m 2 (~50 Darcy). This work represents one of the first applications of the NRAP toolset for the screening of potential CO 2 storage sites. The toolset provides a risk-based method of evaluating the AoR and the impact of CO 2 or brine leakage through legacy wells. The following recommendations will strengthen the use of probabilistic assessments for site selection and permitting of Class VI CO 2 injection wells.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Southeast Carbon Sequestration Partnership (SECARB) Phase III Anthropogenic Test at Citronelle Field, Mobile Co., AL Surface and Shallow Subsurface Monitoring

The Southeast Carbon Sequestration Partnership Phase III Anthropogenic Test at Citronelle Field is one of the United States’ largest demonstrations of CO 2 capture, transportation, injection, storage and monitoring using CO 2 derived from a coal-fired electric generating unit. This report summarizes the background and initial injection phase groundwater and soil flux monitoring results. The purpose of the groundwater monitoring program, as prescribed in the Underground Injection Control (UIC) permits is to assure that the project’s activities do not harm Underground Sources of Drinking Water (USDWs). In particular, the objective of the program is to monitor for the release of injected CO2 into groundwater aquifers at the project site. Three shallow USDW monitoring wells were installed as part of the groundwater monitoring program. In addition, a water supply well located near the project’s deep characterization well was utilized for monitoring. Seventeen metals, general chemistry and field parameters (e.g. pH, specific conductance, turbidity) were sampled three times prior to injection and quarterly during the injection period to date. Changes in groundwater geochemistry potentially attributable to a release of carbon dioxide into the USDW from the injection activities are decreasing pH and increasing TIC. The change in pH may also accompany the mobilization of certain metals within the groundwater, but the changes are likely site-specific, based on the natural aquifer mineralogy (Wilkin and Diguilio, 2010). At this time, no downward trends for pH and increasing trends for TIC have been statistically determined in the monitor wells. Valid detections exceeding both the UIC discharge limit and the range of background concentrations observed as of the N=11 event include: Exceedance of the UIC permit discharge limit of manganese at D-9-7 MW-2S and D-9-9 MW-1, and exceedance of the UIC permit discharge limit of iron at D-9-9 MW-1. In addition, a statistically significant increase of barium and manganese has been observed at D-9-9 MW-1. However, Additional lines of evidence (namely, expected shifts in TIC or pH, per the research cited above) to interpret the cause (e.g., potential carbon dioxide influence) of the statistically determined exceedances and/or increases are absent at this time. Quarterly groundwater sampling and analysis will continue throughout the project. The UIC permit requires that soil CO 2 flux shall be monitored at the land surface at the injection site and at nearby locations. Twelve locations were chosen for surveys including a mix of near wellbore and offset locations. To date, 24 surveys have taken place with 12 occurring prior to the onset of injection operations in August 2012. Soil CO 2 flux appears to positively covary with soil temperature. A notably high soil CO 2 flux value (21 µmol/m 2 /sec) was observed from the D-9-9 #2 chamber location during sampling event #24 (9/24/2014). As a result of this finding, the frequency of soil CO 2 flux monitoring events will be increased to twice-monthly until this anomaly can be confirmed or determined to be an outlier. Soil CO 2 flux monitoring will continue for the duration of the project.

01 COAL, LIGNITE, AND PEAT↗

Chemical Impacts of Potential CO2 and Brine Leakage on Groundwater Quality with Quantitative Risk Assessment: A Case Study of the Farnsworth Unit

Potential leakage of reservoir fluids is considered a key risk factor for geologic CO2 sequestration (GCS), with concerns of their chemical impacts on the quality of overlying underground sources of drinking water (USDWs). Effective risk assessment provides useful information to guide GCS activities for protecting USDWs. In this study, we present a quantified risk assessment case study of an active commercial-scale CO2-enhanced oil recovery (CO2-EOR) and sequestration field, the Farnsworth Unit (FWU). Specific objectives of this study include: (1) to quantify potential risks of CO2 and brine leakage to the overlying USDW quality with response surface methodology (RSM); and (2) to identify water chemistry indicators for early detection criteria. Results suggest that trace metals (e.g., arsenic and selenium) are less likely to become a risk due to their adsorption onto clay minerals; no-impact thresholds based on site monitoring data could be a preferable reference for early groundwater quality evaluation; and pH is suggested as an indicator for early detection of a leakage. This study may provide quantitative insight for monitoring strategies on GCS sites to enhance the safety of long-term CO2 sequestration.

58 GEOSCIENCES↗

Geologic carbon sequestration injection wells in overpressured storage reservoirs: estimating area of review

The Area of Review (AoR) under the US Environmental Protection Agency's (EPA) Class VI CO 2 injection permit is defined as the region surrounding the geologic carbon sequestration (GCS) project where underground sources of drinking water (USDWs) may be endangered. Estimation of the AoR is based on the calculated reservoir pressurization due to CO 2 injection and the associated potential to lift saline water into potable groundwater aquifers through open flow paths (e.g. wells) assuming the system is hydrostatic. In cases where the storage reservoirs are not initially hydrostatic, and in particular where they are overpressured, AoR estimation methods need to be altered. Here in this paper, we present and apply an approach to evaluating potential endangerment of USDW based on comparing brine leakage through a hypothetical open flow path in a no-injection scenario and brine leakage in a CO 2 -injection scenario. We present six possible ways to normalize injection-related leakage relative to no-injection leakage. We calculate leakage using semi-analytical solutions for single-phase flow and model reservoir pressurization and flow up (single) leaky wells located progressively farther from the injection well. For an example case of relative overpressure and using an injection-rate-based approach, results show 50-60% larger open-well-leakage rates for wells located at 2 km and 10% increase for wells located at 10 km from the injection well relative to the no-injection case. If total brine leakage is considered, the results depend strongly on the assumed pre-injection to post-injection time frames and on the methods of normalization used to calculate incremental leakage.

54 ENVIRONMENTAL SCIENCES↗

Underground sources of drinking water chemistry changes in response to potential CO 2 leakage

The purpose of this study was to quantify changes to underground sources of drinking water (USDW) quality in response to potential CO 2 leakage from geologic CO 2 sequestration (GCS) reservoirs. Here, the developed a framework of combined laboratory experiments and reactive transport simulations and used this framework to evaluate the Ogallala aquifer overlying the Farnsworth Unit (FWU), an active GCS site, as a case study. Using chemical reaction parameters obtained from laboratory experiments and numerical simulations, site-specific mechanisms of CO 2 -water-sediment interactions at the USDW aquifer were interpreted. Long-term risks of potential CO 2 leakage were then evaluated with field-scale numerical models using the regional hydrogeological characteristics and reaction parameters obtained from our experiments and simulations. Results suggest that carbonate mineral impurity and cation exchange are key mechanisms for interactions between CO 2 and the aquifer sediment. Additionally, for a large leakage rate of 0.1 % injection from one leaky well, the leakage plume might impact an area of 300 m in diameter and significantly affect the local water quality by changing pH and cation concentrations (e.g., Zn, Ba and Sr). After leakage ceases, the zone of impacted fluids would not migrate significantly in subsequent decades due to a low regional groundwater flowrate (for this case study). The relatively small area of impact might not be detected in a monitoring well given the broader spacing in a typical field scenario. Effective early leakage detection may require additional tools, e.g., borehole CO 2 movement, four-dimensional seismicity, CO 2 soil flux, samples from deeper aquifers, etc., to ensure effective leakage detection and long-term safety of GCS projects.

58 GEOSCIENCES↗

A risk-based approach to evaluating the Area of Review and leakage risks at CO 2 storage sites

The U.S. Environmental Protection Agency’s Class VI regulations for underground carbon dioxide (CO 2 ) injection require owners and operators of storage projects to identify (1) an Area of Review (AoR) that represents the region that may be affected by the injection of CO 2 , and (2) leakage risks that might impact the quality of underground sources of drinking water (USDWs). This article describes how such risks can be determined by accounting for the physical and chemical properties of all components of a CO 2 storage site using elements of the National Risk Assessment Partnership Integrated Assessment Model for Carbon Storage (NRAP-IAM-CS). For this work we used practical data from three sites that are part of two CarbonSAFE (Carbon Storage Assurance Facility Enterprise) projects to demonstrate application of the NRAP-IAM-CS toolset to determine project risk areas. NRAP-IAM-CS was used to estimate the project risk area that could represent the AoR and the impact of leakage through legacy wells to overlying drinking waters at these candidate CO 2 storage sites. Our study shows that risk to USDWs is minimal despite (1) the presence of multiple legacy wells at these sites where the AoR approximates the maximum extent of injected CO 2 or (2) the presence of a much larger AoR approximating the pressure front caused by the injection of CO 2 .

54 ENVIRONMENTAL SCIENCES↗

Arsenic mobilization in shallow aquifers due to CO 2 intrusion from storage reservoirs

We developed an integrated framework of combined batch experiments and reactive transport simulations to quantify water-rock-CO 2 interactions and arsenic (As) mobilization responses to CO 2 and/or saline water leakage into USDWs. Experimental and simulation results suggest that when CO 2 is introduced, pH drops immediately that initiates release of As from clay minerals. Calcite dissolution can increase pH slightly and cause As re-adsorption. Thus, the mineralogy of the USDW is ultimately a determining factor of arsenic fate and transport. Salient results suggest that: (1) As desorption/adsorption from/onto clay minerals is the major reaction controlling its mobilization, and clay minerals could mitigate As mobilization with surface complexation reactions; (2) dissolution of available calcite plays a critical role in buffering pH; (3) high salinity in general hinders As release from minerals; and (4) the magnitude and quantitative uncertainty of As mobilization are predicated on the values of reaction rates and surface area of calcite, adsorption surface areas and equilibrium constants of clay minerals, and cation exchange capacity. Results of this study are intended to improve ability to quantify risks associated with potential leakage of reservoir fluids into shallow aquifers, in particular the possible environmental impacts of As mobilization at carbon sequestration sites.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermodynamic Properties of Aqueous Carbonate Species and Solid Carbonate Phases of Selected Trace Elements pertinent to Drinking Water Standards of the U.S. Environmental Protection Agency

This report contains a series of tables summarizing the thermodynamic properties of aqueous carbonate complexes and solid carbonate phases of the following elements: arsenic (As), barium (Ba), cadmium (Cd), chromium (Cr), cobalt (Co), copper (Cu), iron (Fe), lead (Pb), manganese (Mn), mercury (Hg), nickel (Ni) thallium (Tl), uranium (U) and zinc (Zn). Most of these elements are potentially hazardous as defined by extant primary drinking water standards of the United States Environmental Protection Agency (EPA). The remainder are not considered hazardous, but are either listed by EPA under secondary standards, or because they can adversely affect drinking water quality. Additional tables are included giving the thermodynamic properties for carbonates of the alkali metal and alkali earth elements, sodium (Na), potassium (K), magnesium (Mg), calcium (Ca), and strontium (Sr), because of their value in developing correlative models to estimate the thermodynamic properties of carbonate minerals for which no such data currently exist. The purpose in creating the tables in this report is to provide future investigators with a convenient source for selecting and tracing the sources of thermodynamic data of the above listed elements for use in modeling their geochemical behavior in “underground sources of drinking water” (USDW). The incentive for doing so lies with a heightened concern over the potential consequences of the proposed capture and storage of carbon dioxide (CO2) generated by fossil fuel fired power plants in deep subsurface reservoirs. If CO2 were to leak from such reservoirs, it could migrate upward and contaminate USDWs with undesirable, but undetermined, consequences to water quality. The EPA, Office of Research and Development, through an Interagency Agreement with the U.S. Department of Energy at the Lawrence Berkeley National Laboratory, funded the preparation of this report.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Report on Subsurface Characterization of the Phase III Anthropogenic Test Project Site (SECARB Phase III Work Product 4.2.1.d)

A test site and anthropogenic carbon dioxide (CO 2 ) source have been selected for a large-scale demonstration of CO 2 separation, capture and sequestration in southwestern Alabama as part of the Southeastern Regional Carbon Sequestration Partnership’s (SECARB) Phase III initiative. The James M. Barry Generating Plant, a major coal-fired power plant in southwestern Alabama, is the selected anthropogenic CO 2 source for the project. The proposed storage test site is located in the Citronelle oil field, which lies at the crest of the Citronelle Dome. The proposed storage site is favorable for deep underground injection of CO 2 . Seismic activity in southwest Alabama is low and the absence of identified faulting in and near the Citronelle oil field indicates that the area provides a structurally stable environment for CO 2 storage operations. The porous and permeable sands of the proposed injection zone, the Paluxy Formation, present a favorable injection reservoir in terms of areal extent and petrophysical characteristics. The proposed confining zone, the Basal Shale of the overlying Washita-Fredericksburg Formation is persistent throughout the Citronelle area and appears to possess the appropriate criteria to act as an effective CO 2 seal. In addition to the Basal Washita-Fredericksburg Shale, secondary overlying confining units including the Middle (Marine) Tuscaloosa Formation, the Selma Group, and the Midway Shale, occur stratigraphically between the injection zone and the base of the lowermost underground source of drinking water (USDW). The Citronelle Dome is an ideal geometry for containment of CO 2 The dome is a subtle, anticlinal structure that contains a broad salt pillow at the core and provides fourway closure. At the test site, subsurface geologic strata, including the proposed injection and confining zones, dip to the east-south-east at about 1.25 degrees. Buoyant CO 2 is expected to migrate up dip towards the crest of the dome, where it will be contained within the structure of the dome. No faulting or significant fracture zones occur within the Dome. A vertical interval of over 8,000 feet with numerous low permeability barriers occurs between the proposed injection zone and the base of the lowermost USDW.

01 COAL, LIGNITE, AND PEAT↗

Southeast Carbon Sequestration Partnership (SECARB) Phase III Anthropogenic Test at Citronelle Field, Mobile Co., AL. Post-Injection Period Reservoir Modeling Report

The Southeast Carbon Sequestration Partnership (SECARB) Anthropogenic Test is a U.S. Department of Energy funded fully integrated carbon capture and storage initiative designed to demonstrate deep underground injection and containment of anthropogenic CO 2 sourced from Alabama Power’s Plant Barry. From August 20, 2012 to September 1, 2014, a total of 114,014 metric tonnes of CO 2 were transported via pipeline from Plant Barry and stored in a saline aquifer under a portion of the Citronelle Field operated by Denbury Onshore, LLC near Citronelle, Alabama. A major component of this project was to test and develop techniques to monitor, verify and account (MVA) for the CO 2 stored in the aquifer by the project. A suite of technologies were applied and developed to demonstrate non-endangerment of underground sources of drinking water (USDW’s) and to ensure that CO2 does not migrate out of intended zones within the subsurface. This involved several levels of monitoring: 1) Surface monitoring, 2) shallow groundwater monitoring, 3) deep reservoir monitoring and experimental MVA activities. Numerical models were developed to determine the project’s Area of Review (AoR) and to investigate the simulated advancement of the CO 2 plume through the subsurface aquifer for 30 years after the end of injection. An initial baseline area of review of 1,700 ft. was established. The key results demonstrating non-endangerment of USDW’s are presented.

01 COAL, LIGNITE, AND PEAT↗

Storage Field Development Plan: One Earth Energy

This Storage Field Development plan presents the Storage Complex characterization results, construction, monitoring, and operational plans, and costs associated with the proposed One Earth Sequestration Carbon Capture and Storage (OES-CCS) site in McLean County, Illinois, near Gibson City. The proposed storage complex, known as the Mt. Simon Storage Complex, comprises the Cambrian Mt. Simon Sandstone reservoir and the primary seal, the Cambrian Eau Claire Formation. The lowermost Underground Source of Drinking Water (USDW) identified for the site is the Ordovician St. Peter Sandstone. Geologic characterization of the Mt. Simon Storage Complex at the OES-CCS site was performed by the Illinois Storage Corridor CarbonSAFE Phase III project, which also prepared and submitted three UIC Class VI applications to construct three injection wells; the permit applications were submitted and are in the federal EPA review process. A characterization well, OEE #1, was drilled to collect site-specific data. These data were analyzed and used to develop the UIC Class VI applications. The OEE #1 well will be converted to an in-zone monitoring (IZM) well for the injection phase. The proposed buildout for the OES-CCS site includes (1) three injection wells (OES #1, OES #2, and OES #3), (2) two IZM wells, (3) two above confining zone (ACZ) monitoring wells, one of which will be used to monitor the lowermost USDW, (4) capture and compression facilities, and (5) transportation facilities, i.e., pipelines. A pre-operational testing program was proposed in the Class VI permit application and will be employed at the site pending approval. Additional pre-injection (baseline), syn-injection, and post-injection monitoring and site care procedures will be followed by OES to ensure that injection activities are protective of human health and the environment. Injection is scheduled to begin in 2025, distributed across the three injection wells in accordance with the permit operating conditions. One Earth Sequestration intends to inject up to 90 million tonnes of CO 2 over a period of approximately 20 years. Injection will begin at approximately 0.5 million tonnes of CO 2 annually and ramp up to a maximum of 4.5 million tonnes annually. Daily injection rates are expected to range from 1,400 to 1,500 tonnes per day initially and reach a maximum of approximately 4,225 tonnes per day, depending on site geology and injectivity at each injection well location, and CO 2 availability. The costs associated with the OES-CCS project include pre-operational costs (e. g. additional seismic data acquisition and well drilling), capture and transportation facility and equipment costs, predicted field operating expenditures (OpEx), and decommissioning and post-injection site care (PISC) costs. The risks associated with project activities, such as site construction, injection operations, and verification of secure storage were evaluated, and mitigation strategies proposed to alleviate those risks.

09 BIOMASS FUELS↗

Delineating Area of Review in a System with Pre-injection Relative Overpressure

The Class VI permit application for geologic carbon sequestration (GCS) requires delineation of an area of review (AoR), defined as the region surrounding the (GCS) project where underground sources of drinking water (USDWs) may be endangered. The methods for estimating AoR under the Class VI regulation were developed assuming that GCS reservoirs would be in hydrostatic equilibrium with overlying aquifers. Here we develop and apply an approach to estimating AoR for sites with preinjection relative overpressure for which standard AoR estimation methods produces an infinite AoR. The approach we take is to compare brine leakage through a hypothetical open flow path in the base-case scenario (no-injection) to the incrementally larger leakage that would occur in the CO 2 -injection case. To estimate AoR by this method, we used semi-analytical solutions to single-phase flow equations to model reservoir pressurization and flow up (single) leaky wells located at progressively greater distances from the injection well. We found that the incrementally larger flow rates for hypothetical leaky wells located 6 km and 4 km from the injection well are ~20% and 30% greater, respectively, than hypothetical baseline leakage rates. If total brine leakage is considered, the results depend strongly on how the incremental increase in total leakage is calculated, varying from a few percent to up to 40% greater (at most at early time) than base-case total leakage.

58 GEOSCIENCES↗

A simulation study of carbon storage with active reservoir management

As part of the Integrated Midcontinent Stacked Carbon Storage Hub (IMSCS-Hub) project led by Battelle Memorial Institute, a study was conducted to determine the feasibility of storing carbon dioxide (CO 2 ) in the stacked saline rock formations of the Sleepy Hollow Field (SHF), located in Red Willow County, southern Nebraska. A series of CO 2 injection simulation scenarios, with and without active reservoir management (ARM; brine extraction), were evaluated to investigate the feasibility of storing 50+ million tonnes (Mt) of CO 2 . The results indicated CO 2 injection combined with ARM may enable permanent storage of 50+ Mt of CO 2 . The area of review (AOR), the area in which underground sources of drinking water (USDWs) might be endangered during CO 2 injection, was assessed for the simulation scenarios. In comparison to a case without ARM, brine extraction resulted in a much smaller AOR, covering an area of 42 square miles (108.8 km 2 ), roughly one-fourth the size of an AOR resulting from CO 2 injection without ARM. Our findings, presented in this paper, indicate that CO 2 injection with ARM can improve the CO 2 storage capacity of a geologic storage complex up to 100% while also reduce the rate of pressure buildup in the subsurface, resulting in a 75% reduction in AOR. This may help in lowering carbon capture and storage project costs, risks, and effort needed to meet monitoring requirements for a storage project.

54 ENVIRONMENTAL SCIENCES↗