Engineering PapersSearch

SEARCH · Engineering Papers

Results for “urban heat island”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Using Satellite Surface Temperature Data to Monitor Urban Heat Island

Exposure to heat is a growing concern nationwide. Temperatures can be elevated in cities compared to surrounding rural areas, referred to as an “urban heat island” (UHI) effect, which is intensified during heat waves. The lack of dense networks of air temperature measurements results in few studies on urban heat. Now, a vast amount of high spatial and temporal satellite data on land surface temperature is available. We identified satellite datasets with the longest surface temperature records but different spatial and temporal resolutions: Landsat (1985-current, biweekly at 60 m and 100 m spatial resolution) and the Moderate Resolution Imaging Spectroradiometer (MODIS) data from the Terra and Aqua satellites (2000-current, daily at 1 km spatial resolution). We investigated how satellites with different spatial and temporal resolutions detect UHI effects differently. We hypothesized that 1) a dataset’s spatial resolution impacts the precision of detected UHIs spatially, since high spatial resolution Landsat data better captures spatial variability in temperature, and 2) daily surface temperature data can detect temporal patterns of UHIs and heatwave frequencies. We analyzed Landsat and MODIS satellite data in the Washington, D.C. and Baltimore region. We found that Landsat describes higher spatial variability of the UHI effect than MODIS data. However, MODIS data shows more consistent seasonal surface temperature patterns than Landsat when compared to in situ air temperature measurements. MODIS data was also able to consistently measure the frequency of heat waves. This study demonstrates the value of NASA satellite data for urban heat and climate change studies.

landsat

WRF-Comfort: simulating microscale variability in outdoor heat stress at the city scale with a mesoscale model

Abstract. Urban overheating and its ongoing exacerbation due to global warming and urban development lead to increased exposure to urban heat and increased thermal discomfort and heat stress. To quantify thermal stress, specific indices have been proposed that depend on air temperature, mean radiant temperature (MRT), wind speed, and relative humidity. While temperature and humidity vary on scales of hundreds of meters, MRT and wind speed are strongly affected by individual buildings and trees and vary on the meter scale. Therefore, most numerical thermal comfort studies apply microscale models to limited spatial domains (commonly representing urban neighborhoods with building blocks) with resolutions on the order of 1 m and a few hours of simulation. This prevents the analysis of the impact of city-scale adaptation and/or mitigation strategies on thermal stress and comfort. To solve this problem, we develop a methodology to estimate thermal stress indicators and their subgrid variability in mesoscale models – here applied to the multilayer urban canopy parameterization BEP-BEM within the Weather Research and Forecasting (WRF) model. The new scheme (consisting of three main steps) can readily assess intra-neighborhood-scale heat stress distributions across whole cities and for timescales of minutes to years. The first key component of the approach is the estimation of MRT in several locations within streets for different street orientations. Second, mean wind speed and its subgrid variability are downscaled as a function of the local urban morphology based on relations derived from a set of microscale LES and RANS simulations across a wide range of realistic and idealized urban morphologies. Lastly, we compute the distributions of two thermal stress indices for each grid square, combining all the subgrid values of MRT, wind speed, air temperature, and absolute humidity. From these distributions, we quantify the high and low tails of the heat stress distribution in each grid square across the city, representing the thermal diversity experienced in street canyons. In this contribution, we present the core methodology as well as simulation results for Madrid (Spain), which illustrate strong differences between heat stress indices and common heat metrics like air or surface temperature both across the city and over the diurnal cycle.

Geology

NASA Space Launch System Artemis I & II Post Flight Ascent Aerothermal Environments Overview

Since 2011 the Aerosciences Branch/EV33 at NASA Marshall Space Flight Center has been involved with the development of ascent external aerothermal environments for the NASA Space Launch System (SLS) Block 1 launch vehicle for the purposes of supporting thermal analysis and the design of thermal protection systems. The SLS Block 1 Artemis I and II launch vehicles successfully launched from Pad39B at NASA Kennedy Space Center on November 16th, 2022 and April 1st, 2026, respectively. Over 70 aerothermal islands, consisting of over 265 operational instruments captured aerodynamic heating and plume induced environments throughout the launch vehicles. Gauges consisted of calorimeters, radiometers, gas temperature probes, pressure transducers, bi-directional pressure probes and thermocouples. Prior to launch, aerothermal design environment models were generated to predict ascent aerodynamic heating and plume induced environments over a design space that covered a range of vehicle trajectories that varied atmospheric, vehicle performance, and off-nominal, engine-out conditions. Post flight reconstruction models were developed for each flight island using the Day-of-Launch (DOL) Best Equivalent Trajectory (BET) that provided freestream conditions and propulsion system boundary conditions. This paper discusses a summary of the ascent aerothermal environments observed during the flights and the respective modelling approaches and the performance of them through comparisons of flight data and predictions.

aerothermodynamics

Speciation of Transition Metal Dissolution in Electrolyte from Common Cathode Materials

Significant capacity loss has been observed across extended cycling of lithium-ion batteries cycled to high potential. One of the sources of capacity fade is transition metal dissolution from the cathode active material, ion migration through the electrolyte, and deposition on the solid-electrolyte interphase on the anode. While much research has been conducted on the oxidation state of the transition metal in the cathode active material or deposited on the anode, there have been limited investigations of the oxidation state of the transition metal ions dissolved in the electrolyte. Here, in this work, X-ray absorption spectroscopy has been performed on electrolytes extracted from cells built with four different cathode active materials (LiMn 2 O 4 (LMO), LiNi 0.5 Mn 1.5 O 4 (LNMO), LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811), and (x Li 2 MnO 3 *(1-x) LiNi a Mn b Co c O 2 , with a+b+c=1) (LMRNMC)) that were cycled at either high or standard potentials to determine the oxidation state of Mn and Ni in solution. Inductively coupled plasma-mass spectrometry has been performed on the anodes from these cells to determine the concentration of deposited transition metal ions. While transition metal ions were found dissolved in all electrolytes, the oxidation state(s) of Mn and Ni were determined to be dependent on the cathode material and independent of cycling potential.

25 ENERGY STORAGE

Ecohydrology of urban environments

Urban watersheds include a gradient of highly managed to unmanaged ecosystems that vary in vegetation cover, built and natural drainage systems, and impervious cover. A distinct difference to undeveloped ecosystems is the dominance of material and energy import and export, the disruption of natural catenae, the covariation of soils, terrain and canopy conditions. In this chapter, we discuss the distinct characteristics of urban ecohydrology compared to non-urban systems. We also investigate emergent principles of unmanaged watersheds that underscore the promotion of ecohydrological resilience, and the need to abstract and adapt these principles to support the goal-oriented restoration of impaired urban ecosystems.

42 ENGINEERING

Resilience Strategies to Ensure Water Supply Continuity During Extended Grid Outages

The towns of Edgartown, Oak Bluffs and Tisbury, on the island of Martha’s Vineyard, MA, are concerned about the effect of prolonged grid outages on continuity of their water supply. Water pumping stations operated by the water utilities that currently serve each of the towns currently have backup power generation that can support water delivery for up to one week during peak water demand periods. Sandia advised on options to extend water supply to two weeks.

Mammoli, Andrea Alberto [Sandia National Laborator

Change Detection Analysis in Urban and Suburban Areas Using Landsat Thematic Mapper data: Case of Huntsville, Alabama

Two Landsat Thematic Mapper (TM) images, from July 1984 and July 1992, were used to identify land use/cover changes in the urban and suburban fringe of the city of Huntsville, Alabama. Image difference was the technique used to quantify the change between the two dates. The eight-year period showed a 16% change, mainly from agricultural lands to urban areas generated by the settlement of industrial, commercial, and residential areas. Visual analysis of the change map (i.e., difference image) supported this phenomenon by showing that most changes were occurring in the vicinity of the major roads and highways across the city.

Dana Kuan

Spacecraft Fire Safety Predictions using Verified Saffire Model

A model developed using Fire Dynamics Simulator (FDS) that aimed to determine the effect of a fire in a spacecraft was validated by data collected during the Saffire campaign. The model used inlet and outlet temperatures and CO 2 concentrations of the Saffire payload where fire spread was taking place to determine the amount of heat and combustion products that made it into Northrop Grumman’s Cygnus vehicle. The model was then validated using six remote sensors in various places in the vehicle, as well as a far field device (FFD) in the open zenith section that was representative of average vehicle values. The current work focuses on using the model to predict fire safety scenarios. One simulation aimed to determine the fate of HCl, which sticks to surfaces. The model prediction showed that the HCl was removed from the atmosphere rapidly. This compared well against the FFD data in the Saffire VI campaign event where a bottle of 5% HCl was released into the vehicle. An additional simulation where the Environmental Control and Life Support System (ECLSS) was shut off once the FFD reached 5 ppm of HCl showed that HCl stayed in the atmosphere considerably longer. Continuing the simulation with the ECLSS activated and after temperatures returned to their initial conditions, resulted in a rapid removal of HCL similar to that observed in the original HCl release scenario model. Finally, a simulation that used the heat release rate from a lithium-ion battery test to determine the effect it would have on a spacecraft was performed. This simulation used a heat addition rate that is considerably higher than what was determined from the burning of solid fuels in the Saffire campaign and hence produced a non-trivial temperature increase in more locations within the vehicle.

Fire Safety

Helicopter and Urban Air Mobility (UAM) Laboratory Comparison (HULC) Psychoacoustic Test

The Helicopter and Urban Air Mobility (UAM) Laboratory Comparison (HULC) psychoacoustic test was conducted in July 2025 to compare human annoyance responses to noise from UAM vehicles and helicopters. This document provides a literature review, describes the HULC test methodology including stimuli selection and test administration procedures, and presents results from an initial analysis using multilevel statistical modeling. The test utilized 123 sound stimuli from four helicopters and six UAM vehicles across three flight phases (departure, cruise, and approach), presented to 40 subjects in the Exterior Effects Room (EER) at NASA's Langley Research Center. Subjects rated their annoyance on a 0 to 10 scale while imagining hearing these sounds multiple times daily near their homes. Key findings revealed that, at the same A-weighted sound exposure levels, UAM vehicles and helicopters produced similar annoyance responses across all flight phases, with mean differences of only approximately 1 dB and overlapping confidence intervals. However, at equivalent observer distances, UAM vehicles had inherently quieter operations and lower mean annoyance ratings. These results suggest that UAM vehicles and helicopters may be assessed in a similar manner for community noise impact. The quieter noise characteristics of UAM vehicles may provide advantages for operating in communities and integrating into urban environments.

psychoacoustics

Trust-Based Detection and Mitigation of Cyber Attacks in Distributed Cooperative Control of Islanded AC Microgrids

In this study, we address the challenge of detecting and mitigating cyber attacks in the distributed cooperative control of islanded AC microgrids, with a particular focus on detecting False Data Injection Attacks (FDIAs), a significant threat to the Smart Grid (SG). The SG integrates traditional power systems with communication networks, creating a complex system with numerous vulnerable links, making it a prime target for cyber attacks. These attacks can lead to the disclosure of private data, control network failures, and even blackouts. Unlike machine learning-based approaches that require extensive datasets and mathematical models dependent on accurate system modeling, our method is free from such dependencies. To enhance the microgrid’s resilience against these threats, we propose a resilient control algorithm by introducing a novel trustworthiness parameter into the traditional cooperative control algorithm. Our method evaluates the trustworthiness of distributed energy resources (DERs) based on their voltage measurements and exchanged information, using Kullback-Leibler (KL) divergence to dynamically adjust control actions. We validated our approach through simulations on both the IEEE-34 bus feeder system with eight DERs and a larger microgrid with twenty-two DERs. The results demonstrated a detection accuracy of around 100%, with millisecond range mitigation time, ensuring rapid system recovery. Additionally, our method improved system stability by up to almost 100% under attack scenarios, showcasing its effectiveness in promptly detecting attacks and maintaining system resilience. These findings highlight the potential of our approach to enhance the security and stability of microgrid systems in the face of cyber threats.

Computer Science

Green Era Anaerobic Digester

Green Era Educational NFP constructed and commissioned the Green Era Renewable Energy & Urban Farming Campus in Chicago’s Auburn Gresham neighborhood. The project transformed a long-vacant brownfield site into a commercial-scale anaerobic digestion facility that converts food waste into renewable natural gas and nutrient-rich material for agricultural use. The facility can process up to 80,000 wet tons of food waste annually and supports approximately 15 permanent jobs while advancing food waste diversion, renewable energy production, nutrient recovery and community revitalization.

03 NATURAL GAS

Socio-Techno-Economic Feasibility of Deep Geothermal with EGS for Residential District Heating in the Northeastern United States

In this paper, we present socio-techno-economic simulation results for enhanced geothermal system (EGS) district heating systems in the northeastern United States. We applied the geospatial Distributed Geothermal Market Demand (dGeo) tool coupled with GEOPHIRES to evaluate the feasibility of geothermal deep direct-use, utilizing EGS reservoirs for providing residential heating with district heating systems. The results were combined with JEDI results to assess social impacts. Simulation results assuming doublet EGS reservoirs with target production temperature of 80 degrees C and newly constructed district heating systems indicate a wide range in system levelized cost of heat (LCOH) values ranging from ~$15/MMBtu to over $1,000/MMBtu, with most the attractive regions urban areas with high total thermal demand and high thermal demand density. We estimate about 60 GWth in potential installed capacity with LCOH values under $50/MMBtu and 100 GWth in potential capacity with LCOH values under $100/MMBtu, respectively.

15 GEOTHERMAL ENERGY

Battery Evaluation Profiles for X-57 and Future Urban Electric Aircraft

Battery energy density is one of the most critical design parameters for sizing all-electric aircraft, however it’s easily overestimated. Establishing the effective, usable energy density is confused by varying degrees of margin needed to account for structural and thermal management between different cell chemistry and pack designs. Therefore, a better methodology is needed to fairly compare emerging battery technologies for electric aircraft. Currently, there is a loss of critical information when vehicle trade studies are performed using “nominal” published cell-level performance metrics. Aircraft power demands rarely match these nominal power profiles, and aircraft designers lack the ability to accurately simulate the battery performance and temperature off-nominally unless the battery chemistry is well established. Conversely, battery suppliers have no generalized reference cases to publish more realistic performance metrics. This can lead to poor assumptions, such as aircraft studies assuming a fixed discharge efficiency of a battery, when in reality the usable energy in a pack is dependent on the power and thermal profile. Information needed to properly assess weight penalties for thermal management is also typically poorly characterized when assessing candidate batteries. This paper serves to better inform battery development, and similarly, provide aircraft designers with more realistic assumptions for applying knockdown margins in their designs. Detailed power and thermal performance estimates are provided, which provide a starting point for sizing power and thermal budgets using experimentally derived battery models. Results show that the X-57 battery-to-shaft efficiency is 77.3% for a particular optimized mission. Considering a 25% reserve on the battery capacity, this means that only roughly half of the original 55.3kWh ‘nominal’ pack energy can be converted to useful work during a mission. Further estimates on a clean-sheet VTOL optimization show an average 82.7% battery-to-shaft efficiency, using 98% peak efficiency inverters and 97.4% peak efficiency motors. Although higher battery efficiencies are possible, the resulting weight penalty negates improvement in vehicle performance. These trade-offs and resulting power profiles are provided as a starting point to better assess future battery designs.

Battery

Battery Evaluation Profiles for X-57 and Future Urban Electric Aircraft

Battery energy density is one of the most critical design parameters for sizing all-electric aircraft, however it’s easily overestimated. Establishing the effective, usable energy density is confused by varying degrees of margin needed to account for structural and thermal management between different cell chemistry and pack designs. Therefore, a better methodology is needed to fairly compare emerging battery technologies for electric aircraft. Currently, there is a loss of critical information when vehicle trade studies are performed using “nominal” published cell-level performance metrics. Aircraft power demands rarely match these nominal power profiles, and aircraft designers lack the ability to accurately simulate the battery performance and temperature off-nominally unless the battery chemistry is well established. Conversely, battery suppliers have no generalized reference cases to publish more realistic performance metrics. This can lead to poor assumptions, such as aircraft studies assuming a fixed discharge efficiency of a battery, when in reality the usable energy in a pack is dependent on the power and thermal profile. Information needed to properly assess weight penalties for thermal management is also typically poorly characterized when assessing candidate batteries. This paper serves to better inform battery development, and similarly, provide aircraft designers with more realistic assumptions for applying knockdown margins in their designs. Detailed power and thermal performance estimates are provided, which provide a starting point for sizing power and thermal budgets using experimentally derived battery models. Results show that the X-57 battery-to-shaft efficiency is 77.3% for a particular optimized mission. Considering a 25% reserve on the battery capacity, this means that only roughly half of the original 55.3kWh ‘nominal’ pack energy can be converted to useful work during a mission. Further estimates on a clean-sheet VTOL optimization show an average 82.7% battery-to-shaft efficiency, using 98% peak efficiency inverters and 97.4% peak efficiency motors. Although higher battery efficiencies are possible, the resulting weight penalty negates improvement in vehicle performance. These trade-offs and resulting power profiles are provided as a starting point to better assess future battery designs.

Battery Electric Aircraft

Early Fire Detection System for Partial and Low Gravity Environments

We present preliminary results on the development of a fire detection system for partial and low gravity environments. A significant challenge is the design of a system with a low false alarm rate. The detection system therefore has to discriminate between combustion particles, cabin, and lunar dust. Aerosol properties are measured and cross referenced to the target detectors at the Gases and Aerosols from Smoldering Polymers (GASP) Laboratory located at the NASA Glenn Research Center. A computational fluid dynamics plume model is also employed to determine the smoke transport properties of the targeted habitats.

Early fire detectioin