Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “universal spare”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transformative Technology for FLASH Radiation Therapy

The general concept of radiation therapy used in conventional cancer treatment is to increase the therapeutic index by creating a physical dose differential between tumors and normal tissues through precision dose targeting, image guidance, and radiation beams that deliver a radiation dose with high conformality, e.g., protons and ions. However, the treatment and cure are still limited by normal tissue radiation toxicity, with the corresponding side effects. A fundamentally different paradigm for increasing the therapeutic index of radiation therapy has emerged recently, supported by preclinical research, and based on the FLASH radiation effect. FLASH radiation therapy (FLASH-RT) is an ultra-high-dose-rate delivery of a therapeutic radiation dose within a fraction of a second. Experimental studies have shown that normal tissues seem to be universally spared at these high dose rates, whereas tumors are not. While dose delivery conditions to achieve a FLASH effect are not yet fully characterized, it is currently estimated that doses delivered in less than 200 ms produce normal-tissue-sparing effects, yet effectively kill tumor cells. Despite a great opportunity, there are many technical challenges for the accelerator community to create the required dose rates with novel compact accelerators to ensure the safe delivery of FLASH radiation beams.

43 PARTICLE ACCELERATORS↗

Transformative Technology for FLASH Radiation Therapy: A Snowmass 2021 White Paper

Conventional cancer therapies include surgery, radiation therapy, chemotherapy, and, more recently, immunotherapy. These modalities are often combined to improve the therapeutic index. The general concept of radiation therapy is to increase the therapeutic index by creating a physical dose differential between tumors and normal tissues through precision dose targeting, image guidance, and high radiation beams that deliver radiation dose with high conformality, e.g., protons and ions. However, treatment and cure are still limited by normal tissue radiation toxicity, with many patients experiencing acute and long-term side effects. Recently, however, a fundamentally different paradigm for increasing the therapeutic index of radiation therapy has emerged, supported by preclinical research, and based on the FLASH radiation effect. FLASH radiation therapy (FLASH-RT) is an ultra-high dose-rate delivery of a therapeutic radiation dose within a fraction of a second. Experimental studies have shown that normal tissues seem to be universally spared at these high dose rates, whereas tumors are not. The dose delivery conditions are not yet fully characterized. Still, it is currently estimated that large doses of 10 Gy or more delivered in 200 ms or less produce normal tissue sparing effects yet effectively kill tumor cells. There is a great opportunity, but also many technical challenges, for the accelerator community to create the required dose rates with novel and compact accelerators to ensure the safe delivery of FLASH radiation beams.

43 PARTICLE ACCELERATORS↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

As we know, power transformers are the most critical asset of the transmission network. Although highly reliable, they still can fail prematurely or ultimately retire at the end of their service life. In today’s design practices, transformers are tailored to their specific application and therefore cannot replace each other unless identical. Additionally, they provide minimal support to the grid operation and therefore limit the grid flexibility and resiliency when facing severe conditions. In this presentation, we will introduce the concept of flexible power transformer and demonstrate how one single unit can serve as a spare to multiple units in a given fleet, allow to control the power flow between transformers or lines operating in parallel and ultimately be used to limit subsequent faults in transmission lines. We will also introduce the world’s first prototype in operation, a 60MVA, 165kV flexible autotransformer.

flexible power transformer, autotransformer, varia↗

Flexible Transformers for Resilient and Adaptable Power Systems

This paper presents experience with grid ready flexible transformer unit, which is in service for two years without any difficulty. Transformer unit is capable of changing short circuit impedance on load and it is equipped with state-of-the-art monitoring system.

field validation↗

FLEXIBLE POWER TRANSFORMERS TO IMPROVE RESILIENCY OF TRANSMISSION NETWORKS

For decades, transformer flexibility of operation has been limited to adjustable voltage ratio and, in some cases, several ratings with staged cooling. Transformers reconnectable to multiple voltage ratings have been primarily applied as emergency replacements. Other versions of “flexible transformers” were developed for continuous, long-term operation at specific sites, with application limited to large utilities. A new technology that supports today’s power systems adaptability requirements has been developed to provide not only voltage and power rating flexibility, but also an adjustable short-circuit impedance. This last, unique feature allows for a closer match to actual system operational requirements and could be used in the future to enhance resiliency and improve dynamic control of electrical grids. While the solution’s fundamentals have already been introduced in several technical forums, the intention of this article is to focus on the potential benefits of this new type of transformer and share the deployment experience of a full-scale prototype that has been in operation in a major U.S. utility since 2021

flexible transformer, resilient grid, variable lea↗

Identification of KLHL12 Ligands Using Fragment-Based Methods

Targeted protein degradation can be induced by recruiting a protein of interest to an E3 ligase, resulting in its ubiquitination and subsequent proteasome-mediated degradation. However, only a small number of E3 ligases have been utilized for degradation. Expansion of the repertoire of useful E3 ligases via the identification of ligands to those ligases could broaden the scope and applicability of the degradation paradigm. We have identified KLHL12 as an E3 ligase with higher expression in cancer over normal tissues. We report here the use of NMR-based screening to identify fragments that bind to KLHL12, and X-ray structures of a fragment hit bound to KLHL12. Using this structural information, we optimized the hits, leading to the first reported small molecules that bind to KLHL12 with submicromolar affinity. Derivatives of these compounds may be useful for the construction of PROTACs to selectively degrade protein targets in tumors while sparing normal cells.

Amines↗

Structure-function analysis of the FCRL5–IgG1 Fc complex reveals an unappreciated pathway for B cell modulation by Fc-attenuated IgG

The Fc region of therapeutic IgG antibodies is often engineered to remove or “silence” Fc effector functions, but it remains unclear whether these mutations eliminate all Fc-mediated effector activity. Human Fc receptor-like 5 (FCRL5/FcRH5) is a low-affinity IgG Fc receptor expressed on B cells and is an actively pursued antibody target in multiple myeloma. Here, we show that common Fc function-silencing mutations do not impair FCRL5-mediated activity and therefore attenuate, rather than eliminate, Fc effector function. The crystal structure of the FCRL5-IgG1 Fc complex, solved at 3.4 Å resolution, revealed that FCRL5 binds IgG1 Fc in a 1:1 complex through a binding mode distinct from that of classical Fcγ receptors, explaining why mutations that attenuate Fc effector function spare FCRL5 binding. Fc-engineered antibodies that selectively engage FCRL5 inhibited B cell receptor-induced Ca 2+ flux in FCRL5-expressing B cells. These findings demonstrate that Fc-attenuated therapeutic IgG retains the ability to engage FCRL5, identifying an unappreciated pathway for B cell modulation.

Herpers, Bart M. [Department of Biomedical Enginee↗

Target Selection and Sample Characterization for the DESI LOW-Z Secondary Target Program

Abstract We introduce the DESI LOW- Z Secondary Target Survey, which combines the wide-area capabilities of the Dark Energy Spectroscopic Instrument (DESI) with an efficient, low-redshift target selection method. Our selection consists of a set of color and surface brightness cuts, combined with modern machine-learning methods, to target low-redshift dwarf galaxies ( z < 0.03) between 19 < r < 21 with high completeness. We employ a convolutional neural network (CNN) to select high-priority targets. The LOW- Z survey has already obtained over 22,000 redshifts of dwarf galaxies ( M * < 10 9 M ⊙ ), comparable to the number of dwarf galaxies discovered in the Sloan Digital Sky Survey DR8 and GAMA. As a spare fiber survey, LOW- Z currently receives fiber allocation for just ∼50% of its targets. However, we estimate that our selection is highly complete: for galaxies at z < 0.03 within our magnitude limits, we achieve better than 95% completeness with ∼1% efficiency using catalog-level photometric cuts. We also demonstrate that our CNN selections z < 0.03 galaxies from the photometric cuts subsample at least 10 times more efficiently while maintaining high completeness. The full 5 yr DESI program will expand the LOW- Z sample, densely mapping the low-redshift Universe, providing an unprecedented sample of dwarf galaxies, and providing critical information about how to pursue effective and efficient low-redshift surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Small-molecule modulation of β-arrestins

β-Arrestins are multifunctional regulators of G-protein-coupled receptor (GPCR) signalling and orchestrate diverse downstream signalling events and physiological responses across the GPCR superfamily. Although GPCR pharmacology has advanced to target orthosteric and allosteric sites, as well as G proteins and GPCR kinases, direct chemical tools to modulate β-arrestin activities have remained conspicuously absent. Here we report the identification of small-molecule inhibitors that selectively target β-arrestins and delineate their mechanism of action through integrated pharmacological, biochemical, biophysical and structural analyses. These inhibitors disrupt β-arrestin engagement with agonist-activated GPCRs, impairing desensitization, internalization and β-arrestin-dependent physiological functions while sparing G protein–receptor coupling. Cryo-electron microscopy, molecular dynamics simulations and structure-guided mutagenesis reveal that one modulator, Cmpd-5, engages a pocket within the central crest of β-arrestin1 formed by the middle, C and lariat loops, a critical receptor-binding interface, stabilizing a distinct conformation that is incompatible with full β-arrestin–receptor engagement. Together, these findings establish a mechanistic framework for β-arrestin modulation, reveal a novel allosteric site for structure-based drug design, and open new avenues for transducer-targeted, pathway-specific GPCR therapeutic agents.

Kahsai, Alem W. [Duke University, Durham, NC (Unit↗

Locally Confined Polysulfide-Reactive Electrolytes for Shuttle-Free Sodium–Sulfur Batteries

Sodium-sulfur batteries promise high-energy-density and sustainable electrochemical energy storage but suffer from uncontrolled polysulfides dissolution and high sodium reactivity. These challenges fundamentally originate from poor electrolyte-electrode compatibility. Current electrolyte research inadequately addresses the trade-off between minimal polysulfides solvation and stabilizing sodium interfaces. Here, we present a locally-confined polysulfide-reactive electrolyte strategy that mediates the polysulfide dissolution dynamics and sodium stability by leveraging an electrophilic solvating species with a localized high-concentration electrolyte. This design enables shuttle-free cell operation by synergistically restricting the global solvating power of the electrolyte through intermolecular interactions and locally scavenging sparingly dissolved polysulfides via electrolyte electrophilicity. The precisely confined surface reaction facilitates a protective cathode-electrolyte interface, realizing a quasi-solid-state sulfur conversion in our liquid ether-based electrolyte, which crucially avoids crossover-induced catastrophic sodium-metal degradation. The proposed electrolyte demonstrates long-term cycling of high-mass-loading sulfur cathodes (> 3 mg S cm −2 with commercial carbon host and 70 wt% sulfur content), which afford 710 mA h g −1 over 400 cycles in coin cells and steady pouch cell operation over 180 cycles. Furthermore, this work establishes a scalable electrolyte design protocol that regulates the reaction chemistry of highly reactive electrodes, offering a pathway toward sustainable renewable energy storage.

25 ENERGY STORAGE↗

Characterizing hole trap production due to proton irradiation in germanium cross-strip detectors

We present an investigation into the effects of high-energy proton damage on charge trapping in germanium cross-strip detectors with the goal of accomplishing three important measurements. First, we calibrated and characterized the spectral resolution of a spare COSI-balloon detector in order to determine the effects of intrinsic trapping, finding that electron trapping due to impurities dominates over hole trapping in the undamaged detector. Second, we performed two rounds of proton irradiation of the detector in order to quantify, for the first time, the rate at which charge traps are produced by proton irradiation. We find that the product of the hole trap density and cross-sectional area, [nσ] h , follows a linear relationship with the proton fluence, F p , with a slope of (5.4 ± 0.4) x 10 -11 cm/p + . Third, by utilizing our measurements of physical trapping parameters, we performed calibrations which corrected for the effects of trapping and mitigated degradation to the spectral resolution of the detector.

79 ASTRONOMY AND ASTROPHYSICS↗

The DESI Transients Survey: Legacy Classifications and Methodology

We present the first systematic spectroscopic observations of extragalactic transients from the Dark Energy Spectroscopic Instrument (DESI), as part of the DESI Transients Survey program. With 5,000 fibers and an ${\sim} 8$ deg$^2$ field of view, we exploit DESI as a machine for the discovery and classification of transients. We present transient classifications from archival DESI data in Data Releases 1 and 2, relying on a combination of a secondary target program and serendipitous observations. We also present observations from the first 6 months of the DESI spare fiber program dedicated to transients. The program is run in coordination with a dedicated DECam time-domain survey, serving as a pathfinder for what we will be able to achieve in conjunction with the Rubin Observatory Legacy Survey of Space and Time (LSST). We classify over 250 transients, of which the majority were previously unclassified. The sample comprises thermonuclear and core-collapse supernovae and tidal disruption events (TDEs), including a TDE observed before its discovery in imaging. We demonstrate DESI's ability to classify a population of faint transients down to $r\sim 22.5$ mag during main survey operations, with negligible impacts on DESI's main observations.

Hall, Xander J. [Carnegie Mellon U.] (ORCID:000000↗