Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “undulators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Initial performances of first undulator-based hard x-ray beamlines of NSLS-II compared to simulations

Commissioning of the first X-ray beamlines of NSLS-II included detailed measurements of spectral and spatial distributions of the radiation at different locations of the beamlines, from front-ends to sample positions. Additionally, comparison of some of these measurement results with high-accuracy calculations of synchrotron (undulator) emission and wavefront propagation through X-ray transport optics, performed using SRW code, is presented.

47 OTHER INSTRUMENTATION↗

Magnet system optimization for segmented adaptive-gap in-vacuum undulator

Segmented Adaptive Gap in-vacuum Undulator (SAGU), in which different segments have different gaps and periods, promises a considerable spectral performance gain over a conventional undulator with uniform gap and period. According to calculations, this gain can be comparable to the gain achievable with a superior undulator technology (e.g. a room-temperature in-vacuum hybrid SAGU would perform as a cryo-cooled hybrid in-vacuum undulator with uniform gap and period). However, for reaching the high spectral performance, SAGU magnetic design has to include compensation of kicks experienced by the electron beam at segment junctions because of different deflection parameter values in the segments. Here we show that such compensation to large extent can be accomplished by using a passive correction, however, simple correction coils are nevertheless required as well to reach perfect compensation over a whole SAGU tuning range. Magnetic optimizations performed with Radia code, and the resulting undulator radiation spectra calculated using SRW code, demonstrating a possibility of nearly perfect correction, are presented.

47 OTHER INSTRUMENTATION↗

Parametric Optimization of Undulators for NSLS-II Project Beamlines

General optimization procedure, computation methods used, and the obtained optimal parameters of undulators for the NSLS-II project beamlines are reported. The optimization starts with high-accuracy calculation of undulator magnetic fields, using Radia magnetostatics code, for a large set of periods and vertical gaps of a given undulator type, given magnetic materials and a scalable magnet geometry. From the resulting magnetic fields, a sub-set of undulator periods and the corresponding vertical gaps, providing the required low-energy cut-off values of spectral harmonics for each particular beamline, is determined. In parallel, from the same Radia undulator models, angular magnetic kick maps are calculated, and the insertion device effect on electron beam is simulated using Tracy-2 tracking code based on symplectic integrator. After these simulations, magnet parameters are fine-tuned and the maximal acceptable undulator lengths are determined for different straight sections, as functions of minimal gap and with due regard for the electron beam vertical ''stay clear'' constraint in the case of in-vacuum undulators. Finally, the optimal undulator period and length are determined as the values providing maximal spectral flux among the pre-selected undulator cases, already satisfying the requirements concerning the harmonic cut-off values and the effect on electron beam.

43 PARTICLE ACCELERATORS↗

Heat Treatment Studies of Nb3Sn Wires for Superconducting Planar Undulators

A project aiming to fabricate a full-length 2.8-m long Nb 3Sn superconducting undulator for the storage ring was started last year at the ANL APS. These Nb 3 Sn undulators operate at a maximum magnetic field on the conductor of about 5 T. To address instabilities at this field, two Nb 3 Sn wires with small subelement size were used. Specifically, Restacked Rod Processed wires of 0.6mmin diameter and with 144 and 150 superconducting subelements respectively, over 169 total. The equivalent subelement diameter, DS, of thesewires is35 mu m. At these smallDS values, the critical current density is known to deteriorate, and the Residual Resistivity Ratio is very sensitive to heat treatment. A delicate balance has therefore to be found to obtain parameters within operation specifications. In this paper we showperformance results from different heat treatments.

critical current density↗

3D Columnar Phase of Stacked Short DNA Organized by Coherent Membrane Undulations

We report on the discovery of a new organized lipid-nucleic acid phase upon intercalation of blunt duplexes of short DNA (sDNA) within cationic multilayer fluid membranes. End-to-end interactions between sDNA leads to columnar stacks. At high membrane charge density, with the inter-sDNA column spacing (d sDNA ) comparable but larger than the diameter of sDNA, a 2D columnar phase (i.e., a 2D smectic) is found similar to the phase in cationic liposome-DNA complexes with long lambda-phage DNA. Remarkably, with increasing d sDNA as the membrane charge density is lowered, a transition is observed to a 3D columnar phase of stacked sDNA. This occurs even though direct DNA–DNA electrostatic interactions across layers are screened by diffusing cationic lipids near the phosphate groups of sDNA. Softening of the membrane bending rigidity (κ), which further promotes membrane undulations, significantly enhances the 3D columnar phase. These observations are consistent with a model by Schiessel and Aranda-Espinoza where local membrane undulations, due to electrostatically induced membrane wrapping around sDNA columns, phase lock from layer-to-layer, thereby precipitating coherent “crystal-like” undulations coupled to sDNA columns with long-range position and orientation order. The finding that this new phase is stable at large d sDNA and enhanced with decreasing κ is further supportive of the model where the elastic cost of membrane deformation per unit area around sDNA columns (∝ κh 2 /d sDNA 4 , h 2 = sum of square of amplitudes of the inner and outer monolayer undulations) is strongly reduced relative to the favorable electrostatic attractions of partially wrapped membrane around sDNA columns. Here, the findings have broad implications in the design of membrane-mediated assembly of functional nanoparticles in 3D.

59 BASIC BIOLOGICAL SCIENCES↗

The E166 Experiment: Undulator-Based Production of Polarized Positrons

A proof-of-principle experiment has been carried out in the Final Focus Test Beam (FFTB) at SLAC to demonstrate production of polarized positrons in a manner suitable for implementation at the ILC. A helical undulator of 2.54 mm period and 1-m length produced circularly polarized photons of first harmonic endpoint energy of 8 MeV when traversed by a 46.6 GeV electron beam. The polarized photons were converted to polarized positrons in a 0.2-radiation-length tungsten target. The polarization of these positrons was measured at several energies, with a peak value in excess of 80%, by transmission polarimetry of photons obtained on reconversion of the positrons in a second tungsten target.

43 PARTICLE ACCELERATORS↗

Development of short-period Nb{sub 3}Sn superconducting undulators for the APS.

Superconducting undulators (SCUs) with a period of 14.5 mm are under development for the Advanced Photon Source (APS) using Nb{sub 3}Sn superconductors. The initial goal is to install a SCU with a 19- to 29-keV tuning range for the first harmonic photon energy. The design of the SCU assembly includes the interface with the beam chamber as an integral part of the assembly. A four-period Nb{sub 3}Sn half SCU was fabricated and tested. After a number of quenches, the SCU was charged to an engineering current density of 1.92 kA/mm{sup 2} in the coil pack. This corresponds to a peak field of 1.08 T on the beam axis with a pole gap of 8.5 mm. The achieved current density was approximately 90% of the engineering critical current density for the design calculations. With an operating current density of 1.6 kA/mm{sup 2}, the SCU will operate at a peak field of 0.95 T with some degree of stability.

43 PARTICLE ACCELERATORS↗

Reply to “Comment on ‘Dynamics of Phospholipid Membranes beyond Thermal Undulation’”

Recently, Granek postulated a connection of the Brochard-Lennon (BL) “red blood cell” mode with the short time relaxation of liposomes observed by neutron spin echo (NSE) spectroscopy. The experimental observations themselves clearly exclude this BL mode as an explanation. Here, we emphasize that it is an inherent behavior of lipids detectable with different techniques.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamics of Phospholipid Membranes beyond Thermal Undulations

Here, we investigated the molecular dynamics of unilamellar liposomes by neutron spin echo spectroscopy. We report the first experimental evidence of a short-range motion at the length scale of the size of the headgroup of a lipid. The associated mean squared displacement shows a t 0.26 dependence in the pico- to nanosecond region that indicates another process beyond the predictions of the Zilman–Granek (ZG) model (t 0.66 ) and translational diffusion (t 1 ). A comparison with theory shows that the observed low exponent is associated with a non-Gaussian transient trapping of lipid molecules in a local area and supports the continuous time random walk model. The analysis of the mean squared displacement leads to the important conclusion that the friction at the interface between water and liposomes plays a minor role. Center of mass diffusion of liposomes and transient trapping of lipids define the range in which the ZG model can be applied to analyze membrane fluctuations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vertically polarizing undulator with the dynamic compensation of magnetic forces for the next generation of light sources

A short prototype (847-mm-long) of an Insertion Device (ID) with the dynamic compensation of ID magnetic forces has been designed, built, and tested at the Advanced Photon Source (APS) of the Argonne National Laboratory. The ID magnetic forces were compensated by the set of conical springs placed along the ID strongback. Well-controlled exponential characteristics of conical springs permitted a very close fit to the ID magnetic forces. Several effects related to the imperfections of actual springs, their mounting and tuning, and how these factors affect the prototype performance has been studied. Finally, series of tests to determine the accuracy and reproducibility of the ID magnetic gap settings have been carried out. Based on the magnetic measurements of the ID B{sub eff}, it has been demonstrated that the magnetic gaps within an operating range were controlled accurately and reproducibly within ±1 μm. Successful tests of this ID prototype led to the design of a 3-m long device based on the same concept. The 3-m long prototype is currently under construction. It represents R and D efforts by the APS toward APS Upgrade Project goals as well as the future generation of IDs for the Linac Coherent Light Source (LCLS)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗