Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ultrasound”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Ultrasound-Assisted Nonthermal, Nonequilibrium Separation of Organic Molecules from Their Binary Aqueous Solutions: Effect of Solute Properties on Separation

The separation of organic molecules in downstream processes, such as distillation, plays a vital role in biobased chemical production. A comprehensive study was performed here using ultrasonic energy to separate 11 organic molecules from their binary aqueous solutions under nonthermal, nonequilibrium, and phase-change free conditions. A batch sonoseparator with a three-stage mist collection unit allowed direct analysis of ultrasound-generated mist with an HPLC/GC and differentiation and quantification of the vapor and mist. The results showed that the alcohols (1-butanol, ethanol, 1-propanol, and methanol) and acetone were enriched in the ultrasound-generated mist with enrichment ratios of 3.2–5. On the other hand, ethylene glycol, glycerol, γ-valerolactone (GVL), glucose, and sucrose were diluted with dilution ratios in the range of 2.04–15.7 in the mist and vapor generated by ultrasound (or concentrated in the bulk solution). No enrichment nor dilution of acetic acid was observed. The role of various physicochemical parameters such as dynamic viscosity, surface tension, Henry’s law of solubility constant, vapor pressure, and octanol–water partition coefficient in the enrichment was examined. Furthermore, the hydrophobicity of the organic molecules represented by the octanol–water partition coefficient was found to play a crucial role in determining the separation characteristics of the molecules in ultrasound-generated mist and vapor.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A broadband wavelet implementation for rapid ultrasound pulse-echo time-of-flight measurements

A broadband wavelet approach to ultrasonic pulse-echo time-of-flight measurements is described. The broadband approach significantly reduces the time required for frequency-dependent pulse-echo measurements, enabling studies of dynamic systems ranging from biological systems to solid-state phase transitions. The described broadband approach is demonstrated in parallel with the more traditional frequency stepping approach to perform ultrasound time-of-flight measurements inside a large volume Paris-Edinburgh press in-situ at a synchrotron source. The broadband wavelet data acquisition process was found to be 1-2 orders of magnitude faster than the steppedfrequency approach, with no compromise in data quality or determined results.

47 OTHER INSTRUMENTATION↗

Systems and methods for plane-wave and fan-beam ultrasound-waveform tomography

A method for plane-wave or fan-beam ultrasound tomography includes: controlling, by a processor, a multi-channel ultrasound array controller to control a linear ultrasound transducer array to emit plane-wave or fan-beam ultrasound into a biological tissue, the linear ultrasound transducer array including a plurality of transducers; receiving, by the processor, plane-wave or fan-beam ultrasound waveform data from the transducers, the plane-wave or fan-beam ultrasound waveform data including reflections of the plane-wave or fan-beam ultrasound from the biological tissue; computing, by the processor, a synthetic ultrasound-waveform inversion from the received plane-wave or fan-beam ultrasound waveform data; and computing, by the processor, an image of the biological tissue from the synthetic ultrasound-waveform inversion.

Huang, Lianjie↗

On the Bandwidth and Beam Profile Characteristics of a Simple Low-Frequency Collimated Ultrasound Beam Source

We numerically investigate the bandwidth and collimation characteristics of ultrasound beams generated by a simple collimated ultrasound beam source that consists of a piezoelectric disk operated near its radial mode resonances. We simulate the ultrasound beam generated in a fluid medium as a function of the excitation frequency for two cases: (1) free piezoelectric disk that corresponds to zero-traction along the lateral edge and (2) fixed piezoelectric disk that corresponds to zero-displacement along the lateral edge. We present and discuss the physical mechanism underpinning the frequency-dependent collimation and bandwidth properties of the ultrasound beams. We observe that the collimated beam generated by the free disk repeatedly lengthens/shortens and also extends/retracts sidelobes with increasing frequency. Alternatively, fixing the piezoelectric disk results in a consistent beam profile shape across a broad range of frequencies. This facilitates generating broadband signals such as a Gaussian pulse or chirp, which are common in ultrasound imaging. Thus, the fixed piezoelectric disk finds application as a collimated ultrasound beam source in a wide range of applications including medical ultrasound imaging, scanning acoustic microscopy, sonar detection, and other nondestructive ultrasound inspection techniques.

47 OTHER INSTRUMENTATION↗

Characterization of the acoustic cavitation in ionic liquids in a horn-type ultrasound reactor

Most ultrasound-based processes root in empirical approaches. Because nearly all advances have been conducted in aqueous systems, there exists a paucity of information on sonoprocessing in other solvents, particularly ionic liquids (ILs). In this work, we modelled an ultrasonic horn-type sonoreactor and investigated the effects of ultrasound power, sonotrode immersion depth, and solvent’s thermodynamic properties on acoustic cavitation in nine imidazolium-based and three pyrrolidinium-based ILs. The model accounts for bubbles, acoustic impedance mismatch at interfaces, and treats the ILs as incompressible, Newtonian, and saturated with argon. Following a statistical analysis of the simulation results, we determined that viscosity and ultrasound input power are the most significant variables affecting the intensity of the acoustic pressure field (P), the volume of cavitation zones (V), and the magnitude of the maximum acoustic streaming surface velocity (u). V and u increase with the increase of ultrasound input power and the decrease in viscosity, whereas the magnitude of negative P decreases as ultrasound power and viscosity increase. Probe immersion depth positively correlates with V, but its impact on P and u is insignificant. 1-alkyl-3-methylimidazolium-based ILs yielded the largest V and the fastest acoustic jets – 0.77cm 3 and 24.4ms -1 for 1-ethyl-3-methylimidazolium chloride at 60W. 1-methyl-3-(3-sulfopropyl)-imidazolium-based ILs generated the smallest V and lowest u – 0.17cm 3 and 1.7ms -1 for 1-methyl-3-(3-sulfopropyl)-imidazolium p-toluene sulfonate at 20W. Sonochemiluminescence experiments validated the model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An extended focused assessment with sonography in trauma ultrasound tissue-mimicking phantom for developing automated diagnostic technologies

Medical imaging-based triage is critical for ensuring medical treatment is timely and prioritized. However, without proper image collection and interpretation, triage decisions can be hard to make. While automation approaches can enhance these triage applications, tissue phantoms must be developed to train and mature these novel technologies. Here, we have developed a tissue phantom modeling the ultrasound views imaged during the enhanced focused assessment with sonography in trauma exam (eFAST). The tissue phantom utilized synthetic clear ballistic gel with carveouts in the abdomen and rib cage corresponding to the various eFAST scan points. Various approaches were taken to simulate proper physiology without injuries present or to mimic pneumothorax, hemothorax, or abdominal hemorrhage at multiple locations in the torso. Multiple ultrasound imaging systems were used to acquire ultrasound scans with or without injury present and were used to train deep learning image classification predictive models. Performance of the artificial intelligent (AI) models trained in this study achieved over 97% accuracy for each eFAST scan site. We used a previously trained AI model for pneumothorax which achieved 74% accuracy in blind predictions for images collected with the novel eFAST tissue phantom. Grad-CAM heat map overlays for the predictions identified that the AI models were tracking the area of interest for each scan point in the tissue phantom. Overall, the eFAST tissue phantom ultrasound scans resembled human images and were successful in training AI models. Tissue phantoms are critical first steps in troubleshooting and developing medical imaging automation technologies for this application that can accelerate the widespread use of ultrasound imaging for emergency triage.

60 APPLIED LIFE SCIENCES↗

Performance Comparison of Object Detection Networks for Shrapnel Identification in Ultrasound Images

Ultrasound imaging is a critical tool for triaging and diagnosing subjects but only if images can be properly interpreted. Unfortunately, in remote or military medicine situations, the expertise to interpret images can be lacking. Machine-learning image interpretation models that are explainable to the end user and deployable in real time with ultrasound equipment have the potential to solve this problem. We have previously shown how a YOLOv3 (You Only Look Once) object detection algorithm can be used for tracking shrapnel, artery, vein, and nerve fiber bundle features in a tissue phantom. However, real-time implementation of an object detection model requires optimizing model inference time. Here, we compare the performance of five different object detection deep-learning models with varying architectures and trainable parameters to determine which model is most suitable for this shrapnel-tracking ultrasound image application. We used a dataset of more than 16,000 ultrasound images from gelatin tissue phantoms containing artery, vein, nerve fiber, and shrapnel features for training and evaluating each model. Every object detection model surpassed 0.85 mean average precision except for the detection transformer model. Overall, the YOLOv7tiny model had the higher mean average precision and quickest inference time, making it the obvious model choice for this ultrasound imaging application. Other object detection models were overfitting the data as was determined by lower testing performance compared with higher training performance. In summary, the YOLOv7tiny object detection model had the best mean average precision and inference time and was selected as optimal for this application. Next steps will implement this object detection algorithm for real-time applications, an important next step in translating AI models for emergency and military medicine.

60 APPLIED LIFE SCIENCES↗

A Novel Continuous Ultrasound-Assisted Leaching Process for Rare Earth Element Extraction: Environmental and Economic Assessment

Rare earth elements (REEs) make up integral components in personal electronics, healthcare instrumentation, and modern energy technologies. REE leaching with organic acids is an environmentally friendly alternative to traditional extraction methods. Our previous study demonstrated that batch ultrasound-assisted organic acid leaching of REEs can significantly decrease environmental impacts compared to traditional bioleaching. The batch method is limited to small volumes and is unsuitable for industrial implementation. This study proposes a novel approach to increase reaction volume using a continuous ultrasound-assisted organic acid leaching method. Laboratory experiments showed that continuous ultrasound-assisted leaching increased the leaching rate (µg/h) 11.3–24.5 times compared to our previously reported batch method. Techno-economic analysis estimates the cost of the continuous approach using commercially purchased organic acids is $\$$9465/kg of extracted REEs and $\$$4325/kg of extracted REEs, using gluconic acid and citric acid, respectively. The sensitivity analysis reveals that substituting commercially purchased organic acids with microbially produced biolixiviant can reduce the process cost by approximately 99% while minimally increasing energy consumption. Environmental assessment shows that most of the emissions stemmed from the energy required to power the ultrasound reactor. We concluded that increased leaching capacity using a continuous ultrasound-assisted approach is feasible, but process modifications are needed to reduce the environmental impact.

54 - ENVIRONMENTAL SCIENCES/GLOBAL CLIMATE CHANGE ↗

Ultrasound Characterization of Plastic Bonded Explosives With Varied Binder Content and Density

Advanced explosive formulations and methods of production require rapid characterization for both processes and materials. Here, we present results for ultrasound characterization of a plastic bonded explosive (PBX) formulation as a function of binder weight percent and pressing density using through-transmission sound speed measurements. The explosive in this study was composed of 1,3,5-triamino-2,4,6-trinitrobenzene (TATB) combined with the fluoropolymer binder Kynar Ultraflex B. Binder content ranged from 2.6 wt.% to 11.5 wt.% with associated explosive formulation densities from 1.69 g/cc to 1.89 g/cc. We find linear and nonlinear changes in longitudinal and shear sound speeds, peak frequencies, and measured elastic properties for the different PBX formulations. These measured changes can differentiate the tested formulations, highlighting the potential for ultrasound as a nondestructive characterization method for newly-formulated PBXs. We also demonstrate through-transmission measurements using different coupling media and present results from an ultrasound technique called resonant ultrasound spectroscopy (RUS). Both transmission and RUS approaches may allow for rapid and even automated characterization of PBX components suitable for high-throughput manufacturing operations.

Engineering↗

(Phospho)Proteomic dataset of ischemia- and ultrasound- stimulated mouse cardiac endothelial cells in vitro

Cardiac endothelial cells respond to both ischemia and therapeutic ultrasound; the proteomic changes underlying these responses are unknown. This data article provides raw and processed data resulting from our global, unbiased phosphoproteomics investigation conducted on primary mouse cardiac endothelial cells exposed to ischemia (2-hour oxygen glucose deprivation) and ultrasound (250 kHz, 1.2 MPa) in vitro [1]. Proteins were extracted from cell lysates and enriched phosphopeptides were analyzed with a high mass accuracy liquid chromatrography (LC) - tandem mass spectrometry (MS/MS) proteomic platform, yielding multiple alterations in both total protein levels and phosphorylation events in response to ischemic injury and ultrasound. This dataset can be used as a reference for future studies on the cardiac endothelial response to ischemia and the mechanistic underpinnings of the cellular response to ultrasound, with the potential to yield clinically relevant therapeutic targets.

59 BASIC BIOLOGICAL SCIENCES↗

Avoiding thermal runaway in lithium-ion batteries using ultrasound detection of early failure mechanisms

Thermal runaway leading to catastrophic failure has slowed the adoption of lithium-ion batteries, highlighting the need for early warning systems. In this work, ultrasound is used to detect physical changes in 0.950 Ah Li-ion battery cells by inducing conditions associated with thermal runaway. Ultrasound signal features are extracted as the batteries are cycled under baseline conditions and subsequently subjected to constant current and voltage overcharges. Two conditions identifying failure are defined: a warning to detect the start of overcharge and an emergency stop (E-stop), to immediately take the battery out of service. Using changes in ultrasound signal features, consistent warning and stopping classifications are applied to all failure experiments. On average, a warning notification was issued after 15% of the overcharge time and an E-stop was triggered after 35% of total overcharge duration before failure. Further testing suggests that it is possible to avoid thermal runaway by reacting to intermediate, warning notifications prior to an immediate E-stop. In other words, not only can detection derived by ultrasound identify battery failure before a catastrophic event, but can also provide early, actionable warnings so that overcharges can be detected and corrected quickly enough so the battery does not need to be decommissioned.

25 ENERGY STORAGE↗

A Bayesian inferencing framework for ultrasound wave speed measurements in metal additive manufacturing

Process-related changes during metal additive manufacturing introduce microstructural variability in the material properties of printed parts, directly affecting component reliability. Accurate estimation of these property variations with part performance are essential for quality assurance. Ultrasound testing offers a non-destructive means to estimate mechanical properties and detect defects; however, conventional analysis methods often neglect the influence of microstructural variability, limiting their effectiveness. Here, this research presents a Bayesian inference technique for quantifying wave speed uncertainty from ultrasound measurements of metal additive manufactured parts. By integrating prior ultrasound data with a Bayesian model, the proposed approach generates posterior density estimates of wave speed that systematically account for manufacturing-induced variability and uncertainty. The novelty of this research lies in applying a Bayesian framework to analyze experimental ultrasound measurements within the context of metal additive manufacturing variability. The method enhances the accuracy of wave speed estimation by 64%, defect position by 50% and increases confidence associated with wave speed variance by 30% across different porosity levels, thereby providing a robust foundation for improved decision-making and increased reliability in additively manufactured components.

Additive manufacturing↗

Design and testing of ultrasound probe adapters for a robotic imaging platform

Medical imaging-based triage is a critical tool for emergency medicine in both civilian and military settings. Ultrasound imaging can be used to rapidly identify free fluid in abdominal and thoracic cavities which could necessitate immediate surgical intervention. However, proper ultrasound image capture requires a skilled ultrasonography technician who is likely unavailable at the point of injury where resources are limited. Instead, robotics and computer vision technology can simplify image acquisition. As a first step towards this larger goal, here, we focus on the development of prototypes for ultrasound probe securement using a robotics platform. The ability of four probe adapter technologies to precisely capture images at anatomical locations, repeatedly, and with different ultrasound transducer types were evaluated across more than five scoring criteria. Testing demonstrated two of the adapters outperformed the traditional robot gripper and manual image capture, with a compact, rotating design compatible with wireless imaging technology being most suitable for use at the point of injury. Next steps will integrate the robotic platform with computer vision and deep learning image interpretation models to automate image capture and diagnosis. This will lower the skill threshold needed for medical imaging-based triage, enabling this procedure to be available at or near the point of injury.

47 OTHER INSTRUMENTATION↗

Deep learning models for interpretation of point of care ultrasound in military working dogs

Introduction: Military working dogs (MWDs) are essential for military operations in a wide range of missions. With this pivotal role, MWDs can become casualties requiring specialized veterinary care that may not always be available far forward on the battlefield. Some injuries such as pneumothorax, hemothorax, or abdominal hemorrhage can be diagnosed using point of care ultrasound (POCUS) such as the Global FAST® exam. This presents a unique opportunity for artificial intelligence (AI) to aid in the interpretation of ultrasound images. In this article, deep learning classification neural networks were developed for POCUS assessment in MWDs. Methods: Images were collected in five MWDs under general anesthesia or deep sedation for all scan points in the Global FAST® exam. For representative injuries, a cadaver model was used from which positive and negative injury images were captured. A total of 327 ultrasound clips were captured and split across scan points for training three different AI network architectures: MobileNetV2, DarkNet-19, and ShrapML. Gradient class activation mapping (GradCAM) overlays were generated for representative images to better explain AI predictions. Results: Performance of AI models reached over 82% accuracy for all scan points. The model with the highest performance was trained with the MobileNetV2 network for the cystocolic scan point achieving 99.8% accuracy. Across all trained networks the diaphragmatic hepatorenal scan point had the best overall performance. However, GradCAM overlays showed that the models with highest accuracy, like MobileNetV2, were not always identifying relevant features. Conversely, the GradCAM heatmaps for ShrapML show general agreement with regions most indicative of fluid accumulation. Discussion: Overall, the AI models developed can automate POCUS predictions in MWDs. Preliminarily, ShrapML had the strongest performance and prediction rate paired with accurately tracking fluid accumulation sites, making it the most suitable option for eventual real-time deployment with ultrasound systems. Further integration of this technology with imaging technologies will expand use of POCUS-based triage of MWDs.

59 BASIC BIOLOGICAL SCIENCES↗

Liquid metallic laser ultrasound transducer for high-temperature applications

This study aims to investigate a laser ultrasound (LUS) transducer for high-temperature (>100 °C) applications. For decades, many researchers have investigated efficient LUS transducers, yet studies on laser ultrasound transducers capable of performing at the high-temperature condition are rarely found in the literature. Most current LUS transducers still utilize a polymer-based composite material, that is, not stable at varying temperature conditions. This study introduces a liquid metallic (LM) LUS transducer that utilizes field's metal, which has a high thermal expansion (~3 × 10 -4 K -1 ). We hypothesized that such a high thermal expansion of the liquid metal can effectively produce laser-generated ultrasound waves, substituting for conventional polymer-based transducers. A numerical simulation predicted that the LM LUS transducer would produce higher LUS intensity (~22 dB) than that without the LUS transducer. Experiment results confirmed that the LM transducer effectively intensifies the ultrasound wave signals, obtaining a signal-to-noise gain over 30 dB. Moreover, the transducer was found capable of transmitting detectable wave packets in relatively high-temperature conditions (~400 °C), while conventional candle soot nanoparticle-polydimethylsiloxane could not perform stably at these elevated temperatures. The investigations introduced in this article are scientifically significant since we demonstrated the engineering feasibility of liquid metallic materials for LUS transducers.

47 OTHER INSTRUMENTATION↗

Fiber coupled laser ultrasound system using a single mode hollow core fiber for excitation laser: Theory and demonstration for on-machine thickness gauging

Laser ultrasound (LU) is a technique that uses a pump laser and a probe laser to optically generate and detect elastic waves in a material. Despite its advantages over traditional contact transducer-based ultrasound, industrial adoption has been limited by complex optical setups and the inability of multi-mode fibers to deliver a stable Gaussian profile for the pump laser. Here, we report a fully fiber-coupled thermoelastic LU system that uses an anti-resonant hollow-core single-mode fiber to deliver 1 mJ nanosecond pulses of 1064 nm light, while preserving the fundamental Gaussian mode (pump laser). When combined with a fiber-coupled interferometer (probe laser), a small, flexible, and environmentally robust sensor capable of optically generating and detecting high frequency broadband ultrasound is realized. We demonstrate such an LU system implemented in situ on a four-axis precision lathe. High-resolution thickness gauging is performed, before and after precision cutting, by exciting and measuring a zero-group velocity guided wave mode. The measurements are verified with ex-situ traceable coordinate measuring machine data. Mean absolute deviations of 0.1%, of nominal thickness, before cutting, and 0.2% and 0.3%, after stepped and tapered cuts, respectively, are reported. A theoretical background for thermoelastic ultrasound generation in an elastic waveguide is also presented. Attention is given to the effect of the pump laser profile on wave generation to elucidate the importance of using single-mode laser light. The fiber-coupled system demonstrated is well-suited for use in scientific and engineering sensing applications and facilitates the adoption of LU for industrial non-destructive testing.

Engineering↗

Model-Based Reconstruction for Multi-Frequency Collimated Beam Ultrasound Systems

Collimated beam ultrasound systems are a technology for imaging inside multi-layered structures such as geothermal wells. These systems work by using a collimated narrow-band ultrasound transmitter that can penetrate through multiple layers of heterogeneous material. A series of measurements can then be made at multiple transmit frequencies. However, commonly used reconstruction algorithms such as Synthetic Aperture Focusing Technique (SAFT) tend to produce poor quality reconstructions for these systems both because they do not model collimated beam systems and they do not jointly reconstruct the multiple frequencies. Here, in this article, we propose a multi-frequency ultrasound model-based iterative reconstruction (UMBIR) algorithm designed for multi-frequency collimated beam ultrasound systems. The combined system targets reflective imaging of heterogeneous, multi-layered structures. For each transmitted frequency band, we introduce a physics-based forward model to accurately account for the propagation of the collimated narrow-band ultrasonic beam through the multi-layered media. We then show how the joint multi-frequency UMBIR reconstruction can be computed by modeling the direct arrival signals, detector noise, and incorporating a spatially varying image prior. Results using both simulated and experimental data indicate that multi-frequency UMBIR reconstruction yields much higher reconstruction quality than either single frequency UMBIR or SAFT.

47 OTHER INSTRUMENTATION↗

Investigation of the relationship between classical and nonclassical ultrasound nonlinearity parameters and microstructural mechanisms in metals

This research studies two nonlinear ultrasound techniques: second harmonic generation and nonlinear resonant ultrasound spectroscopy, and the relationship to microstructural mechanisms in metals. The results show that there is a large change in both the classical, β, and nonclassical, α, ultrasound nonlinearity parameters in response to three specific microstructural mechanisms: precipitate growth in and along the grain boundaries, dislocations, and precipitate pinned dislocations. For example, both β and α increase with the growth of the precipitate radii (precipitate-pinned-dislocations). Additionally, both β and α increase when there is a growth of precipitates in and along the grain boundaries. As expected, β and α decrease when there is a removal of dislocations in the material. The relationship between β and α, and the microstructural mechanisms studied provide a quantitative understanding of the relationship between measured nonlinearity parameters and microstructural changes in metals, helping to demonstrate the possibility of using these two independent, but complementary, nonlinear ultrasound procedures to monitor microstructural damage.

Levy, Katherine Marie Scott↗