Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ultrasonic wave testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Monitoring of mechanical changes in a pipe assembly with complex geometry using multi-mode acoustic signals

Guided wave ultrasonic testing has been widely used for nondestructive and long-range evaluation of diverse mechanical structures, such as pipes and plates. In general, a large number of guided wave modes exist even in the simplest geometries, and they exhibit highly dispersive characteristics. Thus, sophisticated excitation methods and elaborate modal analyses need to be implemented to excite, acquire, and process well-defined pure modes as part of such a measurement method. If the interrogated structure has complex geometry, for example, with cross-sectional variations or multiple joints, the utilization of pure modes becomes significantly more difficult. To overcome this difficulty, this paper proposes the use of multi-mode, multi-frequency guided waves for long-range inspection of structures with arbitrarily complex geometries. Furthermore, using broadband chirp signals and multi-mode time–frequency analysis in a prototypical complex pipe assembly that includes multiple pipe diameters, elbows, and flange connections, we experimentally show sensitive detection of mechanical changes (both material addition and loss). In addition, we demonstrate that the complexity of the structure can be modeled in the digital domain with sufficient detail to allow accurate numerical simulation of the acoustic response using this method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermal modulation of nonlinear ultrasonic waves for nondestructive evaluation of elastic materials

Temperature variation is often considered an undesirable factor in ultrasonic testing, as wave velocity is highly sensitive to thermal fluctuations. However, completely eliminating the temperature effect is difficult, particularly in tests requiring precise velocity measurements. Recently, a method called Thermal Modulation of Nonlinear Ultrasonics (TMNL) has been developed. Instead of eliminating the thermal effect, the TMNL method leverages the temperature variation as a driving force to stimulate the nonlinear response of the medium and modulate the ultrasonic waves propagating in it. These modulated waves can then be used to evaluate the nonlinear behaviours of the test medium. This paper presents a focused review of the TMNL technique, including its theoretical foundations, particularly the conceptual challenges in integrating thermal effects into classical acoustoelastic theory, and recent applications in non-destructive evaluation (NDE). Three case studies are presented to demonstrate TMNL’s application in detecting microcracking in concrete, assessing ageing in polymer materials, and enabling temperature compensation in acoustoelastic tests. In conclusion, the review also summarises related studies, including photothermal crack modulation, and discusses current limitations and future directions of TMNL in elastic media.

NDE↗

Development of Methods for In-line Monitoring of Yield Stress During the Transfer of Radioactive Waste - 20435

Radioactive waste slurries at the Savannah River Site (SRS) and Hanford often behave as non-Newtonian fluids with a yield stress. The yield stress increases the size of equipment needed to transport or mix these slurries and can increase the risk of process upsets. This property is often measured by collection of samples and transportation to a laboratory, which can increase the risk of personnel exposure and even change the rheology. In addition, slurry rheology has been observed to change with time. Real-time in-line monitoring (RTIM) of rheological properties of slurries can have substantial benefits to critical processes which are currently in operation or will be part of future plans in Department of Energy (DOE) complex processes. The need for an appropriate RTIM technology that can potentially minimize or eliminate numerous sampling operations was recently identified. This research at Florida International University focuses on addressing the need for a reliable RTIM technology at US Department of Energy sites. The objective of this work is to investigate and develop appropriate and reliable technologies that can perform accurate and easy measurements of yield stress with minimal changes to the flow conditions at US Department of Energy sites. Use of ultrasound in longitudinal and shear modes was considered as a method for monitoring of yield stress variations with no disturbance to the flow. Measurement of shear wave velocity (in shear mode) and monitoring of sound velocity variations with start of flow from rest (longitudinal mode) are the underlying principles. Measurement of pressure loss and liquid rise (due to static differential pressure) during flow of slurries were two other methods that were considered and investigated. In addition, analysis of stability depth of a penetrometer in slurry medium (penetrometer method) revealed a potential suitability. This paper presents efforts associated with investigation of different methods mentioned earlier for kaolin-water mixtures at different concentrations. Theoretical analysis showed that all methods under investigation were capable of monitoring yield stress in a desirable range of 0 to 70 pascal. A bench scale test setup was constructed for investigation of pressure loss and liquid rise methods. Simulants at different concentrations were created for initial testing campaigns. For ultrasonic testing, effects of yield stress on sound propagation speed in longitudinal and shear modes were investigated for simulants placed inside PVC pipes. Parameters such as simulant concentration and pipe diameter were varied to find optimal values. It was found that spacing (or medium thickness) of 1/8 inch or less was necessary to observe echoes with sufficient strength. In addition, a significant effect of yield stress on sound propagation velocity was observed. For the liquid rise method, kaolin-water simulant at 1.17 specific gravity was pumped through a 1/4 inch pipe and liquid height was measured in a vertical riser branching off a three-way connection. Static gauge pressure was varied within [0.3 to 1.1] psi range by increase of pumping pressure and flow. Results showed consistent yield stress data within 10% deviation from values reported by a rheometer. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Exploiting Acoustic Anisotropy to Detect Recrystallization in a Ni Single Crystal Using Ultrasonic Nondestructive Inspection

Ultrasonic inspection was used to detect regions of recrystallization (RX) within a single crystal of Ni. RX can produce polycrystalline regions within single-crystal (SX) materials. Because RX regions act as initiator sites for failure by fatigue-crack growth in otherwise SX Ni-based superalloys, RX is an issue of direct concern for the service life of high-performance turbine blades. Detection and discrimination of RX regions in single-crystal materials are significant challenges for current nondestructive inspection technologies. The present study leverages the elastic anisotropy of single crystals, which produces acoustic anisotropy, to ultrasonically detect and characterize RX regions produced within single-crystal specimens. Single crystals of pure Ni were processed to create controlled regions of RX. These specimens were ultrasonically examined in an immersion tank using a high-resolution, polyvinylidene fluoride transducer to detect acoustic impedance changes across the boundaries between different crystals (i.e., grains) within the RX region. Data from time-of-flight and absolute peak amplitude measurements were used to create acoustic images that were compared against electron microscope images of the RX regions. The ultrasonic inspection technique described here successfully detected not only the locations of RX regions, but also the approximate sizes and shapes of the RX regions.

36 MATERIALS SCIENCE↗

JGR_Data_Reflection_Project

This research data is based upon the work supported by the U.S. Department of Energy, Office of Basic Energy Sciences, under Award Number DE‐SC0019117. Additional support provided by Colorado School of Mines is highly appreciated.

58 GEOSCIENCES↗

Double-Shell Tank Primary Bottom Inspection Development - 19067

Double-Shell Tank (DST) integrity at Hanford is maintained with a variety of activities such as ultrasonic and visual inspections, chemistry controls, corrosion monitoring and structural analyses methods [1]. A pressing need for the Double-Shell Tank Integrity Program is the ability to inspect the bottom of the tanks. Though the DSTs' annulus spaces (the space between the internal and external tank walls) have been inspected visually since 1992 and with Ultrasonic Testing (UT) since 1996, WRPS has been unable to conduct inspections of the tank bottoms due to limitations of available technology, omitting about 40 percent of the tank surface below the maximum fill level from routine inspection. Visual inspections of the tank annulus have been conducted up to five times in some DSTs and the annulus space for all of the DSTs has been inspected twice with UT. The annulus region includes the walls of the primary tank and secondary liner along with accessible portions of the secondary liner bottom. Due to the lack of under-tank inspection technology, degradation of the primary tank bottom in Tank AY-102 was undetected until the tank leaked into its annulus space, confirmed in 2012 [2]. Since that time, WRPS has been working with the nondestructive examination community and the Pacific Northwest National Laboratory to evaluate potential technologies to conduct these challenging remote inspections. Recent work has included the development, testing, and deployment of several remote visual inspection technologies to observe the condition of the primary tank bottom of the DSTs by leveraging air distribution slots in the refractory pad on which it rests. Robotic solutions to conduct this inspection were developed with a detailed understanding of the physical configuration and operational logistics. Understanding and subsequent communication of these details to vendors within the robotics and nondestructive examination community was a critical component to the successful production of these new tools. In total, two remote visual inspection tools were produced by two vendors. The first tool was designed to leverage existing ultrasonic testing magnetic wall crawler technology in use within the double-shell tank annuli at Hanford. This resulted in a cost savings, immediate familiarization with the equipment, and a more streamlined shop to field experience. The second tool was developed from the ground up, and represents a more tailored and purpose-built solution to the problem. While costlier and more complex, it is also more versatile and capable of future growth or adaptation. Initial design of both tools began in early FY17 with fabrication and testing completed in early FY18. The tools were designed to be deployed alongside existing inspection operations and expand coverage. Development of visual inspection tools to evaluate the primary tank bottom region of the double-shell tanks was planned as the first stage of inspection. Continued development of volumetric sensors and incorporation of these inspection tools into Hanford's ongoing Double-Shell Tank Integrity Program are the next steps, continuously seeking to expand understanding of asset integrity and remaining useful life. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Double-Shell Tank Primary Bottom Visual Inspection Results - 20025

A pressing need for the Double-Shell Tank Integrity Program at Hanford is of the ability to inspect the bottom of the tanks. Though the DSTs' annulus spaces (the space between the internal and external tank walls) have been inspected visually since 1992 and with Ultrasonic Testing (UT) since 1996, inspections of the tank bottoms have been able to be conducted due to limitations of available technology, omitting about 40 percent of the tank surface below the maximum fill level from routine inspection. Visual inspections of the tank annulus have been conducted up to five times in some DSTs and portions of the annulus space for all of the DSTs has been inspected twice with UT. This region includes the walls of the primary tank and secondary liner along with accessible portions of the secondary liner bottom. Due to this lack of technology, the degradation of the primary tank bottom in Tank AY-102 was undetected until the tank leaked into its annulus space, confirmed in 2012. Since that time, WRPS has been working with the nondestructive examination community and the Pacific Northwest National Laboratory, to evaluate potential technologies to conduct these challenging remote inspections. Recent work has included the development, testing, and deployment of several remote visual inspection technologies to observe the condition of the primary tank bottom of the DSTs by leveraging air distribution slots in the refractory pad on which it rests. Robotic solutions to conduct this inspection were developed with a detailed understanding of the physical configuration and operational logistics. Understanding and subsequent communication of these details to vendors within the robotics and nondestructive examination community was a critical component to the successful production of these new tools. Throughout the FY16-FY18 years, vendors from nondestructive examination community were solicited for ideas to meet the tank bottom inspection challenge. Two tank bottom visual inspection solutions were then pursued to meet that challenge. Both tools were successfully deployed at Tank AP-107, and provided valuable visuals, never before obtained from the under tank environment of a double-shell tank. While there are minor opportunities for improvement identified with each system, general outcomes were overwhelmingly positive. Both systems were successfully able to navigate the refractory air slot pattern from the outer edge to the tank center and record video footage. The micro-crawler provided high quality and very stable footage through the air slot pattern, but took longer to deploy into the slots and traverse through them than the alternative system. The push-pull tethered camera was able to navigate all seven of its target air slots in a matter of a few hours, which included deployment, movement between slot entrances, and complete removal of the system from the annulus environment. Through these air slots, new information was gained about the tank bottom and refractory pad condition of tank AP-107, AP-106, AP-108, and AN-102. While some debris was noted in the air slots, including sand, chipped refractory, and construction materials, the refractory was found to be structurally stable and adequately supporting the primary tank bottom through the full diameter of the tank. Primary tank bottom steel exterior was found to be in good condition, free of ongoing or aggressive corrosion conditions. Looking toward the future, robotic access to and visual inspection of refractory air slots and the primary tank bottom steel has now proven viable. Incorporating periodic air slot inspections as a regular practice within the Double-Shell Tank Integrity Program is the next step, allowing trending of any changes in condition. As ultrasonic testing infrastructure was leveraged to complete the initial system deployments described in this report, it makes sense to adopt that same strategy for ongoing periodic examinations and deploy these primary tank bottom inspection tools alongside ultrasonic testing operations. Development of visual inspection tools to evaluate the primary tank bottom region of the double-shell tanks was planned as the first stage of inspection. Continued development of volumetric sensors and incorporation of these inspection tools into Hanford's ongoing Double-Shell Tank Integrity Program are the next steps, seeking to continuously expand understanding of asset integrity and remaining useful life. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Novel Foaming Solutions for High Level Waste (HLW) Processing - 20195

Foaming occurs during treatment of high level waste (HLW) at Savannah River Site's Defense Waste Processing Facility (DWPF) in the Chemical Process Cell (CPC) due to high gas generation from process steam and chemical offgas products [1]. The presence of amphiphilic particles in the waste slurry stabilizes the foam [2], [3]. Efficient processing of HLW requires foam control, as foam-overs lead to lower productivity and potential radioactive contamination of condensate streams. DWPF currently employs Siovation Antifoam 747, a surfactant produced by Momentive Performance Materials, as an antifoaming agent during waste treatment. Despite its ability to control foam generation, processing issues have arisen from its use [4]. During DWPF chemical processing, a chemical antifoam agent must be effective at temperatures up to 103 deg. C between pH 3-13. Antifoam 747 is effective at pH 7 but degrades as pH deviates [5]. Antifoam 747 is 90% by weight Momentive{sup TM} L77 and 10% by weight Momentive{sup TM} Y-17580. These ingredients are trisiloxane products, which are especially vulnerable to attack in acidic and caustic environments. Since Antifoam 747 readily degrades, periodic addition is required. Several processing concerns related to Antifoam 747 have affected DWPF operation. Its overuse warranted concern of potential flammable melter offgas under upset conditions due to the generation of carbon dioxide and hydrogen. As a result, a Potential Inadequacy in the Safety Analysis (PISA) was declared [6]. Antifoam contribution has been included in the melter offgas flammability strategy and the quantity of antifoam is monitored to ensure limits are not exceeded. Testing at Savannah River National Laboratory (SRNL) determined that propanal, tri-methylsilanol, and hexamethyldisiloxane are generated as Antifoam 747 degrades, leading to a second PISA [7]. The formation of these byproducts poses additional flammability risks. Furthermore, the methyl and ethyl groups of these compounds may be responsible for the formation of the methyl and ethyl mercury discovered in DWPF [8], [9]. The formation of organomercury has specifically been called out by DOE as a need for increased research. The effectiveness of non-chemical methods for foam control and the efficiency of alternative antifoam agents were evaluated as part of an effort to improve HLW treatment operations at DWPF and to reduce, or eliminate, the flammability hazards associated with Antifoam 747 currently in use. Foaming of high-level waste (HLW) slurries is an issue at the Defense Waste Processing Facility (DWPF) Chemical Process Cell (CPC) which is currently mitigated with a chemical antifoam agent. The effectiveness of non-chemical methods for foam control and the efficiency of alternative antifoams were examined to improve HLW treatment at DWPF and to eliminate the flammability hazards associated with Siovation Antifoam 747 currently in use. Non-chemical foam control methods were deemed unviable for chemical processing at DWPF, as the spray/mist technique requires too much water and space limitations make installation and implementation of headspace agitators unfeasible. The use of ultrasonic energy thickened and further stabilized the foam. Two suitable alternative defoaming agents, Momentive{sup TM} Y- 17112 and Evonik Surfynol{sup R} MD-20, were identified. Both defoamers control foam over a pH range of 4- 13 at boiling, with no flammable degradation products, and only minimal quantities (100-200 mg/kg) are required under glycolic acid conditions. In order to validate the effectiveness of these defoaming agents, SRNL recommends irradiation testing and laboratory scale SRAT/SME experiments with actual radioactive waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

History of Ultrasonic Inspection of High-Level Waste Tanks at SRS - 20220

The Liquid Waste Disposition Projects (LWDP) Structural Authority and Inspection Engineering Support Group has teamed with the Materials Science and Technology Non-destructive Evaluation Group of Savannah River National Laboratory (SRNL) to implement a comprehensive In-Service Inspection (ISI) program for the High-Level Waste (HLW) tanks in the sites tank farms. The purpose of this program is to demonstrate the structural and leak integrity of the tanks to maintain the function of waste containment throughout the desired service life. Four types of waste tanks were constructed at Savannah River Site (SRS) from 1951 thru 1981 to store radioactive nuclear waste from the separations process. The Type I, II and III are carbon steel cylindrical tanks with varying degrees of access to the side walls and very limited access to the tank bottom. The tanks contain 750,000 to 1.3 million gallons of waste and are buried or backfilled with soil. The tanks are 75'-85' in diameter and 24'-33' from tank bottom to the tank roof. Inspection of the HLW tanks is made difficult by radiation, contamination, and small access openings. Through the years these challenges have been overcome by progressive improvements to programs and equipment resulting in the sophisticated wall crawler Ultrasonic Testing (UT) technology of today. A formal inspection program was developed and put in service in 1972. UT thickness measurements were first made in 1967 and 1969 of selected waste tanks using an analog-type instrument to measure the thickness of the carbon steel walls. Routine inspections for thinning were performed from 1972-1985 and then discontinued because no thinning had been observed and this technique could not detect pitting or cracking. UT inspections resumed in 1994 using a sophisticated robotic wall crawler with UT technology capable of detecting thinning, cracking and pitting. The current program focuses on the newer Type III tanks that are used primarily for storage. The program was upgraded in 2003 to include selected regions of the tank wall, secondary wall and annulus floor on a 7 to 10-year frequency. The facility is currently in its third cycle of tank inspections. Thus far, there have been no reportable indications of service induced degradation. This result provides assurance that the chemistry control program has been effective at mitigating corrosion and that the tanks remain structurally sound even after more than 40 years of service. This paper will present the UT technology first used at SRS and the evolution to the current systems and their capabilities. Additionally, plans for equipment upgrades that will improve the extent of inspection will be discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a Testbed for Pipeline Flushing - 20425

Pipelines which carry high-level waste within the DOE complex should be properly flushed in the cases where stationary or moving beds of solid sediment occur, or lines are prone to hydrogen gas buildup. Present guidelines establish a minimum for the amount of water (flush volume) and flush velocity values used for post-transfer flushing operations to achieve satisfactory cleaning of pipelines. However, further studies are needed to find optimal operating velocity modes/values in order to minimizing the flush volume and consequent downstream waste. These efforts are significantly helpful to DOE waste remediation sites by preserving tank storage, preventing additional waste processing, and minimizing dilution and changes in waste chemistry. An experimental test loop was recently developed for study of non-Newtonian slurry flushing at the Florida International University (FIU). This loop was designed to create sediment beds of various materials and bed heights and investigate parameters that effect the efficiency of flushing operations. The objective is to find flush velocity values/modes which lead to satisfactory cleaning of transport lines with a minimum amount of water usage. A 165 ft experimental test loop made of 3-inch carbon steel pipes was constructed and used in initial testing campaigns. This pipe loop was equipped with real-time monitoring instruments to record variation of pressure, density, mass flow rate, and temperature during testing. Post-flush in-situ no-flow evaluations were performed using ultrasonic, endoscopy, and visual inspection. Additional post-flush evaluations were conducted using filtration and density monitoring of residuals within a designated circulations loop. These provisions enable comparison of pipeline cleanness before the start and after termination of flushing operations for efficiency evaluation. This paper presents efforts associated with flushing of kaolin-water mixtures at different concentrations and with various flush volume and flush velocity values/modes. In initial testing, efforts focused on creating repeatable sediment beds inside the pipeline in both fully-flooded (no pre-flush drainage) and gravity-drained (pre-flush drained) systems. Bed characterization (i.e., measurement of sediment height and solids concentration) was conducted to ensure about consistency of initial conditions between tests. Preliminary results for flushing study of 10% vol. kaolin-water mixtures starting from a fully-flooded initial condition showed that flushing with 1-line volume (65 gallons) could remove up to 72 percent of solids from the pipeline. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determination of acoustic nonlinearity parameters using thermal modulation of ultrasonic waves

This study presents a test method and its theoretical framework to determine the acoustic nonlinearity parameters (α, β, δ) of material using thermal modulation of ultrasonic waves. Temperature change-induced thermal strain excites the nonlinear response of the material and modulates the ultrasonic wave propagating in it. Experimental results showed a strong correlation between the relative wave velocity change and the temperature change. With a quadratic polynomial model, the acoustic nonlinearity parameters were obtained from the polynomial coefficients by curve fitting the experimental data. Their effects on thermal-induced velocity change were discussed. The parameters α, β, and δ govern the hysteretic gap, average slope, and curvature of the correlation curve, respectively. The proposed theory was validated on aluminum, steel, intact and damaged concrete samples. The obtained nonlinear parameters show reasonable agreement with values reported in the literature. Compared to other nonlinear acoustic methods using vibration or acoustic excitation, the thermal modulation method generates more uniform, slow changing, and larger strain field in the test sample. Employing the thermal effect as the driving force for nonlinearity instead of an undesired influencing factor, this method can measure the absolute values of α, β, and δ with good accuracy using a simple ultrasonic test setup.

Physics↗

Narrow band photoacoustic lamb wave generation for nondestructive testing using candle soot nanoparticle patches

The generation of ultrasonic surface waves with a photoacoustic-laser-source has become useful for the noncontact nondestructive testing and evaluation (NDT&E) of materials and structures. In this work, a hybrid ultrasound based NDT&E method is proposed based on the photoacoustic-laser-source as a noncontact Lamb wave generator by incorporating a line-arrayed patterned candle soot nanoparticle-polydimethylsiloxane (CSNPs-PDMS) patch as the signal amplifier and with a narrow bandwidth. The CSNP-PDMS composite has been investigated as the functional patch for its laser energy absorption efficiency, fast thermal diffusion, and large thermoelastic expansion capabilities. The signal amplitude (in mW) from the CSNP-PDMS patch exhibits 2.3 times higher amplitude than the no patch condition and a narrower bandwidth than other conditions. Furthermore, improvement in the sensitivity is also achieved through the selection of the aluminum nitride sensing system. The overall combination of the Lamb wave generation and receiver-sensing system in this study is found to be very promising for a broad range of noncontact NDT&E applications.

Acoustic transducers↗

Development of NDE/NDT Tools for High-Volume & High-Speed Inspection of CFRP Structures in Automotive Manufacturing

Main advantages of the air-coupled ultrasound testing (ACUT) and electromagnetic testing (EMT) techniques for NDE of CFRP composites were non-contact sensing, scalability for high-speed inspection, cost-effectiveness, and non-hazardous operation. Despite these advantages, no systems that would satisfy the project requirements were commercially available. Hence, one of the major efforts of the Michigan State University (MSU) team at the initial stage of the project was to close this technological gap by developing, optimizing, and validating array sensors that would provide sufficient sensitivity, spatial coverage, and resolution for robust defect detection. Optimization of the ACUT and EMT sensor designs was performed using experimentally validated finite element models. Initial experiments using array probes were conducted on relatively flat CFRP samples. In parallel, the MSU team designed and assembled a portable platform with two robotic arms. The robots were equipped with newly designed sensors that enabled high-speed NDE of curved CFRP parts. Presently, the developed robotic platform can be used as a demo/template NDE system, which is easily adaptable to manufacturing environments and in-line NDE. The ACUT NDE system developed by the MSU team used a high-power 4-channel pulser receiver for parallel data acquisition. The array probes were designed by stacking commercially available ACUT transducers, which operated in the frequency range between 100 kHz and 500 kHz. MSU optimized the excitation procedure and developed wave focusing cones so as to reduce the crosstalk between the transducers and to provide higher pulse repletion frequency (PRF). The through-transmission (TT) and single-side access (SSA) inspection modes were successfully implemented. In the TT-ACUT, structural defects in CFRP were detected by passing ultrasonic waves through the test part. Hence, the ACUT transmitters and receivers needed to be placed on the opposite sides of the test part. In the SSA-ACUT, guided waves (GW) were excited in the test part using the transmitters and were sensed by the receivers from the same side. Multi-channel TT-ACUT and SSA-ACUT provided high-speed NDE, and were successfully validated on CFRP test samples with interlaminar delaminations and other embedded defects The EM techniques developed by the MSU team included: 1) eddy current testing (ECT), 2) capacitive imaging (CI) and hybrid dual-mode imaging. In ECT, structural damage was detected in CFRP using coils sensor arrays. In ECT, the excitation magnetic field is generated by passing an alternating current through a coil, which is placed above the test sample. The excitation field penetrates the conductive sample and induces the eddy currents in its transect. In turn, the eddy currents generate the reaction field, which affects the total field sensed by a coil. Hence, the presence of structural flaws will alter the eddy current flow and the picked-up signal. ECT is mostly sensitive to local changes of the electric conductivity of the test sample, and CFRPs are mostly conductive in the direction of carbon fibers. Hence, ECT was well suited for the detection of fiber damage/fiber irregularities. The MSU team developed printed circuit boards (PCB) with coil sensor arrays optimized for NDE of CFRP. Unlike most commercial probes designed for ECT of metallic structures, the MSU array probes were designed for operation in [1-10] MHz frequency range, which was optimal for low-conductive CFRP. Multiple sensing topologies (coil groups excitation/sensing arrangements) were implemented and successfully validated. Capacitive Imaging (CI) technique developed by MSU was complementary to ECT. In contrast to ECT, which was sensitive to local changes of the electrical conductivity, the CI was sensitive to local changes of the dielectric constant. Therefore, CI could provide information about matrix damage/matrix irregularities in CFRP. The MSU CI sensor arrays were made of multiple circular or rectangular open-plate capacitors printed on PCB. Sensors of this type are not commercially available. In addition to ECT and CI, the MSU team developed a hybrid (dual-mode) inductive/capacitive measurement technique that synergistically combined the benefits of inductive and capacitive sensing for rapid NDE of fiber reinforced polymer (FRP) composite structures. Fiber damage and fiber irregularities in FRPs were detected by configuring hybrid sensors as coil sensors. Similarly, matrix damage, matrix irregularities and interlaminar delaminations were detected by configuring hybrid sensors as capacitive sensors. ECT and CI were performed sequentially by means of electronic switching. Hence, eliminating the need for mounting two separate sensor arrays on the probe. Portable robotic platform was developed by MSU for multi-technique high-speed NDE of CFRP test parts. The platform had two 6-axis robots, which enabled inspection of curved parts in approximately a 6×6×6 ft 3 active scan area. On the software side, the MSU team integrated scripts for NDE hardware control with scripts for robot motion control. MSU also implemented automated path planning for the robots, reconstruction of part’s surfaces via stereovision, 3D rendering of inspection data, and image processing algorithms for enhanced defect detection. Automotive composite parts manufactured by Plasan Composites from Phase I were used to validate the ACUT and EMT techniques on representative testbeds. Among those parts were three X-braces for a Dodge Viper, one composite calibration plaque with known defects at known locations, and four other test sections, including sections from a front splitter, a corner section from a composite hood, and a high-pressure RTM panel made using non crimp fabric. Other test samples included CFRP and GFRP calibration plates with fiber/matrix defects fabricated at MSU/CVRC.

36 MATERIALS SCIENCE↗

The estimation of Poisson’s ratio by time-averaging and Cornu’s method for isotropic beams

Prior research suggests that direct static (e.g., uniaxial testing) and dynamic (e.g., ultrasonic wave propagation analysis) measurements differ in the estimation of Poisson’s ratio because anisotropies and heterogeneities in the sample material affect the two types of tests differently. Even assuming isotropic and homogeneous material properties, prior research further suggests that discrepancies between static/dynamic test results will exist because the error of the diagnostic techniques for the measurand are inherently different. Finally, thermodynamic effects are not present in static tests but can significantly affect dynamic test results. Given the potential for all these variables to produce discrepancies, it would be helpful to have the measurement of Poisson’s ratio obtainable from the same theory and experimental measurements by either static or dynamic testing methods. Our finite element calculations show that by combining time-averaged scanning digital holography with Cornu’s method, it is theoretically possible to estimate the effective Poisson’s ratio from the anticlastic contours at the antinode of the first out-of-plane bending mode shape. This is true regardless of frequency and therefore applicable for both static and dynamic measurements. Our results show that the estimate of Poisson’s ratio by Cornu’s method using data from simulations of mode shapes approaches the true value of Poisson’s ratio. Additionally, our research suggests that beam geometry and boundary conditions are fundamental factors limiting the convergence of the estimate of Poisson’s ratio to the true value of Poisson’s ratio regardless of performing a static or dynamic test.

42 ENGINEERING↗

Erosion-Corrosion Detection in Carbon Steel Pipe Loops using SRNLs Thickness and Mass Loss Measurement Coupons - 20464

Structural health of waste transfer infrastructure is of utmost importance to DOE and communities surrounding their active sites. A Fitness-for-Service (FFS) program for the Waste Transfer System has been implemented by the US Department of Energy (DOE) for the purposes of evaluating and quantifying the degradation of critical components. Currently, the method of approach is to section and evaluate pipelines that have been removed at end service. In order to augment data collection methods applied to making lifespan estimates of waste transfer system components, Florida International University (FIU) has been investigating new-technology based strategies for quantifying the rate of degradation. Present research considers the option of a coupon system installed on a section of pipe at points of interest that will provide easy access to high resolution measurements of erosion/corrosion rates during operation. Researchers at Savannah River National Laboratory (SRNL) have developed this novel solution for in situ erosion and corrosion measurements in many applicable locations such as tanks, pipes, ducts, and injection points. The coupons are approximately 12.7 mm (1/2 inch) in diameter and 25.4 mm (1 inch) in length and can be placed in the pipe sections using Swagelok compression fittings. The coupon design allows for monitoring of the total degradation resulting from corrosion and erosion. High-resolution Ultrasonic Thickness (UT) testing allows in-situ monitoring of both degradation mechanisms. When removed from the system mass loss resulting from corrosion and erosion may also be evaluated. Experimental testing at FIU implemented the SRNL coupon system in a 6.10 meter (20 foot) pipe loop system comprised of 50.8 mm (2 inch) and 76.2 mm (3 inch) pipe sections in order to replicate expected use cases at the sites. Operational conditions were emulated by pumping abrasive materials through the pipeline at full capacity and collecting measurements from the SRNL coupons. Initial testing was conducted by circulating water followed by a mixture of sand and water for uniform wear rates. Thickness changes and mass loss were measured, and the surface exposed to the process fluid was observed for visual evidence of characteristic wear patterns resulting from an erosive environment. The test matrix consisted of several hours of operation and using fine, medium and coarse grain sands. Test results were analyzed to check for all three parameters (mass loss/gain, thickness change and surface patters) which could provide estimates of the remaining useful life of the pipe sections. Thus, the research presents the findings of this evaluation of the SRNL coupons as a means for conducting high accuracy, cost effective in-situ analysis of pipeline and waste transfer systems for erosion and corrosion susceptibility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Acoustic Channel Capacity for Complex Piping Topology

Transmission of information using elastic waves on existing metallic pipes provides an alternative communication option for a nuclear facility. The advantages of this approach consist of transmitting information through physical barriers, such as the containment building wall. In addition, this approach provides physical cybersecurity since the pipe becomes an analog communication channel which is difficult to eavesdrop on and difficult to sever. In prior work, a laboratory bench-scale system consisting of a six foot-long straight section of nuclear grade stainless steel pipe and high-temperature ultrasonic LiNbO 3 transducers was assembled. The lab systems was used for communication protocol development and preliminary data transmission demonstration. Next phase of project development involves deployment of the ultrasonic communication system in a representative environment. Mechanisms Engineering Test Loop (METL) facility at ANL was chosen as a viable candidate for communication system demonstration. Analysis of piping manifolds at METL has shown that in a typical scenario, ultrasonic signals have to be transmitted over straight and bent piping sections. This report describes preliminary studies on transmission of information with ultrasonic shear waves across bent piping sections. A test article consisting of a stainless steel pipe bent at 90° was developed for laboratory analysis of ultrasonic signal transmission. The bent piping test article developed by welding two straight pipes to an elbow. For consistency, the diameter and wall thickness of the bent pipe is the same as that of the straight pipe utilized in prior studies. COMSOL computer simulations were performed to study ultrasonic refracted shear wave coupling and transmission across bent piping. Preliminary evaluations of ultrasonic shear wave transmission were conducted with piezoelectric (PZT) and LiNbO 3 transducers, with the signals recorded with previously developed LabView interface. Preliminary results have shown significant dispersion of transmitted signals, most likely due to reflections and scattering by piping welds. Signal distortion compensation algorithm based on time reversal modulation (TRM) was initially investigated for transmission through solids, and demonstrated for signals transmitted over the bent pipe. Using TRM, it was shown that communication bitrates of 100Kbps were achievable, in principle.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Final Report for Transmission of Information by Acoustic Communication along Metal Pathways in Nuclear Facilities

Transmission of information using elastic waves on existing metallic pipes provides an alternative communication option for a nuclear facility. The advantages of this approach consist of transmitting information through barriers, such as the containment building wall. A viable candidate for acoustic communication channel is a chemical volume control system (CVCS) stainless steel pipe, which penetrates through the containment building wall. A laboratory bench-scale system consisting of a nuclear grade CVCS-like pipe and ultrasonic transducers was assembled for a preliminary communication system analysis. Because of low bandwidth and spectral dispersion of ultrasonic transducers, on off keying (OOK) protocol was chosen for data communication. Operation of the acoustic communication during normal and post-accident conditions involves data transmission on the CVCS pipe, which according to literature guidelines, will be at 50°C and 150°C, respectively. Preliminary communication system development was performed using paintbrush PZT transducers capable of continuous operation at temperatures up to 80°C. Next, high-temperature LiNbO 3 acoustic transducers, originally developed for flow metering applications of EBRII reactor at Argonne, were utilized to develop a high-temperature acoustic communication system. A Gaussian pulse shape filter was introduced to suppress ringing and thus reduce inter-symbol interference. This resulted in enhancement of data transmission bitrate. Heating tapes, temperature controllers, and thermal insulation were installed on the laboratory pipe to study acoustic communication at elevated temperature. This included development of custom insertion heating elements for controlling temperature at pipe ends. Demonstrations of communication at high temperature included transmission of images and text files. Main achievements thus far include demonstration of transmission of 90KB image at the bitrate of 10Kbps with bit error rate smaller than 10 -3 across the pipe heated to 50°C and 150°C. Final phase of project development involved investigating strategies for deployment of the ultrasonic communication system in a representative environment. Mechanisms Engineering Test Loop (METL) facility at ANL was chosen as a viable candidate for communication system demonstration. Analysis of piping manifolds at METL has shown that in a typical scenario, ultrasonic signals have to be transmitted over straight and bent piping sections. This report describes preliminary studies on transmission of information with ultrasonic shear waves across bent piping sections. A test article consisting of a stainless steel pipe bent at 90° was developed for laboratory analysis of ultrasonic signal transmission. The bent piping test article developed by welding two straight pipes to an elbow. For consistency, the diameter and wall thickness of the bent pipe is the same as that of the straight pipe utilized in prior studies. COMSOL computer simulations were performed to study ultrasonic refracted shear wave coupling and transmission across bent piping. Preliminary evaluations of ultrasonic shear wave transmission were conducted with piezoelectric (PZT) and LiNbO 3 transducers, with the signals recorded with previously developed LabView interface. Preliminary results have shown significant dispersion of transmitted signals, most likely due to reflections and scattering by piping welds. Signal distortion compensation algorithm based on time reversal modulation (TRM) was initially investigated for transmission through solids, and demonstrated for signals transmitted over the bent pipe. Using TRM, it was shown that communication bitrates of 100Kbps were achievable, in principle.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ultrasonic nondestructive diagnosis of lithium-ion batteries with multiple frequencies

Accurately estimating the state of charge (SoC) in battery management systems (BMSs) requires the measurement of numerous parameters and advanced algorithms. This work studies multifrequency ultrasonic waves to estimate the SoC of Li-ion batteries by sensing the material changes during charge/discharge. A pouch-type LiNi 0.6 Mn 0.2 Co 0.2 O 2 (NMC622) graphite battery cell is designed and fabricated with a capacity of 2.4 Ah. Different ultrasonic testing setups are explored to determine the optimal testing parameters for the battery. An ultrasonic monitoring system is developed to monitor the battery during charge/discharge at 750 kHz, 1 MHz, and 1.5 MHz. Signal processing algorithms are proposed for extracting three ultrasonic features—amplitude, wave velocity, and attenuation. In a three-cycle test, the amplitude histories do not show clear correlations with the SoC. The wave velocities of all three frequencies have an approximately linear relationship with the SoC, which can be used for SoC estimation. Hysteresis behavior is observed for the wave velocity in terms of a larger slope in the discharge process and velocity drop after a close charge/discharge cycle. The wave attenuation is able to capture the material phase transitions during charge/discharge.

25 ENERGY STORAGE↗