Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “two step target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Immortalization of normal human mammary epithelial cells in two steps by direct targeting of senescence barriers does not require gross genomic alterations

Telomerase reactivation and immortalization are critical for human carcinoma progression. However, little is known about the mechanisms controlling this crucial step, due in part to the paucity of experimentally tractable model systems that can examine human epithelial cell immortalization as it might occur in vivo. We achieved efficient non-clonal immortalization of normal human mammary epithelial cells (HMEC) by directly targeting the 2 main senescence barriers encountered by cultured HMEC. The stress-associated stasis barrier was bypassed using shRNA to p16INK4; replicative senescence due to critically shortened telomeres was bypassed in post-stasis HMEC by c-MYC transduction. Thus, 2 pathologically relevant oncogenic agents are sufficient to immortally transform normal HMEC. The resultant non-clonal immortalized lines exhibited normal karyotypes. Most human carcinomas contain genomically unstable cells, with widespread instability first observed in vivo in pre-malignant stages; in vitro, instability is seen as finite cells with critically shortened telomeres approach replicative senescence. Our results support our hypotheses that: (1) telomere-dysfunction induced genomic instability in pre-malignant finite cells may generate the errors required for telomerase reactivation and immortalization, as well as many additional “passenger” errors carried forward into resulting carcinomas; (2) genomic instability during cancer progression is needed to generate errors that overcome tumor suppressive barriers, but not required per se; bypassing the senescence barriers by direct targeting eliminated a need for genomic errors to generate immortalization. Achieving efficient HMEC immortalization, in the absence of “passenger” genomic errors, should facilitate examination of telomerase regulation during human carcinoma progression, and exploration of agents that could prevent immortalization.

59 BASIC BIOLOGICAL SCIENCES↗

Optimization Studies for ISOL Type High-Powered Targets

The research studied one-step and two-step Isotope Separation on Line (ISOL) targets for future radioactive beam facilities with high driver-beam power through advanced computer simulations. As a target material uranium carbide in the form of foils was used because of increasing demand for actinide targets in rare-isotope beam facilities and because such material was under development in ISAC at TRIUMF when this project started. Simulations of effusion were performed for one-step and two step targets and the effects of target dimensions and foil matrix were studied. Diffusion simulations were limited by availability of diffusion parameters for UC x material at reduced density; however, the viability of the combined diffusion?effusion simulation methodology was demonstrated and could be used to extract physical parameters such as diffusion coefficients and effusion delay times from experimental isotope release curves. Dissipation of the heat from the isotope-producing targets is the limiting factor for high-power beam operation both for the direct and two-step targets. Detailed target models were used to simulate proton beam interactions with the targets to obtain the fission rates and power deposition distributions, which were then applied in the heat transfer calculations to study the performance of the targets. Results indicate that a direct target, with specification matching ISAC TRIUMF target, could operate in 500-MeV proton beam at beam powers up to ~40 kW, producing ~8 10 13 fission/s with maximum temperature in UCx below 2200 C. Targets with larger radius allow higher beam powers and fission rates. For the target radius in the range 9-mm to 30-mm the achievable fission rate increases almost linearly with target radius, however, the effusion delay time also increases linearly with target radius.

43 PARTICLE ACCELERATORS↗

DE-FG02-05ER64001 Overcoming the hurdles of multi-step targeting (MST) for effective radioimmunotherapy of solid tumors

The 4 specific aims of this project are: (1) Optimization of MST to increase tumor uptake; (2) Antigen heterogeneity; (3) Characterization and reduction of renal uptake; and (4) Validation in vivo of optimized MST targeted therapy. This proposal focussed upon optimizing multistep immune targeting strategies for the treatment of cancer. Two multi-step targeting constructs were explored during this funding period: (1) anti-Tag-72 and (2) anti-GD2.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Age and the means of bypassing stasis influence the intrinsic subtype of immortalized human mammary epithelial cells

Based on molecular features, breast cancers are grouped into intrinsic subtypes that have different prognoses and therapeutic response profiles. With increasing age, breast cancer incidence increases, with hormone receptor-positive and other luminal-like subtype tumors comprising a majority of cases. It is not known at what stage of tumor progression subtype specification occurs, nor how the process of aging affects the intrinsic subtype. We examined subtype markers in immortalized human mammary epithelial cell lines established following exposure of primary cultured cell strains to a two-step immortalization protocol that targets the two main barriers to immortality: stasis (stress-associated senescence) and replicative senescence. Cell lines derived from epithelial cells obtained from non-tumorous pre- and post-menopausal breast surgery tissues were compared. Additionally, comparisons were made between lines generated using two different genetic interventions to bypass stasis: transduction of either an shRNA that down-regulated p16INK4A, or overexpressed constitutive active cyclin D1/CDK2. In all cases, the replicative senescence barrier was bypassed by transduction of c-Myc. Cells from all resulting immortal lines exhibited normal karyotypes. Immunofluorescence, flow cytometry, and gene expression analyses of lineage-specific markers were used to categorize the intrinsic subtypes of the immortalized lines. Bypassing stasis with p16 shRNA in young strains generated cell lines that were invariably basal-like, but the lines examined from older strains exhibited some luminal features such as keratin 19 and estrogen receptor expression. Overexpression of cyclin D1/CDK2 resulted in keratin 19 positive, luminal-like cell lines from both young and old strains, and the lines examined from older strains exhibited estrogen receptor expression. Thus age and the method of bypassing stasis independently influence the subtype of immortalized human mammary epithelial cells.

59 BASIC BIOLOGICAL SCIENCES↗

Molecular mechanism of crystallization impacting calcium phosphate cements

In summary, SPM data has shown that (1) Mg inhibits growth on all steps but relatively high Mg/Ca ratios are needed. Extracting the mechanism of interaction requires more modeling of the kinetic data, but step morphology is consistent with incorporation. (2) Citrate has several effects depending on the citrate/Ca ratio. At the lowest concentrations, citrate increases the step free energy without altering the step kinetics; at higher concentrations, the polar step is slowed. (3) Oxalate also slows the polar step but additionally stabilizes a new facet, with a [100]{sub Cc} step. (4) Etidronate has the greatest kinetic impact of the molecules studied. At 7{micro}M concentrations, the polar step slows by 60% and a new polar step appears. However, at the same time the [10-1]{sub Cc} increases by 67%. It should be noted that all of these molecules complex calcium and can effect kinetics by altering the solution supersaturation or the Ca to HPO{sub 4}{sup 2-} ratio. For the SPM data shown, this effect was corrected for to distinguish the effect of the molecule at the crystal surface from the effect of the molecule on the solution speciation. The goal of this paper is to draw connections between fundamental studies of atomic step motion and potential strategies for materials processing. It is not our intent to promote the utility of SPM for investigating processes in cement dynamics. The conditions are spectacularly different in many ways. The data shown in this paper are fairly close to equilibrium (S=1.6) whereas the nucleation of cements is initiated at supersaturation ratios in the thousands to millions. Of course, after the initial nucleation phase, the growth will occur at more modest supersaturations and as the cement evolves towards equilibrium certainly some of the growth will occur in regimes such as shown here. In addition to the difference in supersaturation, cements tend to have lower additive to calcium ratios. As an example, the additive to Ca ratio is {approx}10{sup -3} to 10{sup -4} for a pyrophosphate based cement (Grover et al., 2006). Where the in situ SPM approach provides unique insights is in providing details of where and how molecules inhibit or accelerate kinetics. This has the potential to aid in designing molecules to target specific steps and to guide synergistic combinations of additives. For example, it is unlikely that bulk techniques could deduce the simultaneous acceleration and inhibition effects of etidronate; or that citrate reduced growth rate by altering step density rather than step speed. In addition, SPM data translates to tractable questions for modelers. The questions changes from 'How does etidronate inhibit brushite growth?' to 'Why does etidronate bind strongly to the [101]{sub Cc} step while it doesn't to the [10-1]{sub Cc} step?' This is still a challenging question but it is far better defined. Given that step chemistries are generally different, it seems reasonable to expect that the greatest inhibition will be achieved not with one, but with several synergistically chosen additives. For example, the most effective growth inhibitors for brushite would target the two fast steps, namely the non-polar, [10-1]{sub Cc} and the polar, [101]{sub Cc} steps. Several molecules have been shown to slow the polar step, with etidronate as the most dramatic example. By contrast, only Mg was observed to slow the [10-1]{sub Cc} step. Thus, a combination of high concentrations of Mg to target the [10-1]{sub Cc} step with low concentrations of etidronate to target the polar steps, should be a more effective combination than either alone. However Mg is not a particularly good inhibitor in the sense that high concentrations are needed, and it is not specific. More ideally, an inhibitor would be designed to interact specifically with the [10-1] step, which would allow the two steps to be independently modified. Again, this provides an opportunity for tighter coupling with theoretical modeling. The question changes from 'What types of molecules will inhibit brushite growth' to 'What type of molecule will interact with the [10-1]{sub Cc} step?' Similarly, to increase resorption rate, it would be most efficacious to target the slow moving [-100] step, perhaps by targeting the hydroxyl group which seem to stabilize this step compared to its otherwise similar mirror, [100]. In short, there are a number of opportunities where molecular scale imaging can provide new information that has the prospect to aid in optimizing calcium phosphate cements.

36 MATERIALS SCIENCE↗

Automated shaker placement and regularized input estimation for MIMO testing.

Multi-input, multi-output (MIMO) testing is used in component qualification to reproduce operational responses in the laboratory. It is often preferred to single-input and base-shake testing because of the potential for equivalent or better tests using smaller actuators and shorter test suites. Given a target response, two key steps in MIMO test design are selecting actuator locations and solving for input loads. Actuator locations are often manually selected using expert judgment. If an automatic method is used, locations are usually determined by simulating the vibration control problem and minimizing a combination of the input energy and control residuals. To select a configuration, the relative importance of input energy and residuals must be specified. Specifying relative weights is, in general, a manual and subjective process. This paper develops an objective function that compares actuator configurations based on control accuracy and required input energy without any manual parameter tuning. The objective function uses an optimally selected tradeoff parameter for each candidate configuration. To choose actuator locations using the new objective function, a pivoting algorithm for integer programming problems is developed. Starting with an initial configuration (such as the one generated by a greedy algorithm), the pivoting algorithm guarantees an objective function decrease in each iteration until convergence is reached. In a simulation featuring a structure excited by a diffuse acoustic field, electrodynamic shaker locations and regularized inputs are solved for without any analyst-specified parameters. Simulations are performed in MIMO configurations where the number of target responses is less than, equal to, and greater than the number of actuators.

Multi-input multi-output↗

Exploration Architecture with Quantum Inertial Gravimetry and In-Situ ChipSat Sensors

The Dual Exploration Architecture is a mission concept that combines remote sensing and in-situ observations into a single mission to answer planetary science questions that can only be answered with both types of data. Adoption of dual exploration architectures may short circuit the long, slow cycle of missions to inaccessible bodies by eliminating the need for separate precursor and follow-up missions. Additionally, the dual architecture possesses inherent flexibility that enables the design of adaptive, event-driven missions that are very different from traditional, largely pre-planned missions. Five key observations about the state and trends of planetary science exploration lead us to the dual architecture: increasing complexity of observations; scarcity of future mission opportunities; desire to capture transitory events; continued miniaturization of spacecraft components; and the Mars exploration cycle. Our goal in this study is to explore missions that can only happen using the dual architecture concept and find technology development needs that must be filled for those missions to compete. A survey of historical and current missions finds that opportunities for exploration are becoming less frequent, causing the flexibility and dual-nature elements of each mission to become more common. The dual exploration architecture takes these trends to their far conclusion, attempting to eliminate precursor and follow-up missions while still returning more scientific payoff. A study of the future of planetary science goals through the decadal survey reveals broad applicability of dual missions to solve mysteries that cannot be answered with a traditional mission architecture. These missions fall into three broad classes: choosing a local target from a global survey; dynamic/reactive science; and global in-situ networks. Two example missions of each class are notionally described. A deeper look at these dual architecture classes reveals four technology development needs that must be addressed for wide adoption of dual missions: passive landers; guided atmospheric probes; robust sensing packages; and small, precise orbital instruments. This study pursues a specific focus on two examples of such enabling technologies: the ChipSat and cold atom gravimetry. The ChipSat is a fully functional spacecraft-on-a-chip system that has broad versatility in the dual architecture mission space. Initial studies show that ChipSats could survive as passive impactor landers on bodies up to the size of Europa. Furthermore, COTS (Commercial Off-The-Shelf) components could provide an in-situ sensor suite that readily answers a number of pressing planetary science questions. Cold atom gravimetry uses inertial sensors based on light-pulse atom interferometry in a small form factor to map the gravity field of a body to precision equaling what would normally require two full spacecraft to achieve. The cold atom gravimeter provides an example of how advanced remote sensing capability can enable dual missions by providing greater returns in a significantly smaller package. Using the above two technologies, we study an example dual-architecture mission to both characterize and sample the subsurface oceans at Europa. The greatest scientific return in terms of detecting extraterrestrial life is in those regions where Europa’s ice crust is thin. The identification of regions with thin ice should therefore precede the selection of surface targets and dispatch of probes to those targets. This two-step process, if accomplished by separate flagship-scale missions, might take decades. As a result, a combined mission to both identify thin areas of Europa’s ice and follow up with surface observations at those regions is a good candidate for the dual-exploration architecture. This example mission consists of an orbiter spacecraft carrying a cold atom gravimeter capable of sensing or inferring the ice thickness on regional to local scales, along with a number of ChipSat probes capable of landing on the moon. The small size and weight of the ChipSats allows large numbers of them to be carried, ensuring that enough can be dropped to ensure survival of a minimum number of probes and potentially allowing for the in-situ sampling of multiple locations on the moon. The example missions and Europa case study show that amazing scientific return can obtained from dual-exploration architecture missions with a single launch by breaking the long timescales of planetary exploration and providing the flexibility to capturing transitory events and collect data across the local, regional, and global scales.

Exploration↗

Robotic path-finding in inverse treatment planning for stereotactic radiosurgery with continuous dose delivery

Purpose: Continuous dose delivery in radiation therapy treatments has been shown to decrease total treatment time while improving the dose conformity and distribution homogeneity over the conventional step-and-shoot approach. The authors develop an inverse treatment planning method for Gamma Knife® Perfexion™ that continuously delivers dose along a path in the target. Methods: The authors’ method is comprised of two steps: find a path within the target, then solve a mixed integer optimization model to find the optimal collimator configurations and durations along the selected path. Robotic path-finding techniques, specifically, simultaneous localization and mapping (SLAM) using an extended Kalman filter, are used to obtain a path that travels sufficiently close to selected isocentre locations. SLAM is novelly extended to explore a 3D, discrete environment, which is the target discretized into voxels. Further novel extensions are incorporated into the steering mechanism to account for target geometry. Results: The SLAM method was tested on seven clinical cases and compared to clinical, Hamiltonian path continuous delivery, and inverse step-and-shoot treatment plans. The SLAM approach improved dose metrics compared to the clinical plans and Hamiltonian path continuous delivery plans. Beam-on times improved over clinical plans, and had mixed performance compared to Hamiltonian path continuous plans. The SLAM method is also shown to be robust to path selection inaccuracies, isocentre selection, and dose distribution. Conclusions: The SLAM method for continuous delivery provides decreased total treatment time and increased treatment quality compared to both clinical and inverse step-and-shoot plans, and outperforms existing path methods in treatment quality. It also accounts for uncertainty in treatment planning by accommodating inaccuracies.

60 APPLIED LIFE SCIENCES↗

SU-F-J-66: Anatomy Deformation Based Comparison Between One-Step and Two-Step Optimization for Online ART

Purpose: This study investigated that how the quality of adapted plan was affected by inter-fractional anatomy deformation by using one-step and two-step optimization for on line adaptive radiotherapy (ART) procedure. Methods: 10 lung carcinoma patients were chosen randomly to produce IMRT plan by one-step and two-step algorithms respectively, and the prescribed dose was set as 60 Gy on the planning target volume (PTV) for all patients. To simulate inter-fractional target deformation, four specific cases were created by systematic anatomy variation; including target superior shift 0.5 cm, 0.3cm contraction, 0.3 cm expansion and 45-degree rotation. Based on these four anatomy deformation, adapted plan, regenerated plan and non-adapted plan were created to evaluate quality of adaptation. Adapted plans were generated automatically by using one-step and two-step algorithms respectively to optimize original plans, and regenerated plans were manually created by experience physicists. Non-adapted plans were produced by recalculating the dose distribution based on corresponding original plans. The deviations among these three plans were statistically analyzed by paired T-test. Results: In PTV superior shift case, adapted plans had significantly better PTV coverage by using two-step algorithm compared with one-step one, and meanwhile there was a significant difference of V95 by comparison with adapted and non-adapted plans (p=0.0025). In target contraction deformation, with almost same PTV coverage, the total lung received lower dose using one-step algorithm than two-step algorithm (p=0.0143,0.0126 for V20, Dmean respectively). In other two deformation cases, there were no significant differences observed by both two optimized algorithms. Conclusion: In geometry deformation such as target contraction, with comparable PTV coverage, one-step algorithm gave better OAR sparing than two-step algorithm. Reversely, the adaptation by using two-step algorithm had higher efficiency and accuracy as target occurred position displacement. We want to thank Dr. Lei Xing and Dr. Yong Yang in the Stanford University School of Medicine for this work. This work was jointly supported by NSFC (61471226), Natural Science Foundation for Distinguished Young Scholars of Shandong Province (JQ201516), and China Postdoctoral Science Foundation (2015T80739, 2014M551949).

60 APPLIED LIFE SCIENCES↗

Sinusoidal Siemens star spatial frequency response measurement errors due to misidentified target centers

Numerous methods are available to measure the spatial frequency response (SFR) of an optical system. A recent change to the ISO 12233 photography resolution standard includes a sinusoidal Siemens star test target. We take the sinusoidal Siemens star proposed by the ISO 12233 standard, measure system SFR, and perform an analysis of errors induced by incorrectly identifying the center of a test target. We show a closed-form solution for the radial profile intensity measurement given an incorrectly determined center and describe how this error reduces the measured SFR of the system. As a result, using the closed-form solution, we propose a two-step process by which test target centers are corrected and the measured SFR is restored to the nominal, correctly centered values.

79 ASTRONOMY AND ASTROPHYSICS↗

Similarity of Precursors in Solid-State Synthesis as Text-Mined from Scientific Literature

Collecting and analyzing the vast amount of information available in the solid-state chemistry literature may accelerate our understanding of materials synthesis. However, one major problem is the difficulty of identifying which materials from a synthesis paragraph are precursors or are target materials. In this study, we developed a two-step chemical named entity recognition model to identify precursors and targets, based on information from the context around material entities. Using the extracted data, we conducted a meta-analysis to study the similarities and differences between precursors in the context of solid-state synthesis. To quantify precursor similarity, we built a substitution model to calculate the viability of substituting one precursor with another while retaining the target. From a hierarchical clustering of the precursors, we demonstrate that the “chemical similarity” of precursors can be extracted from text data. Quantifying the similarity of precursors helps provide a foundation for suggesting candidate reactants in a predictive synthesis model.

36 MATERIALS SCIENCE↗

Ground-Based Localization of Mars Rovers

The document discusses a procedure for localizing the Mars rovers in site frame, a locally defined reference frame on the Martian surface. MER onboard position within a site frame is estimated onboard and is based on wheel odometry. Odometry estimation of rover position is only reliable over relatively short distances assuming no wheel slip, sinkage, etc. As the rover traverses, its onboard estimate of position in the current site frame accumulates errors and will need to be corrected on occasions via relocalization on the ground (mission operations). The procedure provides a systematic process for ground operators to localize the rover. The method focuses on analysis of acquired images used to declare a site frame and images acquired post-drive. Target selection is performed using two main steps. In the first step, the user identifies features of interest from the images used to declare the current site. Each of the selected target s position in site frame is recorded. In the second step, post-traverse measurements of the selected features positions are recorded again, this time in rover frame, using images acquired post-traverse. In the third step, we transform the post-traverse target s positions to local level frame. In the fourth step, we compute the delta differences in the pre- and post-traverse target s position. In the fifth step, we analyze the delta differences with techniques that compute their statistics to determine the rover s position in the site frame.

Trebi-Ollennu, Ashitey↗

Classifying and assembling two-dimensional X-ray laser diffraction patterns of a single particle to reconstruct the three-dimensional diffraction intensity function: resolution limit due to the quantum noise

A new algorithm is developed for reconstructing the high-resolution three-dimensional diffraction intensity function of a globular biological macromolecule from many quantum-noise-limited two-dimensional X-ray laser diffraction patterns, each for an unknown orientation. The structural resolution is expressed as a function of the incident X-ray intensity and quantities characterizing the target molecule. A new two-step algorithm is developed for reconstructing the three-dimensional diffraction intensity of a globular biological macromolecule from many experimentally measured quantum-noise-limited two-dimensional X-ray laser diffraction patterns, each for an unknown orientation. The first step is classification of the two-dimensional patterns into groups according to the similarity of direction of the incident X-rays with respect to the molecule and an averaging within each group to reduce the noise. The second step is detection of common intersecting circles between the signal-enhanced two-dimensional patterns to identify their mutual location in the three-dimensional wavenumber space. The newly developed algorithm enables one to detect a signal for classification in noisy experimental photon-count data with as low as ∼0.1 photons per effective pixel. The wavenumber of such a limiting pixel determines the attainable structural resolution. From this fact, the resolution limit due to the quantum noise attainable by this new method of analysis as well as two important experimental parameters, the number of two-dimensional patterns to be measured (the load for the detector) and the number of pairs of two-dimensional patterns to be analysed (the load for the computer), are derived as a function of the incident X-ray intensity and quantities characterizing the target molecule.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Genotyping‐in‐Thousands by sequencing (GT‐seq): A cost effective SNP genotyping method based on custom amplicon sequencing

Abstract Genotyping‐in‐Thousands by sequencing ( GT ‐seq) is a method that uses next‐generation sequencing of multiplexed PCR products to generate genotypes from relatively small panels (50–500) of targeted single‐nucleotide polymorphisms ( SNP s) for thousands of individuals in a single Illumina HiSeq lane. This method uses only unlabelled oligos and PCR master mix in two thermal cycling steps for amplification of targeted SNP loci. During this process, sequencing adapters and dual barcode sequence tags are incorporated into the amplicons enabling thousands of individuals to be pooled into a single sequencing library. Post sequencing, reads from individual samples are split into individual files using their unique combination of barcode sequences. Genotyping is performed with a simple perl script which counts amplicon‐specific sequences for each allele, and allele ratios are used to determine the genotypes. We demonstrate this technique by genotyping 2068 individual steelhead trout ( Oncorhynchus mykiss ) samples with a set of 192 SNP markers in a single library sequenced in a single Illumina HiSeq lane. Genotype data were 99.9% concordant to previously collected TaqMan ™ genotypes at the same 192 loci, but call rates were slightly lower with GT ‐seq (96.4%) relative to Taqman (99.0%). Of the 192 SNP s, 187 were genotyped in ≥90% of the individual samples and only 3 SNP s were genotyped in <70% of samples. This study demonstrates amplicon sequencing with GT ‐seq greatly reduces the cost of genotyping hundreds of targeted SNP s relative to existing methods by utilizing a simple library preparation method and massive efficiency of scale.

Campbell, Nathan R.↗

Transition Path Sampling Study of the Feruloyl Esterase Mechanism

Serine hydrolases cleave peptide and ester bonds and are ubiquitous in nature, with applications in biotechnology, in materials, and as drug targets. The serine hydrolase two-step mechanism employs a serine–histidine–aspartate/glutamate catalytic triad, where the histidine residue acts as a base to activate poor nucleophiles (a serine residue or a water molecule) and as an acid to allow the dissociation of poor leaving groups. This mechanism has been the subject of debate regarding how histidine shuttles the proton from the nucleophile to the leaving group. To elucidate the reaction mechanism of serine hydrolases, we employ quantum mechanics/molecular mechanics-based transition path sampling to obtain the reaction coordinate using the Aspergillus niger feruloyl esterase A (AnFaeA) as a model enzyme. The optimal reaction coordinates include terms involving nucleophilic attack on the carbonyl carbon and proton transfer to, and dissociation of, the leaving group. During the reaction, the histidine residue undergoes a reorientation on the time scale of hundreds of femtoseconds that supports the “moving histidine” mechanism, thus calling into question the “ring flip” mechanism. We find a concerted mechanism, where the transition state coincides with the tetrahedral intermediate with the histidine residue pointed between the nucleophile and the leaving group. Moreover, motions of the catalytic aspartate toward the histidine occur concertedly with proton abstraction by the catalytic histidine and help stabilize the transition state, thus partially explaining how serine hydrolases enable poor nucleophiles to attack the substrate carbonyl carbon. Rate calculations indicate that the second step (deacylation) is rate-determining, with a calculated rate constant of 66 s –1 . Altogether, these results reveal the pivotal role of active-site dynamics in the catalytic mechanism of AnFaeA, which is likely similar in other serine hydrolases.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tracker Toolkit

This software can track multiple moving objects within a video stream simultaneously, use visual features to aid in the tracking, and initiate tracks based on object detection in a subregion. A simple programmatic interface allows plugging into larger image chain modeling suites. It extracts unique visual features for aid in tracking and later analysis, and includes sub-functionality for extracting visual features about an object identified within an image frame. Tracker Toolkit utilizes a feature extraction algorithm to tag each object with metadata features about its size, shape, color, and movement. Its functionality is independent of the scale of objects within a scene. The only assumption made on the tracked objects is that they move. There are no constraints on size within the scene, shape, or type of movement. The Tracker Toolkit is also capable of following an arbitrary number of objects in the same scene, identifying and propagating the track of each object from frame to frame. Target objects may be specified for tracking beforehand, or may be dynamically discovered within a tripwire region. Initialization of the Tracker Toolkit algorithm includes two steps: Initializing the data structures for tracked target objects, including targets preselected for tracking; and initializing the tripwire region. If no tripwire region is desired, this step is skipped. The tripwire region is an area within the frames that is always checked for new objects, and all new objects discovered within the region will be tracked until lost (by leaving the frame, stopping, or blending in to the background).

Lewis, Steven J.↗

A method of dose reconstruction for moving targets compatible with dynamic treatments

Purpose: To develop a method that allows a commercial treatment planning system (TPS) to perform accurate dose reconstruction for rigidly moving targets and to validate the method in phantom measurements for a range of treatments including intensity modulated radiation therapy (IMRT), volumetric arc therapy (VMAT), and dynamic multileaf collimator (DMLC) tracking. Methods: An in-house computer program was developed to manipulate Dicom treatment plans exported from a TPS (Eclipse, Varian Medical Systems) such that target motion during treatment delivery was incorporated into the plans. For each treatment, a motion including plan was generated by dividing the intratreatment target motion into 1 mm position bins and construct sub-beams that represented the parts of the treatment that were delivered, while the target was located within each position bin. For each sub-beam, the target shift was modeled by a corresponding isocenter shift. The motion incorporating Dicom plans were reimported into the TPS, where dose calculation resulted in motion including target dose distributions. For experimental validation of the dose reconstruction a thorax phantom with a moveable lung equivalent rod with a tumor insert of solid water was first CT scanned. The tumor insert was delineated as a gross tumor volume (GTV), and a planning target volume (PTV) was formed by adding margins. A conformal plan, two IMRT plans (step-and-shoot and sliding windows), and a VMAT plan were generated giving minimum target doses of 95% (GTV) and 67% (PTV) of the prescription dose (3 Gy). Two conformal fields with MLC leaves perpendicular and parallel to the tumor motion, respectively, were generated for DMLC tracking. All treatment plans were delivered to the thorax phantom without tumor motion and with a sinusoidal tumor motion. The two conformal fields were delivered with and without portal image guided DMLC tracking based on an embedded gold marker. The target dose distribution was measured with a radiochromic film in the moving rod and compared with the reconstructed doses using gamma tests. Results: Considerable interplay effects between machine motion and target motion were observed for the treatments without tracking. For nontracking experiments, the mean 2 mm/2% gamma pass rate over all investigated scenarios was 99.6% between calculated and measured doses. For tracking experiments, the mean gamma pass rate was 99.4%. Conclusions: A method for accurate dose reconstruction for moving targets with dynamic treatments was developed and experimentally validated in a variety of delivery scenarios. The method is suitable for integration into TPSs, e.g., for reconstruction of the dose delivered to moving tumors or calculation of target doses delivered with DMLC tracking.

60 APPLIED LIFE SCIENCES↗

Real-time observation of DNA recognition and rejection by the RNA-guided endonuclease Cas9

Binding specificity of Cas9–guide RNA complexes to DNA is important for genome-engineering applications; however, how mismatches influence target recognition/rejection kinetics is not well understood. Here we used single-molecule FRET to probe real-time interactions between Cas9–RNA and DNA targets. The bimolecular association rate is only weakly dependent on sequence; however, the dissociation rate greatly increases from <0.006 s -1 to >2 s -1 upon introduction of mismatches proximal to protospacer-adjacent motif (PAM), demonstrating that mismatches encountered early during heteroduplex formation induce rapid rejection of off-target DNA. In contrast, PAM-distal mismatches up to 11 base pairs in length, which prevent DNA cleavage, still allow formation of a stable complex (dissociation rate <0.006 s -1 ), suggesting that extremely slow rejection could sequester Cas9–RNA, increasing the Cas9 expression level necessary for genome-editing, thereby aggravating off-target effects. We also observed at least two different bound FRET states that may represent distinct steps in target search and proofreading.

Science & Technology - Other Topics↗