Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tri-port”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Feed-Forward Compensation for Model Predictive Control in Tri-port Current-Source Medium-Voltage String Inverters for PV-Plus-Storage Farms

The novel tri-port current-source medium-voltage string inverter (TCS-MVSI) is a promising candidate for large-scale PV-plus-storage (PVS) farms owing to its galvanic isolation, easy storage integration, soft-switching capability across entire load range, controlled low dv/dt and EMI, benign fault tolerance, etc. Due to its low inertia feature, traditional PI-based control cannot manage large transients effectively. Instead, a model-based predictive control (MPC) is proposed to achieve robust and stable operation. As is well known, the control performance of MPC is compromised by the sampling and computational delay during implementation significantly, if not well addressed. This paper analyzed and quantified these delays and then proposes feed-forward compensation (FFC) for the MPC method to compensate the delays and the large parameter variations due to the low-inertia nature. In addition, this method also compensates for the high dc-link ripple within each switching cycle, a unique issue for low-inertia converters. Here, the proposed method requires low computational effort, allowing it to be extended for multiple ports. The effectiveness of the proposed method has been validated in experiments. In 10 kW test, the proposed method decreases the average dc-link current by 17%, leading to ~20% conduction losses and ~0.5% increase in converter efficiency. In addition, the peak dc-link current also decreases by 15%, resulting in reduced transformer size. As a result, an increased power density can be achieved with the proposed method. Similar improvements have been observed across the power range from 2 kW to 10 kW.

30 DIRECT ENERGY CONVERSION↗

A Tri-Port Current-Source Soft-Switching Medium-Voltage String Inverter for Large-Scale Solar-Plus-Storage Farms

This article presents a tri-port current-source soft-switching medium-voltage string inverter (TMVSI) to reduce the Levelized cost of energy (LCOE) of large-scale solar-plus-storage (SPS) farms. Throughout this work, the topology, operating principle, circuit simulation, control, and hardware design of the TMVSI are introduced. In addition, three key challenges compromising the performance of the TMVSI are addressed in this article. First, a new feed-forward compensation for model predictive control of the TMVSI is proposed to compensate for sampling and computational delay and high dc-link ripple with low computational cost and high scalability. Second, the use of laminated permanent magnets is proposed to reduce the losses of the MV medium-frequency transformer (MFT) in the TMVSI while increasing its saturation current. Finally, an improved U-shape winding pattern is proposed to decrease the leakage inductance of the MV MFT and reduce the voltage stress across semiconductor switches without adding cost or complexity. Here, the effectiveness of the TMVSI is validated by experiments at up to 20kW/500V in different test cases with custom-built prototypes. The contributions of this work make the TMVSI a viable solution to SPS farms and unleash its potential for LCOE reduction.

14 SOLAR ENERGY↗

Farm-level Interactions Study of a Novel Tri-port Soft-switching Medium-Voltage String Inverter (MVSI) based Large-scale PV-Plus-Storage Farms

A medium-voltage photovoltaic power conversion unit supported by battery based on a novel topology of soft switching solid state transformer is presented in this paper. It can reduce the Levelized Cost of Energy (LCOE) of PVS farm in an extended degree. However, its capability to provide grid-support services, such as frequency response, reactive power support, etc, have not been demonstrated. A series/parallel combination of these modules form a large 20 MVA solar farm. To validate them with reduced computation burden, a small-signal model of MVSI is firstly derived and validated in this paper. The model has been validated to match the full-switch model in both steady-state and dynamic conditions. Next, a farm-level simulation based on the proved small-signal model was implemented to demonstrate grid-support services. Real irradiation date from NREL is used to show the operational capabilities of the system. As a result, the overall farm is simulated based on MATLAB/Simulink domain to check the performance for various cases namely: power transfer from dc-ac side, reactive power support during grid voltage sag and utilization of battery during grid voltage disturbance or partial shading over PV panels.

14 SOLAR ENERGY↗

Modular Isolated Soft-Switching Medium Voltage String Inverter for Large-Scale PV Farm

This paper presents a single-stage modular isolated soft-switching medium voltage string inverter (MVSI) with tri-port configuration to interconnect PV and storage to medium voltage (MV) grid. The modular MVSI provides advanced functionalities such as energy storage elements integration without additional converters, connection to MV grid resulting in lower distribution losses in the PV farm, high-frequency galvanic isolation, independent control of PV, storage and grid power, high modularity and scalability. The topology of the MVSI, operation principle and model-predictive priority-switching (MPPS) control to achieve fast dynamic balancing across stacked modules are discussed. The independent power control is validated in PLECS simulation and the operation of stacked MVSI with MPPS control is verified through Hardware-in-the-loop (HIL) simulation. Here, the hardware prototype of 25 kVA MVSI building block is developed. 18 kW experimental results of single building block verifying tri-ports operation and 20 kW experimental results of two modules stacked operation are presented. A clean sinusoidal waveform with negligibly low THD in both tests is obtained. A low dv/dt of <; 1kV/us and soft-switching are achieved.

30 DIRECT ENERGY CONVERSION↗

Charge-Based Droop Control Addressing Control Saturation for Low-Inertia Converters

With bulky dc-link capacitors/inductors, traditional voltage-source converters (VSCs) and current-source converters (CSCs) feature a large inertia to facilitate the converter control under large transients. To achieve high power density with reduced cost, low-inertia converters (LICs) featuring significantly reduced dc-link capacitors/inductors have attracted growing attention. However, without bulky dc-link energy buffer, LICs are prone to control saturation under large transients, resulting in undesired oscillation and instability. This issue cannot be managed by traditional proportional-integral based control due to the low inertia. And it will deteriorate when several LICs are connected in series. To address this challenge in LICs, a model-predictive control (MPC) with a computation-inexpensive feed-forward compensation method has been proposed to provide fast dynamic responses. But it would suffer control saturation under larger transients that degrades the control performance. In this article, a charge-based droop control (CDC) is proposed to address this remaining challenge. This paper firstly analyzes the control saturation challenge in LICs by using a tri-port soft-switching solid-state transformer as an example. Next, the operating principle of the proposed CDC are introduced. Two different implementation approaches are discussed in detail. Lastly, the proposed scheme is validated in simulation with a high-fidelity model of hardware prototype. As a result, the proposed CDC eliminated the 2 kHz oscillation and reduced the dc-link ripple and overshoot due to control saturation by 75% and 50%, respectively.

30 DIRECT ENERGY CONVERSION↗