Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “trench”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Installation of Lysimeters Near Engineered Trench 3, Slit Trench 8, and Slit Trench 9

Nine new lysimeter stations were installed at the E-Area Low Level Waste Facility (ELLWF). Six lysimeter stations were installed near Engineered Trench 3 (ET3), one installed near Slit Trench 8 (ST8), and two installed near Slit Trench 9 (ST9) as shown in Figure ES-1. Two lysimeters were installed at each station at the depths shown in Table ES-1. Lysimeter placements were based on borehole lithology and were comparable to existing nearby lysimeter stations. The deepest lysimeter at each of the new lysimeter stations was designated as the action-level lysimeter. Following installation, the lysimeters were purged and placed under vacuum for sampling. Sampling occurred in April 2023. Analytical results from the sampling will be provided in the Spring 2023 Lysimeter Tritium Data technical memo and the 2023 Annual Summary Report. With the addition of the new lysimeters at ET3, ST8, and ST9, the vadose zone monitoring system is now comprised of 327 active lysimeters at 111 lysimeter stations. There are 102 action-level lysimeters at 111 stations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comoparison of Slit Trench and Engineered Trench 3D Vadose Zone Conceptual Models

In the next revision of the E-Area Low-Level Waste Facility (ELLWF) Performance Assessment (PA), radionuclide groundwater transport from slit (ST) and engineered trenches (ET) will be simulated using 3-dimensional PORFLOW models representing the vadose zone. In total, the conceptual framework will aim to model 29 total trenches with a degree of conservatism that provides a high level of confidence in meeting performance objectives. The implementation of generic conceptual models allows for a reasonable number of simulation scenarios, thereby reducing the chances of errors and enabling a better one-to-one comparison between the results, while still capturing the most important features of each trench. The current investigation seeks to understand if a generic trench model based on the general ET footprint can justifiably be used for representing both STs and ETs while maintaining a reasonable degree of conservatism. In this process, the groundwater transport of several key radionuclides was simulated for both ET and ST geometries and the flux-to-the-water-table profiles were compared. For all radionuclides simulated, the ET geometry is shown to be conservative (i.e., produces the highest peak flux to the water table).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Site Composite Analysis: Recharge and Inventory Sensitivity Analyses for the A Trenches, BC Cribs and Trenches, and PUREX Area Vadose Zone Models

The main objectives of the composite analysis (CA) compliance case vadose zone (VZ) facet are to simulate transport of radionuclide releases from the surface to the water table, and to provide radionuclide transfer rates to groundwater for inclusion into the Plateau-to-River (P2R) saturated zone (SZ) model (CP-57037, Model Package Report: Plateau to River Groundwater Model, Version 8.3). The CA compliance case approach to address the scale and distribution of contaminant sources in the VZ facet is to subdivide the Hanford Site Central Plateau into 26 models that contain contaminant sources and liquid discharges likely to commingle during migration through the VZ to the water table

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A tutorial on the micro-trench technique for incident ion angle, material erosion, and impurity deposition measurements at plasma-facing surfaces

The micro-trench method is a new technique to measure polar and azimuthal incident ion angles, material erosion, and impurity deposition at plasma-facing surfaces, and has been applied in the DIII-D divertor. This article gives a tutorial of the micro-trench technique consisting of six steps: (1) micro-trench fabrication, (2) pre-exposure measurement of the fabricated micro-trench geometry, (3) tracer material deposition, (4) plasma exposure, (5) post-exposure observation of the tracer material, and (6) post-exposure measurement of the micro-trench geometry. Two criteria need to be satisfied to apply the micro-trench method successfully: (i) uniform impurity deposition on the micro-trench floor, and (ii) erosion dominated by the physical sputtering induced by the impinging ions. Furthermore, when those two criteria are satisfied, post-exposure analysis of the impurity deposition patterns on the micro-trench floor may be used to determine the polar and azimuthal incident ion directions (mean values of the ion angle directions), erosion rate, and impurity deposition rate during plasma exposure without computational interpretation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vadose and Saturated Zone Flow and Transport Model Package Report for the Active Trenches of the Low-Level Burial Grounds, Hanford Site, Washington

This model package report (MPR) documents the development of the integrated vadose and saturated zone flow and transport model developed for the performance assessment of Trenches 31 and 34 in the low-level burial grounds (LLBGs). This modeling capability is intended for use in addressing the analysis requirements outlined in DOE O 435.1, Chg 1, Radioactive Waste Management1. The overall objective of the modeling effort is to provide a basis for making informed disposal decisions pertinent to Trenches 31 and 34. The purpose of the MPR is to document the development of the three-dimensional numerical vadose zone and saturated flow and transport model test case and evaluate its adequacy to support the LLBG performance assessment. The purpose is not to present results for DOE 435.1 decision making. The use of the model to perform base case and sensitivity analysis for the LLBG performance assessment, including inputs and results, is documented separately in subsequent environmental calculation files. This report discusses the development and translation of the conceptual model for flow and contaminant transport into the LLBG performance assessment three-dimensional numerical flow and transport model evaluated using the Subsurface Transport Over Multiple Phases (STOMP©) simulator. The development of representative geologic framework is described along with the implementation of waste release models used to represent contaminant release from waste disposed in the trenches. The report also provides the technical basis for specific model parameters and boundary conditions, along with description of modeling assumptions. This MPR includes certain calculations that are necessary to demonstrate the soundness of the model. Results provided by the model include vadose zone and saturated zone flow fields, and estimates of the possible future concentration in groundwater of technetium-99 and iodine-129 as example test cases. As an evaluation of the test cases, the model estimates of current vadose conditions are compared to available and analogous field and laboratory data, and compared to the results from the original performance assessment model (WHC-EP-0645, Performance Assessment for the Disposal of Low-Level Waste in the 200 West Area Burial Grounds 2 ). The features, events, and processes applicable to vadose zone and saturated zone flow and transport model are identified, and representative initial estimates for various parameters are documented. Note that the parameter estimates presented in this MPR are for illustration purposes, and may or may not reflect values selected for eventual performance assessment. Several key topical discussions (i.e., basis for recharge estimates, basis for vadose zone modeling, basis for saturated zone model development, and calibration) are included, which serve as the groundwork for confidence building for the groundwater pathway modeling and results. Numerical simulation results based on an example test case are included to illustrate the use of the combined saturated-unsaturated model in performance assessment calculations. Sensitivity and uncertainty results are not included in this MPR. Those results will be included in future environmental calculation files. The inclusion of the trapezoidal trench geometry and construction details in the finite difference grid introduces some gross simplifications regarding the trench and liner systems. The model test case presented in this MPR includes the assumption that the trench liner system does not affect flow through or around the trenches after the liner system is assumed to fail. This MPR also includes results of other test cases that involve alternate assumptions about how to incorporate the hydraulic effects of the trenches into the vadose zone of the model. These alternate cases do not attempt to account for the presence of the liner system after its assumed failure either. None of these cases is considered to be the base case at this time. Analysis and alternate cases that attempt to account for the presence of the liner system in greater detail, and its effect on flow through and around it, are to be documented in subsequent environmental calculation files. Depending on the results of those analyses and alternate cases, the eventual base case may involve more detailed inclusion of the effects of the liner system hydraulics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Assessment Maintenance Plan for the Active Low-Level Burial Ground Trenches 31, 34, and 94 at the Hanford Site

This report documents the maintenance plan for the Hanford Site 200 West Area Active Low-Level Burial Ground Trenches 31 and 34 and 200 East Area Active Trench 94 performance assessment (PA). The PA maintenance plan is one of several supporting documents that are compendiums to the active trenches (Trenches 31, 34, and 94) PA as required in DOE O 435.1, Radioactive Waste Management . The PA is documented in DOE/RL-2021-26, Performance Assessment of Active Trenches in 200 East and West Low-Level Burial Grounds at the Hanford Site . This plan follows the requirements and outline specified in the applicable U.S. Department of Energy (DOE) standard used for developing documents supporting DOE-STD-5002-2017, Disposal Authorization Statement and Tank Closure Documentation . This maintenance plan summarizes the following major activities DOE plans to conduct to maintain the Trenches 31, 34, and 94 PA: Monitoring; Research and development; Planned reviews and analyses; Revisions of Trenches 31, 34, and 94 PA. The planned research and development activities relate to evaluating the key assumptions, including evaluating conceptual model assumptions and parameter value assumptions used in the PA. The planned research and development activities include those that are designed to track the release mechanisms for Category 1, Category 3, and uranium billet waste sources, as well as continued characterization and related modeling of the natural environment in the Central Plateau of the Hanford Site. In addition, the planned research and development activities include focused testing and evaluation of engineered and natural materials to reduce the uncertainty in the conceptual models and parameter values used in the PA. All key and secondary issues identified during the review of the PA by the Low-Level Waste Disposal Facility Federal Review Group have been resolved prior to finalization of the PA. There are no outstanding issues.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Assessment of the Active Trenches in 200 East and 200 West Low-Level Burial Grounds at the Hanford Site

The purpose of this document is to provide the assessment of the long-term human health and environmental risk associated with the continued disposal of radioactive wastes in the active trenches of the 200 East and 200 West Area Low-Level Burial Grounds (LLBGs) at the Hanford Site (Figure ES-1), as required by DOE O 435.1, Radioactive Waste Management1. Since July 1, 2004, the only active trenches in the 200 West Area LLBGs are the lined Trenches 31 and 34 used for the disposal of containerized low-level waste and mixed low-level waste (Figure ES-2). The only active trench in the 200 East Area LLBGs is the unlined Trench 94 that was used for the disposal of naval reactor compartments (Figure ES-3). Trenches 31 and 34 are intended to be used until they reach their disposal capacity while Trench 94 will be used and expanded as necessary to meet the needs of the U.S. Navy.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vadose and Saturated Zone Flow and Transport Calculations for the Active Trenches of the Low-Level Burial Grounds, Hanford Site, Washington

The purpose of the fate and transport modeling described in this environmental calculation file (ECF) is to evaluate the impacts to groundwater associated with waste disposal operations at Mixed Waste Low-Level Burial Ground (LLBG) Trenches 31 and 34 to satisfy requirements in DOE O 435.1, Radioactive Waste Management. The model integrates the flow and transport in the vadose zone beneath the active trenches with the saturated zone downgradient of the trenches to predict the radionuclide concentration at the point of assessment (POA). DOE M 435.1-1, Radioactive Waste Management Manual, defines the POA as the point of highest projected dose or concentration beyond a 100 m (328 ft) buffer zone surrounding the disposed waste. The modeling is conducted in accordance with the DOE G 435.1, Implementation Guide for Use with DOE M 435.1-1, performance assessment (PA) guidelines. The modeling involves evaluation of the groundwater concentrations and radionuclide arrival times during the 1,000-year compliance and 10,000-year sensitivity-uncertainty periods per DOE O 435.1 and DOE M 435.1. This analysis does not consider radionuclide release during facility operations, only the post-closure impacts of the radionuclides to the environment. The evaluation of potential radiological dose to groundwater receptors caused by releases from a closed facility containing radioactive waste typically includes the following: (1) Release of radionuclides from that facility (2) Transport of those radionuclides through the environment, and (3) Exposure to humans to environmental concentration levels of those radionuclides The fate and transport three-dimensional (3D) model analysis involves the post-closure impacts to the environment of the technetium-99, iodone-129, and uranium (all isotopes in the waste). The residual inventory estimates include several radionuclides, but technetium-99 is typically responsible for almost all of the beta-gamma dose equivalent associated with groundwater (water resources) protection per 40 CFR 141, “National Primary Drinking Water Regulations” (e.g., see the results in WCH-520, Performance Assessment of Environmental Restoration Disposal Facility, Hanford Site, Washington; hereinafter referred to as the ERDF PA), and iodone-129 can also be a significant dose contributor for some waste (e.g., RPP-RPT-59958, Performance Assessment for the Integrated Disposal Facility, Hanford Site, Washington; hereinafter referred to as the IDF PA). Uranium does not typically factor significantly into the impacts to groundwater, even during the 10,000-year sensitivity-uncertainty period, but always remains of interest as a contaminant. This ECF does not address vadose and saturated zone modeling for Trench 94 of the 200 East Area LLBG. Current information confirms the validity of the low corrosion rate of the naval reactor plant carbon steel (HY-80), and the even lower corrosion rate of the nickel-iron-chromium alloy reactor vessel (Inconel Alloy 600) presented in DOE/EIS-0259, Final Environmental Impact Statement on the Disposal of Decommissioned, Defueled Cruiser, Ohio Class, and Los Angeles Class Naval Reactor Plants. Based on these low corrosion rates, the time to breach the reactor vessel to allow release of radionuclides from the activated metal of the reactor vessel internal structure is at least 10,000 years. This time to breach precludes the need to evaluate the vadose and saturated zone transport of contaminants released from the reactor compartment disposal packages in the 200 East Area LLBGs PA (CP-63826, Waste Release Model Package Report for the Active Trenches of the Low-Level Burial Grounds, Hanford Site, Washington).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Natural Systems Data Package for the Active Trenches of the Low-Level Burial Grounds, Hanford Site, Washington

This document summarizes the available information regarding the natural system (vadose zone and saturated zone) at the active trenches of the 200 West Area and 200 East Area Low-Level Burial Grounds (LLBGs). This information is relevant for developing the natural system fate and transport model for the update of the active trenches performance assessment. This document presents a description of the major features, events, and processes of the natural system at the active trenches of the 200 West Area and 200 East Area LLBGs that involves the geologic features or framework, and the vadose zone and groundwater flow and transport system. The description of the geologic features includes the following items: geologic setting, major structural features, major hydrostratigraphic units, and geologic framework. The discussion concerning vadose zone flow and transport at the active trenches of the 200 West Area and 200 East Area LLBGs includes the following topics: vadose zone features, events, and processes relevant to the development of the vadose zone conceptual model; hydrogeologic units and conditions; factors affecting moisture movement; and flow and transport properties of major units. The discussion concerning the groundwater flow and transport system in the vicinity of the active trenches of the 200 West Area and 200 East Area LLBGs includes the following topics: saturated zone features, events, and processes relevant to the saturated zone conceptual model; hydrogeologic units; groundwater flow conditions; and flow and transport properties.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Lateral and vertical growth of Mg-doped GaN on trench-patterned GaN films

Growth of Mg-doped GaN on trench-patterned GaN films consists of competing lateral and vertical growth fronts that result in regions with different electronic properties. Under typical growth conditions, lateral growth from the trench sidewall occurs at a faster rate than vertical growth from the trench base. When the trench width is sufficiently narrow, the growth fronts from opposite sidewalls coalesce and lead to eventual planarization of the top surface. Secondary electron imaging and cathodoluminescence mapping are used to correlate the morphology and the optical properties of regions resulting from lateral and vertical growth. For our growth conditions, the lateral-to-vertical growth rate ratio is found to be about 2.

Su, Po-Yi (ORCID:000000018339783X)↗

System Model Calculations for the Active Trenches of the Low-Level Burial Grounds, Hanford Site, Washington

Two lined trenches (Trench 31 and 34) located within the 200 West Low-Level Burial Ground (LLBG) area of the U.S. Department of Energy’s (DOE) Hanford Site are designated for permanent disposal of low-level radioactive waste (LLW) and mixed low-level radioactive waste (MLLW). In accordance with DOE O 435.1, Radioactive Waste Management, radioactive waste shall be managed and disposed in a manner that is protective of worker, public health and safety, and the environment. DOE O 435.1 requires a site-specific radiological performance assessment (PA) that includes calculations of potential releases and subsequent doses to members of the public for a period of 1,000 years after closure of a low-level waste (LLW) disposal facility. The purpose of this environmental calculation file (ECF) is to document the various dose calculations performed to support DOE’s LLBG PA. The dose assessments are performed to evaluate the potential exposure of an all-pathway representative person to radionuclide contaminants of potential concern (COPCs) that may be released from the LLBG Trenches 31 and 34 to the point of calculation (POC) located at the outer edge of a 100 m buffer zone surrounding the trench boundary. This ECF uses inputs from other ECFs and their associated model package reports (MPRs) supporting the LLBG PA. The five major objectives of this ECF are to present the results of the following: (1) Deterministic dose assessments for both groundwater and atmospheric exposure scenarios; (2) Radon-222 (Rn-222) flux emanating at the surface from the disposed wastes; (3) Uncertainty analyses of the groundwater pathway annual dose due to uncertainty in input parameters; (4) Sensitivity analyses of the input parameters that could potentially impact the fate and transport of the contaminants and doses; (5) Doses arising from inadvertent intruder exposure scenarios.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Surface 3D Electrical Resistivity Tomography Inversion of 2005 BC Cribs and Trenches Datasets

Hydrogeophysics, Inc. (HGI) conducted an electrical resistivity tomography (ERT) dataset at the BC Cribs and Trenches site, located in the Central Plateau of the Hanford Site. The 20 trenches and 6 cribs received large volumes of liquid inorganic waste in the 1950s, resulting in a large inventory of contaminants in the vadose zone. The objective of the ERT survey was to map plume extents resulting from the legacy discharges. The HGI interpretation of the resistivity data was performed using geometric inversion to interpolate 2D lines into a 3D image. To demonstrate a newly developed geophysical code capability (E4D), the resistivity data were re-processed to fit a full 3D model of the bulk electrical conductivity. This proof-of-concept model inversion was executed in calendar year 2011, as the large dataset was well-suited for the use of high-performance computing. The 3D re-processing of the BC Cribs and Trenches ERT data conducted in 2011 resolved the true bulk electrical conductivity. This means that all of the resistivity data were fit to a single model of the bulk electrical conductivity, with true horizontal and vertical dimensions. This differed from the HGI data interpretation approach that used geometric inversion to process 2D lines independently, which were then interpolated into a 3D image. Both the full 3D re-processing and the 2D interpolation to a 3D image demonstrated a higher electrical conductivity observed immediately beneath the trenches and cribs. The electrical conductivity is strongly correlated with nitrate concentrations, indicating the presence of nitrate and other co-located contaminants.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Assessment Closure Plan for the Active Low-Level Burial Ground Trenches 31, 34, and 94 at the Hanford Site

This report documents the closure plan for the active trenches within the Low-Level Burial Grounds of the Hanford Site, namely Trenches 31 and 34 in the 200 West Area and Trench 94 in 200 East Area. This closure plan is developed to meet the requirements of DOE O 435.1, Radioactive Waste Management. It is one of the several technical basis documents, along with the performance assessment (DOE/RL-2021-26, Performance Assessment of Active Trenches in 200 East and West Low-Level Burial Grounds at the Hanford Site), which is required for maintaining the Operating Disposal Authorization Statement as described in DOE-STD-5002-2017, Disposal Authorization Statement and Tank Closure Documentation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sapphire Substrate Trenching to Advance Superconducting High-Coherence Quantum Devices

Achieving longer coherence times in superconducting qubits is essential for advancing quantum information processing and enabling scalable quantum computing. This work presents an innovative fabrication strategy focused on sapphire trenching of the substrate of superconducting high-coherence quantum devices, developed by the SQMS Nanofabrication Taskforce in collaboration with the materials characterization team. In this talk, we present a method to efficiently and consistently trench into the sapphire substrate, without compromising the surface roughness or profile of the etched sapphire. In the literature, trenching in the substrate has been shown to decrease losses, unwanted coupling and thermal stress. Sapphire’s strong covalent bonds make it harder to etch compared to silicon, yet it is more favorable for high-coherence quantum devices due to its lower dielectric losses. This innovative technique opens new possibilities for superconducting qubit fabrication: we fabricated high coherence qubit chips on sapphire substrates with trenching, to demonstrate that it will help pushing towards higher coherence times. By integrating this work with ongoing junction process optimization, design innovation, materials characterization and exploration, we outline a clear pathway toward transmon coherence times reaching millisecond scales and beyond.

Garattoni, S. [Fermilab]↗

Sapphire Substrate Trenching to Advance Superconducting High-Coherence Quantum Devices

Achieving longer coherence times in superconducting qubits is essential for advancing quantum information processing and enabling scalable quantum computing. This work presents an innovative fabrication strategy focused on sapphire trenching of the substrate of superconducting high-coherence quantum devices, developed by the SQMS Nanofabrication Taskforce in collaboration with the materials characterization team. In this talk, we present a method to efficiently and consistently trench into the sapphire substrate, without compromising the surface roughness or profile of the etched sapphire. In the literature, trenching in the substrate has been shown to decrease losses, unwanted coupling and thermal stress. Sapphire’s strong covalent bonds make it harder to etch compared to silicon, yet it is more favorable for high-coherence quantum devices due to its lower dielectric losses. This innovative technique opens new possibilities for superconducting qubit fabrication: we fabricated high coherence qubit chips on sapphire substrates with trenching, to demonstrate that it will help pushing towards higher coherence times. By integrating this work with ongoing junction process optimization, design innovation, materials characterization and exploration, we outline a clear pathway toward transmon coherence times reaching millisecond scales and beyond.

Garattoni, S. [Fermilab]↗

Investigation on gate oxide reliability under gate bias screening for commercial SiC planar and trench MOSFETs

This paper evaluates the impact of the fast high gate-voltage screening technique on gate oxide reliability of commercial 1.2 kV 4H-SiC power metal-oxide-semiconductor field-effect transistors (MOSFETs) with planar and trench gate structures. The measurements are conducted on packaged devices with the intent that the results will be applicable to wafer-level screening. The threshold voltage (V th ) of SiC MOSFETs is measured before and after various screening treatments and recovery process. In addition, constant-voltage time-dependent dielectric breakdown (TDDB) measurements are performed on SiC MOSFETs to obtain the intrinsic lifetime of gate oxide. The objective of this study is to determine the optimal screening conditions and improve screening efficiency without degradation of gate oxide reliability, such as V th shift and reduced oxide intrinsic lifetime. Due to the differences in the gate oxidation process and structural design of SiC planar and trench MOSFETs, the two types of devices exhibit different oxide reliability in the screening process. The recommended screening conditions obtained in this paper reveal that SiC trench MOSFETs can accept higher screening voltages compared to SiC planar MOSFETs. Hence, it can be concluded that more efficient screening techniques can be adopted for SiC MOSFETs with thicker gate oxide to meet the requirements of industrial applications.

36 MATERIALS SCIENCE↗

Micro-trench measurements of the net deposition of carbon impurity ions in the DIII-D divertor and the resulting suppression of surface erosion

In this work, we report carbon impurity ion incident angles and deposition rates, along with silicon erosion rates, from measurements of micro-engineered trenches on a silicon surface exposed to L-mode deuterium plasmas at the DIII-D divertor. Post exposure ex-situ analysis determined elemental maps and concentrations, carbon deposition thicknesses, and erosion of silicon surfaces. Carbon deposition profiles on the trench floor showed carbon ion shadowing that was consistent with ERO calculations of average carbon ion angle distributions (IADs) for both polar and azimuthal angles. Measured silicon net erosion rates negatively correlated with the deposited carbon concentration at different locations. Differential erosion of surfaces on two different ion-downstream trench slope structures suggested that carbon deposition rate is affected by the carbon ion incident angle and significantly suppressed the surface erosion. The results suggest the C impurity ion incident angles, determined by the IADs and surface morphology, strongly affect erosion rates as well as the main ion (D, T, He) incident angles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diffused trenches for high fill-factor Low-Gain Avalanche Diodes

Low-Gain Avalanche Diodes (LGADs) are a class of silicon detectors that have been specifically designed for the fast detection of minimum ionizing particles (mips) in High-Energy Physics experiments. While they provide timing resolution on the order of a few tens of picoseconds, they cannot achieve high spatial resolution due to the intrinsic characteristics of their structures. Thus, active R&D is on-going to develop detectors based on LGADs to improve their spatial resolution while maintaining the timing performance of the LGADs. Such devices are, for example, AC-coupled LGADs and Deep-Junction LGADs. Another device option is the Trench-Isolated LGAD (TI LGAD), where trenches etched at the periphery of the pixels isolate them while providing a high fill-factor. Here, in this paper, we present a variation of this latter approach, demonstrating its feasibility by means of 2-dimensional TCAD simulations.

47 OTHER INSTRUMENTATION↗