Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transport protocols”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Shape-shifting Elephants: Multi-modal Transport for Integrated Research Infrastructure

Data Acquisition (DAQ) workloads form an important class of scientific network traffic that by its nature (1) flows across different research infrastructure, including remote instruments and supercomputer clusters, (2) has ever-increasing throughput demands, and (3) has ever-increasing integration demands---for example, observations at one instrument could trigger a reconfiguration of another instrument. Today's DAQ transfers rely on UDP and (heavily tuned) TCP, but this is driven by convenience rather than suitability. The mismatch between Internet transport protocols and scientific workloads becomes more stark with the steady increase in link capacities, data generation, and integration across research infrastructure.This position paper argues the importance of developing specialized transport protocols for DAQ workloads. It proposes a new transport feature for this kind of elephant flow: multi-modality involves the network actively configuring the transport protocol to change how DAQ flows are processed across different underlying networks that connect scientific research infrastructure. Multi-modality is a layering violation that is proposed as a pragmatic technique for DAQ transport protocol design. It takes advantage of programmable network hardware that is increasingly being deployed in scientific research infrastructure. The paper presents an initial evaluation through a pilot study that includes a Tofino2 switch and Alveo FPGA cards, and using data from a particle detector.

97 MATHEMATICS AND COMPUTING↗

100 Gb/s High Throughput Serial Protocol (HTSP) for data acquisition systems with interleaved streaming

Demands on Field-Programmable Gate Array (FPGA) data transport have been increasing over the years as frame sizes and refresh rates increase. As the bandwidths requirements increase the ability to implement data transport protocol layers using "soft" programmable logic becomes harder and start to require harden IP blocks implementation. To reduce the number of physical links and interconnects, it is common for data acquisition systems to require interleaving of streams on the same link (e.g. streaming data and streaming register access). Further, this paper presents a way to leverage existing FPGA harden IP blocks to achieve a robust, low latency 100 Gb/s point-to-point link with minimal programmable logic overhead geared towards the needs of data acquisition systems with interleaved streaming requirements.

47 OTHER INSTRUMENTATION↗

Cross-domain digital twin architecture for predictive maintenance via machine learning and Large Language Models

This research introduces a comprehensive framework for creating and deploying a digital twin platform for continuous monitoring and predictive maintenance within industrial settings. Through utilizing advanced technologies, including Unreal Engine 5, Unity 3D, the Message Queue Telemetry Transport protocol, Random Forest machine learning algorithms, and Large Language Models (LLMs), we establish a platform that digitally reproduces physical equipment and translates digital controls into real-world actions. This facilitates preventive maintenance approaches and improves operational effectiveness. The digital twin platform gathers sensor data from operational equipment, analyzes it using machine learning, and delivers practical insights to prevent potential malfunctions and enhance equipment performance. Furthermore, the incorporation of a web portal enables efficient monitoring and access to historical data, educational materials, and equipment status information. Preliminary findings indicate that digital twins can transform industrial equipment management and maintenance methodologies.

97 MATHEMATICS AND COMPUTING↗

Charge carrier extraction and recombination effects in GaInAs/GaAsP multi-quantum well solar cells

The carrier extraction and transport mechanisms as well as the relative contributions of radiative and non-radiative recombination processes are investigated in high-quality strain-balanced GaInAs/GaAsP multi-quantum well solar cells recently implemented in record efficiency multijunction solar cells. A comprehensive suite of complementary characterization techniques including temperature- and suns-dependent photoluminescence and photovoltaic measurements are employed to analyze thermal escape and tunneling rates, which demonstrate the need to move beyond simple drift-diffusion models of p–n junctions. This study examines the processes that best characterize the operation of these devices across varying temperatures using a simple two-diode model, incorporating multiple transport protocols, and provides insights into the performance-limiting processes and pathways for their optimization.

14 SOLAR ENERGY↗

JANUS: Resilient and Adaptive Data Transmission for Enabling Timely and Efficient Cross-Facility Scientific Workflows

In modern science, the growing complexity of large-scale scientific projects has led to an increasing reliance on cross-facility scientific workflows, where resources and expertise from multiple institutions and geographic locations are leveraged to accelerate scientific discovery. These workflows often require transmitting huge amounts of scientific data through wide-area networks. Although high-speed networks like ESnet and transfer services such as Globus have improved data mobility, several challenges remain. The sheer volume of data can overwhelm network bandwidth, widely used transport protocols such as TCP suffer from inefficiencies due to retransmissions triggered by packet loss, and existing fault-tolerance mechanisms like erasure coding introduce substantial overhead. In this paper, we propose Janus, a resilient and adaptable data transmission approach designed for cross-facility scientific workflows. Unlike traditional TCP-based methods, Janus leverages UDP, integrates erasure coding for fault tolerance, and combines it with error-bounded lossy compression to reduce overhead. This novel design allows users to balance data transmission time and accuracy, optimizing transfer performance based on specific scientific requirements. Additionally, Janus dynamically adjusts erasure coding parameters in response to real-time network conditions, ensuring efficient data transfers even in fluctuating environments. We develop optimization models for determining ideal configurations and implement adaptive data transfer protocols to enhance reliability. Through extensive simulations and real-network experiments, we demonstrate that Janus significantly improves transfer efficiency while maintaining data fidelity.

Esaulov, Vladislav [Georgia State University, Atla↗

Message-Based SPDK Transport Utility (TED Report) [Slides]

The driving goal is to investigate the feasibility of a message-based data transport for SPDK. All of SPDK’s existing data transport protocols are “connection-based”, requiring a target to hold state for each connected client / initiator. At extreme scale, juggling these connections from a large number of initiators creates a performance bottleneck. Under a message-based paradigm, we can bypass this behavior, as all initiators share a global communication channel, held open for the entire run. In theory, this approach should minimize connection management overhead at extreme scale.

97 MATHEMATICS AND COMPUTING↗

Unified, Geometric Framework for Nonequilibrium Protocol Optimization

Controlling thermodynamic cycles to minimize the dissipated heat is a long-standing goal in thermodynamics, and more recently, a central challenge in stochastic thermodynamics for nanoscale systems. Here, we introduce a theoretical and computational framework for optimizing nonequilibrium control protocols that can transform a system between two distributions in a minimally dissipative fashion. These protocols optimally transport a system along paths through the space of probability distributions that minimize the dissipative cost of a transformation. Furthermore, we show that the thermodynamic metric—determined via a linear response approach—can be directly derived from the same objective function that is optimized in the optimal transport problem, thus providing a unified perspective on thermodynamic geometries. As a result, we investigate this unified geometric framework in two model systems and observe that our procedure for optimizing control protocols is robust beyond linear response.

36 MATERIALS SCIENCE↗

Precision Time Protocol Performance Testing Over Optical Transport Network

The US Department of Energy Office of Electricity has partnered with Oak Ridge National Laboratory (ORNL) to find alternative precision timing solutions for the nation’s power grid. This effort is in response to the vulnerabilities identified in the Global Navigation Satellite System (GNSS), of which the US Global Positioning System (GPS) platform is a part. Additionally, Executive Order 139055 has highlighted the need for alternative or backup timing solutions. ORNL has established a Timing Lab and has been testing various technologies and timing devices as part of this effort. Precision Time Protocol (PTP), and the off-the-shelf timing devices and network connections that support it, are among the alternatives being tested. This work reports the accuracy of PTP over an Optical Transport Network (OTN) and is part of a series published by the Center for Alternative Synchronization and Timing (CAST).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Network traffic control for multi-homed end-hosts via SDN

Software-defined networking (SDN) is an emerging technology of efficiently controlling and managing computer networks, such as in data centres, wide-area networks, as well as in ubiquitous communication. In this study, the authors explore the idea of embedding the SDN components, represented by SDN controller and virtual switch, in end-hosts to improve network performance. In particular, the authors consider load balancing across multiple network interfaces on end-hosts with different link capacity scenarios. The authors have explored and implemented different SDN-based load-balancing approaches based on OpenFlow software switches, and have demonstrated the feasibility and the potential of this approach. The proposed system has been evaluated with MultiPath transmission control protocol (MPTCP). Furthermore, the proposed results demonstrated the potential of applying the SDN concepts on multi-homed devices resulting in an increase in achieved throughput of 55% compared to the legacy single network approach and 10% compared to the MPTCP.

97 MATHEMATICS AND COMPUTING↗

Protocols and methodologies for acquiring and analyzing critical-current versus longitudinal-strain data in Bi 2 Sr 2 CaCu 2 O 8+x wires

Abstract In the literature on Bi 2 Sr 2 CaCu 2 O 8+ x (Bi-2212) superconducting wires, it is evident that measurement protocols for transport critical-current I c versus longitudinal strain ϵ and definitions of the so-called ‘strain limit’ are generally dissimilar. Yet, values obtained for the ‘strain limit’ are frequently assimilated to being those of the irreversible strain limit ϵ irr , regardless of the I c degradation-criterion used to define it. In effect, ϵ irr should correspond specifically to the I c ( ϵ ) irreversibility onset , where crack formation in Bi-2212 filaments presumably starts. Because I c ( ϵ ) degradation remains progressive over a fairly wide strain range beyond ϵ irr , the different I c degradation-criteria in use do not yield to the same result and, thus, are not equivalent from metrology perspective. Indeed, in studying densified samples of a modern Bi-2212 round wire, we found ϵ irr ≈ 0.4% and ϵ 5% ≈ 0.6% ( ϵ 5% being the strain where I c degrades by 5%). In this paper, we outline and suggest I c ( ϵ )-measurement protocols and data-analysis methodologies in the hope to converge the various approaches taken for studying Bi-2212 strain properties and, thus, remove related result discrepancies. A unified approach would enable more objective data comparisons among laboratories and among different Bi-2212 conductors. It would pave the way for more rigorous studies of effects potentially associated with wire design, powder, heat treatments, and other such parameters on the conductor’s strain properties.

protocols↗

Identifying Majorana vortex modes via nonlocal transport

The combination of two-dimensional Dirac surface states with s-wave superconductivity is expected to generate localized topological Majorana zero modes in vortex cores. Putative experimental signatures of these modes have been reported for heterostructures of proximitized topological insulators, iron-based superconductors or certain transition metal dichalcogenides. Despite these efforts, the Majorana nature of the observed excitation is still under debate. In this work, we propose to identify the presence of Majorana vortex modes using a nonlocal transport measurement protocol originally employed for one-dimensional settings. In the case of an isolated subgap state, the protocol provides a spatial map of the ratio of local charge- and probability-density which offers a clear distinction between Majorana and ordinary fermionic modes. We show that these distinctive features survive in the experimentally relevant case of hybridizing vortex core modes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Shuttling Majorana zero modes in disordered and noisy topological superconductors

The braiding of Majorana zero modes (MZMs) forms the fundamental building block for topological quantum computation. Braiding protocols which involve the physical exchange of MZMs are typically envisioned on a network of topological superconducting wires. An important component of these protocols is the transport of MZMs, which can be performed by using electric gates to locally tune sections of the wire between topologically trivial and nontrivial phases. In this work, we numerically simulate this transport by tuning a single section of a superconducting wire which contains either disorder (uncorrelated and correlated) or noise. We focus on the impact of these additional effects on the diabatic error, which describes unwanted transitions between the ground state and excited states. We show that the behavior of the average diabatic error is predominantly controlled by the statistics of the minimum bulk energy gap which is suppressed in the presence of disorder. The increase in diabatic error can be several orders of magnitude and is most deleterious when the disorder correlation length is a finite fraction of the transport distance and negligible when these lengths are far apart. In the presence of noise, the diabatic error is significantly enhanced due to optical transitions which depend on the minimum bulk energy gap as well as the frequency modes present in the noise. The results presented here serve to further characterize the diabatic error in disordered and noisy settings, which are important considerations in practical implementations of physical braiding schemes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Universal energy-speed-accuracy trade-offs in driven nonequilibrium systems

The connection between measure theoretic optimal transport and dissipative nonequilibrium dynamics provides a language for quantifying nonequilibrium control costs, leading to a collection of thermodynamic speed limits, which rely on the assumption that the target probability distribution is perfectly realized. This is almost never the case in experiments or numerical simulations, so here we address the situation in which the external controller is imperfect. We obtain a lower bound for the dissipated work in generic nonequilibrium control problems that (1) is asymptotically tight and (2) matches the thermodynamic speed limit in the case of optimal driving. Along with analytically solvable examples, we refine this imperfect driving notion to systems in which the controlled degrees of freedom are slow relative to the nonequilibrium relaxation rate, and identify independent energy contributions from fast and slow degrees of freedom. Furthermore, we develop a strategy for optimizing minimally dissipative protocols based on optimal transport flow matching, a generative machine learning technique. Furthermore, this latter approach ensures the scalability of both the theoretical and computational framework we put forth. Crucially, we demonstrate that we can compute the terms in our bound numerically using efficient algorithms from the computational optimal transport literature and that the protocols we learn saturate the bound.

59 BASIC BIOLOGICAL SCIENCES↗

Motional Squeezing for Trapped Ion Transport and Separation

Transport, separation, and merging of trapped ion crystals are essential operations for most large-scale quantum computing architectures. In this Letter, we develop a theoretical framework that describes the dynamics of ions in time-varying potentials with a motional squeeze operator, followed by a motional displacement operator. Using this framework, we develop a new, general protocol for trapped ion transport, separation, and merging. We show that motional squeezing can prepare an ion wave packet to enable transfer from the ground state of one trapping potential to another. Here, the framework and protocol are applicable if the potential is harmonic over the extent of the ion wave packets at all times. As illustrations, we discuss two specific operations: changing the strength of the confining potential for a single ion and separating same-species ions with their mutual Coulomb force. Both of these operations are, ideally, free of residual motional excitation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗