Engineering PapersSearch

SEARCH · Engineering Papers

Results for “transmission line protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

End-To-End Decentralized Transmission Line Protection in IBR-Dominated Weak Grids Using Interpretable Data-Driven Methods

Traditional transmission line protection relies on predictable synchronous-based fault signatures, which frequently fail under the non-standard, current-limited fault characteristics of Inverter-Based Resources (IBRs). This study investigates how to achieve secure, communication-free fault isolation in IBR-dominated weak grids without relying on opaque, computationally heavy "black-box" machine learning algorithms. To address this, we propose a novel, standalone, and inherently interpretable data-driven protection framework. Unlike centralized methods requiring multi-terminal communication, this decentralized approach relies solely on local measurements using a hierarchical linear-kernel Support Vector Machine (SVM). The methodology decomposes the protection task into four sequential stages that mimic traditional protection elements: fault detection and fault direction identification, fault type classification, zone classification, and location estimation. This multi-stage architecture allows for specialized feature engineering at each stage, combining high computational efficiency with logic traceability. The framework's end-to-end performance was validated via C-code and PSCAD/EMTDC co-simulation, utilizing a real-world utility network and an OEM black-box IBR model. The proposed relay achieves 97.2% overall accuracy and provides a reliable trip decision within a 2.5-cycle window. The results confirm 100% accuracy in fundamental fault detection, reliable zone selectivity across low to moderate fault resistances, and robust security against non-fault transients, proving its immediate viability for integration into commercial numerical relays.

24 POWER TRANSMISSION AND DISTRIBUTION

Gyromagnetic nonlinear transmission line for radio frequency signal generation and pulse compression

Disclosed are non-linear transmission lines using ferromagnetic materials to generate ferromagnetic resonance oscillations. In one aspect, a non-linear transmission line apparatus is disclosed. The apparatus includes an outer conductor having a first side and a second internally facing side, and an inner conductor positioned internal to the non-linear transmission line apparatus. The apparatus further includes a ferromagnetic material surrounding the inner conductor, wherein the ferromagnetic material comprises nanoparticles of an ε-polymorph of iron oxide expressed as ε-Fe2O3. The apparatus also includes a first dielectric material positioned between the outer conductor and the inner conductor, the dielectric material in contact with both the ferromagnetic material and with the second internally facing side of the outer conductor, wherein the outer conductor, the inner conductor, the dielectric material and the ferromagnetic material form the nonlinear transmission line.

Schneider, Joseph Devin

Utility Experience with Inverter Based Resource Impacts on Transmission Protection

High penetration of inverter-based resources (IBR) can adversely affect the transmission protection schemes in the area. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems because the existing system has been designed based on the fault current response of conventional rotating-machine-based generators. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. It includes a broad review of all challenges that system protection has experienced so far with high penetration of IBRs. Key issues have been identified based on a survey of different utility protection engineers. Finally, fault event recordings are shown to demonstrate some actual cases of mis-operations of relays near IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION

Quality and Loss Factor Characterization of YBCO Superconducting Transmission Lines for Axion Dark Matter Detection

Axion haloscope experiments aim to detect the conversion of axions into microwave photons under a strong magnetic field through resonant cavity techniques. The conversion produces an extremely small signal, requiring a cryogenic environment to reduce thermal noise, and low-loss superconducting transmission lines for minimal attenuation in the readout chain. Yttrium barium copper oxide (YBCO) cables are a promising candidate. Unlike commonly used low-loss cryogenic cables such as niobium (Nb) and niobium titanium (NbTi), which have low critical fields, YBCO is a high-temperature superconductor that can remain stable in strong magnetic fields. We characterized the quality and loss of five stripline resonators from the Brookhaven Technology Group: three YBCO, a copper reference, and a silver reference. Experimental methodology included collecting scattering parameter data on a vector network analyzer for the samples at 77 K along with room temperature baseline measurements, and employing both Lorentzian-fit and circle-fitting techniques to confirm the coupling regime and corroborate results. We achieved quality factors on the order of $10^3$ with corresponding loss factors on the order of $10^{-1}$ dB/m. Trends were comparable with literature data on Nb and NbTi at 4 K, which did have lower loss under these conditions, but suggested similar or perhaps better loss for YBCO when accounting for the temperature difference. We also developed a cryogenic probe for future measurements in a 14 T applied field at 30 mK. This will serve to directly evaluate YBCO's durability in magnetic fields, and we expect significantly improved performance at millikelvin temperatures.

Marinos, Z. [UCLA]

Quantifying the dislocation content of atomically resolved grain boundary line defects using the Nye tensor

The Nye tensor, which quantifies the density of Burgers vector for a given dislocation line direction, can be effectively used to characterize dislocation content in bulk crystals from atomic-resolution transmission electron microscopy images. The Nye tensor can be calculated from these images, in part because the reference state is simply defined by the lattice of the perfect crystal. The application of the Nye tensor to interfacial line defects, for which the natural reference state is the dichromatic pattern of the two grains in their reference orientation, poses additional challenges. In this work, we present a method that employs the Nye tensor to characterize the edge dislocation content of line defects at grain boundaries from atomic-resolution images. This approach enables us to rapidly characterize all edge dislocation content along a grain boundary. Additionally, the Nye tensor provides information about line defect core structure. Finally, we demonstrate this method on two exemplar defects: a twin boundary disconnection and a facet junction in face-centered cubic Au.

Crystallographic defects

A Novel Protection Scheme for Unbalanced Faults in Inverter Dominated Networks: A Computationally Efficient Algorithm for Entry-Level Relays

Microgrids are now a common practice in distribution systems to increase resilience and reliability. However, microgrid protection remains a critical challenge, considering its requirement to operate in both grid connected and islanded, and the variability in fault characteristics under each mode of operation. This paper presents unbalanced power (S unb ) based fault detection algorithm, which considers local voltage and current unbalances to determine faults in the system. S unb is a computationally efficient fault detection algorithm that is suitable for implementation in the programmable logic of entry level protective relays. In addition, the difference in current and voltage unbalance (D n ) is used to determine the fault type. The proposed method demonstrates high sensitivity and selectivity for line-to-ground (LG), line-to-line (LL), and double line-to-ground (LLG) faults, representing the most common faults in distribution systems. It also allows relay coordination with upstream and downstream protection devices in both island and grid connected operation, while preserving grading margins. The same pickup and time multiplier settings of a particular relay for both modes of operation eliminates the need for adaptive settings, which rely on communication networks. Validation was performed with a hardware-in-the-loop (HIL) setup using Typhoon HIL real time simulator interfaced with three entry-level, SEL 751 relays. Results confirmed the algorithm’s ability to discriminate fault conditions, and determine the fault type under both operating modes, maintain fast detection times, and ensure proper protection coordination.

fault classification

Utilities Perspective on Protection Challenges with High IBR Penetration

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, we are looking broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the presentation summarizes on gathered data and internal experiences.

24 POWER TRANSMISSION AND DISTRIBUTION

A Sensitivity-driven Wide Area Protection (SWAP) Coordination Tool for High Penetration of Inverter-based Resources (IBR)

Traditionally, power system generation sources have been composed of synchronous generators, of which the fault current behavior is understood with minimal differences between generation size and types due to the physics of their construction. Present protection schemes and modeling methods are based upon these understood characteristics. Most renewable generation is composed of inverter-based resources (IBR), in which fault current is determined by switching control software and hardware limitations, each of which can vary between manufacturers and even between models of the same manufacturer. The resulting fault current is low in magnitude, low in negative-sequence current, unpredictable phase angles, and is a challenge to model. These characteristics also result in a challenge to traditional protection schemes and fault simulation software. To address several of these concerns, the project has the following goals: 1. Improve IBR models: Improve IBR models used in short circuit (SC) programs to accurately capture the response of IBRs at the bulk power system (BPS) level for fault and protection studies. 2. Develop automation tool: Develop an automation tool that allows engineers to identify protection coordination and sensitivity issues by performing SC and protection coordination studies in a high IBR-penetrated grid by applying variations to the IBR models, faults, contingencies, etc. 3. Develop schemes: Develop new protection mitigation solution schemes that complement the existing protection systems to ensure safe operation of the BPS with higher IBR penetration levels. The project team did not achieve this final goal, as the Department of Energy (DOE) stopped the project early due to changes in DOE funding priorities. The termination notice came at the beginning of the final project phase, while the team was identifying and beginning to investigate protection issues. It should be noted that the team discussed a 100% penetration scenario. However, this scenario would require the use of grid-forming IBR models that are not presently available. Since developing these models requires additional effort, the 100% penetration scenario was not pursued during this project. In the future, developing the methodology and models for the 100% scenario could benefit the industry.

14 SOLAR ENERGY

Electric spiking activity in epithelial cells

Epithelial cells (human keratinocyte cells and the canine MDCK cell line), traditionally viewed as electrically non-self-excitable and involved primarily in physiological functions such as barrier presentation, absorption, secretion, and protection, are shown here to exhibit traveling extracellular electric charge when they recover from spatially focused, laser-induced wounding of confluent monolayers cultured on a multielectrode array chip. Voltage spikes measured on these electrodes display depolarization, repolarization, and hyperpolarization phases with amplitudes similar to the action potentials of neurons but with the markedly slower duration of 1 to 2 s. Some propagate distances up to hundreds of μm from the wound with a mean speed of around 10 mm s −1 . Generation and transmission of bioelectric signals are significantly influenced by the perturbation of mechanosensitive cationic ion channels. These direct measurements confirm bioelectric signaling that previous work has hypothesized to regulate epithelial cell development and may have relevance to the frequency parameter selection of bioelectric devices.

Science & Technology - Other Topics

Spacecraft Radiator Protection from Ionizing Radiation, Dust, and Excessive Heat Loss

Under a Phase II SBIR project funded by NASA Johnson Space Center (Contract No. 80NSSC25C0088), Analytical Scientific Products LLC (ASP) has been developing an actively controlled louver to protect spacecraft radiators from degradation due to exposure to various types of environmental conditions. Of particular interest are ionizing radiation during spacecraft transit through the Van Allen belts, dust during spacecraft landing and surface operations on the moon, and excessive heat loss during the long lunar night especially near the poles where the local ambient temperatures can drop below -200°C. Exposure to ionizing radiation and dust can degrade the optical properties of the radiator coating that in turn reduces its ability to reject excess heat from the spacecraft into the environment. Exposure to the extremely low temperature conditions during the lunar night near the poles can freeze the radiator fluids that can compromise the integrity of the radiator. Passive louvers constructed using thick aluminum vanes are used currently to protect spacecraft radiators from some of the above effects, but they have several drawbacks: (i) their high aerial density makes it impractical to scale them to protect the much larger spacecraft radiators needed for future manned missions to the moon and beyond, (ii) the bimetallic actuators used to open and close the vanes in passive louvers rely on external temperature alone and so the louver cannot offer protection from dust and ionizing radiation when the ambient temperatures are high, and (iii) the bimetallic actuators need time scales of the order of hours to open and close. We have addressed the above limitations of passive louvers through the development of a low aerial density and rapidly actuating actively controlled louver. It is constructed from a custom alloy that offers much higher levels of protection against the ionizing radiation, dust and excessive heat loss at a fraction of weight compared to passive louvers while providing opening and closing time scales of the order of a second. Our modular design makes it easy to scale the system up or down depending on the application. We have recently constructed a 31 inch × 31 inch module of this louver and tested its functionality and effectiveness. These tests have shown that the louver can be opened and closed in less than 2 s. It reduces the transmission of ionizing radiation by 78% to 100% (depending on the radiation source), dust transmission by more than 93%, and heat loss by more than 97%. We are currently preparing to evaluate this device at the Johnson Space Center’s cryogenic vacuum chamber where it can be subjected to simulated lunar surface conditions. This paper provides a detailed discussion of the test designs as well as the data from tests that demonstrate the effectiveness in reducing the transmission of ionizing radiation, dust, and heat under laboratory conditions.

Radiator

Spacecraft Radiator Protection from Ionizing Radiation, Dust, and Excessive Heat Loss

Under a Phase II SBIR project funded by NASA Johnson Space Center (Contract No. 80NSSC25C0088), Analytical Scientific Products LLC (ASP) has been developing an actively controlled louver to protect spacecraft radiators from degradation due to exposure to various types of environmental conditions. Of particular interest are ionizing radiation during spacecraft transit through the Van Allen belts, dust during spacecraft landing and surface operations on the moon, and excessive heat loss during the long lunar night especially near the poles where the local ambient temperatures can drop below -200°C. Exposure to ionizing radiation and dust can degrade the optical properties of the radiator coating that in turn reduces its ability to reject excess heat from the spacecraft into the environment. Exposure to the extremely low temperature conditions during the lunar night near the poles can freeze the radiator fluids that can compromise the integrity of the radiator. Passive louvers constructed using thick aluminum vanes are used currently to protect spacecraft radiators from some of the above effects, but they have several drawbacks: (i) their high aerial density makes it impractical to scale them to protect the much larger spacecraft radiators needed for future manned missions to the moon and beyond, (ii) the bimetallic actuators used to open and close the vanes in passive louvers rely on external temperature alone and so the louver cannot offer protection from dust and ionizing radiation when the ambient temperatures are high, and (iii) the bimetallic actuators need time scales of the order of hours to open and close. We have addressed the above limitations of passive louvers through the development of a low aerial density and rapidly actuating actively controlled louver. It is constructed from a custom alloy that offers much higher levels of protection against the ionizing radiation, dust and excessive heat loss at a fraction of weight compared to passive louvers while providing opening and closing time scales of the order of a second. Our modular design makes it easy to scale the system up or down depending on the application. We have recently constructed a 31 inch × 31 inch module of this louver and tested its functionality and effectiveness. These tests have shown that the louver can be opened and closed in less than 2 s. It reduces the transmission of ionizing radiation by 78% to 100% (depending on the radiation source), dust transmission by more than 93%, and heat loss by more than 97%. We are currently preparing to evaluate this device at the Johnson Space Center’s cryogenic vacuum chamber where it can be subjected to simulated lunar surface conditions. This paper provides a detailed discussion of the test designs as well as the data from tests that demonstrate the effectiveness in reducing the transmission of ionizing radiation, dust, and heat under laboratory conditions.

Radiator

Singular Hall Response from a Correlated Ferromagnetic Flat Nodal‐Line Semimetal

Abstract Topological quantum phases are largely understood in weakly correlated systems, which have identified various quantum phenomena, such as the spin Hall effect, protected transport of helical fermions, and topological superconductivity. Robust ferromagnetic order in correlated topological materials particularly attracts attention, as it can provide a versatile platform for novel quantum devices. Here, a singular Hall response arising from a unique band structure of flat topological nodal lines in combination with electron correlation in a van der Waals ferromagnetic semimetal, Fe 3 GaTe 2 , with a high Curie temperature ofT c = 347 K is reported. High anomalous Hall conductivity violating the conventional scaling, resistivity upturn at low temperature, and a large Sommerfeld coefficient are observed in Fe 3 GaTe 2 , which implies heavy fermion features in this ferromagnetic topological material. The scanning tunneling microscopy, circular dichroism in angle‐resolved photoemission spectroscopy, and theoretical calculations support the original electronic features of the material. Thus, low‐dimensional Fe 3 GaTe 2 with electronic correlation, topology, and room‐temperature ferromagnetic order appears to be a promising candidate for robust quantum devices.

Chemistry

GOPEX Laser Transmission and Monitoring Systems

The laser transmission and monitoring system for the Galileo Optical Experiment (GOPEX) at the Table Mountain Facility (TMF) in Wrightwood, California is described. The transmission system configuration and the data measurement techniques are described. The calibration procedure and the data analysis algorithm are also discussed. The mean and standard deviation of the laser energy transmitted each day of GOPEX show that the laser transmission system performed well and within the limit established in conjunction with the Galileo Project for experiment concurrence.

G Okamoto