Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transition duct”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Outflow Boundary Conditions for Turbine-Integrated Rotating Detonation Combustors

This study examines outflow boundary conditions (BCs) in computational fluid dynamics (CFD) simulations of a transition duct with and without guide vanes that converts supersonic flow exiting a rotating detonation combustor (RDC) to subsonic flow to drive a turbine. Since the flow exiting the transition duct has swirling shock waves with significant spatial and temporal variations in pressure, temperature, and Mach number, imposing proper BCs poses a challenge. To ensure all swirling shock waves exit the transition duct without creating non-physical reflected waves at its outlet, this study examined three outflow BCs: (1) the average pressure imposed at the duct’s outlet, (2) a nonreflecting BC (NRBC) with a specified average pressure imposed at the duct’s outlet, (3) the average pressure imposed at the outlet of an extension duct made up of a buffer layer and a sponge layer. This study is based on the three-dimensional, unsteady density-weighted-ensemble-averaged continuity, Navier–Stokes, and energy equations for a thermally perfect gas closed by the realizable k–ε model and “enhanced” wall functions. The results obtained show that imposing an average pressure at the transition duct’s outlet produces spurious waves that degrade the physical meaningfulness of the solution. When the NRBC was applied, swirling shock waves exited the duct’s outlet without creating spurious waves. However, its usage requires the gas to be thermally, as well as calorically, perfect, which this study shows could be a concern. By imposing the average pressure at the outlet of an extension duct, the gas does not need to be calorically perfect. The results obtained show the effects of the sponge layer’s length and coarsening ratio on damping nonuniformities in non-physical reflected waves to ensure the flow exiting the transition duct’s outlet can do so as if there are no boundaries present and has the desired average pressure—even though the BC is applied at the extension duct’s outlet.

gas turbines↗

Defining a compact dry cooler design to reduce LCOE contribution in a CSP facility

Concentrating solar power (CSP), when coupled with a supercritical carbon dioxide (sCO 2 ) power cycle and sensible heat storage, presents a renewable and clean alternative for utility-scale power generation. However, in order to be competitive in the current and future markets, CSP facilities must limit their levelized cost of electricity (LCOE) by minimizing capital costs and reducing operating costs over the lifetime of the plant. Targeting this goal, this study investigates the LCOE impact of the power cycle pre-cooler. This study considers a compact dry cooler with micro-channel technology on the CO 2 side and formed fin geometry on the air side, using directly-coupled centrifugal fans and a transition duct to improve air distribution across the fins as well as protect the fins from contaminants which may cause blockage, soiling, fouling, and damage. In an effort to better understand the dry cooler impact on LCOE, a sensitivity study was conducted using various combinations of end-to-end approach temperatures, air-side pressure drop values, CO 2 -side pressure drop values, fan types, cooler turndown control schemes, cooler module sizes, and design-point ambient temperatures. Furthemore, off-design cycle performance data was calculated for each dry cooler design using NPSS simulation software; cycle performance data were then input to System Advisor Model (SAM) along with the associated capital costs for LCOE prediction of a 100 MW system over a 30 year plant lifetime. Results of this study show the LCOE is most sensitive to air-side performance, followed by heat transfer effectiveness and capital cost. It was found that a power cycle with a mid- to high-performance dry cooler will produce the most competitive power-production costs. Designing at the extreme ends for approach temperature (or effectiveness), design-point ambient temperature, and compactness (footprint) produce higher LCOE values; mid-range values for these parameters balance performance, operating costs, and associated capital cost to optimize LCOE.

14 SOLAR ENERGY↗

Design of a Compact Dry Cooler With an Aluminum Heat Exchanger Core for a Supercritical CO2 Power Cycle Is Evaluated for a Concentrating Solar Power Application

Abstract As the supercritical CO2 power cycle develops and the component technologies mature, there is still a need to reduce the associated capital and operating costs to maintain a competitive levelized cost of electricity (LCOE) in order to enter the market. When considering concentrating solar power (CSP) coupled with an sCO2 power block and sensible thermal storage, the technology presents a clean source for utility-scale power generation to support baseload or peak-load electrical demand. However, the LCOE of the technology is still considered higher than the competing technologies and should be reduced to better compete in the market; 2030 targets for dispatchable solar plants are 5¢/kWh for baseload CSP and 10¢/kWh for peaker plants, as set by the United States Department of Energy. In response to this need, this study is targeting improvements in the power cycle precooler to reduce power block contribution to LCOE. This study considers a dry cooler, as CSP plants are sensitive to water consumption because many installations are slated for remote or arid locations where solar irradiance is very high, but water is scarce. Furthermore, the power block footprint for an sCO2 system is quite compact, especially as compared to a steam cycle. Therefore, there is interest in installing a more compact dry cooler that is proportional to the reduced footprint sCO2 power block, while conventional dry coolers are an order of magnitude larger. The competing goals of size, performance, and cost were considered in this study to develop a compact dry cooler that can easily be packaged with the power block, significantly reducing the installation and transport cost compared to the current state of the art, while maintaining or improving upon the heat transfer performance and impact on plant LCOE. This paper details the high-level findings of a large dry cooler sensitivity study for design point selection, design of the compact dry cooler, expected year-round performance for the dry cooler and the power cycle, and the predicted LCOE for a 30-year plant life. It was found that an aluminum heat exchanger core can be suitably designed to meet the pressure and temperature requirements for a precooler in an sCO2 recompression Brayton cycle. The dry cooler assembly was found to have improved heat transfer performance, allowing for increased cycle efficiencies and a reduced plant LCOE. When coupled with a centrifugal blower and compact transition duct, the dry cooler assembly was able to reduce the installation footprint by over 50%.

14 SOLAR ENERGY↗

ECAR-5067 Computational Evaluation on Effect of Edge-rounding in Circular to Annular Flow Transitions within a Hexagonal Duct

In this ECAR, the computational fluid dynamics (CFD) simulation of the duct with a cross-section varying from circle to annulus was performed to evaluate the effect of edge-rounding of the internal edges. The edge of circular channel and the edge of inner annular channel were rounded with the radius of curvature ranged from 0 mm to 20 mm. The CFD results show that the pressure loss of the duct can be reduced by increasing the radius of the rounded edge. Case-A results showed that the pressure drop can be significantly reduced by the edge-rounding, e.g., the pressure drop was reduced approximately 56% by the radius of curvature of 5.0mm, and reduced 70% by the radius of curvature of 20.0 mm although its effectiveness would be attenuated as the radius of curvature of edge increases. Results from Case-B showed the impact of rounding the inlet edge was practically negligible compared to the outlet edge. This ECAR could provide a guideline to determine the optimum inlet module design of the VTR fuel rod bundle.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

RAFT: Reconfigurable Array of High-Efficiency Ducted Turbines for Hydrokinetic Energy Harvesting

Diversifying the energy harvesting portfolio is crucial to achieving the ambitious goal of transitioning to clean energy by 2030. Marine hydrokinetic energy has garnered renewed interest due to its high harvesting potential in the U.S., and the resource's reliability and predictability—remaining relatively constant on a daily basis and available 24/7. However, there are currently few commercial devices capable of harnessing the energy from flowing water. This project aims to bridge that gap by designing and evaluating a novel hydrokinetic turbine concept that can efficiently harvest energy from both rivers and tidal streams. The RAFT (Reconfigurable Array of High-Efficiency Ducted Turbines) concept introduces a duct surrounding the turbine rotor and creates an array of small 5-kW units. The duct serves two primary purposes: (1) it enhances hydrodynamic efficiency by accelerating flow to the rotor, and (2) it functions as a structural component, facilitating the formation of modular arrays that lower costs. This project focuses on demonstrating this concept and validating these benefits through simulations and scaled prototype testing. The project team includes 8 faculty members and over 20 students from 3 universities, organized into three core areas: hydrodynamics, electrical systems, and structural analysis, with additional teams dedicated to system integration, environmental assessment and risk management, and tech-to-market strategy. The team successfully demonstrated the increased hydrodynamic efficiency of a ducted turbine compared to an unducted version using high-fidelity simulations and prototype tests. Moreover, design optimization efforts led to surpassing the SHARKS program's goal of 60% reduction of the levelized cost of energy with a significant margin.

13 HYDRO ENERGY↗

Achieving Ducts in Conditioned Space

As codes push for greater energy savings, production homebuilders must consider ways to reduce the energy use associated with HVAC system performance. One prominent and effective approach to reduce energy use is the transition of ductwork from unconditioned space (attics, crawlspaces, basements) into conditioned space.

Building America↗

Development of Additively Manufactured Complex Tools for Autoclave Cure Composites

IACMI Project 4.9, Tooling for Composites with Washout Features Produced by Additive Manufacturing, assembled a team including the industry lead, Ability Composites, NREL and Colorado State University (CSU). Ability Composites had originally expressed interest in alternate methods of producing tooling for composite parts. In follow-up discussions, it became clear that one of the bigger tooling challenges revolved around small production volume composite parts that were tooled on washout material due to the complex geometry. To build an understanding of the potential, both from a technology and a cost perspective, for replacing conventional washout tooling with 3D printed thermoplastic tooling, a number of commercially available dissolvable FDM printing materials were evaluated, leading to tooling representative of commercial articles of interest to Ability Composites. Ultimately, Ability Composites was able to directly compare autoclave processed prepreg composite parts produced on conventional washout tooling to composite parts molded on 3D printed dissolvable tooling produced at CSU. Small, laboratory test specimens were developed to investigate the structural performance of the candidate materials under autoclave processing conditions, which were nominally 121 °C (250 °F) and 345 kPa (50 psi). In addition, several internal structural configurations (infills) were evaluated under autoclave conditions using model materials. The results of these tests indicated that two materials, Stratasys ST 130 and Infinite Materials Solutions Aquasys 180 (AQ 180), were the best candidates, given the specified autoclave processing conditions. ST-130 was slightly more robust than AQ-180; however, the AQ-180 was carried forward as it was dissolvable in water, not requiring the basic solution needed to dissolve ST-130. Based on the preliminary material and 3D printed structures evaluations, larger tools with a truncated square pyramid geometry were created to produce prepreg composite test articles for 3D printed dissolvable tool evaluation under standard autoclave fabrication conditions. Two tools were manufactured using ST-130 and one tool using traditional ceramic washout tooling media. The tools were evaluated for geometric fidelity and surface roughness changes before and after carbon fiber/epoxy prepreg composites were manufactured on the tooling. The autoclave processing did not impact the geometry significantly and was completed at 121 °C and 345 kPa, indicating satisfactory tool performance. The results from surface roughness testing of both the resulting composite and the associated tooling indicated that an adequate surface resulted without the need for a surface sealing step, as was required for the conventional washout tooling. Based on results of the truncated pyramid tests as a basis, ST-130, AQ-120 and AQ-180 materials were carried forward to the tool geometry of interest to Ability Composites. These hollow rectangular bent ducts, which were complex in nature and not extractable after cure, were used to understand the impacts of tool material and thickness. One ST-130 tool was produced as a partially solid part, with an enclosed 40% dense infill region to reduce weight and material use. This was the same approach evaluated in the truncated pyramid portion of the study. This tool was to be envelope vacuum bagged and directly compared to a monolithic tool of conventional washout material. The traditional monolithic ceramic tool was manufactured by Ability composites using CNC-based subtractive methods. An additional five dissolvable polymer tools, manufactured from ST-130, AQ-120, and AQ-180, using a hollow design were 3D printed and used to produce carbon fiber/epoxy composite evaluation articles. These hollow dissolvable tools were expected to be less influenced by the autoclave conditions as the wall was solid and vacuum bagging was inside and outside the tool. This alternative geometry was also evaluated as an option in techno-economic modeling. Print times were reduced from in excess of 3 days to under 30 hours, while surface quality and and tool integrity were substantially improved in the transition from the partially solid tool to the hollow tooling concept. Ability Composites produced autoclave-cured prepreg ducts on each of these tools. The autoclave conditions utilized were more severe than those of the initial trials, reaching temperatures of 160 °C and a pressure of 414 kPa. Under these conditions, the partially solid 3D printed tool with skin and 40% dense infill crushed significantly; however, the thicker ST-130 hollow tool showed good promise, deforming only slightly. The thinner hollow tool walls were unsuccessful as were the other materials. Overall, the hollow tool manufacturing process saved significant amounts of time and material in manufacturing as compared to the solid ducts and produced composite surface quality improvements compared to the traditional washout tooling. The TEM was developed to allow direct comparisons between conventional washout tool manufacturing processes and those developed at CSU. It also allowed for two separate 3D printed tool geometries to be analyzed and compared. In this case, the square bent duct tool geometry was determined to be representative of common washout tools. This geometry was compared with a scaled-up version of it to assess differences in the two manufacturing processes based on tool size. The model was developed to make use of user input in the form of geometry details, process steps, manufacturing parameters, bulk material costs, capital equipment costs, and general costs to calculate overall labor, material, capital equipment, and energy costs per manufactured tool for the conventional and additive manufacturing processes for the two representative geometries. It was also able to estimate step-by-step process times for the manufacturing process and geometries. Based on significant input from Ability Composites and CSU from their knowledge gained from hands-on manufacturing of the 3D printed bent duct tool geometry, costs and process times were calculated for the two manufacturing processes. Results showed that the additive manufacturing techniques developed at CSU can substantially reduce the costs of tool manufacturing by reducing labor times and material usage. This is because additive manufacturing is a relatively hands-off process and allows for the tool design to be optimized to reduce material usage. The disadvantage, however, is that process times for additive manufacturing are significantly longer. The three-dimensional (3D) printing process is slow if tight tolerances are required, but the analysis did show that print times could be reduced with the hollow tool geometry. Also, further advances in additive manufacturing could expedite the process. Costs and process times for the tool washout process were calculated separately. They showed that costs are relatively insignificant when compared to the overall tool manufacturing processes, but with increases in tool size, costs for the conventional manufacturing approach are larger than for additive manufacturing. Again, the washout process for conventional tools is very hands-on, whereas for additively manufactured tools the print medium is dissolved in an automated detergent bath at the sacrifice of process time. The analysis showed that optimizing the additively manufactured tools may also reduce washout times. Overall, Project 4.9 demonstrated that commercially available dissolvable 3D printing materials exist that can be used to produce dissolvable tooling capable of surviving prepreg composites fabrication under autoclave conditions of 121 °C (250 °F) and 345 kPa (50 psi). An alternative hollow dissolvable tool design was developed which was structurally superior to the initial concept and was cost and time effective versus conventional washout tooling. The 3D printed sacrificial tool required no added surface sealing steps prior to composite part layup and cure, offering a significant advantage over the porous conventional washout tooling.

36 MATERIALS SCIENCE↗

Flow friction in a wide rectangular duct with a beveled inlet: Informal Notes of Fundamental Fluid Physics Studies

Fundamental streamwise pressure distributions were measured at Idaho State University to address a primary objective of obtaining insight into the apparent evolution of air flow regimes at moderate Reynolds numbers in thin, wide rectangular ducts with converging inlets. Ducts of 3.030 and 4.077 mm spacings s (called three and four mm), having non-dimensional lengths of (L/s) ≈ 500.8 and 372.2 and widths (W/s) ≈ 114.6 and 83.2, respectively, were compared. Flow rates ranged from Reynolds numbers based on hydraulic diameter (Re Dh ) of about 980 to 10,000 and corresponding non-dimensional downstream pressure gradient parameters (-K p ) covered the range 0.038 to 0.0061, respectively.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Energy Saving Estimation of ASHRAE Guideline 36 Supervisory Setpoint Reset Controls in a Commercial Large Office Building

Designing, commissioning, and retrofitting HVAC control systems for energy efficiency is crucial, but the use of ad-hoc control sequences by designers and contractors, based on scattered information, results in diverse and sub-optimal sequences. ASHRAE Guideline 36 (G36) addresses the challenge by providing standardized, rule-based HVAC control sequences that prioritize energy efficiency. However, there is limited evaluation of their energy performance at the building level, with only a few studies primarily focused on HVAC airside systems in small-to-medium-sized commercial buildings. In this study, the energy performance of ASHRAE Guideline 36 control sequences was assessed using a large office building emulator in Chicago. The emulator features a central plant system with multiple chillers and boilers as well as multiple variable air volume (VAV) systems with terminal reheat. To achieve a high-fidelity representation, we developed a Spawn-of-EnergyPlus-based model for the large office building, maintaining the DOE prototype large office building setup but substituting the HVAC system with its Modelica counterpart. This substitution ensures that the building thermal load, HVAC system's dynamics, and detailed control sequences are all accurately represented. The study involved evaluating and implementing control strategies outlined in ASHRAE Guideline 36-2021 to replace conventional controls. These strategies include the demand-based supply air temperature and duct static pressure setpoint reset and the request logic for demand-based reset of chilled/hot water supply temperature setpoints and pipe static pressure setpoints. Energy performance was evaluated under various load conditions, including cooling, heating, and transitional seasons, both for individual control strategies and in combination. The results indicate that the collective control strategies retrofit yield greater energy savings than the sum of individual strategies, highlighting the synergistic benefits of incorporating both airside and plant-side control retrofits. Additionally, energy savings of up to 41% in the heating season, 18% in the shoulder season, and 20 % in the cooling season were observed compared to baseline control while maintaining the thermal comfort level.

ASHRAE Guideline 36, Commercial buildings, Control↗

Observation of High-Energy Electrons Precipitated by NWC Transmitter From PROBA-V Low-Earth Orbit Satellite

The very low-frequency transmitter in the Northwest Cape of Australia (NWC) has previously been observed to pitch-angle scatter electrons with energies from 30–400 keV, creating enhanced fluxes measured by low-Earth orbiting (LEO) satellites. Here we use observations from the Energetic Particle Telescope on PROBA-V. We compare the measured flux, as a function of local magnetic field strength, when the NWC transmitter is “on” versus “off,” and find enhanced fluxes only when NWC is “on” and located on the nightside. The enhanced fluxes occur in the population gradually transitioning from “permanently trapped” to “quasi-trapped.” We show that electrons up to 800 keV, substantially higher energy than previously studied, are scattered by resonant interactions with NWC to produce enhanced fluxes. The enhanced fluxes appear at multiple L-shells for each energy channel, consistent with resonance conditions at distinct wave normal angles, that indicate ducted interactions at L < 1.55 and unducted interactions at L > 1.65.

79 ASTRONOMY AND ASTROPHYSICS↗

Advanced HVAC Humidity Control for Hot-Humid Climates

During this project we develop and validate a cost-effective, integrated control solution to improve humidity control and comfort for energy-efficient homes in hot-humid climates. This study focuses on developing a strategy that is effective, field tested, and practical for builders to install with minimal disruption to standard practices. A successful solution would simplify the transition to high-performance humidity control and be the basis for design and installation guidance. By relying on the central system as a starting point, the strategy employed minimizes system complexity and cost for builders, while improving comfort and operating cost for homeowners. The solution strategy was to coordinate the cooling, dehumidification, and ventilation functions of central, ducted HVAC systems to better control indoor humidity, improve occupant thermal comfort, and capture energy savings. The primary strategic goals were to: (1) optimize dehumidification by the central air-conditioning system, particularly during part-load conditions, using conventional equipment with modified control settings and lower system airflows; (2) maximize ventilation during heating/cooling on-cycles, to “bank” and condition outdoor ventilation air, and minimize ventilation during off-cycles; (3) quantify the effectiveness and energy impact of the dehumidification and ventilation strategies, while identifying a metric that would be useful to evaluate latent effectiveness. For the test houses in our study, located in Richmond Hill, Georgia; Houston, Texas; and Monroe, Louisiana we observed: (1) the indoor humidity did not exceed 60% RH during the monitored cooling season for 99% of the time in Richmond Hill, 96% of the time in Houston, and 90% of the time in Monroe; (2) the dehumidification strategy improved the steady-state latent capacity of the HVAC system at design conditions by 16% to 49% at the Houston test house and by 28% to 71% at the Monroe test house, depending on which mode the system was operating in; and (3) the good results at the test houses were primarily due to the amount of time the air-conditioning system operated in ramping or dehumidification modes, or both, particularly during the early cooling season. This study demonstrates that air conditioners or heat pumps with a single-stage compressor can provide good humidity control without the need for a two-stage or variable-stage compressor system. The airflow and control settings for ramping and dehumidification modes are critical to control indoor humidity in hot-humid climates, particularly during part-load and shoulder season conditions. The dehumidification strategy used in this study did not jeopardize the mechanical reliability of the cooling equipment. The strategies used in this study are applicable across various equipment brands, models, and efficiency levels, and also applicable to a broad range of homes in hot-humid climates. Results will vary by specific equipment, location, and house configuration and construction.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Prediction of Detonation-Induced Disturbances Propagating Upstream into Inlets of Rotating Detonation Combustors

Disturbances caused by the detonation wave in a rotating detonation combustor (RDC) propagate upstream through the inlet, and can potentially affect and couple to upstream components, such as turbomachinery or isolators. These disturbances can potentially also affect the operation of the RDC itself. By drawing from the analogy of a detonation wave bounded by an inert gas, the pressure disturbances observed upstream of the inlet are explained as the consequence of the passage of an upstream propagating oblique shock. In this study, the pressure rise in the plenum from the oblique shock is measured in an axial air inlet RDC. The speed of the upstream propagating wave is estimated to be moderately above the acoustic speed of the oxidizer in the plenum. The wave propagates into the plenum despite local regions of choking in the inlet. It is estimated that the time it takes a fluid particle to transit from the plenum to the detonation channel through the inlet is much larger than the rotational time of the detonation wave. This implies that a fluid particle experiences multiple shocks prior to entering the detonation channel. The oblique shock propagating upstream through the inlet area change is modeled by leveraging an analogy with a quasi-1D shock wave moving in a variable area duct with mean (incoming) flow. Due to flow expansion along the area change, fluid particles are found to experience stronger shocks in the inlet than in the plenum, thereby creating different thermodynamic states within the fill region as the oxidizer emerges from the inlet.

Feleo, Alexander↗

Validation of a Co-Optimized, Smart Hybrid Heat Pump Control

This study examines a residential dual fuel (DF) heating system that integrates heat pump and gas furnace technology with a home’s forced-air distribution ducts. Specifically, it explores a retrofit where an “add-on” heat pump replaces the air conditioning (A/C) system and is combined with the home’s existing furnace and air handler. The research team developed and validated an innovative control scheme for this integrated DF system that selected the more economical heating source (furnace or heat pump) while maintaining comfort in the home. The project’s field study and subsequent modeling analysis show that this control scheme can decrease energy use, cost, and emissions compared to a furnace-only system. As homes in mixed and cold climates transition to more electric space heating, furnace-to-dual fuel system retrofits offer a solution that can alleviate the retrofit costs, energy cost concerns, and peak load impacts of full electrification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ablating Lgr5-expressing prostatic stromal cells activates the ERK-mediated mechanosensory signaling and disrupts prostate tissue homeostasis

The heterogeneity of the prostate stromal cells is widely appreciated but the functional implication remains incompletely understood. Using genetic lineage tracing and light-sheet imaging, we show that some fibroblast cells near the junction of the mouse proximal prostatic ducts and prostatic urethra highly express Lgr5. Genetic ablation of these anatomically restricted stromal cells, but not nonselective ablation of prostatic stromal cells, rapidly induces prostate epithelial turnover and dedifferentiation that are reversed following spontaneous restoration of the Lgr5 + stromal cells. RNA-Seq analysis implies that ablating the Lgr5 + stromal cells activates a mechanosensory response. We show that ablating the Lgr5 + stromal cells impairs the control of prostatic ductal outlet, increases prostate tissue stiffness, and activates the mitogen-activated protein kinase (MAPK). Suppressing MAPK overrides the increased epithelial proliferation. This study demonstrates that the Lgr5 + stromal cells regulate tissue homeostasis in a long-distance manner by maintaining anatomic integrity and implies that the cells near the transitional regions between organs likely control organ homeostasis by sustaining a balanced mechanoforce.

59 BASIC BIOLOGICAL SCIENCES↗

Experimental investigation of turbulent wake flows in a helically wrapped rod bundle in presence of localized blockages

In nuclear sodium fast reactors, bundles of rods are tightly packed into a triangular lattice, enclosed in a hexagonal duct, and each pin is spirally wrapped with a thin wire. Flow blockages can potentially impact the local flow characteristics and heat transfer mechanisms in the bundle due to its small subchannel size. The effects of the blockage on the flow structures and heat transfer mechanisms are important aspects that require an accurate investigation. In this study, the flow-field characteristics in the vicinity of a blockage located in the exterior subchannel of rod bundles with helically wrapped wires were experimentally investigated. The velocity fields in the exterior subchannel were acquired by applying matched-index-of-refraction and time-resolved particle image velocimetry (TR-PIV) techniques for Reynolds numbers of Re 1 = 4000 and Re 2 = 17 000, i.e., equivalent to Rew 1 = 19 600 and Rew 2 = 83 200, respectively, based on the blockage width. The results from the TR-PIV measurements revealed an arch-shaped vortex with a large flow recirculation and a pair of counter-rotating vortices in the wake region downstream of the blockage, which is commonly observed in the wake flow of bluff bodies. The relative lateral distance and angle between the two vortices decreased when the Reynolds numbers increased. Profiles of maximum turbulence intensity along the shear layers illustrated the transition process including the growth, peak, and decay along the flow direction. From the spectral analysis of the turbulent velocities extracted at points along the shear layer, the Strouhal numbers ( St ) representing the vortex shedding frequency were found to be St = 0.25 and St = 0.56 for the left and right shear layers, respectively. Characteristics of shear layers generated by the blockage in the exterior subchannel were investigated via the two-point cross correlation of fluctuating velocities. The patiotemporal cross correlations of turbulent velocities, computed at points in the region where the left shear layer exhibited rolling effects and vortex breakdowns, were considerably wider and longer. The convection velocity U c was estimated to be ~0.82 U m to 0.93 U m . Proper orthogonal decomposition (POD) analysis was applied to the instantaneous velocity fields to extract the statistically dominant flow structures. It was found that POD modes 2–3 and 4–5 formed the pair modes when the corresponding POD temporal coefficients depicted sinusoidal shapes and exhibited nearly circular orbits in the phase space. Spectral analysis of the POD temporal coefficients confirmed the vortex shedding frequencies detected in the analysis of turbulent velocities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MOOSE Reactor Module Meshing Enhancements to Support Reactor Physics Analysis

The U.S. Department of Energy Office of Nuclear Energy Advanced Modeling and Simulation (NEAMS) program develops an integrated suite of advanced reactor physics tools built upon the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. Each code generally requires an input finite element mesh on which the physics solution is calculated, reported, and transferred to other physics codes. The meshing process is often burdensome for the complex geometries present in reactors due to lack of easy-to-use, open-source meshing tools. To address the bottleneck associated with meshing complex geometries found in nuclear reactors, NEAMS initiated the development of the MOOSE Reactor Module starting in FY21. The Reactor Module builds off the existing MOOSE Mesh System to include targeted meshing capabilities such as the ability to generate hexagonal pin cells, assemblies with ducts, rotating control drums, cores, peripheral zones around a core, as well as the automatic labeling (“reporting IDs”) of pin, assembly, and planar zones to simplify post-processing of results. As a Physics Module in MOOSE, the Reactor Module is open-source, available with any MOOSE installation, directly compatible with MOOSE-based tools, and can be invoked from MOOSEbased applications to generate meshes. Functionality from the Reactor Module has been applied to several advanced reactor concepts to demonstrate user workflow improvements and accuracy. The primary objective of the Reactor Module is to improve useability of MOOSEbased tools by streamlining mesh generation and output inspection processes. During FY22, the functionality of the Reactor Module (and accompanying Mesh System) has been expanded based on user needs. First, the Reactor Geometry Mesh Builder capability developed primarily in FY21 has been refactored and merged to the public MOOSE repository. This capability wraps underlying Reactor Module mesh generators into a “Pin – Assembly – Core” workflow appropriate for conventional Cartesian and hexagonal geometries, and notably assigns material IDs during mesh generation stage and generates only the minimal number of blocks needed in order to reduce computational burden. Biasing and boundary layer options have been added to the base mesh generators as required by thermal hydraulics solvers. The reporting ID functionality has been expanded to differentiate ring-wise and azimuthal sectors within a pin for use with depletion algorithms, and VectorPostProcessor and Reporter objects are now available to integrate solution variables across zones based on ID combinations. Functionality to trim hexagonal meshes along the center or periphery has been developed so users may leverage symmetry and reflective boundary conditions to reduce the mesh size. A flexible and powerful tool to fill the space between two sidesets has been introduced to the framework and can be used for transition layers such as stitching two assemblies together with different numbers of pins, or for complex geometries which do not follow conventional Cartesian/hexagonal patterns. Finally, additional verification problems were performed with NEAMS physics tools in complement with existing NEAMS work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modifications to Solar Titan-130 Combustion Systems for Efficient, High Turndown Operation

The project team of Southwest Research Institute® (SwRI®), Solar Turbines Incorporated (Solar), the Electric Power Research Institute (EPRI), the University of California, Irvine (UCI), and the Georgia Institute of Technology (Georgia Tech) investigated methods to allow higher efficiency part-load operation of a Solar Titan 130 gas turbine. The objective was to develop a low-emission combustion system capable of sustaining combustion and avoiding lean blowout during high turndown operation, which would allow the gas turbine to operate as efficiently as possible at part load. Currently, electric utility markets are beginning to experience substantial increases in renewable energy generation. Some of these renewable energy sources have highly variable output in an uncontrolled manner. In order to maintain grid stability, there is a need for power plants to ramp up power to the grid rapidly to make up for drops in renewable generation. This is often termed spinning reserve, but the size of this reserve may need to increase as renewable penetration into the electric utility market increases. Small combined heat and power (CHP) power plants provide a promising option for meeting this spinning reserve requirement. In order to operate in spinning reserve while still meeting the heat requirements for the CHP, the gas turbine needs to operate efficiently at very low loads. Efficient, high turndown operations in this engine are limited by the lean flammability limit of the premixed combustion system. This project sought enhance the lean operability range of the Titan 130 combustor. First, the project team participated in a brainstorming activity and ultimately selected two concepts to explore: fuel augmentation with hydrogen (H2) to improve the stability at lean operating conditions and modifications to the fuel nozzle to improve the emissions performance at lean operating conditions. Analytical and laboratory investigations were accomplished by UCI to investigate the efficacy of H2 addition at improving lean blow out (LBO) limits and the resulting emissions. These investigations used a variety of chemical reactor network (CRN) and CFD models, validated against laboratory data, to model the impact of H 2 and inform the experimental efforts accomplished by SwRI and Solar. Ultimately, both the CRN and CFD models yielded generally good agreement with the experimental data below a particular temperature threshold. Atmospheric tests of a full-scale T130 annular combustor were performed at SwRI facilities in San Antonio, Texas, to investigate the use of H 2 addition. For these tests, the T130 combustion system remained largely unchanged; minor modifications were performed to the fuel ducting to allow for the safe use of H 2 . The test ultimately demonstrated that the addition of H 2 to the fuel mixture significantly increased the AFR ratio at which the combustor could operate. This improvement to the LBO limit should allow for less use of compressor bleed and less throttling needed by the inlet guide vanes (IGV). This in turn could result in more efficient operation of the gas turbine at lower load points. The second modification explored in this work was a direct modification to the T130 injector. The project team hypothesized that modifications to the pilot of the T130 injector could provide lower emissions at high turn-down operations. These modifications were manufactured and explored by the team at Solar. High pressure rig tests, originally slated to occur at SwRI, were ultimately accomplished by Solar to maintain overall project budget and mitigate cost growth attributable to supply chain issues and inflation. The pressurized rig tests ultimately showed that the SwRI Project No. 18.24153 - DE-EE0008415 Page 2 Final Technical Report January 24, 2024 modifications did not significantly alter the performance of the combustion system at the high turn-down conditions; both the modified injectors and the baseline configuration exhibited elevated emissions comparted to the full-load operating condition. A final set of studies performed by EPRI investigated the benefit-cost of flexible CHP as well as a grid interconnection study for the California Independent System Operator (CAISO) grid. These studies considered: traditional CHP with no spinning reserve available for on-demand grid support, 50% flexible CHP where 50% of the machine’s capacity is consumed by on-site baseload operations while providing an additional 50% capacity for on-demand grid support, and 70% flexible CHP where 70% of capacity is consumed on-site by baseload operations and 30% is available for on-demand grid support. In all cases, the analyses showed a benefit-to-cost ratio greater than unity implying a positive net present value for all configurations. However, the traditional CHP showed the most economic benefit. These results are sensitive to several factors, many of which are not fully known and may vary over time. Thus site owners must be convinced that taking up the increased costs and risks from flexible CHP would be worth implementing. As the grid in California and across the country transition to incorporate larger renewable energy generation, flexible CHP can provide much needed operating reserves and dispatchability. Alternative fuel options, such as hydrogen blending and biofuels, may also lower carbon intensities of CHP. Flexible CHP should be examined in the evolving market to understand innovative business models, changes market rules and services, and new technologies.

20 FOSSIL-FUELED POWER PLANTS↗

Low fractional volume superconductivity in single crystals of Pr{sub 4}Ni{sub 3}O{sub 10} under pressure

Magnetotransport measurements of P⁢r4⁢N⁢i3⁢O10 single crystals performed under externally applied pressures up to 73 GPa in diamond anvil cells with either KBr or Nujol oil as pressure media yield signatures of superconductivity with a maximum onset temperature of approximately 31 K. True zero resistance was not observed, consistent with a nonpercolating superconducting volume fraction. Magnetization measurements provided corroborating evidence of superconductivity, with a pressure-dependent diamagnetic signal occurring below the onset temperature, and an estimate from the absolute value of the susceptibility suggests a superconducting volume fraction on the order of 10%. We observe sample to sample variations in the magnitude and pressure dependence of 𝑇𝑐 as well as a dependence on the configuration of electrical contacts on a given sample. Possible causes of this behavior may be significant inhomogeneities in the pressure and/or damage to the samples induced by the pressure media as well as inhomogeneities in the crystals themselves. The results imply that our as-grown P⁢r4⁢N⁢i3⁢O10 single crystals are not bulk superconductors but that there is a minority structure present within the crystals that is indeed superconductin

Chen, Xinglong↗