Optimal subinterval selection approach for power system transient stability simulation

Power system transient stability analysis requires an appropriate integration time step to avoid numerical instability as well as to reduce computational demands. For fast system dynamics, which vary more rapidly than what the time step covers, a fraction of the time step, called a subinterval, is used. However, the optimal value of this subinterval is not easily determined because the analysis of the system dynamics might be required. This selection is usually made from engineering experiences, and perhaps trial and error. This paper proposes an optimal subinterval selection approach for power system transient stability analysis, which is based on modal analysis using a single machine infinite bus (SMIB) system. Fast system dynamics are identified with the modal analysis and the SMIB system is used focusing on fast local modes. An appropriate subinterval time step from the proposed approach can reduce computational burden and achieve accurate simulation responses as well. As a result, the performance of the proposed method is demonstrated with the GSO 37-bus system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Condition‐based exciter model complexity reduction for improved transient stability simulation

A reduced model approach to decrease computational complexity in power system transient stability simulation is presented. This study investigates conditions that make fast modes active or inactive using practical power system examples. Modes in the original system where fast dynamics do not appear can be neglected, allowing simulation steps to be increased without numerical stability issues. During a transient simulation, the proposed method switches dynamically between the original exciter model and the reduced one, depending on the switching criterion presented. A high level of accuracy is achieved and computational efficiency is increased. Case studies with the Western Electricity Coordinating Council system are provided to validate the performance of the proposed method.

Kim, Soobae↗

Modeling of Grid-Forming Inverters for Transient Stability Simulations of an all Inverter-based Distribution System

Existing models of grid-forming inverters are typically three-phase electromagnetic models and positive sequence electromechanical models. Both of them are not suitable for dynamic simulations of large scale three-phase unbalanced distribution systems. In order to investigate grid-forming inverters’ impact on the transient stability of large scale three-phase unbalanced distribution systems, a dynamic model of a grid-forming inverter is developed and implemented in an open-source GridLAB-D simulation environment. The advantage of this method is that it can be extended to full-size three-phase unbalanced distribution systems. Simulation results of an all grid-forming inverter-based modified version of IEEE 123-node distribution system verify the capability of grid-forming inverters to maintain the transient stability of a resilient distribution system.

Grid-forming, Inverter, Distribution System, Trans↗

Positive-Sequence Modeling of Droop-Controlled Grid-Forming Inverters for Transient Stability Simulation of Transmission Systems

Here, this paper describes a positive-sequence model to represent two widely reported droop-controlled grid-forming inverters for bulk power systems simulation study. Methods of how to develop the equivalent voltage source behind impedance to represent inverters with and without inner control loops, modeling of P-f and Q-V droop controls, active and reactive power limiting modeling, and modeling of fault current limiting controls are described in detail. The model is implemented in commercially available positive-sequence simulation tools and compared with detailed electromagnetic transient models in both a single-grid-forming-inverter infinite-bus system and a modified IEEE 39-bus system. Finally, the model is tested on the full US Western Electricity Coordinating Council (WECC) system. Study results show that the model has a good level of accuracy compared to the detailed EMT models, and at the same time also achieves a high computational efficiency, which is suitable for the bulk power system simulation study.

42 ENGINEERING↗

Adaptive Model Reduction for Parareal in Time Method for Transient Stability Simulations

Real time or faster than real time simulation can enable system operators to foresee the effect of crucial contingencies on the power system dynamics and take timely actions to prevent system instability. Parareal in time method uses concurrent computations on different segments of the time domain of interest to speed up the dynamic simulations. This paper describes the application of an adaptive nonlinear model reduction method in improving computational speed of the Parareal solver. The proposed method adaptively switches between a hybrid system with selective linearization and a completely linear system based on the size of a disturbance. The functions in the hybrid system are linearized based on the electrical distance between specific generators and the area where disturbances originated. The proposed method is tested on the 327-machine 2383-bus Polish system.

Osipov, Denis↗

Advancing the Adoption of High Performance Computing for Time Domain Simulation

Time domain transient stability simulation of large interconnected power systems is becoming increasingly computationally intensive. With the addition of high levels of variable generation that can aggregately ramp over many hours, both the complexity and time horizon for which power system simulations will need to be conducted are increasing. Additionally, extended-term time domain simulation is required to analyze power system security when cascading events across the system span minutes or even hours. Analysis of these occurrences requires modeling power system dynamics over tens of minutes to many hours rather than tens of seconds. Because of the required high computational intensity, there are presently no stability modeling/simulation platforms that combine the needed computational capabilities with the required power system models relevant for representing and analyzing the potential reliability implications of phenomena that occurs over both short- and extended-term dynamic timeframes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Impacts of Control, Penetration, and Distribution of Embedded Storage Network in Bulk Power System

The current shift in generation mix from fossil fuel plants towards variable and intermittent renewable energy sources is poised to create a future grid with reduced physical inertia and mismatch between generation and demand. Embedded storage, which is a concept of a coordinated network of storage units sited at the interface between the transmission and distribution system, is proposed as a mechanism to provide a buffer between generation and demand. This paper proposes an automated framework to model and integrate embedded storage in large-scale power systems with industry-grade grid-following (GFL) and grid-forming (GFM) control technologies. More importantly, the developed framework is used to explore the impacts of embedded storage control, penetration, location, and capacity in providing fast frequency response to the grid under contingency events such as generator trips and faults. The framework and study are conducted using the transient-stability simulation tool PSS/E and a realistic model of the Puerto Rico grid as a chosen test system. The simulation results show that GFL and GFM embedded storage, distributed throughout the system, with sufficient penetration and capacity, can effectively improve primary frequency response of the system under the studied contingency events.

Battery Energy Storage, embedded storage, grid-for↗

A Novel Interfacing Technique for Distributed Hybrid Simulations Combining EMT and Transient Stability Models

With steady increase of power electronic devices and nonlinear dynamic loads in large scale AC/DC systems, the traditional hybrid simulation method, which incorporates these components into a single EMT subsystem and hence causes great difficulty for network partitioning and significant deterioration in simulation efficiency. To resolve these issues, a novel distributed hybrid simulation method is proposed in this paper. The key to realize this method is a distinct interfacing technique, which includes: i) a new approach based on the two-level Schur complement to update the interfaces by taking full consideration of the couplings between different EMT subsystems; and ii) a combined interaction protocol to further improve the efficiency while guaranteeing the simulation accuracy. The advantages of the proposed method in terms of both efficiency and accuracy have been verified by using it for the simulation study of an AC/DC hybrid system including a two-terminal VSC-HVDC and nonlinear dynamic loads.

Distributed hybrid simulation↗

Transient Stability of the Grid with a Wind Power Plant

This paper reports on an investigation of the impact of wind power plant penetration on the transient stability of the grid. Transient stability for different faults is investigated via simulation. A wind power plant with 22 turbines operated in variable speed mode will be used as the subject of the study. As a comparison, we replace the wind power plant with a conventional wind power plant (synchronous generator) and compare the results for the same faults. We also consider the effect of different locations.

17 WIND ENERGY↗

Efficient Simulation of Cascading Outages Using an Energy Function-Embedded Quasi-Steady-State Model

Here, this paper proposed an energy function-embedded quasi-steady-state model for efficient simulation of cascading outages on a power grid while addressing transient stability concerns. Compared to quasi-steady-state models, the proposed model incorporates short-term dynamic simulation and an energy function method to efficiently evaluate the transient stability of a power grid together with outage propagation without transient stability simulation. Cascading outage simulation using the proposed model conducts three steps for each disturbance such as a line outage. First, it performs time-domain simulation for a short term to obtain a post-disturbance trajectory. Second, along the trajectory, the system state with the local maximum potential energy is found and used as the initial point to search for a relevant unstable equilibrium by Newton's method. Third, the transient energy margin is estimated based on this unstable equilibrium to predict an out-of-step condition with generators. The proposed energy function-embedded quasi-steady-state model is tested in terms of its accuracy and time performance on an NPCC 140-bus power system and compared to a quasi-steady-state model embedding transient stability simulation.

Guo, Zhenping [Univ. of Tennessee, Knoxville, TN (↗

State of the art in electromagnetic modeling for the Compact Linear Collider

SLAC's Advanced Computations Department (ACD) has developed the parallel 3D electromagnetic time-domain code T3P for simulations of wakefields and transients in complex accelerator structures. T3P is based on state-of-the-art Finite Element methods on unstructured grids and features unconditional stability, quadratic surface approximation and up to 6th-order vector basis functions for unprecedented simulation accuracy. Optimized for large-scale parallel processing on leadership supercomputing facilities, T3P allows simulations of realistic 3D structures with fast turn-around times, aiding the design of the next generation of accelerator facilities. Applications include simulations of the proposed two-beam accelerator structures for the Compact Linear Collider (CLIC) - wakefield damping in the Power Extraction and Transfer Structure (PETS) and power transfer to the main beam accelerating structures are investigated.

43 PARTICLE ACCELERATORS↗

Jacobian Free-Newton Krylov Discontinuous Galerkin Method and Physics-Based Preconditioning for Nuclear Reactor Simulations

Multidimensional, higher-order (2nd and higher) numerical methods have come to the forefront in recent years due to significant advances of computer technology and numerical algorithms, and have shown great potential as viable design tools for realistic applications. To achieve this goal, implicit high-order accurate coupling of the multiphysics simulations is a critical component. One of the issues that arise from multiphysics simulation is the necessity to resolve multiple time scales. For example, the dynamical time scales of neutron kinetics, fluid dynamics and heat conduction significantly differ (typically >1010 magnitude), with the dominant (fastest) physical mode also changing during the course of transient [Pope and Mousseau, 2007]. This leads to the severe time step restriction for stability in traditional multiphysics (i.e. operator split, semi-implicit discretization) simulations. The lower order methods suffer from an undesirable numerical dissipation. Thus implicit, higher order accurate scheme is necessary to perform seamlessly-coupled multiphysics simulations that can be used to analyze the “what-if” regulatory accident scenarios, or to design and optimize engineering systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparative Implementation of High Performance Computing for Power System Dynamic Simulations

Dynamic simulation for transient stability assessment is one of the most important, but intensive, computations for power system planning and operation. Present commercial software is mainly designed for sequential computation to run a single simulation, which is very time consuming with a single processer. The application of High Performance Computing (HPC) to dynamic simulations is very promising in accelerating the computing process by parallelizing its kernel algorithms while maintaining the same level of computation accuracy. This paper describes the comparative implementation of four parallel dynamic simulation schemes in two state-of-the-art HPC environments: Message Passing Interface (MPI) and Open Multi-Processing (OpenMP). These implementations serve to match the application with dedicated multi-processor computing hardware and maximize the utilization and benefits of HPC during the development process.

97 MATHEMATICS AND COMPUTING↗

Magnetron-driven microton-injector of a terahertz free electron laser

A magnetron-driven microtron injector has been developed for a terahertz free electron laser (FEL). An internal injection system was chosen for the microtron to achieve a compact and inexpensive design. The system provides acceleration of electrons with low emittance and energy spread that is highly important for the FEL. However, the intrapulse instabilities of the accelerated current and the bunch repetition rate inherent to the injection system make problems for the FEL operation. Simulations of the beam dynamics and the transient process allow one to compute the load characteristic of the accelerating cavity and the time-dependent accelerated current. The simulation techniques also allow one to calculate time-dependent deviations of the magnetron frequency in the coupled system of the accelerating and magnetron cavities, as well as deviations in the bunch repetition rate. The computations validate proposed concepts for increasing the intrapulse current stability with appropriate time-dependent variation of the magnetron power and decreasing the bunch repetition rate instability through a simple microwave scheme utilizing the microtron accelerating cavity concurrently as an external stabilizing resonator for the magnetron. The realized concepts and optimization of the microtron regimes using the simulated phase motion of the accelerated bunch provide stable operation of the terahertz FEL, tunable in the range of 1-3 THz with extracted macropulse power up to 50 Watts at the macropulse energy of -0.2 mJ.

43 PARTICLE ACCELERATORS↗

Power grid reliability and security

This project has led to the development of a real-time simulation platform for electric power grids called Grid Simulator or GridSim for simulating the dynamic and information network interactions of large- scale power systems. The platform consists of physical models of power system components including synchronous generators, loads and control, which are simulated using a modified commercial power simulator namely Transient Stability Analysis Tool (TSAT) [1] together with data cleanup components, as well as an emulated substation level and wide-area power analysis components. The platform also includes realistic representations of communication network middleware that can emulate the real-time information flow back and forth between substations and control centers in wide-area power systems. The platform has been validated on a realistic 6000-bus model of the western American power system. The simulator GridSim developed in this project is the first of its kind in its ability to simulate real-time response of large-scale power grids, and serves as a cost effective real-time stability and control simulation platform for power industry.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Differential tapasin dependence of MHC class I molecules correlates with conformational changes upon peptide dissociation: A molecular dynamics simulation study

Efficiency of peptide loading to MHC class I molecules in the endoplasmatic reticulum depends on the class I allele and can involve interaction with tapasin and other proteins of the loading complex. Allele HLA-B*4402 (Asp at position 116) depends on tapasin for efficient peptide loading whereas HLA-B*4405 (identical to B*4402 except for Tyr116) can efficiently load peptides in the absence of tapasin. Both alleles adopt very similar structures in the presence of the same peptide. Molecular dynamics (MD) simulations on induced peptide termini dissociation from the α1/α2 peptide binding domains have been performed to characterize free energy changes and associated structural changes in the two alleles. A smooth free energy change along the distance dissociation coordinate was obtained for N terminus dissociation. A different shape and magnitude of the calculated free energy change and was obtained for induced peptide C terminus dissociation in case of the tapasin independent allele B*4405 compared to B*4402. Structural changes during C terminus dissociation occurred mainly in the first segment of the α2-1 helix that flanks the peptide C-terminus binding region (F-pocket) and contacts residue 116. This segment is also close to the proposed tapasin contact region. For B*4402, a stable shift towards an altered open F-pocket structure deviating significantly from the bound form was observed. In contrast, B*4405 showed only a transient opening of the F-pocket followed by relaxation towards a structure close to the bound form upon C terminus dissociation. The greater tendency for peptide-receptive conformation in the absence of peptide combined with a more long-range character of the interactions with the peptide C terminus facilitates peptide binding to B*4405 and could be responsible for the tapasin independence of this allele. A possible role of tapasin in case of HLA-B*4402 and other tapasin-dependent alleles could be the stabilization of a peptide receptive class I conformation.

59 BASIC BIOLOGICAL SCIENCES↗

Collocation Methods for Exploring Perturbations in Linear Stability Analysis

Eigenvalue analysis is a well-established tool for stability analysis of dynamical systems. However, there are situations where eigenvalues miss some important features of physical models. For example, in models of incompressible fluid dynamics, there are examples where linear stability analysis predicts stability but transient simulations exhibit significant growth of infinitesimal perturbations. This behavior can be predicted by pseudospectral analysis. In this study, we show that an approach similar to pseudospectral analysis can be performed inexpensively using stochastic collocation methods and the results can be used to provide quantitative information about instability.In addition, we demonstrate that the results of the perturbation analysis provide insight into the behavior of unsteady flow simulations.

97 MATHEMATICS AND COMPUTING↗