Engineering PapersSearch

SEARCH · Engineering Papers

Results for “transient polymer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Time-resolved spectroscopy of solid poly/1-vinyl naphthalene/ following electron beam pulse radiolysis - Pulse radiolytic studies on polymers

Transient emission studies following pulse radiolysis of solid poly(1-vinyl naphthalene) show existence of excited monomers and two excimers. Quenching experiments indicate that excimers are not formed directly by recombination of ions but probably by trapping of migrating monomeric excitation in preformed traps whose density is approximately one in 1000.

Coulter, D. R.

Anomalous Transients in Chip Polymer Tantalum Capacitors

Contrary to MnO2 tantalum capacitors, transient processes in polymer tantalum capacitors after voltage application might result in anomalously high, ampere-level currents when a capacitor might appear as a short circuit for a time that is much greater than a transient time in MnO2 capacitors. In this work, conditions that cause anomalous transients in different types of polymer tantalum capacitors have been analyzed. Related phenomena that included increasing of capacitance and dissipation factors with voltage, parametric surge current test failures without damage to capacitors, and increasing leakage currents at low temperatures are described. It has been shown that anomalous transients increased substantially with applied voltage and with reduction of moisture content in capacitors caused by storage or operation at high temperatures and/or in vacuum. Different types of capacitors exhibited different level of transients and modification of conductive polymers or process of their application might decrease transient leakage currents substantially. For space applications, the risk of failures related to anomalous transients can be mitigated by special testing procedures to select parts with an acceptable level of transients and by voltage derating.

Tantalum Capacitors

Transient Interfacial Phenomena in Miscible Polymer Systems (TIPMPS)

Almost one hundred years ago Korteweg published a theory of how stresses could be induced in miscible fluids by concentration gradients, causing phenomena that would appear to be the same as with immiscible fluids. Miscible fluids could manifest a transient or effective interfacial tension (EIT). To this day, there has been no definitive experiment to confirm Korteweg's model but numerous fascinating and suggestive experiments have been reported. The goal of TIPMPS is to answer the question: Can concentration and temperature gradients in miscible materials induce stresses that cause convection? Many polymer processes involving miscible monomer and polymer systems could be affected by fluid flow and so this work could help understand miscible polymer processing, not only in microgravity, but also on earth. Demonstrating the existence of this phenomenon in miscible fluids will open up a new area of study for materials science. The science objectives of TIPMPS are: (1) Determine if convection can be induced by variation of the width of a miscible interface; (2) Determine if convection can be induced by variation of temperature along a miscible interface; (3) Determine if convection can be induced by variation of conversion along a miscible interface An interface between two miscible fluids can best be created via a spatially-selective photopolymerization of dodecyl acrylate with a photoinitiator, which allows the creation of precise and accurate concentration gradients between polymer and monomer. Optical techniques will be used to measure the refractive index variation caused by the resultant temperature and concentration fields. The viscosity of the polymer will be measured from the increase in the fluorescence of pyrene. Because the large concentration and temperature gradients cause buoyancy-driven convection that prevents the observation of the predicted flows, the experiment must be done in microgravity. In this report, we will consider our efforts to estimate the square gradient parameter, k, and our use of the estimates in modeling of the planned TIPMPS experiments. We developed a model consisting of the heat and diffusion equations with convective terms and of the Navier-Stokes equations with an additional volume force written in the form of the Korteweg stresses arising from nonlocal interaction in the fluid. The fluid's viscosity dependence on polymer conversion and temperature was taken from measurements of poly(dodecyl acrylate). Numerical modeling demonstrated that significant flows would arise for conditions corresponding to the planned experiments.

Pojman, John A.

Flow-induced birefringence measurement system using dual-crystal transverse electro-optic modulator for microgravity fluid physics applications

We have developed a new instrument that can measure fast transient birefringence and polymer chain orientation angle in complex fluids. The instrument uses a dual-crystal transverse electro-optic modulator with the second crystal's modulation voltage applied 180 deg out of phase from that of the first crystal. In this manner, the second crystal compensates for the intrinsic static birefringence of the first crystal, and it doubles the modulation depth. By incorporating a transverse electro-optic modulator with two lithium-niobate (LiNbO3) crystals oriented orthogonal to each other with a custom-designed optical system, we have produced a very small robust instrument capable of fast transient retardation measurements. By measuring the sample thickness or optical path length through the sample, we can calculate the transient birefringence. This system can also measure dichroism. We have compared the calibration results and retardation and orientation angle measurements of this instrument with those of a photoelastic modulator (PEM) based system using a quarter wave plate and a high-precision 1/16-wave plate to simulate a birefringent sample. Transient birefringence measurements on the order of 10(exp -9) can be measured using either modulator.

Mackey, Jeffrey R.

Thermoplastic polyimide NEW-TPI (trademark)

Thermal and rheological properties of a commercial thermoplastic polyimide, NEW-TPI (trademark), were characterized. The as-received material possesses initially a transient crystallite form with a bimodal distribution in peak melting temperatures. After the melting of the initial crystallite structure, the sample can be recrystallized by various thermal treatments. A bimodal or single modal melting peak distribution is formed for annealing temperatures below or above 360 C, respectively. The recrystallized crystallinities are all transient in nature. The polymers are unable to be recrystallized after being subjected to elevated temperature annealing above 450 C. The recrystallization mechanism was postulated, and a simple kinetics model was found to describe the behavior rather satisfactory under the conditions of prolonged thermal annealing. Rheological measurements made in the linear viscoelastic range support the evidence observed in the thermal analysis. Furthermore, the measurements sustain the manufacturer's recommended processing window of 400 to 420 C for this material.

Hou, Tan-Hung

Characterization of thermoplastic polyimide NEW-TPI

Thermal and rheological properties of a commercial thermoplastic polyimide, NEW-TPI, were characterized. The as-received material possesses initially a transient crystallite form with a bimodal distribution in peak melting temperatures. After the meltings of the initial crystallite structures, the sample can be recrystallized by various thermal treatments. A bimodal or single-modal melting peak distribution is formed for annealing temperatures below or above 360 C, respectively. The recrystallized crystallinities are all transient in nature. The polymers are unable to be recrystallized after being subjected to elevated temperature annealing above 450 C. The recrystallization mechanism was postulated, and a simple kinetics model was found to describe the behavior satisfactorily under conditions of prolonged thermal annealing.

Hou, T. H.

Modeling of the transient ignition of a nonmetal/oxygen system by heterogeneous reaction - Effects of oxygen pressure

A theoretical model of the transient ignition of a nonmetallic polymer in a pure oxygen environment was developed and used to assess the safety of an oxygen system under elevated pressure. Results demonstrated that, for a general oxygen system, the ignition temperautre is sensitive to the external heating rate as well as such system parameters as the minimum ignition heat flux and the corresponding minimum ignition temperature. As the oxygen pressure increases, the minimum ignition temperature decreases, until, at a sufficiently high oxygen pressure, spontaneous ignition occurs. Numerical results generated by the model were correlated with the reported ignition data for polyethylene, Teflon, and nylon.

Yuen, Walter W.

Molecular Probe Fluorescence Monitoring of Polymerization

This project investigated the feasibility of using fluorescence spectroscopy to determine viscosity of polymer/monomer in support of Transient Interfacial Phenomena in Miscible Polymer Systems (TIPMPS). This project will attempt to measure gradient induced flow at a miscible interface during and / or after in-flight polymerization of dodecyl acrylate (lauryl acrylate). Concentration and temperature gradients will be intentionally introduced during polymerization and the resultant fluid flow determined by Particle Imaging Velocimetry (PIV). This report describes an investigation of the feasibility of using fluorescence of a probe molecule to monitor viscosity and/or concentration during and after polymerization. The probe used was pyrene which has been shown to be sensitive to its local environment in methyl methacrylate.

Patrick Bunton

Frontal Polymerization in Microgravity Summary of Research

The project began with frontal polymerization (FP). We studied many aspects of FP on the ground and performed two successful weeks of flying on the KC-135. The project evolved into the current flight investigation, Transient Interfacial Phenomena in Miscible Polymer Systems (TIPMPS), as we recognized that an essential question could best be studied using a non-frontal approach. We present detailed results from our ground-based work on FP, KC-135 results and the background, justification and numerical work for the TIPMPS project.

Pojman, John A.

Viscoelastic properties of entangled polymers - Ternary blends of monodisperse homopolymers

In a previous publication from this laboratory, the Rouse-Bueche-Zimm molecular theory of viscoelasticity has been extended by using a transient network model to apply to binary blends of monodisperse polymers with chain entanglements. The dynamics of the entanglements were modeled both by the enhanced frictional coefficients and by the additional elastic couplings. It was recognized that entanglements not only may form between chains of the same lengths (intracomponent entanglements) but also between those of different lengths (intercomponent entanglements). At a given intercomponent entanglement, the longer chain was assumed to have the frictional coefficient of the shorter chain. Similarly, for blends consisting of several monodisperse components with different molecular weights, such modifications are also required to predict their linear viscoelastic behavior. The frequency of these interactions is assumed to be proportional to the weight ratio of the respective component chains in the blend. Equations of motion are formulated for each component and solved numerically for the relaxation time spectra. Linear viscoelastic properties such as the dynamic mechanical moduli, stress relaxation moduli, and zero-shear viscosity can then be computed for these systems by linear summation of those of the components.

Soong, D.

Characterization of individual polynucleotide molecules using a membrane channel

We show that an electric field can drive single-stranded RNA and DNA molecules through a 2.6-nm diameter ion channel in a lipid bilayer membrane. Because the channel diameter can accommodate only a single strand of RNA or DNA, each polymer traverses the membrane as an extended chain that partially blocks the channel. The passage of each molecule is detected as a transient decrease of ionic current whose duration is proportional to polymer length. Channel blockades can therefore be used to measure polynucleotide length. With further improvements, the method could in principle provide direct, high-speed detection of the sequence of bases in single molecules of DNA or RNA.

NASA Discipline Exobiology

[Results of Simulation Studies]

Lattice Monte Carlo and off-lattice molecular dynamics simulations of h(sub 1)t(sub 4) and h(sub 4)t(sub l) (head/tail) amphiphile solutions have been performed as a function of surfactant concentration and temperature. The lattice and off-lattice systems exhibit quite different self-assembly behavior at equivalent thermodynamic conditions. We found that in the weakly aggregating regime (no preferred-size micelles), all models yield similar micelle size distributions at the same average aggregation number, albeit at different thermodynamic conditions (temperatures). In the strongly aggregating regime, this mapping between models (through temperature adjustment) fails, and the models exhibit qualitatively different micellization behavior. Incipient micellization in a model self-associating telechelic polymer solution results in a network with a transient elastic response that decays by a two-step relaxation: the first is due to a heterogeneous jump-diffusion process involving entrapment of end-groups within well-defined clusters and this is followed by rapid diffusion to neighboring clusters and a decay (terminal relaxation) due to cluster disintegration. The viscoelastic response of the solution manifests characteristics of a glass transition and entangled polymer network.

Source record

Measurement Of Molecular Mobilities Of Polymers

New molecular-probe technique used to measure molecular mobility of polymer. Method based on use of time-resolved electron-spin resonance (ESR) spectroscopy to monitor decay of transient nutation amplitudes from photoexcited triplet states of probe molecules with which polymer is doped. The higher molecular mobility of polymer matrix, the faster nutation amplitudes of the probe molecules decay.

Kim, Soon Sam

Modeling of Failure for Analysis of Triaxial Braided Carbon Fiber Composites

In the development of advanced aircraft-engine fan cases and containment systems, composite materials are beginning to be used due to their low weight and high strength. The design of these structures must include the capability of withstanding impact loads from a released fan blade. Relatively complex triaxially braided fiber architectures have been found to yield the best performance for the fan cases. To properly work with and design these structures, robust analytical tools are required that can be used in the design process. A new analytical approach models triaxially braided carbon fiber composite materials within the environment of a transient dynamic finite-element code, specifically the commercially available transient dynamic finite-element code LS-DYNA. The geometry of the braided composites is approximated by a series of parallel laminated composites. The composite is modeled by using shell finite elements. The material property data are computed by examining test data from static tests on braided composites, where optical strain measurement techniques are used to examine the local strain variations within the material. These local strain data from the braided composite tests are used along with a judicious application of composite micromechanics- based methods to compute the stiffness properties of an equivalent unidirectional laminated composite required for the shell elements. The local strain data from the braided composite tests are also applied to back out strength and failure properties of the equivalent unidirectional composite. The properties utilized are geared towards the application of a continuum damage mechanics-based composite constitutive model available within LS-DYNA. The developed model can be applied to conduct impact simulations of structures composed of triaxially braided composites. The advantage of this technology is that it facilitates the analysis of the deformation and damage response of a triaxially braided polymer matrix composite within the environment of a transient dynamic finite-element code such as LS-DYNA in a manner which accounts for the local physical mechanisms but is still computationally efficient. This methodology is tightly coupled to experimental tests on the braided composite, which ensures that the material properties have physical significance. Aerospace or automotive companies interested in using triaxially braided composites in their structures, particularly for impact or crash applications, would find the technology useful. By the development of improved design tools, the amount of very expensive impact testing that will need to be performed can be significantly reduced.

Goldberg, Robert K.

Differential changes in size distribution of xyloglucan in the cell walls of gravitropically responding Pisum sativum epicotyls

Growth-related change in the size distribution of hemicellulosic wall polymers during the gravitropic curvature response of intact pea (Pisum sativum L. cv Alaska) epicotyls was examined by gel-filtration chromatography. The gravitropic response was characterized by the appearance of curvature 20 to 30 min after horizontal placement, with 35 degrees of curvature attained by 80 min. Correlated with the onset of curvature, on the upper side of the epicotyl, there was a conspicuous transient increase in the abundance of relatively large hemicellulosic xyloglucan polymers, similar to increases previously found under conditions where diminished wall extensibility was expected. On the lower side there was a moderate, slower, and longer-term increase in abundance of small xyloglucan, similar to changes previously found in connection with auxin-stimulated growth responses. Both shifts occurred primarily in the epidermis. They appear to represent two coordinated physiological mechanisms contributing to differential growth.

Non-NASA Center

Finite element analysis of nonisothermal polymer processing operations

A finite element formulation for the analysis of polymer processing is presented and its use in some typical situation including entry flow, transient Couette flow, and the Graetz (forced convection) problem is illustrated. The element formulations are constructed on the premise that momentum convection can be neglected (polymer melt flows typically have very low Reynolds' numbers), but that convective heat transfer may be significant (high Peclet numbers). Nonisothermal effects are considered important in polymer processing, due in part to the significant heating which may occur due to viscous dissipation, and also to the very strong influence of temperature on fluid viscosity. The flow is treated as Newtonian with the flow field being coupled to the heat transfer equation only through the viscous heat generation.

Douglas, C.

The Extensional Rheology of Non-Newtonian Materials

The evolution of the transient extensional stresses in dilute and semi-dilute viscoelastic polymer solutions are measured with a filament stretching rheometer of a design similar to that first introduced by Sridhar, et al. The solutions are polystyrene-based (PS) Boger fluids that are stretched at constant strain rates ranging from 0.6 less than or equal to epsilon(0) less than or equal to 4s(exp -1) and to Hencky strains of epsilon greater than 4. The test fluids all strain harden and Trouton ratios exceeding 1000 are obtained at high strains. The experimental data strain hardens at lower strain levels than predicted by bead-spring FENE models. In addition to measuring the transient tensile stress growth, we also monitor the decay of the tensile viscoelastic stress difference in the fluid column following cessation of uniaxial elongation as a function of the total imposed Hencky strain and the strain rate. The extensional stresses initially decay very rapidly upon cessation of uniaxial elongation followed by a slower viscoelastic relaxation, and deviate significantly from FENE relaxation predictions. The relaxation at long times t is greater than or equal to 5 s, is compromised by gravitational draining leading to non-uniform filament profiles. For the most elastic fluids, partial decohension of the fluid filament from the endplates of the rheometer is observed in tests conducted at high strain rates. This elastic instability is initiated near the rigid endplate fixtures of the device and it results in the progressive breakup of the fluid column into individual threads or 'fibrils' with a regular azimuthal spacing. These fibrils elongate and bifurcate as the fluid sample is elongated further. Flow visualization experiments using a modified stretching device show that the instability develops as a consequence of an axisymmetry-breaking meniscus instability in the nonhomogeneous region of highly deformed fluid near the rigid endplate.

Spiegelberg, Stephen H.

The Considere Condition and Rapid Stretching of Linear and Branched Polymer Melts

We analyze the onset of "necking" and subsequent filament failure during the transient uniaxial elongation of viscoelastic fluid samples in extensional rheometers. In the limit of rapid elongation (such that no molecular relaxation occurs), the external work applied is all stored elastically and the Considere criterion originally developed in solid mechanics can be used to quantitatively predict the critical Hencky strain to failure. By comparing the predictions of the Doi-Edwards model for linear homopolymer melts with those of the "Pom-Pom" model for prototypical branched melts we show that the critical strain to failure in rapid elongation of a rubbery material is intimately linked to the molecular topology of the chain, especially the degree of chain branching. The onset of necking instability is monotonically shifted to larger Hencky strains as the number of branches is increased. Numerical computations at finite Deborah numbers also show that there is an optimal range of deformation rates over which homogeneous extensions can be maintained to large strain. We also consider other rapid homogeneous stretching deformations, such as biaxial and planar stretching, and show that the degree of stabilization afforded by inclusion of material with long-chain branching is a sensitive function of the imposed mode of deformation.

McKinley, Gareth H.