Engineering PapersSearch

SEARCH · Engineering Papers

Results for “transient polymer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Transient Covalent Polymers through Carbodiimide‐Driven Assembly

Biochemical systems make use of out-of-equilibrium polymers generated under kinetic control. Inspired by these systems, many abiotic supramolecular polymers driven by chemical fuel reactions have been reported. Conversely, polymers based on transient covalent bonds have received little attention, even though they have the potential to complement supramolecular systems by generating transient structures based on stronger bonds and by offering a straightforward tuning of reaction kinetics. In this study, we show that simple aqueous dicarboxylic acids give poly(anhydrides) when treated with the carbodiimide EDC. Transient covalent polymers with molecular weights exceeding 15,000 are generated which then decompose over the course of hours to weeks. Disassembly kinetics can be controlled using simple substituent effects in the monomer design. The impact of solvent polarity, carbodiimide concentration, temperature, pyridine concentration, and monomer concentration on polymer properties and lifetimes has been investigated. The results reveal substantial control over polymer assembly and disassembly kinetics, highlighting the potential for fine-tuned kinetic control in nonequilibrium polymerization systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Time-resolved spectroscopy of solid poly/1-vinyl naphthalene/ following electron beam pulse radiolysis - Pulse radiolytic studies on polymers

Transient emission studies following pulse radiolysis of solid poly(1-vinyl naphthalene) show existence of excited monomers and two excimers. Quenching experiments indicate that excimers are not formed directly by recombination of ions but probably by trapping of migrating monomeric excitation in preformed traps whose density is approximately one in 1000.

Coulter, D. R.

Anomalous Transients in Chip Polymer Tantalum Capacitors

Contrary to MnO2 tantalum capacitors, transient processes in polymer tantalum capacitors after voltage application might result in anomalously high, ampere-level currents when a capacitor might appear as a short circuit for a time that is much greater than a transient time in MnO2 capacitors. In this work, conditions that cause anomalous transients in different types of polymer tantalum capacitors have been analyzed. Related phenomena that included increasing of capacitance and dissipation factors with voltage, parametric surge current test failures without damage to capacitors, and increasing leakage currents at low temperatures are described. It has been shown that anomalous transients increased substantially with applied voltage and with reduction of moisture content in capacitors caused by storage or operation at high temperatures and/or in vacuum. Different types of capacitors exhibited different level of transients and modification of conductive polymers or process of their application might decrease transient leakage currents substantially. For space applications, the risk of failures related to anomalous transients can be mitigated by special testing procedures to select parts with an acceptable level of transients and by voltage derating.

Tantalum Capacitors

Photoresponsive polymers for carbodiimide-fueled transient hydrogels

Light- and carbodiimide-responsive hydrogels were synthesized. An “AND” gate was developed using ortho-nitrobenzyl (ONB) protected carboxylic acids in the polymer backbone. Crosslinking was only realized in the presence of both UV stimulus to photocleave the ONB group and carbodiimide fuels to induce anhydride bonds. In the presence of water, the anhydride bonds eventually hydrolyze to carboxylic acids and the system returns to the solution state. The mechanical properties of the out-of-equilibrium hydrogels were investigated using oscillatory rheology to examine the effects of deprotection efficiency, carbodiimide concentration and chain architecture on the hydrogels’ moduli and decrosslinking time. Higher moduli and longer decrosslinking times were found with increased carbodiimide concentration and deprotection efficiency. These discoveries unveil new possibilities for photoresponsive chemically fueled soft materials.

36 MATERIALS SCIENCE

Transient Interfacial Phenomena in Miscible Polymer Systems (TIPMPS)

Almost one hundred years ago Korteweg published a theory of how stresses could be induced in miscible fluids by concentration gradients, causing phenomena that would appear to be the same as with immiscible fluids. Miscible fluids could manifest a transient or effective interfacial tension (EIT). To this day, there has been no definitive experiment to confirm Korteweg's model but numerous fascinating and suggestive experiments have been reported. The goal of TIPMPS is to answer the question: Can concentration and temperature gradients in miscible materials induce stresses that cause convection? Many polymer processes involving miscible monomer and polymer systems could be affected by fluid flow and so this work could help understand miscible polymer processing, not only in microgravity, but also on earth. Demonstrating the existence of this phenomenon in miscible fluids will open up a new area of study for materials science. The science objectives of TIPMPS are: (1) Determine if convection can be induced by variation of the width of a miscible interface; (2) Determine if convection can be induced by variation of temperature along a miscible interface; (3) Determine if convection can be induced by variation of conversion along a miscible interface An interface between two miscible fluids can best be created via a spatially-selective photopolymerization of dodecyl acrylate with a photoinitiator, which allows the creation of precise and accurate concentration gradients between polymer and monomer. Optical techniques will be used to measure the refractive index variation caused by the resultant temperature and concentration fields. The viscosity of the polymer will be measured from the increase in the fluorescence of pyrene. Because the large concentration and temperature gradients cause buoyancy-driven convection that prevents the observation of the predicted flows, the experiment must be done in microgravity. In this report, we will consider our efforts to estimate the square gradient parameter, k, and our use of the estimates in modeling of the planned TIPMPS experiments. We developed a model consisting of the heat and diffusion equations with convective terms and of the Navier-Stokes equations with an additional volume force written in the form of the Korteweg stresses arising from nonlocal interaction in the fluid. The fluid's viscosity dependence on polymer conversion and temperature was taken from measurements of poly(dodecyl acrylate). Numerical modeling demonstrated that significant flows would arise for conditions corresponding to the planned experiments.

Pojman, John A.

Autonomous Changes in Polymer Materials Driven by Chemical Fuels

Time-dependent properties in polymer materials can be achieved through coupling to out-of-equilibrium chemical fuel reactions that mimic biological processes. Through transient changes in bonding in polymers, transient gelation, changes in mechanical stiffness, swelling, self-healing, or self-assembly can be achieved. Recent advances in these categories are discussed. These out-of-equilibrium behaviors enable applications ranging from smart adhesives to actuators for soft robotics. However, challenges remain, including waste accumulation, bio-compatibility, and achieving functionally useful performance. Addressing these issues is essential for advancing the practical use of chemically driven polymer materials and unlocking their full potential for future technologies.

36 MATERIALS SCIENCE

A hereditary integral, transient network approach to modeling permanent set and viscoelastic response in polymers

An efficient numerical framework is presented for modeling viscoelasticity and permanent set of polymers. It is based on the hereditary integral form of transient network theory, in which polymer chains belong to distinct networks each with different natural equilibrium states. Chains continually detach from previously formed networks and reattach to new networks in a state of zero stress. The free energy of these networks is given in terms of the deformation gradient relative to the configuration at which the network was born . A decomposition of the kernel for various free energies allows for a recurrence relationship to be established, bypassing the need to integrate over all time history. The technique is established for both highly compressible and nearly incompressible materials through the use of neo-Hookean, Blatz–Ko, Yeoh, and Ogden-Hill material models. Multiple examples are presented showing the ability to handle rate-dependent response and residual strains under complex loading histories.

Finite element method

Flow-induced birefringence measurement system using dual-crystal transverse electro-optic modulator for microgravity fluid physics applications

We have developed a new instrument that can measure fast transient birefringence and polymer chain orientation angle in complex fluids. The instrument uses a dual-crystal transverse electro-optic modulator with the second crystal's modulation voltage applied 180 deg out of phase from that of the first crystal. In this manner, the second crystal compensates for the intrinsic static birefringence of the first crystal, and it doubles the modulation depth. By incorporating a transverse electro-optic modulator with two lithium-niobate (LiNbO3) crystals oriented orthogonal to each other with a custom-designed optical system, we have produced a very small robust instrument capable of fast transient retardation measurements. By measuring the sample thickness or optical path length through the sample, we can calculate the transient birefringence. This system can also measure dichroism. We have compared the calibration results and retardation and orientation angle measurements of this instrument with those of a photoelastic modulator (PEM) based system using a quarter wave plate and a high-precision 1/16-wave plate to simulate a birefringent sample. Transient birefringence measurements on the order of 10(exp -9) can be measured using either modulator.

Mackey, Jeffrey R.

Thermoplastic polyimide NEW-TPI (trademark)

Thermal and rheological properties of a commercial thermoplastic polyimide, NEW-TPI (trademark), were characterized. The as-received material possesses initially a transient crystallite form with a bimodal distribution in peak melting temperatures. After the melting of the initial crystallite structure, the sample can be recrystallized by various thermal treatments. A bimodal or single modal melting peak distribution is formed for annealing temperatures below or above 360 C, respectively. The recrystallized crystallinities are all transient in nature. The polymers are unable to be recrystallized after being subjected to elevated temperature annealing above 450 C. The recrystallization mechanism was postulated, and a simple kinetics model was found to describe the behavior rather satisfactory under the conditions of prolonged thermal annealing. Rheological measurements made in the linear viscoelastic range support the evidence observed in the thermal analysis. Furthermore, the measurements sustain the manufacturer's recommended processing window of 400 to 420 C for this material.

Hou, Tan-Hung

Characterization of thermoplastic polyimide NEW-TPI

Thermal and rheological properties of a commercial thermoplastic polyimide, NEW-TPI, were characterized. The as-received material possesses initially a transient crystallite form with a bimodal distribution in peak melting temperatures. After the meltings of the initial crystallite structures, the sample can be recrystallized by various thermal treatments. A bimodal or single-modal melting peak distribution is formed for annealing temperatures below or above 360 C, respectively. The recrystallized crystallinities are all transient in nature. The polymers are unable to be recrystallized after being subjected to elevated temperature annealing above 450 C. The recrystallization mechanism was postulated, and a simple kinetics model was found to describe the behavior satisfactorily under conditions of prolonged thermal annealing.

Hou, T. H.

Modeling of the transient ignition of a nonmetal/oxygen system by heterogeneous reaction - Effects of oxygen pressure

A theoretical model of the transient ignition of a nonmetallic polymer in a pure oxygen environment was developed and used to assess the safety of an oxygen system under elevated pressure. Results demonstrated that, for a general oxygen system, the ignition temperautre is sensitive to the external heating rate as well as such system parameters as the minimum ignition heat flux and the corresponding minimum ignition temperature. As the oxygen pressure increases, the minimum ignition temperature decreases, until, at a sufficiently high oxygen pressure, spontaneous ignition occurs. Numerical results generated by the model were correlated with the reported ignition data for polyethylene, Teflon, and nylon.

Yuen, Walter W.

Molecular Probe Fluorescence Monitoring of Polymerization

This project investigated the feasibility of using fluorescence spectroscopy to determine viscosity of polymer/monomer in support of Transient Interfacial Phenomena in Miscible Polymer Systems (TIPMPS). This project will attempt to measure gradient induced flow at a miscible interface during and / or after in-flight polymerization of dodecyl acrylate (lauryl acrylate). Concentration and temperature gradients will be intentionally introduced during polymerization and the resultant fluid flow determined by Particle Imaging Velocimetry (PIV). This report describes an investigation of the feasibility of using fluorescence of a probe molecule to monitor viscosity and/or concentration during and after polymerization. The probe used was pyrene which has been shown to be sensitive to its local environment in methyl methacrylate.

Patrick Bunton

Frontal Polymerization in Microgravity Summary of Research

The project began with frontal polymerization (FP). We studied many aspects of FP on the ground and performed two successful weeks of flying on the KC-135. The project evolved into the current flight investigation, Transient Interfacial Phenomena in Miscible Polymer Systems (TIPMPS), as we recognized that an essential question could best be studied using a non-frontal approach. We present detailed results from our ground-based work on FP, KC-135 results and the background, justification and numerical work for the TIPMPS project.

Pojman, John A.

Programmable hydrogels by combining persistent and transient dynamic bonds

Out-of-equilibrium chemistry is currently being applied to polymer systems to mimic the autonomous behavior of biological materials. In this study, hydrogels with self-healing properties were developed that combine persistent crosslinks from dynamic metal-ligand coordination with transient crosslinks from dynamic anhydride bonds. Polymers containing terpyridine ligands and carboxylic acid groups were synthesized and crosslinked with divalent metal ions (Fe 2+ , Ni 2+ , Co 2+ , Zn 2+ , Cu 2+ ). The coordination bonds from terpyridine–metal coordination impart persistent stability, while transient anhydrides formed on treatment with 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide hydrochloride (EDC) temporarily increase crosslink density. Distinct behaviors are observed depending on the choice of metal, with Ni 2+ forming robust, stable networks; Zn 2+ creating moderately dynamic gels; and Cu 2+ yielding highly dynamic, soft materials. Treatment with EDC increased storage moduli significantly, with transient effects lasting up to 280 min depending on the metal ion. Self-healing experiments demonstrated independent contributions from metal coordination and transient anhydrides, enabling recovery of stress and strain under varying conditions. Additionally, complex and reversible 2D stiffness patterns were generated by spatially controlled EDC treatment of Zn 2+ and Cu 2+ hydrogel films, demonstrating programmability and reusability.

Rajawasam, Chamoni W. H. [Miami University, Oxford

Probing the Mechanism of Cadmium Sulfide Cluster Nucleation and Growth via Sequential Infiltration Synthesis

Few-atom metal chalcogenide clusters may be realized through the sequential infiltration of metal–organic precursors in polymer films. However, the underlying nucleation and growth mechanisms that allow for cluster synthesis with near atomic-scale precision are not fully resolved. The kinetics of the sequential infiltration synthesis (SIS) method that control the nucleation and growth mechanisms of primarily Cd 4 S 4 -core clusters within a poly­(4-vinylpyridine) (P4VP) matrix are probed with in situ UV–visible absorbance spectroscopy. Density functional theory (DFT) calculations that allow simulation of the optical properties of cluster fragments further reveal the thermodynamics that guide cluster growth within the P4VP matrix. Here, we conclude that a reactive capture mechanism for cluster nucleation and growth is dominant, although transient dimethyl cadmium adduction to the polymer backbone may contribute to cluster nucleation under shorter metal–organic purge process conditions. Grazing incidence X-ray diffraction (GI-XRD) and X-ray absorption spectroscopy (XAS) analyses further corroborate the cluster size and atom connectivity throughout the stepwise synthesis.

Jayaweera, Nuwanthaka P. [Argonne National Laborat

Polymer connectivity governs electrophotocatalytic activity in the solid state

The reductive functionalization of inert substrates such as chloroarenes is a critical yet challenging transformation relevant to both environmental remediation and organic synthesis. Combining electricity and light is an emerging strategy to access the deeply reducing potentials required for single electron transfer to chloroarenes, yet this approach is limited by poor stability and mechanistic ambiguity. Here, in this work, we demonstrate heterogeneous electrophotocatalysis using redox-active rylene diimide polymers for the reduction of chloroarenes. We find that the electrophotocatalytic activity varies dramatically as a function of the rylene diimide and the redox-inactive polymer backbone. In particular, a flexible, non-conjugated perylenediimide polymer outperforms all other tested electrophotocatalysts. Transient absorption spectroscopy reveals that precomplexation between the doubly reduced perylenediimide and the haloarene substrate is key to productive catalysis. Overall, this work highlights heterogeneous electrophotocatalysis using insoluble redox-active organic materials and provides critical structure–property insights into solid-state electrophotocatalytic activity, informing the development of next-generation materials for sustainable synthesis.

electrocatalysis

Exploring the Photophysics of N-Type Polymer N2200

The polymer interphase is a complex environment comprised of polymer chains, solvent molecules, and electrolyte ions. However, the microenvironments that these ingredients produce is both poorly-understood and difficult to investigate given the system's inherent structural heterogeneity. Nonetheless, a fundamental understanding of the structure, electrochemical behavior, and excited-state dynamics is a key prerequisite to optimizing devices based on such a system - for instance, photoelectrochemical cells for the direct, light-driven production of solar hydrogen, which may minimize efficiency losses compared to sequential light harvesting and electrochemical hydrogen production in separate but linked devices. This work combines transient absorption (TA) spectroscopy, which is a powerful tool for the observation of a variety of excited states on a femto- to microsecond timescale, with time-resolved microwave conductivity (TRMC) spectroscopy, which selectively probes the dynamics of free charge carriers (FC), of a blend of a donor polymer (PTB7-Th) and acceptor polymer (N2200) in a bulk heterojunction. Initial results indicate an extension of FC lifetime and homogenization of the microenvironment on a whole-film level, not just at the surface of the polymer; however, many questions are still under active investigation, including the changes in energy of the involved polaron states, effective conjugation length, FC mobility and migration distance, etc. Additional experiments regarding the photoinitiated behavior of the blend in different environments and on different timescales are ongoing.

charge recombination