Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transient plasma”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Observations of Plasma Transient on the Lobe Field Line During the Substorm. Interball Tail Observations on October 3, 1995

On October 3, 1995 Interball Tail spacecraft was located on tail lobe field lines. Solar wind conditions monitored by WIND and Getail spacecraft were quiet stable. During the time of operation of SCA-1 plasma spectrometer typical plasma mantle is observed. However, at approx. 15:07 UT strong plasma transient with duration of approx. 10 minutes was detected. We found that magnetic field profile of this plasma transient correlates well with ground based H component of magnetic field measured by Tixie Bay station. Ground base data indicates that this transient is observed during strong substorm. We argue that this transient is probably more dense mantle plasma which can be observed at the Interball Tail location provided that the current on the magnetopause is depressed. This depression probably reflects response of the tail magnetopause to changing of the global current system of the magnetosphere caused by the substorm.

Avanov, L. A.↗

Detailed measurements of the H beta line shape in a transient plasma using a fiber optics slit system

Through the use of fiber optics, a series of very narrow slits have been constructed and placed at the exit plane of a spectrograph. Plasma radiation which is dispersed by the spectrograph is incident on the slits and is transmitted to separate phototubes via the quartz fibers. With this technique, time resolved measurements of the spectral shape of the hydrogen H beta line have been made and used to determine the electron density of a transient plasma. Data obtained in a shock tube indicated that the thermodynamic conditions behind the reflected shock in a mixture of 20 percent H 80 percent He correspond to theoretically predicted conditions.

Stickford, G. H., Jr.↗

Detailed measurements of the H beta line shape in a transient plasma using a fiber optics slit system.

Through the use of fiber optics, a series of very narrow slits have been constructed and placed at the exit plane of a spectrograph. Plasma radiation which is dispersed by the spectrograph is incident on the slits and is transmitted to separate phototubes via the quartz fibers. With this technique, time resolved measurements of the spectral shape of the hydrogen H beta line have been made and used to determine the electron density of a transient plasma. Data obtained in a shock tube indicated that the thermodynamic conditions behind the reflected shock in a mixture of 20% H2-80% He, at incident shock speeds of 12 to 14 km/sec and pressures of 66.6 to 133.3 N/sq m (0.5 to 1.0 mm Hg), correspond to theoretically predicted conditions. Immediately behind the incident shock at speeds of 17 to 24 km/sec the data indicate that the plasma reached equilibrium then demonstrated a drop in intensity which has been attributed to radiative cooling.

Stickford, G. H., Jr.↗

An investigation of transient pressure and plasma properties in a pinched plasma column

The transient pinched plasma column generated in a linear Z-pinch was studied experimentally and analytically. The plasma column was investigated experimentally with the following plasma diagnostics: a special rapid response pressure transducer, a magnetic field probe, a voltage probe and discharge luminosity. Axial pressure profiles on the discharge chamber axis were used to identify three characteristic regions of plasma column behavior; they were in temporal sequence: strong axial pressure asymmetry noted early in plasma column lifetime followed by plasma heating in which there is a rapid rise in static pressure and a slight decrease static pressure before plasma column breakup. Plasma column lifetime was approximately 5 microseconds. The axial pressure asymmetry was attributed to nonsimultaneous pinching of the imploding current sheet along the discharge chamber axis. The rapid heating is attributed in part to viscous effects introduced by radial gradients in the axial streaming velocity. Turbulent heating arising from discharge current excitation of the ion acoustic wave instability is also considered a possible heating mechanism.

Stover, E. K.↗

An investigation of transient pressures and plasma properties in a pinched plasma column

The transient pinched plasma column generated in a linear Z-pinch was studied experimentally and analytically. The plasma column was investigated experimentally with several plasma diagnostics; they were: a rapid response pressure transducer, a magnetic field probe, a voltage probe, and discharge luminosity. Axial pressure profiles on the discharge chamber axis were used to identify three characteristic regions of plasma column behavior: (1) strong axial pressure asymmetry noted early in plasma column lifetime, (2) followed by plasma heating in which there is a rapid rise in static pressure, and (3) a slight decrease static pressure before plasma column breakup. Plasma column lifetime was approximately 5 microseconds. The axial pressure asymmetry was attributed to nonsimultaneous pinching of the imploding current sheet along the discharge chamber axis. The rapid heating could be attributed in part to viscous effects introduced by radial gradients in the axial streaming velocity.

Stover, E. K.↗

Behavior of Triple Langmuir Probes in Non-Equilibrium Plasmas

The triple Langmuir probe is an electrostatic probe in which three probe tips collect current when inserted into a plasma. The triple probe differs from a simple single Langmuir probe in the nature of the voltage applied to the probe tips. In the single probe, a swept voltage is applied to the probe tip to acquire a waveform showing the collected current as a function of applied voltage (I-V curve). In a triple probe three probe tips are electrically coupled to each other with constant voltages applied between each of the tips. The voltages are selected such that they would represent three points on the single Langmuir probe I-V curve. Elimination of the voltage sweep makes it possible to measure time-varying plasma properties in transient plasmas. Under the assumption of a Maxwellian plasma, one can determine the time-varying plasma temperature T(sub e)(t) and number density n(sub e)(t) from the applied voltage levels and the time-histories of the collected currents. In the present paper we examine the theory of triple probe operation, specifically focusing on the assumption of a Maxwellian plasma. Triple probe measurements have been widely employed for a number of pulsed and timevarying plasmas, including pulsed plasma thrusters (PPTs), dense plasma focus devices, plasma flows, and fusion experiments. While the equilibrium assumption may be justified for some applications, it is unlikely that it is fully justifiable for all pulsed and time-varying plasmas or for all times during the pulse of a plasma device. To examine a simple non-equilibrium plasma case, we return to basic governing equations of probe current collection and compute the current to the probes for a distribution function consisting of two Maxwellian distributions with different temperatures (the two-temperature Maxwellian). A variation of this method is also employed, where one of the Maxwellians is offset from zero (in velocity space) to add a suprathermal beam of electrons to the tail of the main Maxwellian distribution (the bump-on-the-tail distribution function). For a range of parameters in these non-Maxwellian distributions, we compute the current collection to the probes. We compare the distribution function that was assumed a priori with the distribution function one would infer when applying standard triple probe theory to analyze the collected currents. For the assumed class of non-Maxwellian distribution functions this serves to illustrate the effect a non-Maxwellian plasma would have on results interpreted using the equilibrium triple probe current collection theory, allowing us to state the magnitudes of these deviations as a function of the assumed distribution function properties.

Polzin, Kurt A.↗

Behavior of Langmuir Probes in Non-Equilibrium Plasmas

Langmuir probes are diagnostic tools used to determine electron temperature, number density, and plasma potential. Irving Langmuir first used an electrostatic probe in the 1920s to find these characteristics in ionized gases. Single, double, and triple Langmuir probes are commonly used in plasma diagnostics because of their relative simplicity. In the single probe, a swept voltage is applied between the probe tip and circuit common to acquire a waveform showing the collected current as a function of applied voltage. A double Langmuir probe consists of two tips, both inserted into the plasma, with a voltage applied between them. As this voltage is swept, a current-voltage characteristic is measured. In a triple probe three probe tips are electrically coupled to each other with constant non-swept voltages applied between each of the tips. The voltages are selected to represent three points on the single Langmuir probe I-V curve. Elimination of the voltage sweep makes it possible to measure time-varying plasma properties in transient plasmas. Triple Langmuir probe measurements have been widely employed for various types of plasmas, including pulsed and time-varying plasmas such as those seen in pulsed plasma thrusters (PPTs), dense plasma focus devices, plasma flows, and fusion experiments. The typical Langmuir probe analysis for determining electron temperature and number density of the plasma (for a single, double, or triple Langmuir probe) includes an assumption that the plasma is in thermal equilibrium. While the this assumption may be justified for some applications, it is unlikely that it is fully justifiable for pulsed and time-varying plasmas or for the entire time a plasma device is in use. In the present work, we model the responses of Langmuir probes as they are inserted into a range of simple equilibrium and non-equilibrium plasmas. We return to basic governing equations of probe current collection and compute the current to the probes for a distribution function consisting of two Maxwellian distributions with different temperatures (the two-temperature Maxwellian). A variation of this method is also employed, where one of the Maxwellians is offset from zero (in velocity space) to add a suprathermal beam of electrons to the tail of the main Maxwellian distribution (the bump-on-the-tail distribution function). For a range of parameters in these non-Maxwellian distributions, we compute the current collection to the probes. Comparing the distribution function that was assumed a priori with the plasma density and temperature one would infer when applying standard probe theory to analyze the collected currents serves to illustrate the effect a non- Maxwellian plasma would have on results interpreted using the equilibrium probe current collection theory, allowing us to state the magnitudes of these deviations as a function of the assumed distribution function properties.

Polzin, Kurt A.↗

Collisionless electron shocks in electron-beam-plasma systems

One-dimensional Vlasov simulations show that when an electron beam is suddenly injected into a plasma, a fast-moving monotonic shock forms during the early stage of the transient plasma response. In the shock, the ions are nearly immobile. The shock appears to be an electrostatic electron-beam-plasma mode. The shock evolves from an initial positive potential perturbation, which is supported by an ion burst. The steepening of the perturbation into a shock is characterized by an electron-beam-plasma mode.

Singh, N.↗

A multiple-scattering approach to transient electromagnetic interaction with plasmas

A multiple-scattering method is described which is applicable to the transient plasma problem concerning the interaction between transient electromagnetic waves and plasmas. The method starts with the time-dependent wave fields scattered by a linear electric dipole when illuminated by a transient plane wave. It avoids the use of Fourier transform methods and provides additional physical insight into the origin of the frequency-dispersive properties of material media. The results are applicable only to cold plasmas since spatial dispersion is neglected, implying that effects due to thermal velocities of electrons - such as incoherent scatter - are not covered by the theory. The advantages of the method for initiation of the student into transient electromagnetics in dispersive media are identified as conceptual simplicity and computational simplicity. The entire analysis is in the time domain.

Bowhill, S. A.↗

Ionospheric plasma flow over large high-voltage space platforms. I - Ion-plasma-time scale interactions of a plate at zero angle of attack. II - The formation and structure of plasma wake

The paper presents the theory and particle simulation results for the ionospheric plasma flow over a large high-voltage space platform at a zero angle of attack and at a large angle of attack. Emphasis is placed on the structures in the large, high-voltage regime and the transient plasma response on the ion-plasma time scale. Special consideration is given to the transient formation of the space-charge wake and its steady-state structure.

Wang, J.↗

Three-dimensional currents of electrodynamic tethers obtained from laboratory models

Magnetic probe measurements in three dimensions (greater than 15,000 positions) and time in a large laboratory plasma (n(sub e) greater than or equal to 10(exp 11)/cc, kTe greater than or equal to 1eV, B(sub 0) = 20 G, 1 m diam. x 2.5 m length) reveal the plasma currents J = del(vector differential operator) x B/mu(sub 0) excited by a pulsed (delta-t = 100 ns), stationary, tethered pair of electrodes (approximately equals 1 cm diam., 20 cm spacing perpendicular to B(sub 0)). The plasma currents for a moving, dc-current carrying electrodynamic tether are obtained by a superposition of delayed pulses emitted at successively displaced tether positions. The transient plasma currents are carried by low-frequency whistlers instead of Alfven waves and form a 3D wing structure but no long phantom loop due to cross-field Hall current shunting.

Urrutia, J. M.↗

Dayside Magnetopause Transients Correlated with Changes of the Magnetosheath Magnetic Field Orientation

The paper analyses one long-term pass (26 August 2007) of the THEMIS spacecraft across the dayside low-latitude magnetopause. THEMIS B, serving partly as a magnetosheath monitor, observed several changes of the magnetic field that were accompanied by dynamic changes of the magnetopause location and/or the structure of magnetopause layers observed by THEMIS C, D, and E, whereas THEMIS A scanned the inner magnetosphere. We discuss the plasma and the magnetic field data with motivation to identify sources of observed quasiperiodic plasma transients. Such events at the magnetopause are usually attributed to pressure pulses coming from the solar wind, foreshock fluctuations, flux transfer events or surface waves. The presented transient events differ in nature (the magnetopause surface deformation, the low-latitude boundary layer thickening, the crossing of the reconnection site), but we found that all of them are associated with changes of the magnetosheath magnetic field orientation and with enhancements or depressions of the plasma density. Since these features are not observed in the data of upstream monitors, the study emphasizes the role of magnetosheath fluctuations in the solar wind-magnetosphere coupling.

Tkachenko, O.↗