Influence of photon and ion induced secondary yields on transient plasma formation.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Transient plasma induced production of OH is followed in a quiescent, stoichiometric CH{sub 4}-air mixture using the planar laser induced fluorescence technique. Ignition and subsequent flame propagation, for both the transient plasma and traditional spark ignition, are observed with a high speed camera (2000 fps). The transient plasma is generated using a 70 ns FWHM, 60 kV, 800 mJ pulse. OH production was confirmed throughout the chamber volume; however, the mean number density was found to decay below 1.3 x 10{sup 14}cm{sup -3} near 100 {mu}s. Nonetheless, ignition induced by transient plasma was decidedly faster than by spark ignition. Using the high speed camera, ignition initiated by transient plasma was found to occur along the length of the anode at approximately 1 ms, leading to the formation of a wrinkled, cylindrically-shaped flame. Analysis of the flame front propagation rates shows that flames ignited by transient plasma propagate essentially at the speed consistent with well accepted literature values for the stoichiometric methane-air mixture. This supports the notion that residue plasma, if any, has little effect on flame propagation. (author)
Abstract One of the primary basic plasma parameters within transient nonequilibrium plasmas is the reduced electric field strength, roughly understood as the ratio of the electrical energy given to the charged species between two collisions. While physical probes have historically been used for electric field measurements, recent advances in high intensity lasers and sensitive detection methods have allowed for non-invasive optical electric field determination in nearly any discharge configuration with time-resolution up to the sub-nanosecond range and sub-millimeter spatial resolution. This topical review serves to highlight several non-invasive methods for in situ electric field strength determination in transient plasmas ranging from high vacuum environments to atmospheric pressure and above. We will discuss the advantages and proper implementation of (i) laser induced fluorescence dip spectroscopy for measurements in low pressure RF discharges, (ii) optical emission spectroscopy based methods for nitrogen, helium or hydrogen containing discharges, (iii) electric field induced coherent Raman scattering, and (iv) electric field induced second harmonic generation. The physical mechanism for each method will be described as well as basic implementation and highlighting recent results.
The efficiency improvement and emissions reduction potential of lean and EGR dilute operation of spark-ignition gasoline engines is well understood and documented. However, dilute operation is generally limited by deteriorating combustion stability with increasing inert gas levels. The combustion stability decreases due to reduced mixture flame speeds resulting in significantly increased combustion initiation periods and burn durations. A study was designed and executed to evaluate the potential to extend lean and EGR-dilute limits using a low-energy transient plasma ignition system. The low-energy transient plasma was generated by nano-second pulses and its performance compared to a conventional transistorized coil ignition system operated on an automotive, gasoline direct injection (GDI) single-cylinder research engine. The experimental assessment was focused on steady-state experiments at the part load condition of 1500 rpm 5.6 bar IMEP, where dilution tolerance is particularly critical to improving efficiency and emissions performance. Experimental results suggest that the energy delivery process of the low-energy transient plasma ignition system significantly improves part load dilution tolerance by reducing the early flame development period. Statistical analysis of relevant combustion metrics was performed in order to further investigate the effects of the advanced ignition system on combustion stability. Results confirm that at select operating conditions EGR tolerance and lean limit could be improved by as much as 20% (from 22.7 to 27.1% EGR) and nearly 10% (from λ=1.55 to 1.7) with the low-energy transient plasma ignition system.
The efficiency improvement and emissions reduction potential of lean and exhaust gas recirculation (EGR)-dilute operation of spark-ignition gasoline engines is well understood and documented. However, dilute operation is generally limited by deteriorating combustion stability with increasing inert gas levels. The combustion stability decreases due to reduced mixture flame speeds resulting in significantly increased combustion initiation periods and burn durations. A study was designed and executed to evaluate the potential to extend lean and EGR-dilute limits using a low-energy transient plasma ignition system. The low-energy transient plasma was generated by nanosecond pulses and its performance compared to a conventional transistorized coil ignition (TCI) system operated on an automotive, gasoline direct-injection (GDI) single-cylinder research engine. The experimental assessment was focused on steady-state experiments at the part load condition of 1500 rpm 5.6 bar indicated mean effective pressure (IMEP), where dilution tolerance is particularly critical to improving efficiency and emission performance. Experimental results suggest that the energy delivery process of the low-energy transient plasma ignition system significantly improves part load dilution tolerance by reducing the early flame development period. Statistical analysis of relevant combustion metrics was performed in order to further investigate the effects of the advanced ignition system on combustion stability. Results confirm that at select operating conditions EGR tolerance and lean limit could be improved by as much as 20% (from 22.7 to 27.1% EGR) and nearly 10% (from λ = 1.55 to 1.7) with the low-energy transient plasma ignition system.
Proper normalization of a Maxwell-Boltzmann electron distribution in transient plasma models requires the self-consistent calculation of a reference density from a global electron conservation equation. This calculation tends to produce numerical oscillations in the time evolution of the plasma, in particular during the formation of the plasma sheath. The present paper proposes a simple numerical scheme to prevent these oscillations by artificial critical damping, which makes it possible to simulate transient plasma phenomena without electron-related time step conditions.
Based on a previously developed, retrofittable nanosecond pulsed TPS ignition prototype, transient plasma ignition technology is evaluated for higher energy efficiency and lower emission by optimizing pulse power conditions using advanced diagnostic-based approaches. Combustion performances of a TPS ignition electrode powered by nanosecond voltage pulses of two different rising times (i.e. 4 ns and 8 ns) but the same full-width-half-maximum (FWHM) of 6 ns were compared for single-shot and high-repetition-rate ignitions. The use of faster risetime reduces the voltage amplitude criterion for combustion ignition under a single-shot, stoichiometric fuel-air condition, resulting in higher energy efficiency. In addition, it was demonstrated that high-frequency bursts of pulses positively affect the combustion process; four-consecutive pulsed plasma ignition at a pulse repletion rate (PRR) of 1 kHz needs only half of the voltage to achieve combustion, and increasing the PRR from 1 kHz to 10 kHz improves the energy efficiency by a factor of >1.3. A prototype of retrofittable nanosecond pulsed ignition system was developed and tested in a newly built testing/diagnostic platform, paving the way for ultimate optimization of the TPS prototype for low cost, highly efficient, and low emission combustion.
On October 3, 1995 Interball Tail spacecraft was located on tail lobe field lines. Solar wind conditions monitored by WIND and Getail spacecraft were quiet stable. During the time of operation of SCA-1 plasma spectrometer typical plasma mantle is observed. However, at approx. 15:07 UT strong plasma transient with duration of approx. 10 minutes was detected. We found that magnetic field profile of this plasma transient correlates well with ground based H component of magnetic field measured by Tixie Bay station. Ground base data indicates that this transient is observed during strong substorm. We argue that this transient is probably more dense mantle plasma which can be observed at the Interball Tail location provided that the current on the magnetopause is depressed. This depression probably reflects response of the tail magnetopause to changing of the global current system of the magnetosphere caused by the substorm.
Modified laser Michelson interferometer for probing highly transient plasmas occurring behind incident shock waves in shock tubes
Transient phenomena and their control are of high relevance in magnetic confinement fusion plasmas to guarantee a stable and safe plasma operation. Interpretative simulations can maximize the insights gained from experiments on present machines and predictive simulations can help in the preparation of design, mitigation techniques and operational scenarios for future devices. In this article, we provide an overview of recent advances and novel scientific results obtained with the 3D non-linear hybrid fluid-kinetic code JOREK, covering physics of plasma transients from the core to the scrape-off layer (SOL) both for tokamak and stellarator devices. Substantial progress was made in the physics understanding, model validation with experiments and experiment interpretation, thus, giving confidence for predictions to devices like DTT, ITER and DEMO. The topics addressed comprise a wide range: the edge physics of new operation scenarios and edge localized mode suppression; major disruptions with a focus on runaway electrons and vertical displacement events as well as disruption mitigation by shattered pellet injection; the physics mechanisms and operational limits of the flux pumping regime for sawtooth control; MHD limits of stellarators and work towards incorporating advanced edge/SOL/exhaust dynamics; continuing improvements of the code for more efficient hybrid simulations on conventional and accelerated high performance computing architectures.
Miniature Rogowski coil probes for direct measurement of current density distributions in transient plasmas
Spectrographs for measuring hydrogen H beta line spectral shape and determining electron density of transient plasma
Pulsed capillary discharge is a compact device that is used to perform fast electrical discharge that is used to produce transient plasma. In this work, a more economical imaging technique is developed in order to study the dynamics of the plasma that is formed in a capillary tube. The imaging system consists of two main devices, a four-frame gated micro-channel plate and a Nikon Coolpix5000 camera. The time-resolved imaging that we have performed in order to study the dynamics of the plasma that is formed in a 10 mm long and 1 mm diameter low pressure capillary tube is reported. The images obtained portrayed that the plasma is heated up when the magnitude of the current is around the maximum and cools down when the current magnitude is around the minimum.
Pulsed inductively coupled plasmas (ICPs) are widely deployed in the fabrication of semi-conductor devices. Pulse repetition frequencies (PRFs) of up to tens of kHz are commonly used during plasma etching for the high power densities they generate during the pulse-on period, and for their unique chemistries during the pulse-off period. The use of highly attaching halogen gases produces low electron densities during the pulse-off period, and these low density can result in instabilities, E-H transitions and ignition delays when applying power on the next pulse. To mitigate these possibilities, a low-level power environment could be maintained during “pulse-off” to moderate the minimum plasma density, therefore reducing ignition delays and enhancing plasma stability. In this work, ICPs sustained by 5 kHz pulsed power using Ar/Cl 2 mixtures at 20 mTorr were computationally investigated. For these conditions, the computed electron temperature (T e ) reaches a quasi-steady state during both the high- and low-power excitation. The model predicts that within the electromagnetic skin-depth, T e spikes to a high value during a low-to-high power modulation, and to a low value during a high-to-low power modulation. At the same time, a few cm above the substrate, there is little modulation in T e , as electron power convected from the skin depth disperses in traversing the reactor. Finally, the positive and negative spikes, and convection of transients across the reactors, are functions of power ramping time and gas mixtures.
Through the use of fiber optics, a series of very narrow slits have been constructed and placed at the exit plane of a spectrograph. Plasma radiation which is dispersed by the spectrograph is incident on the slits and is transmitted to separate phototubes via the quartz fibers. With this technique, time resolved measurements of the spectral shape of the hydrogen H beta line have been made and used to determine the electron density of a transient plasma. Data obtained in a shock tube indicated that the thermodynamic conditions behind the reflected shock in a mixture of 20 percent H 80 percent He correspond to theoretically predicted conditions.
Through the use of fiber optics, a series of very narrow slits have been constructed and placed at the exit plane of a spectrograph. Plasma radiation which is dispersed by the spectrograph is incident on the slits and is transmitted to separate phototubes via the quartz fibers. With this technique, time resolved measurements of the spectral shape of the hydrogen H beta line have been made and used to determine the electron density of a transient plasma. Data obtained in a shock tube indicated that the thermodynamic conditions behind the reflected shock in a mixture of 20% H2-80% He, at incident shock speeds of 12 to 14 km/sec and pressures of 66.6 to 133.3 N/sq m (0.5 to 1.0 mm Hg), correspond to theoretically predicted conditions. Immediately behind the incident shock at speeds of 17 to 24 km/sec the data indicate that the plasma reached equilibrium then demonstrated a drop in intensity which has been attributed to radiative cooling.
Non-equilibrium plasma generated from positive-pulsed nanosecond electrical discharges into desiccated air is simulated in this paper using a multi-dimensional, multi-physics plasma solver. A pin-to-pin electrode configuration is used with a fixed 5.2 mm gap spacing. Peak pulse voltages range between 10.2 and 22.5 kV. Care is taken to match the exact electrode profile from the experiments, and adjust the electron collision frequency so that breakdown limits closely match those from corresponding experimental results. The optimized numerical simulations predict qualitative streamer structure that is in close agreement with experimental observations. Quantitative measurements of atomic oxygen at the anode tip and qualitative estimates of streamer gas heating are closely matched by simulations. The model results are used to provide insight into the spatial and temporal development of the transient plasma. Furthermore, the work performed in this paper delivers a numerical tool that can be extremely useful to link the post-discharge plasma properties to low-temperature plasma ignition mechanisms that are of great interest for the automotive industry.
Based on a stochastic model for intermittent fluctuations in the boundary region of magnetically confined plasmas, an expression for the level crossing rate is derived from the joint distribution of the process and its derivative. From this the average time spent by the process above a certain threshold level is obtained. This provides novel predictions of plasma–wall interactions due to transient transport events associated with a radial motion of blob-like structures in the scrape-off layer.