Novel Design and Fabrication of a High Frequency Transient Heat Flux Sensor for Use in an RDE

Rotating detonation engine (RDE) combustion systems have been a topic of interest in the pressure gain combustion community for their benefits over traditional gas turbine engine combustors. However, cooling requirements for these engines are significantly higher and less predictable than non-detonating engines. To understand the high-speed heat transfer dynamics inside an RDE, a novel, high-frequency heat flux gage is presented. This study aims to design a robust, single-sided sensor that can withstand the high temperature and harsh environment of an RDE for extended durations. Sensor bench testing is performed using a hot plate as a heat source, and the sensor response is compared to a finite-element analysis (FEA) model. The sensor response is then tested inside a water-cooled RDE and the wall heat flux is compared to calorimetry data.

rotating detonation engines↗

Novel Design and Fabrication of a High Frequency Transient Heat Flux Sensor for Use in an RDE

Rotating detonation engine (RDE) combustion systems have been a topic of interest in the pressure gain combustion community for their benefits over traditional gas turbine engine combustors. However, cooling requirements for these engines are significantly higher and less predictable than non-detonating engines. To understand the high-speed heat transfer dynamics inside an RDE, a novel, high-frequency heat flux gage is presented. This study aims to design a robust, single-sided sensor that can withstand the high temperature and harsh environment of an RDE for extended durations. Sensor bench testing is performed using a hot plate as a heat source, and the sensor response is compared to a finite-element analysis (FEA) model. The sensor response is then tested inside a water-cooled RDE and the wall heat flux is compared to calorimetry data.

rotating detonation engines↗

Active Lithium Injection for a Real Time Control of the Divertor Heat Flux for Fusion Devices

When the local heat flux exceeds specified flux limit, tungsten PFC surfaces can be damaged, which is not acceptable for a reliable reactor operations. The divertor PFCs are typically designed for a specific heat flux limit usually assuming an average steady-state heat flux which is typically 5–10 MW/m 2 . However, in addition to steady-state heat flux, fusion reactor divertor PFCs could experience transient heat fluxes such as ELMs and/or other magnetic reconnection events which can deposit large transient heat fluxes onto the divertor PFCs. The transient divertor heat flux could be significantly larger than the steady-state heat flux which could damage the solid PFC surfaces. The divertor heat flux can be subjected to additional complications such as the uncertainties in the the divertor strike point heat flux projection. Moreover, there are additional experimental observations of non-axisymmetric power flux which can occur under non-axisymmetric magnetic perturbations. The liquid lithium (LL) PFCs is more resilient against such transient heat fluxes as they could evaporate LL as needed and the lost LL can be then replenished afterward. In this paper, we analyze a case for a transient divertor heat pulse of 1 MJ in 10 ms for a ITER-size reactor. This is a small perturbation (~ 0.1%) to the expected plasma stored energy compared to the previously analyzed case of 20 MJ heat pulse. Even with this relatively modest heat pulse, the LL surface undergoes ~ 100 °C temperature rise. However, the resulting LL surface heating without rapid cooldown mechanism could lead to excessive LL evaporation continuing well after the transient heat flux resulting in a significant Li injection of ~ 0.6 mol in about a 200 ms period. This amount of Li injection could cause plasma dilution and performance degradation. On the other hand, an active Li injection capability if optimized could prevent the LL surface temperature rise and thus reducing subsequent Li evaporation into the plasma by a factor of 7 compared to the passive LL PFC case. A crucial tool of active Li injection is a rapid response pellet injector which could inject light impurity pellets before the excessive heat flux could reach the divertor plate causing serious damage. A simple pellet ablation model suggests a favorable pellet deposition profile for smaller ~ 0.1 mm radius pellet with ~ 10–20 m/s velocity. Moreover, if it is possible to inject from the private flux region, the pellet injection efficiency into the high heat flux strike point region can be as high as 80% compared to ~ 50% for the injection from outer radius region. The pellet deposition efficiency can be further improved by designing a shell-pellet which can burst when a certain ablation fraction is reached. Finally, a possible implementation technique using an inductive pellet injector with a rapid time response of a few msec is proposed here which can be tested in NSTX-U.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Flow boiling transient critical heat flux tests with stainless steel and FeCrAl: Transient correlation implementation, model calibration, and sensitivity analysis

In this study, steady-state and transient internal-flow critical heat flux (CHF) experiments were carried out under two flow conditions, at atmospheric pressure, on 316 stainless steel (316-SS) and iron-chromium-aluminum (FeCrAl) tubes. Slow power transients at a low mass flow (300 kg/m 2 - s) with very low subcooling (X e =-0.0054) generated premature CHFs, which were prevented by faster power transients and high mass flow (1000 kg/m 2 - s). The measured transient CHFs increased linearly with increasing power transients, compared with the steady-state CHF. Yet, the wall superheat at the CHFs decreased with faster power transients. Transient CHF correlations highlighting heterogeneous spontaneous nucleation were calibrated to the measured CHFs and compared with other existing correlations. Transient CHF multipliers were acquired from pool and flow boiling empirical CHF correlations that were generated. The multipliers were applied to the RELAP5-3D nuclear system code to analyze the discrepancies between the measured data and the predicted CHF and post-CHF behavior, which improved peak cladding temperature predictions by 24.6%. A variance-based global sensitivity study perturbing the experimental uncertainties and cladding material thermal properties showed the diminishing influence of flow boiling heat transfer with increasing power transients, highlighting the significance of the volumetric heat capacity for the cladding integrity during transients. Transient CHF correlations were applied to the most limiting design basis accident: a hot-zero-power reactivity-initiated accident on a generic pressurized water reactor RELAP5-3D model.

36 MATERIALS SCIENCE↗

Edge-localized-mode simulation in CFETR steady-state scenario

We report the EPED1 model and self-consistent core-pedestal coupling in integrated modeling are used to design the pedestal structure of the China Fusion Engineering Testing Reactor (CFETR) steady-state scenario. The key parameters, such as β p and q 95 , are based on the grassy edge-localized-mode (ELM) experimental database. In this work, we use the BOUT++ six-field two-fluid code to simulate the onset of the ELM in the CFETR steady-state scenario. The ELM size is around 0.2% in nonlinear simulations, which is in the experimental range of the grassy ELM discharges, 0.1%–1% observed in multiple tokamak devices. Linear and nonlinear simulations show that the dominant high-n ballooning modes peak around n = 40. Compared to type-I ELM crashing dynamics, grassy ELM crashing has a smaller initial crash and is then followed by three phases of turbulence spreading, which are dominated by multi-modes, a high-n mode of n = 45 and low-n mode of n = 5, respectively. In contras to type-I ELM, the perturbation of the high-n mode has a narrow width around ψ = 0.95, and magnetic island formation and reconnection occur only beyond ψ = 0.95, leading to a small initial crash. Mode–mode interaction in the multi-mode coexistence stage stops the growth of individual modes and reduces the transport of particles and heat, and these are the two reasons why the ELM size is small. In–out asymmetry of transient heat flux with a ratio of E out /E in = 3.5 is found during grassy ELM crash. The rise and delay times of the heat flux match the calculation from the free-streaming model. To evaluate the erosion of the divertor target, the energy fluence at the outer divertor target is calculated, which is 0.029 MJ m -2 , 5.5 times smaller than the tungsten melting limit 0.16 MJ m -2 . The calculated energy fluency still follows the experimental scaling law from type-I ELM experiments. The fluctuation eddies in the toroidal direction show a filament structure at the outer mid-plane. Parallel heat flux patterns with a toroidal mode number n = 10 are found at the outer divertor with an amplitude of 680 MW m -2 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Divertor heat load estimates on NSTX and DIII-D using new and open-source 2D inversion analysis code

A thermography inversion algorithm has been developed in the open-source Python-based computer code, HYPERION, to calculate the heat flux incident on plasma-facing components (PFCs) in axisymmetric tokamaks. The chosen mesh size at the surface significantly affects the calculated transient heat flux results. The calculated transient heat flux will exceed the real value when the mesh size tends to zero but will underestimate the real value when the mesh size is large. A criterion for determining the appropriate mesh size for the transient heat flux calculation will be discussed. The numerical scheme for HYPERION uses a 2D fully implicit finite-difference approach, allowing temperature-dependent thermal properties of PFC materials. The inversion algorithm is benchmarked against established heat flux calculation codes, TACO and THEODOR, based on thermography data from NSTX and DIII-D respectively. The primary benefits of HYPERION compared to TACO and THEODOR are that it is open-source and it allows for the optimization of mesh thickness along the substrate. The algorithm also accounts for the thermal properties of thin surface layers that characteristically form on PFCs due to plasma-material interactions. The agreement between HYPERION and THEODOR is excellent, as the percent difference between the codes is ~5% on average in the case of the DIII-D data for moderate to high heat flux. Verification tests with TACO show slightly higher average percent differences of 8% and 12%. In using HYPERION to study filaments in heat flux, the initial results indicate that small ELMs filaments significantly broaden the divertor heat flux, and decrease divertor peak flux. Compared to the inter-ELM, the small ELM filaments decrease the divertor peak surface temperature. With intermittent divertor filaments, the divertor heat flux width is comparable with that found in L-mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Edge localized mode characteristics and divertor heat flux during stationary and transient phase for CFETR hybrid scenario

The study of edge localized mode (ELM) behavior, stationary heat flux and transient heat flux during the ELM crash phase is performed for a China Fusion Engineering Test Reactor (CFETR) 1 GW hybrid mode operation scenario ($R$ = 7.2 m, ${B_{\text{T}}}$ = 6.5 T, ${I_{\text{p}}}$ = 13.78 MA). Modeling and simulation start with a scenario obtained by multi-code integrated modeling on the one modeling framework for integrated tasks framework. Linear stability and nonlinear simulations of ELM dynamics are carried out using the BOUT++ six-field reduced magnetohydrodynamic module, which show a much smaller ELM energy loss (Δ ELM ~ 0.13%) compared to that of a Type-I ELM. Parametric analysis of the weak linear growth rate and small ELM energy loss characteristics shed light on physics corresponding to a grassy ELM regime for CFETR 1 GW hybrid scenario. The transient heat flux on the divertor target during this small ELM phase is investigated using BOUT++. Here we found that upstream radial transport in the scrape-off-layer (SOL) induced by small ELMs is weak, which keeps it in the drift-dominated region. However, the heat flux width is still broadened to ${\lambda _{\text{q}}}$ = 4.64 mm by the increase of separatrix temperature during ELM nonlinear evolution. The impact of transient peak heat load and ELM energy fluence on tungsten melting and net erosion rate of divertor target is evaluated for the first-time using physics-based transport that connects the pedestal with the SOL. Energy fluence caused by a single ELM pulse is below the tungsten melting limit, while tungsten erosion would exceed the material requirements. We conclude that external mitigation methods, such as divertor detachment and advanced divertor geometry are likely needed for the steady state operation of CFETR.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sensitivity Analysis of Transient Critical Heat Flux by RIA Under High-Pressure Flow Boiling Conditions in TRTL

A reactivity-initiated accident (RIA) is a design-basis accident under which critical heat flux (CHF) is likely to be exceeded. The operational margin for RIAs is currently determined using steady-state CHF lookup tables, which provide conservative estimates relative to transient CHF phenomena. The Transient Reactor Test Loop (TRTL) facility at Oregon State University is capable of performing out-of-pile rapid heating experiments representative of a RIA at conditions representative of a pressurized water reactor (PWR). Here, to further our understanding of and ability to predict transient CHF under PWR conditions, we performed a sensitivity analysis on a RELAP5-3D model of the TRTL facility coupled to the RAVEN code framework to define a proposed experimental test matrix to be performed at the TRTL facility. We then implemented a flow boiling CHF correlation into RELAP5-3D and performed a secondary sensitivity analysis inspecting the impact of the built-in RELAP5-3D CHF and heat transfer multipliers on both the prediction of CHF and key safety parameters, such as peak cladding temperature and heat flux. The results show that the multiplier with the highest influence toward the prediction of CHF occurrence and the safety parameters is the transient CHF multiplier. Operational performance envelopes have been developed for each of the test matrix cases and will be used for validation once the experiments are performed. The TRTL facility is currently performing shakedown testing to verify system performance prior to proceeding with the experimental campaign. Restart testing results include pump curve restart testing, pressure tests, and heater rod thermocouple transients.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simulations of heat fluxes in an ELMy H-mode discharge on HL-2A

In order to study the distribution and evolution of the transient heat flux on HL-2A during edge-localized-mode (ELM) bursts, the BOUT++ electromagnetic six-field two-fluid model is used to simulate the pedestal collapse under the lower single-null divertor geometry. The equilibrium profiles of HL-2A ELMy H-mode discharge No. 24 953 are adopted as the initial condition in the original case. In this instance, linear analysis shows that the resistive ballooning mode (RBM) and drift-Alfven wave are unstable to this equilibrium, and RBM is the dominant instability. The evolutions of the radial heat fluxes at the outer mid-plane and heat fluxes to the inner and outer targets during the ELM event are presented. Six more equilibria are constructed based on the original case to find out the influence of the pedestal profiles on the peak electron heat flux. The results indicate that the heat flux increases with temperature and/or density, and the theoretical analysis and simulation results consistently show that the heat flux q ∥e is proportional to n e0,SEP $T^{\frac32}_{e0,SEP}$.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-domain theory of transient heat conduction in the local limit

Ultrafast and nanoscale heat conduction demands a unified theoretical framework that rigorously bridges macroscopic transport equations with microscopic material properties derived from statistical physics. Existing empirical generalizations of Fourier's law often lack a solid microscopic foundation, failing to connect observed non-Fourier behavior with underlying atomic-scale mechanisms. In this work, we present a time-domain theory of transient heat conduction rooted in Zwanzig's statistical theory of irreversible processes. Central to this framework is the time-domain transport function $\overleftrightarrow{𝑍}$⁡(𝑡) defined through equilibrium time-correlation functions of heat fluxes. This function generalizes the conventional concept of steady-state thermal conductivity, governing the transition of conduction dynamics from onset second sound type wave propagation at finite speeds to diffusion-dominated behavior across broad temporal and spatial scales. Unlike phonon hydrodynamic models that rely on mesoscopic constructs such as phonon drift velocity, our approach provides a quantitative and microscopic description of intrinsic memory effects in transient heat fluxes and applies universally to bulk materials at any temperature or length scale. By integrating atomistic-scale first-principles calculations with continuum-level macroscopic equations, this framework offers a robust foundation for numerical simulations of transient temperature fields. Furthermore, it facilitates the interpretation and design of transient thermal grating experiments using nanometer-scale heat sources and ultrafast laser systems in the extreme ultraviolet and x-ray wavelength ranges, advancing our understanding of heat dissipation dynamics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Concept of Dynamic Heat Insulation for Rotating Detonation Engines

This work introduces a new class of materials concept to dynamically reduce instantaneous heat fluxes in Rotating Detonation Engine (RDE) combustor chamber walls. The high-frequency and high-amplitude surface heat fluxes observed in RDEs arise from large instantaneous temperature differences between the detonation shockwave and chamber wall surface. These temperature gradients drive substantial energy loss and reduce the chamber gas pressure, ultimately limiting the cycle’s thermodynamic efficiency. This work introduces a concept for dynamically insulating the combustion chamber surfaces using surface layers or coatings with low thermal time scale. With such coatings, the surface temperature may follow the fluctuations of the cyclic detonation wave temperature, thus reducing the instantaneous heat flux therefore cycle-mean heat flux. To analyze these cyclic thermal phenomena, a one-dimensional analytical conduction solver was utilized with the capability to handle multilayered structures. Parametric modeling was performed using transient heat flux boundary conditions representative of a hydrogen–air RDE across a broad range of coating thermal properties and engine conditions. The coating effectiveness scaled with the product of thermal time constant and detonation wave frequency and the results were non-dimensionalized to guide future materials development. This strategy may offer benefits in increasing material survivability, reducing cooling requirements, and enhancing pressure gain.

heat transfer↗

Low Thermal Conductivity and Diffusivity at High Temperatures Using Stable High–Entropy Spinel Oxide Nanoparticles

The realization of low thermal conductivity at high temperatures (0.11 W m –1 K –1 800 °C) in ambient air in a porous solid thermal insulation material, using stable packed nanoparticles of high-entropy spinel oxide with 8 cations (HESO-8 NPs) with a relatively high packing density of ≈50%, is reported. The high-density HESO-8 NP pellets possess around 1000-fold lower thermal diffusivity than that of air, resulting in much slower heat propagation when subjected to a transient heat flux. The low thermal conductivity and diffusivity are realized by suppressing all three modes of heat transfer, namely solid conduction, gas conduction, and thermal radiation, via stable nanoconstriction and infrared-absorbing nature of the HESO-8 NPs, which are enabled by remarkable microstructural stability against coarsening at high temperatures due to the high entropy. Furthermore, this work can elucidate the design of the next-generation high-temperature thermal insulation materials using high-entropy ceramic nanostructures.

thermal insulation↗

Power and particle exhaust for the ARC fusion power plant

To successfully show that fusion is an attractive energy source, the ARCTM fusion power plant will need to operate with a robust, integrated power and particle exhaust solution. To maximise ARC’s fusion power output while avoiding excessive erosion of the plasma-facing components, we will need to radiatively dissipate most of the power crossing the last-closed flux surface, injecting radiating impurities such as argon or neon to access divertor detachment. Divertor detachment will need to be integrated with a high-performance core plasma, and with efficient impurity pumping to prevent the accumulation of helium ash in the core. To access and control detachment in high-performance plasmas, we have designed ARC with up–down-symmetric divertors, with secondary X-points in long, tightly baffled outer legs. Using a core-edge modelling workflow, we predict that with this divertor design, ARC will access detachment with modest argon seeding in the divertor (c Ar,div ∼0.9%), which should have minimal impact on the core ( Z eff,core <0.5) for reasonable argon enrichment (c Ar,div /c Ar,core =6). Due to the high predicted divertor neutral pressure (p div ∼20 Pa), we predict that ARC will sufficiently pump helium to limit ash accumulation in the core (c He,core <2%) for a helium enrichment of c He,div /c He,core =0.4. ARC’s divertor design is expected to increase the stability of a detachment front in the outer divertor leg, helping to prevent divertor reattachment during smaller heat-flux transients such as scrape-off-layer filaments associated with the quasi-continuous exhaust regime. However, this buffering will not be sufficient to prevent divertor reattachment during large type-I edge-localised modes (ELMs), and as such these will need to be avoided on ARC. Experiments on SPARC will be used to select an integrated scenario which avoids or mitigates type-I-ELMs while maintaining access to detachment, good core fusion performance and sufficient impurity exhaust. SPARC experiments will also be used to finalise ARC’s divertor design, by studying the impact of magnetic and first-wall geometry on detachment stability, impurity enrichment and neutral baffling under conditions similar to those expected for ARC. In conclusion, our analysis finds that ARC will have a viable power and particle exhaust solution which is compatible with high-power operations, and this solution will be validated in experiments on SPARC.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A model to assess Zircaloy’s mechanical property changes following a transient beyond critical heat flux

Maintaining the integrity of nuclear fuel rods is essential for ensuring public health and safety in nuclear power generation. During reactor operation, this integrity is confirmed by demonstrating compliance with established regulatory acceptance criteria. For moderate-frequency events, such as limiting transients and anticipated operational occurrences (AOOs), the current fuel integrity criterion is based on preventing boiling transition. This criterion assumes that prevention of boiling transition will prevent excessive cladding heating and, thus, fuel failure during normal operations. While conservative, this approach places significant constraints on core design, fuel cycle economics, and a plant’s ability to perform major power uprates, leading to suboptimal fuel utilization and inefficient carbon-free energy production. A more efficient approach could be achieved by revising the failure criterion to a material-specific limit rather than strictly preventing the boiling transition, since boiling transition per se is not a cause of fuel cladding failure. Here, as a result, a new licensing framework based on material properties, termed time-at-temperature (t@T), is needed. This approach would allow for brief periods of post–critical heat flux operation during an AOO without compromising safety. Implementing the t@T licensing strategy requires a robust technical foundation in material properties, which must be established through comprehensive data collection on both unirradiated and irradiated fuel and cladding materials. This foundation would enable the development of a safety basis that ensures safe operation while providing greater flexibility and efficiency for reactor operation. This paper documents a thorough review of the available data to establish a baseline knowledge that can inform the development of cladding mechanical models, as well as identify experimental data gaps that need to be addressed in future research. Machine learning and data informatics were utilized to extract the importance of parameters on the t@T parameter. Industry tools were used to perform baseline analyses to define the relevant transient conditions for data analysis. The subsequent review successfully identified applicable experimental data, as well as sufficient data to evaluate changes in cladding mechanical properties following an AOO transient. Rather than developing new models, this work coupled existing irradiation annealing and recrystallization models to calculate changes in hardness, yield stress, and ultimate tensile stress following an AOO event. The findings from this review were summarized to highlight the experimental data needs required to fill remaining gaps and support the development of future t@T licensing methodologies.

Cladding performance↗

Thermal-Fluid and Thermal-Structural Response of the T-Tube Modular Divertor to Spatiotemporally Varying Heat Loads

Tungsten (W) is the leading candidate for divertor target plates because of its high melting point (>3000°C), thermal conductivity, and ultimate tensile stress. While W and its alloys are the only solid materials that can survive the high heat fluxes incident on the divertor, W’s low-ductility high ductile-to-brittle transition temperature of ~600°C and relatively low recrystallization temperature (RT) of ~1300°C pose structural (among other) challenges. The objective of this work is to estimate the thermal-fluid and thermal-structural performance of the helium (He)-cooled T-tube divertor, which was originally developed by the Advanced Reactor Innovation and Evaluation Study (ARIES) using numerical simulations. Here, predictions of temperature distributions across the plasma-facing structural component and surface pressures from computational fluid dynamics simulations are used to determine stress distributions using commercial structural finite element modeling software over a range of fusion-relevant conditions. The maximum allowable incident heat fluxes are determined based on the temperature limits imposed by the ITER elastic Structural Design Criteria for In-vessel Components (SDC-IC) and the maximum RT over a range of He mass flow rates and presented in the form of performance design charts. Our recent work found that thermal- structural criteria accounting for the low ductility of W in a finger-type modular divertor constrain the maximum incident heat fluxes to values well below the ITER specifications, and those based on considering only the RT demonstrate that integrated thermal-fluid and elastic structural performance evaluation are required for accurate assessment of divertor performance. This novel analysis of the T-tube considers how nonuniform and transient incident heat fluxes affect its thermal-fluid and thermal-structural performance, as well as the effect of volumetric heating, which can be as great as 27% of the power incident on the divertor surface. The W tile of the T-tube, with its relatively large plasma-facing area of ~15 cm 2 , will likely experience significant spatial variations in incident heat flux. This work therefore assesses whether steady-state incident heat flux profiles with a peak of 10 MW/m 2 and maximum heat flux gradients of 200 MW/m 2 per m exceed the structural limits imposed by the ITER elastic SDC-IC and the maximum RT over a range of fusion-relevant conditions. The effect of transient heat fluxes typical of plasma detachment and reattachment from the target plate due, for example, to gas injection are also evaluated

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental investigation of power transient flow boiling

To advance the mechanistic understanding of power transients in flow boiling, experimental investigations are performed to capture the thermal response of four different kinds of cladding materials, including FeCrAls, to Fuchs reactivity initiated accident transients and linear ramp power transients. The transition boiling regime is phenomenologically reflected in power-transient flow boiling, which is different from steady-state boiling. In light of this, the critical heat flux that is usually featured with temperature overshooting does not indicate thermal safety margin of cladding materials as conservatively as the maximum heat flux, which is greater than critical heat flux in the power transient boiling curve. This is physically attributed to the thermal energy deposition on the cladding wall. In addition, the thermal energy released from the cladding wall results in different boiling heat transfer coefficient for the decreasing and increasing power stages respectively during the Fuchs power transient. The maximum heat flux difference gap, which appears due to changes in cladding materials and transient time scales, is appreciable under an intermediate heat convection regime. However, this difference gap is gradually weakened by the progressive increasing of mass flux and/or inlet subcooling due to the enhanced dominance of heat convection over heat conduction. Finally, the small difference gap of maximum heat flux is found to be insignificant under the weak heat convection because of power transient induced annular flow instability.

42 ENGINEERING↗

Results of the CHF-SERTTA In-Pile Transient Boiling Experiments at TREAT

To advance the current understanding of heat transfer between nuclear fuel rod cladding and the surrounding coolant under transient scenarios involving critical heat flux (CHF), the CHF-Static Environment Rodlet Transient Test Apparatus (CHFSERTTA), an in-pile experiment, was developed for and irradiated in the Transient Reactor Test (TREAT) facility at Idaho National Laboratory. The CHF-SERTTA experiment consists of a hollow, borated stainless steel rod submerged in a static water pool. The rod, heated via the (n, a) reaction in boron-10, was designed for investigating in-pile transient heat transfer between the rod surface and the coolant, avoiding the complexity of including the heat transfer between the fuel, gas gap, and cladding in typical light-water reactor (LWR) fuel rods. The instrumentation package for CHF-SERTTA focused on capturing those data that best describe the heat transfer behaviour between the rod and coolant. This paper outlines the CHFSERTTA experiment design and presents the initial results of the experiment campaign.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗