Engineering PapersSearch

SEARCH · Engineering Papers

Results for “tower”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Exploring the Potential of Rainwater Harvesting for Cooling Towers: A Systematic Review and Regional Feasibility Assessment

Water scarcity has driven interest in rainwater harvesting, especially for U.S. industries like power and manufacturing, which dedicate a large percentage of their water needs to cooling towers. This paper provides a comprehensive systematic review of studies on the use of rainwater in cooling tower applications, along with an assessment of the regional feasibility of integrating RWH in U.S. manufacturing cooling towers. The systematic review examines the technical, economic, environmental, and policy feasibility of utilizing harvested rainwater, and the regional feasibility analysis evaluates the practical implementation of RWH in manufacturing cooling towers, considering factors such as regional RWH potential, water costs, state policies, and the industrial water use of manufacturing facilities per state. This study supports the hypothesis that RWH for cooling towers is technically feasible, economically viable, and environmentally beneficial. Harvested rainwater is naturally less conductive and soft, and rainwater reuse minimizes the ecological footprint. Supportive state policies, regional RWH potential, and rising water costs across the U.S. are important variables that may impact RWH adoption. The review highlights rooftop RWH as the most studied method and notes that implementing RWH requires infrastructure changes and filtration techniques. While initial investment costs may be high, operational and maintenance costs are low, making RWHS economically feasible over time. Regions with higher water costs and supportive policies are more likely to benefit from RWH adoption. The study provides a foundation for understanding the potential for using RWH in industrial cooling towers.

Cooling towers

Wind River Experimental Forest Subcanopy Tower Information Sheet

Wind River was one of three sites that collected 3d sonic anemometer data for an ICOS subcanopy observation study. The three sites were defined by the following features and terrain: a deciduous broadleaf forest in flat terrain (Lanžhot, Czech Republic), a coniferous forest in mountainous terrain (Renon, Italy), and a tall conifer forest in mountain-valley terrain (Wind River, USA). The Wind River subcanopy towers were deployed in a high LAI, old-growth evergreen conifer forest and collected approximately 11 months of data. The site is an ecologically rich temperate rainforest in the western Cascade Mountains, and the biological carbon sink and source strength has been measured since 1998 using eddy covariance on the top of a 74 m tall flux tower (currently called the Wind River NEON tower). Additionally, forest inventory records date back to the 1920s. In 2024, four subcanopy towers were installed near the Wind River NEON tower to measure wind flow in the understory canopy layer for better understanding canopy flow coupling and decoupling in the subcanopy and how this affects the interpretation of overstory fluxes. The subcanopy tower installation was done by Lawrence Livermore National Laboratory and Washington State University (WSU) with collaborations from the University of Utah and the National Ecological Observatory Network (NEON).

54 ENVIRONMENTAL SCIENCES

A tale of two towers: comparing NEON and AmeriFlux data streams at Bartlett Experimental Forest

Long-term ecological data are essential for detecting impacts of climate change and other global change factors, and for making informed predictions about future change. However, long-term measurements are rarely replicated at the site level, which raises questions about their representativeness. We used a multiscale approach to evaluate the agreement of parallel observations from AmeriFlux and NEON (National Ecological Observatory Network) towers at Bartlett Experimental Forest, New Hampshire, USA. The two towers are separated by a horizontal distance of 93 m. Here, we focused our analysis on standard meteorological variables; fluxes of CO 2 , sensible heat, and latent heat measured by eddy covariance; and phenology derived from PhenoCam imagery. Results suggest excellent agreement between AmeriFlux and NEON in meteorology and phenology, and good agreement in fluxes at the half-hourly scale. However, large disagreements in CO 2 and latent heat fluxes occurred at the annual scale, with implications especially for the forest carbon balance. The AmeriFlux tower measurements indicate a site that is close to carbon-neutral (-8 ± 65 g C m -2 y -1 , mean ± 1 SD), whereas the NEON tower measurements indicate a forest that is a carbon sink (-137 ± 10 g C m -2 y -1 ). Causes of this disagreement may include measurement height (26 m vs. 35 m), which resulted in different flux footprints being measured by the two towers, and differences in the flux measurement systems. Our results suggest the need for caution when attempting to merge long-term flux data from two different measurement platforms, and when using measurements from any one measurement platform to inform decision-making on issues related to carbon accounting or natural climate solutions.

Carbon cycle

Virtual tower measurements during the American WAKE ExperimeNt (AWAKEN)

Dual-Doppler lidar measurements were made during the American WAKE ExperimeNt to provide height-resolved measurements of wind speed and direction at multiple locations immediately south of the leading row turbines in the King Plains wind farm in Oklahoma. These so-called virtual tower measurements were performed to characterize the inflow into the wind farm and to assess possible upwind blockage effects due to the collective action of the wind farm. The campaign was conducted from 12 November 2022 to 17 October 2023, during which time 14 unique virtual tower locations were sampled with heights ranging from 240 to 490 m AGL. The wind retrieval algorithm provided estimates of the horizontal winds and their uncertainties with a vertical resolution of about 10 m, while also accounting for the tilt of the lidar platform. The virtual tower results are compared to collocated lidar wind profiling data at the A1 site, which was located roughly 2.4 rotor diameters south of the nearest turbine. The wind speed difference between the wind profiler and the virtual tower was found to be quite sensitive to atmospheric stability and wind direction below 250 m AGL. The largest differences were observed for inflow under stable conditions, where the profiler wind speeds were observed to be about 22% lower than the virtual tower near hub height. These results suggest that there are persistent horizontal gradients in the flow upwind of the wind farm which result in biased estimates using standard ground-based lidar wind profiling methods.

17 WIND ENERGY

WREF 3D Sonic Anemometer - Tower A / Raw Data

Tower A is one of four subcanopy towers that were installed in the WREF canopy across a transect distance of 200m. Tower A had two CSAT3-3D sonics mounted at a height of 2.7m a.g.l. One (A1) is facing 290 degrees; the second (A2) is facing 90 degrees. The towers were installed to observe flow just above the forest floor and to identify any advection flows in the canopy. These data were also part of a larger ICOS project looking at forest flow coupling/decoupling with tower sites in Italy and Czech Republic.

17 WIND ENERGY

TTP - WREF 3D Sonic Anemometer Tower D / Raw Data

Tower D is one of four subcanopy towers that were installed in the WREF canopy across a transect distance of 200m. Tower D had one CSAT3-3D sonic mounted at a height of 2.7 m a.g.l. The sonic is facing 290 degrees. The towers were installed to observe flow just above the forest floor and to identify any advection flows in the canopy. These data were also part of a larger ICOS project looking at forest flow coupling/decoupling with tower sites in Italy and Czech Republic.

17 WIND ENERGY

TTP - WREF 3D Sonic Anemometer Tower C / Raw Data

Tower C is one of four subcanopy towers that were installed in the WREF canopy across a transect distance of 200m. Tower C had one CSAT3-3D sonic mounted at a height of 2.7 m a.g.l. The sonic is facing 270 degrees. The towers were installed to observe flow just above the forest floor and to identify any advection flows in the canopy. These data were also part of a larger ICOS project looking at forest flow coupling/decoupling with tower sites in Italy and Czech Republic.

17 WIND ENERGY

TTP - WREF 3D Sonic Anemometer Tower B / Raw Data

Tower B is one of four subcanopy towers that were installed in the WREF canopy across a transect distance of 200m. Tower B had two CSAT3-3D sonics mounted at a height of 2.7 m a.g.l. One (B1) is facing 270 degrees; the second (B2) is facing 90 degrees. The towers were installed to observe flow just above the forest floor and to identify any advection flows in the canopy. These data were also part of a larger ICOS project looking at forest flow coupling/decoupling with tower sites in Italy and Czech Republic.

17 WIND ENERGY

Wildfire towers drive firebrand lofting: insights from coupled fire-atmosphere model simulations

Wildfire behavior is shaped by complex fire dynamics, with firebrands playing a critical role in spot fire ignition and fire spread. While previous studies have explored firebrand generation and transport, the specific role of towers and troughs from wildland fires in the lofting of firebrands remains unquantified. This study addresses that gap by using physics-based coupled fire-atmosphere model simulations to examine how wildfire towers (updrafts) and troughs (downdrafts) influence firebrand lofting. Our results show that the majority of firebrands (78.85%) are lofted from towers, where strong updrafts drive long-range transport. In contrast, only 21.15% of firebrands are lofted within troughs, where downdrafts cause most firebrands to fall near the fireline. We also find that firebrand size significantly influences lofting behavior, with smaller particles (1 mm radius) exhibiting the strongest correlation with updraft intensity. These findings highlight the dominant role of wildfire towers in promoting long-distance firebrand dispersal—an essential factor in rapid wildfire growth and wildland-urban interface (WUI) fire risks. By quantifying the relationship between firebrand lofting and fire-induced atmospheric features, this study provides critical insights to improve spot fire modeling, support mitigation planning, and enhance firefighter and WUI community safety in spot fire-prone regions.

54 ENVIRONMENTAL SCIENCES

AmeriFlux FLUXNET-1F US-TLR Timberlake Observatory for Wetland Restoration (TOWeR)

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-TLR Timberlake Observatory for Wetland Restoration (TOWeR). This is the FLUXNET version of the carbon flux data for the site US-TLR Timberlake Observatory for Wetland Restoration (TOWeR) produced by applying the standard ONEFlux (1F) software. Site Description - This tower is located in Timberlake Forest, a restored forested wetland located 4 km from Albermarle Sound on the North Carolina coast. The forest to the south of the tower had historically been ditched, drained and converted to agricultural land, and subsequently reforested with Black Gum and Cypress trees and naturally re-wetted in 2006. This southern region has a bottomland forest ecosystem which saw a large-scale succession event of pine trees following the reforestation efforts. The northern part of the forest had been ditched, but never drained or converted for other land uses. It is much wetter and more sparsely vegetated when compared to the southern region, and has a mixed bottomland forest and swamp ecosystem.

Rey-Sanchez, Camilo [North Carolina State Universi

Clean Water Production in Cooling Towers

This project developed and demonstrated a novel technology that produces clean water from cooling tower recirculating water by using the natural evaporation and condensation cycle inside cooling towers. The system captures the escaping plume and converts blowdown quality water into high purity water suitable for on-site reuse such as boiler feed. The technology uses electric fields to ionize exhaust plumes, charge the entrained droplets, and direct them toward collection electrodes where they coalesce and flow downward. This allows water recovery at a low energy cost while reducing visible plume emissions. In addition, we developed a complementary software platform that improves overall cooling tower performance. The system uses wireless sensors and physics-based machine learning algorithms to optimize key parameters of the cooling process. For power generation facilities, this increases the thermal efficiency of the cooling loop and condenser, resulting in measurable cycle efficiency gains. Improvements of one percent or more can deliver significant increases in electricity production for the same fuel input.

01 COAL, LIGNITE, AND PEAT

Application Potential of a Dew-Point Cooling Tower in Selected Energy Intensive Applications in Temperate Climate

In the article, the application potential of the dew-point cooling tower (DPCT) in selected energy-intensive applications in temperate climates was analyzed and discussed. The applications selected for analysis are power generation with natural gas turbines and chilled water air conditioning systems. The study is based on a mathematical model derived from a modified ε-NTU model. The model was validated against experimental results and showed satisfactory agreement with the experimental data. DPCT was compared with a typical cooling tower limited by the wet-bulb temperature (wet-bulb cooling tower, WBCT). The simulation results showed that DPCT is able to provide significant energy savings in energy-intensive applications; therefore, its application potential in temperate climates can be considered justified. In the case of gas turbines, DPCT was able to generate 2 to 10 percentage points more capacity than operating on outdoor air and 1.8 to 5 percentage points more than operating with WBCT. In the case of air conditioning systems, the system equipped with DPCT achieved EERs (energy efficiency ratios) higher by 1 to 7.2 compared to dry cooling and by 0.3 to 5.1 compared to systems equipped with WBCT. The annual energy savings obtained by the system with DPCT were 14.7 MWh compared to WBCT and 30 MWh compared to dry cooling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

A novel approach to increase accuracy in remotely sensed evapotranspiration through basin water balance and flux tower constraints

Remote sensing-derived evapotranspiration (RSET) products capture the spatiotemporal variations of evapotranspiration (ET) from field to basin scales with unprecedented details. However, their accuracy varies across RSET estimation methods and diverse hydroclimate regions. While ET modeling efforts to account for biophysical processes and controlling parameters have made good progress in recent years, a parallel approach of integrating in-situ ET with RSET could reduce biases in RSET products. Basin water balance ET (WBET) and flux tower ET are widely applied to evaluate RSET accuracy, yet such ET measurements are rarely used for RSET bias corrections, especially for large area applications. To address this issue, we propose a novel approach: the water balance equivalence (WABE) method, which generates spatially continuous WBET for correcting biases in RSET products. The WABE method computes synthetic WBET by integrating observed WBET and flux tower-derived FLUXCOM ET, which fills the spatial gaps of observed WBET and generates a spatially continuous WBET dataset. Synthetic WBET (2002–2015 annual average) of eight-digit hydrologic unit code (HUC8) basins across the conterminous United States (CONUS), constituting 44 % (887 out of 2035 basins) of CONUS basins, was determined within 2.0 % (RMSE = 12 %) of observed WBET at CONUS and between 1–12 % (RMSE = 3–33 %) across 18 regions in CONUS. With WABE-based bias corrections, the overall annual bias of RSET decreased from 10 % (RMSE = 34 %) to 6 % (RMSE = 26 %) across 37 flux tower sites. The WABE method offers a new approach for RSET accuracy improvement and shows great promise for large area implementations with a potential to yield substantial benefits for building accurate basin water budgets and water management decisions.

Khand, Kul

AmeriFlux US-TLR Timberlake Observatory for Wetland Restoration (TOWeR)

This is the AmeriFlux version of the carbon flux data for the site US-TLR Timberlake Observatory for Wetland Restoration (TOWeR). Site Description - This tower is located in Timberlake Forest, a restored forested wetland located 4 km from Albermarle Sound on the North Carolina coast. The forest to the south of the tower had historically been ditched, drained and converted to agricultural land, and subsequently reforested with Black Gum and Cypress trees and naturally re-wetted in 2006. This southern region has a bottomland forest ecosystem which saw a large-scale succession event of pine trees following the reforestation efforts. The northern part of the forest had been ditched, but never drained or converted for other land uses. It is much wetter and more sparsely vegetated when compared to the southern region, and has a mixed bottomland forest and swamp ecosystem.

Rey-Sanchez, Camilo [North Carolina State Universi

Drop Tower Statement of Work

This document details the needs and requirements for a propulsion-assisted drop tower system (further referenced simply as Drop Tower) to perform hardware testing at Lawrence Livermore National Laboratory (LLNL). LLNL is managed and operated by Lawrence Livermore National Security, LLC (LLNS) for the Department of Energy (DOE). LLNL requires a robust testing platform that will allow for the characterization of interactions between objects of interest. The initial siting of the equipment will be located in an existing test facility (B191). When another test facility becomes online, the objective will be to move the test capability to the new facility as a final location (B132N). The Drop Tower will be a cornerstone capability for testing and model validation for LLNL interested programs.

42 ENGINEERING

Field Validation of Electrochemical Water Filtration System on an Open Loop Cooling Tower at Nissan Manufacturing Plant in Canton, Mississippi

The U.S. Department of Energy Industrial Efficiency and Decarbonization Office’s Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized technologies in the industrial sector to help inform decisions towards accelerating commercialization and deployment. This ITV demonstration investigated the performance of an early-commercial electrochemical water treatment technology on a cooling tower at an automotive plant. Cooling towers are vital equipment for dissipating heat from industrial processes, but they face challenges related to scaling, corrosion, and the growth of biological contaminants. Effective cooling tower water treatment is therefore essential in reducing these contaminants and other total suspended solids (TSS) and total dissolved solids (TDS). Various treatment systems, such as sand-based filters, centrifugal separators, and disc filters are available, each having its advantages and drawbacks. ElectroCell Systems, a filtration technology provider, offers an electrochemistry-based water treatment system that is skid-mounted and can be configured as a side-stream filtration system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Field Validation of Electrochemical Water Filtration System on Open Loop Cooling Towers at Automotive Plants

Open loop cooling towers play a pivotal role in rejecting heat for chilled water systems serving industrial processes, heating, ventilation, and air conditioning loads. Exposure to outside conditions can present certain operating challenges to system performance including scaling, corrosion, and biological growth. These issues are mitigated through the use of effective cooling tower water filtration and treatment systems to reduce contaminants—along with other total suspended solids (TSS) and total dissolved solids (TDS)—in the system. The U.S. Department of Energy’s Industrial Efficiency and Decarbonization Office is interested in an electrochemical-based filtration system with the ability to remove TSS particulate down to 1 micron. The removal of finer particulates reduces the need for blowdown and, in turn, makeup water use and chemical treatment in the cooling tower. Additionally, the removal process can reduce fouling at the condensers, resulting in better heat exchange and energy savings. Two Industrial Technology Validation program projects validated the electrochemical water filtration system at the Toyota Motor Manufacturing, Mississippi plant in Blue Springs, Mississippi, and the Nissan Canton Vehicle Assembly Plant in Canton, Mississippi. Researchers found that installation of both systems resulted in water and chemical treatment savings with minimal impact on energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

MLBS tower profiling lidar

The tower profiling lidar #ZX300-1381 was deployed on top of the 30 m tall MLBS NEON tower in an Appalachian forest. Prior to being deployed at MLBS, this lidar was on top of the tower at WREF in Washington. The zip files contain high frequency data. The Excel files are 10-min averages.

17 WIND ENERGY