Topology Identification in Distribution Systems Using Line Current Sensors: An MILP Approach
Not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
Many distribution system operations (e.g., state estimation, control, fault detection/localization) rely on the assumption that the underlying topology is accurately defined. In general, topology identification is a challenging problem in distribution systems as these systems are unobservable with a very limited number of available measurements. In this paper, we tackle this problem by designing a compressive sensing framework that jointly estimates the systems states and network topology via an integrated mixed integer nonlinear program (MINLP) formulation. Here, two reformulations of the original MINLP problems are investigated. Firstly, in order to remove the nonlinearity in the MINLP formulation, a mixed integer linear programming (MILP) problem that employs auxiliary variables is derived. Furthermore, to achieve a faster solution, convex relaxation of the original formulation is derived. Finally, using a Markovian model for topology changes, prior information about system topology is used to improve topology identification particularly when a limited amount of measurements is available. Simulation results on IEEE 37-bus test feeder and IEEE 123-bus test feeder illustrate the efficiency and scalability of the proposed approaches from both state estimation and topology identification point of view (even with 30% of available data).
We present a method for joint phase identification and topology recovery in unbalanced three phase radial networks using only voltage measurements. By recovering phases and topology jointly, we utilize all three phase voltage measurements and can handle networks where some buses have a subset of three phases. Our method is theoretically justified by a novel linearized formulation of unbalanced three phase power flow and makes precisely defined and reasonable assumptions on line impedances and load statistics. We validate our method on three IEEE test networks simulated under realistic conditions in OpenDSS, comparing our performance to the state of the art. In addition to providing a new method for phase and topology recovery, our intuitively structured linearized model will provide a foundation for future work in this and other applications.
With the expansion of distribution networks and increased penetration of distributed energy resources (DERs), it is becoming increasingly important to obtain accurate distribution network topology in real-time. In this paper, a robust principal component analysis coupled deep belief network (PCA-DBN) surrogate model is proposed for distribution system topology identification. It integrates the benefits of robust feature extraction from PCA to deal with data quality issues and filter out noise, and the strength of DBN in capturing the nonlinear relationship between voltage amplitudes and the binary states of switchable connections. This also significantly reduces the DBN training complexity without loss of accuracy. It is shown that the widely used standard deviation of voltage drop and the voltage covariance matrix features yield less accuracy as compared to that of the voltage amplitudes in presence of high penetration of DERs and ZIP loads. Comparison results with other alternatives, such as the random forest (RF), multi-output regression (MOR) and the traditional DBN methods demonstrate that the proposed method can achieve a much higher topology identification accuracy while maintaining robustness to missing data and measurement noise under various penetration levels of DERs.
Recovering the distribution grid topology is essential to perform several distribution system operator functions. Many algorithms that address the topology recovery problem have already been proposed in the literature. Most are based on a priori information regarding which buses are fed by which substation; however, this information might not be available because frequent grid reconfigurations change the distribution grid portion connected to each substation. This paper addresses the problem of assigning every substation the set of buses that it is feeding, given field data. First, the aforementioned task is cast as a nonconvex optimization problem. Second, a relaxed version of the optimization problem is solved via the alternating direction method of multipliers. Finally, the performance of our approach is validated through numerical simulations of realistic scenarios using a standard IEEE benchmark feeder.
Abstract not provided.
Abstract not provided.
Graph signal processing (GSP) has emerged as a powerful tool for practical network applications, including power system monitoring. By representing power system voltages as smooth graph signals, recent research has focused on developing GSP-based methods for state estimation, attack detection, and topology identification. Included, efficient methods have been developed for detecting false data injection (FDI) attacks, which until now were perceived as non-smooth with respect to the graph Laplacian matrix. Consequently, these methods may not be effective against smooth FDI attacks. In this paper, we propose a graph FDI (GFDI) attack that minimizes the Laplacian-based graph total variation (TV) under practical constraints. In addition, we develop a low-complexity algorithm that solves the non-convex GDFI attack optimization problem using ell_1-norm relaxation, the projected gradient descent (PGD) algorithm, and the alternating direction method of multipliers (ADMM). We then propose a protection scheme that identifies the minimal set of measurements necessary to constrain the GFDI output to high graph TV, thereby enabling its detection by existing GSP-based detectors. Our numerical simulations on the IEEE-57 bus test case reveal the potential threat posed by well-designed GSP-based FDI attacks. Moreover, we demonstrate that integrating the proposed protection design with GSP-based detection can lead to significant hardware cost savings compared to previous designs of protection methods against FDI attacks.
Phasor measurement units (PMUs) are increasingly important for monitoring the state of an electrical power grid and quickly detecting topology changes caused by events such as lines going down or large loads being dropped. Phasors are complex‐valued measurements of voltage and current at various points of generation and consumption. If a line goes down or a load is removed, power flows change throughout the grid according to known physical laws, and the probability distribution of phasor measurements changes accordingly. This paper develops a method to estimate the current topology of a power grid from phasor measurements and considers the design goal of placing PMUs at strategic points in a distribution system to achieve good sensitivity to single‐line outages. From a vector of phasor measurements, probabilities are computed corresponding to the scenario that all power lines are operational and to alternate scenarios in which each line goes down individually. These probabilities are functions of the joint distributions of phasor measurements under each possible scenario, obtained through Monte Carlo simulations with random load profiles. We use log‐spline densities to estimate marginal distributions of phasor measurements and fold these into a multivariate Gaussian copula to capture important correlations. Sensitivity to outages varies according to which line goes down and where PMUs are placed on the grid. A greedy search algorithm is demonstrated for placing PMUs at locations that provide good sensitivity to single‐line outages. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.
Explore the source record for details and available documents.
This report explores the potential of distributed ledger technology (DLT) as a transformative tool to enhance fault-tolerant operations in electrical distribution systems. Leveraging DLT's core attributes, including an immutable decentralized ledger, distributed consensus mechanisms, and state replication capabilities, this study focuses on three critical use cases. A central aspect of this research centers on the utilization of a consensus-driven ledger, providing actors within the system, such as distributed resources, with access to a reliable data repository. This empowers these actors to collaborate effectively and make informed decisions, all securely recorded on the blockchain. The first use case concentrates on data configuration, utilizing mathematical criteria---particularly, the chi-squared test for gross error detection---to identify trustworthy sensors for advanced decision-making. Building upon this foundation of trust, the second use case, topology identification, accurately determines circuit breaker states, unveiling the distribution network's topology. Ultimately, the third use case leverages this trust to execute switching actions, reconfiguring feeders and restoring power to disconnected customers after fault events. The concept of trust serves as a cornerstone in this approach, marking a departure from traditional fault location, isolation, and service restoration (FLISR) methods. Additionally, the blockchain-based architecture introduces decentralization, empowering disconnected areas to make autonomous decisions, even when communication with a central control center is disrupted. The primary contributions of this report are twofold: (1) a novel approach for evaluating distribution system voltage areas while preserving data ownership and (2) the implementation of interactions between distribution network areas using the actor model. Unlike the previous sequential approach for evaluating the area connection voltages, which required a radial network topology, this study's area model reduction enables a more versatile approach. The area model reduction addresses issues of prolonged data waiting times and multiple points of failure within the previous approach. Notably, the presented evaluation for the reduced network model area connection reveals a significant increase in the differences in voltage magnitudes. Simulation and evaluation of area agents across four distinct cases elucidate the area-level interaction behavior during a fault event. Simulations demonstrate that the proposed distributed FLISR (DFLISR) approach can successfully restore service to an affected area. Varying message delays and message loss probabilities in each simulation case underscore their impacts on restoration times, ranging from 3 min and 32 s to 6 min and 19 s. In contrast, power is not restored in an area in one of our simulation cases.
Gaining knowledge of the intrinsic topology of a complex dynamical network is the precondition to understand its evolutionary mechanisms and to control its dynamical and functional behaviors. In this article, a general framework is developed to recover topologies of complex networks with completely unknown node dynamics based on Taylor expansion and compressive sensing. Numerical simulations illustrate the feasibility and effectiveness of the proposed method. Moreover, this method is found to have good robustness to weak stochastic perturbations. Finally, the impact of two major factors on the topology identification performance is evaluated. This method provides a natural and direct point to reconstruct network topologies from measurable data, which is likely to have potential applicability in a wide range of fields.
The measurement of primary π ± , K ± , p and $\bar{p}$ production at mid-rapidity (|y|< 0.5) in proton–proton collisions at $\sqrt{s}$ = 7 TeV performed with a large ion collider experiment at the large hadron collider (LHC) is reported. Particle identification is performed using the specific ionisation energy-loss and time-of-flight information, the ring-imaging Cherenkov technique and the kink-topology identification of weak decays of charged kaons. Transverse momentum spectra are measured from 0.1 up to 3 GeV/c for pions, from 0.2 up to 6 GeV/c for kaons and from 0.3 up to 6 GeV/c for protons. The measured spectra and particle ratios are compared with quantum chromodynamics-inspired models, tuned to reproduce also the earlier measurements performed at the LHC. Lastly, the integrated particle yields and ratios as well as the average transverse momenta are compared with results at lower collision energies.
Unveiling feeder topologies from data is of paramount importance to advance situational awareness and proper utilization of smart resources in power distribution grids. This tutorial summarizes, contrasts, and establishes useful links between recent works on topology identification and detection schemes that have been proposed for power distribution grids. The primary focus is to highlight methods that overcome the limited availability of measurement devices in distribution grids, while enhancing topology estimates using conservation laws of power-flow physics and structural properties of feeders. Grid data from phasor measurement units or smart meters can be collected either passively in the traditional way, or actively, upon actuating grid resources and measuring the feeder's voltage response. Analytical claims on feeder identifiability and detectability are reviewed under disparate meter placement scenarios. Such topology learning claims can be attained exactly or approximately so via algorithmic solutions with various levels of computational complexity, ranging from least-squares fits to convex optimization problems, and from polynomial-time searches over graphs to mixed-integer programs. Although the emphasis is on radial single-phase feeders, extensions to meshed and/or multiphase circuits are sometimes possible and discussed. Here this tutorial aspires to provide researchers and engineers with knowledge of the current state-of-the-art in tractable distribution grid learning and insights into future directions of work.
Distribution system model calibration is a key enabling task for incipient failure identification within the distribution system. This report summarizes the work and publications by Sandia National Laboratories on the GMLC project titled “Incipient Failure Identification for Common Grid Asset Classes”. This project was a joint effort between Sandia National Laboratories, Lawrence Livermore National Laboratory, National Energy Technology Laboratory, and Oak Ridge National Laboratory. The included work covers distribution system topology identification, transformer groupings, phase identification, regulator and tap position estimation, and the open-source release and implementation of the developed algorithms.
Distribution system fault/failure has a direct impact on customers. Distribution systems are not designed with the contingency of one or more elements failing as the transmission system, however, distribution systems are more likely to have faults in comparison to transmission and generation systems. Most of the distribution systems have a radial design with the protection system assumption of unidirectional power flow. The radial design results in the disconnection of customers for any given component failure. The rapid deployment of distributed energy resources conflicts with the assumption of unidirectional power flow. To maintain/improve the distribution system fault tolerance for a grid with high penetration of distributed energy resources requires improvement. Blockchain can add value to improve fault-tolerant grid operations. That can be achieved using blockchain’s core features of distributed consensus-based decision-making process and immutability. In the process of preparing for an event or system restoration, there is a need for reliable data and system situational awareness. The system situational awareness enables accurate planning for possible scenarios and system restoration after an event, an area where blockchain’s distributed architecture can help. The value of blockchain for a fault-tolerant grid operation is elaborated with three use cases: 1) fault location, isolation, and service restoration; 2) topology identification; and 3) data configuration. These use cases demonstrate how blockchain-based architecture can facilitate bridging the vulnerabilities of the existing implementation.
We present results from a novel strategy that enables concurrent identification of protein-protein interactions and topologies in living cells without specific antibodies or genetic manipulations for immuno/affinity purifications. The strategy consists of: (i) chemical cross-linking reaction: intact cell labeling with a novel class of chemical cross-linkers, protein interaction reporters (PIRs); (ii) two-stage mass spectrometric analysis: stage 1 identification of PIR-labeled proteins and construction of a restricted database by 2D-LC/MS/MS; and stage 2 analysis of PIR-labeled peptides by multiplexed LC/FTICR-MS; (iii) data analysis: identification of cross-linked peptides and proteins of origin using accurate mass and other constraints. The primary advantage of the PIR approach and distinction from current technology is that protein interactions together with topologies are detected in native biological systems by stabilizing protein complexes with new covalent bonds while the proteins are present in the original cellular environment. Thus, weak or transient interactions or interactions that require properly folded, localized, or membrane-bound proteins can be labeled and identified through the PIR approach. This strategy was applied to S. oneidensis bacterial cells and initial studies resulted in identification of a set of protein-protein interactions and their contact/binding regions. Furthermore, most identified interactions involved membrane proteins, suggesting the PIR approach is particularly suited for studies of membrane protein-protein interactions, an area under-represented with current widely-used approaches.