Nominal and adversarial synthetic PMU data for standard IEEE test systems

GridSTAGE (Spatio-Temporal Adversarial scenario GEneration) is a framework for the simulation of adversarial scenarios and the generation of multivariate spatio-temporal data in cyber-physical systems. GridSTAGE is developed based on Matlab and leverages Power System Toolbox (PST) where the evolution of the power network is governed by nonlinear differential equations. Using GridSTAGE, one can create several event scenarios that correspond to several operating states of the power network by enabling or disabling any of the following: faults, AGC control, PSS control, exciter control, load changes, generation changes, and different types of cyber-attacks. Standard IEEE bus system data is used to define the power system environment. GridSTAGE emulates the data from PMU and SCADA sensors. The rate of frequency and location of the sensors can be adjusted as well. Detailed instructions on generating data scenarios with different system topologies, attack characteristics, load characteristics, sensor configuration, control parameters are available in the Github repository - https://github.com/pnnl/GridSTAGE. There is no existing adversarial data-generation framework that can incorporate several attack characteristics and yield adversarial PMU data. The GridSTAGE framework currently supports simulation of False Data Injection attacks (such as a ramp, step, random, trapezoidal, multiplicative, replay, freezing) and Denial of Service attacks (such as time-delay, packet-loss) on PMU data. Furthermore, it supports generating spatio-temporal time-series data corresponding to several random load changes across the network or corresponding to several generation changes. A Koopman mode decomposition (KMD) based algorithm to detect and identify the false data attacks in real-time is proposed in https://ieeexplore.ieee.org/document/9303022. Machine learning-based predictive models are developed to capture the dynamics of the underlying power system with a high level of accuracy under various operating conditions for IEEE 68 bus system. The corresponding machine learning models are available at https://github.com/pnnl/grid_prediction.

99 GENERAL AND MISCELLANEOUS↗

Robust Distribution State Estimation for Reliable Locational Marginal Pricing under Cyber-Attacks

Here this paper examines the impact of false data injection (FDI) cyber-attacks on distribution system state estimation (DSSE) and the resulting distribution locational marginal price (DLMP) in power markets. Two robust high-breakdown regression estimators, namely S- and MM- estimators, are implemented to provide resistance against FDI attacks targeting measurements and grid topology, creating leverage points. The introduced estimators are compared to the weighted least squares (WLS) with a bad data detection and rejection module (BDD) and the robust Huber M-estimator. The proposed estimators are shown to be effective and compare favorably to both existing Huber M- and the WLS with BDD in the presence of topology FDI attacks. Both the S- and MM-estimators provide good performance in the case of clean and corrupted measurements. Their performance is comparable in this case to the Huber M- and the WLS, followed by a BDD module. The simulation considered a modified distribution IEEE 13 and 34-bus systems where the impact of FDI attack scenarios is shown on the state and the DLMP pricing in the presence of distributed Generation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Forced Power Systems Oscillations Due to Cyberattacks: Threats, Detection and Partial Mitigation

Forced oscillations in power systems can be caused by misconfigured controllers at generator stations. They can also be caused by cyberattacks against the exciters or governors. This paper explores the effects of forced oscillations from cyberattacks on generator excitation and governor systems and the effectiveness of a novel control system for a static var compensator in mitigating those oscillations to enhance transmission system resilience. A brief overview of oscillations, especially forced oscillations, within power systems is presented, along with an overview of cyberattacks on power systems. This paper also examines and implements FACTS devices to partially mitigate the forced oscillations created by cyberattacks by reducing the magnitude of the oscillations caused by the attack. The proposed approach is more effective against attacks targeting exciters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Protection Against Graph-Based False Data Injection Attacks on Power Systems

Graph signal processing (GSP) has emerged as a powerful tool for practical network applications, including power system monitoring. By representing power system voltages as smooth graph signals, recent research has focused on developing GSP-based methods for state estimation, attack detection, and topology identification. Included, efficient methods have been developed for detecting false data injection (FDI) attacks, which until now were perceived as non-smooth with respect to the graph Laplacian matrix. Consequently, these methods may not be effective against smooth FDI attacks. In this paper, we propose a graph FDI (GFDI) attack that minimizes the Laplacian-based graph total variation (TV) under practical constraints. In addition, we develop a low-complexity algorithm that solves the non-convex GDFI attack optimization problem using ell_1-norm relaxation, the projected gradient descent (PGD) algorithm, and the alternating direction method of multipliers (ADMM). We then propose a protection scheme that identifies the minimal set of measurements necessary to constrain the GFDI output to high graph TV, thereby enabling its detection by existing GSP-based detectors. Our numerical simulations on the IEEE-57 bus test case reveal the potential threat posed by well-designed GSP-based FDI attacks. Moreover, we demonstrate that integrating the proposed protection design with GSP-based detection can lead to significant hardware cost savings compared to previous designs of protection methods against FDI attacks.

Morgenstern, Gal↗

Cyber Attack Sequences Generation for Electric Power Grid

Security assessment of cyber-physical energy systems (CPESs) such as the electric power grid is a critical operation to maintain availability, reliability, and quality of service in the presence of persistent threats from malicious cyber actors. Existing security assessment approaches such as penetration testing and red teaming rely on subject matter expert experience and forensic cyber analysis of historical events to perform realistic, threat-informed assessments of CPES defense. CPESs have a large attack surface because of the heterogeneity and complexity of underlying topology, devices, measurements, and vulnerabilities. The aforementioned approaches lead to partial coverage of the attack surface with a large set of unknown but possible exploits. There is a need to automate the CPES attack surface discovery and contextualize it for relevant, highly probable, real-world attack scenarios. We propose a methodology and framework to facilitate the discovery of the CPES attack surface. We present a multilayer attack graph with ranked attack sequences to describe CPES failure scenarios. We present a work-in-progress framework that lists key components to automate the attack modeling and sequence generation. We demonstrate the published National Electric Sector Cybersecurity Organization Resource CPES failure scenario to highlight the trustworthiness of generated attack sequences.

Dutta, Ashutosh↗

Steady-State Analysis of Microgrid Distributed Control Under Denial of Service Attacks

Distributed control is an effective method to coordinate multiple components in a microgrid. It usually has mandatory requirements for communication graph topology; changing the topology unexpectedly could disrupt the operation of a distributed controller. A denial of service (DoS) attack blocks communication channels to cause variations in communication graph. Unforeseen topology changes render a controller to receive incomplete system information. Control decisions made based on incorrect information can lead to significantly reduced grid supporting capability. As a result, the vital power balance between generation and load may be challenged. Determining power balance requires steady-state power flow analysis; however, the cyber-induced steady-state analysis is not well studied in the literature. Here, in this article, we show that a cyber–physical microgrid with unknown DoS attacks has augmented uncertain power flow equations, whose special structure creates new computational issue to determining power balance. To deal with the issue, we develop a novel cyber-induced microgrid model: the cyber–physical system is transformed into a pure physical model, where the disruption effects of DoS in the cyber layer are shown to be equivalent to the variations of the physical model parameters. With the transformed system, we develop a sufficient condition to ascertain the system power balance under unknown DoS attacks. In addition, practical insights for resilient distributed control design are shown as well.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Community detection robustness of graph neural networks

Graph neural networks (GNNs) are increasingly widely used for community detection in attributed networks. They combine structural topology with node attributes through message passing and pooling. However, their robustness or lack thereof with respect to different perturbations and targeted attacks in conjunction with community detection tasks is not well understood. To shed light on latent mechanisms behind GNN sensitivity on community detection tasks, we conduct a systematic computational evaluation of six widely adopted GNN architectures graph convolutional network, graph attention network, graph sample and aggregate (GraphSAGE), differentiable pooling (DiffPool), minimum cut pooling (MinCUT), and deep modularity networks (DMoN). The analysis covers three perturbation categories: node attribute manipulations, edge topology distortions, and adversarial attacks. We use element-centric similarity as the evaluation metric on synthetic benchmarks and real-world citation networks. Our findings indicate that supervised GNNs tend to achieve higher baseline accuracy, while unsupervised methods, particularly DMoN, maintain stronger resilience under targeted and adversarial perturbations. Furthermore, robustness appears to be strongly influenced by community strength, with well-defined communities reducing performance loss. Across all models, node attribute perturbations associated with targeted edge deletions and shifts in attribute distributions tend to cause the largest degradation in community recovery. These findings highlight important trade-offs between accuracy and robustness in GNN-based community detection and offer insights into selecting architectures resilient to noise and adversarial attacks.

Goel, Jaidev [Virginia Polytechnic Inst. and State↗

High-Order Wall-Modeled Large-Eddy Simulation of High-Lift Configuration

This paper presents the assessment of several recent enhancements for a high-order wall-modeled large-eddy simulation (WMLES) approach and demonstrates order independence with a fixed data exchange location in the wall model. The two enhancements include the use of isotropic tetrahedral elements to improve accuracy and an explicit subgrid-scale model, the Vreman model, to improve accuracy and robustness. The [Formula: see text] study focused on the high-lift Common Research Model (HL-CRM) at the angle of attack of 19.57 deg, a benchmark problem from the 4th AIAA High-Lift Prediction Workshop. Solution polynomial orders of [Formula: see text], and 5 were used in the study. The study demonstrated [Formula: see text] independence in integrated forces, pitch moment, velocity profile in the wall-normal direction, and surface flow topology. It also showed that a [Formula: see text] order of at least 3 ([Formula: see text]) was needed to correctly predict the external inviscid flow and the surface flow topology. Thereafter, [Formula: see text] simulations over several other angles of attack demonstrated that the high-order WMLES approach can correctly predict the maximum lift and flow separation regions for HL-CRM with about 40 million degrees of freedom (DOF) compared to at least 250 million DOF required by second-order methods.

Engineering↗

WISP: Watching grid Infrastructure Stealthily through Proxies (Final Technical Report)

The complex interdependencies of cyber systems (sensors and communications), physical grids and associated electricity market operations make protecting electric power grids a significant challenge. The energy sector is constantly under new, targeted, advanced and dangerous cyber-attacks that have the potential to result in the loss of human life. These threats are further exacerbated by our need to modernize the grid. One focus of cyber security research in smart grids is the securing of the SCADA system through advanced intrusion detection systems (IDS) and bad data detection algorithms in state estimation. These methods either require full knowledge of the system topology and parameters or fail to understand the physical behaviors under attack. WISP (Watching grid Infrastructure Stealthily through Proxies) is designed to provide additional protection to the power grid using only publicly available data. In particular, WISP exploits the spatio-temporal nature of the real time locational marginal prices (LMPs), in conjunction with other information such as bids, weather, outages and load data to analyze anomalous power pricing behaviors and then correlate those observations to localize regions of interest and identify potential cyber events. WISP is non-intrusive as the tool is deployed as a service in the Cloud or on premise and provides reliable information to system operators for enhanced situational awareness, without impeding energy delivery functions. The WISP technology comprises three modules: the data-driven anomaly detection core, the vulnerability and risk analysis and the root cause analysis. The data-driven anomaly detection core performs the tasks of feature selection, anomaly detection and attack region localization. The vulnerability and risk analysis module provides system level information of the vulnerable variables and times, assisting the operators in selecting monitoring and protection nodes. The root cause analysis module takes the detection results and identifies potential operational conditions that contribute to the detected anomalies. In Phase I, we have demonstrated the feasibility and effectiveness of WISP. We developed a realistic electricity market simulator capable of generating normal and attack market data under various operational conditions. We developed a series of cyber-attack detection and analysis algorithms and evaluated them under multiple data sources. Finally, we integrated all modules into an end-to-end software, providing functions for data management, data analytics and visualization. Specifically, we have achieved: (i) real-time data acceptance from external utility interfaces with >99% acceptance rate; (ii) high performance anomaly detection algorithms with >98% detection accuracy and <0.1% false alarm rate; and (iii) ultra-low computing delay <50 milliseconds. Additionally, our team developed algorithms to identify the vulnerable variables in electricity market operations and root cause analysis functions to identify major contributors to the price spikes. These ancillary modules are necessary when deploying WISP in real world industry environment. In Phase II, we have demonstrated the effectiveness of WISP software on realistic largescale power systems. We performed red team testing for the Phase I WISP software and identified software vulnerabilities and implemented corresponding mitigation solutions. We adapted the electricity market simulator for the Texas synthetic 2000-bus system and generated datasets for the false data injection attacks. We created database and visualization interfaces for the Texas system and the ISO New England system. We performed software optimization in terms of operation efficiency, computing speed and detection accuracy. Finally, we tested the software on the Texas system and the ISO New England system and evaluated the detection performance. Overall, we achieved above 89% detection rate, below 3% false alarm rate and below 37 seconds of end-to-end detection delay.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Anomaly Detection and Mitigation for Dynamic Frequency Regulation in Hydropower-Battery Systems: Preprint

Hydropower operators and energy storage providers are increasingly interested in participating in frequency regulation services, driven by the incentives offered by independent system operators, such as the Pennsylvania-New Jersey-Maryland Interconnection (PJM), in a competitive electricity market. This transition, however, unfolds against the backdrop of a modernizing and rapidly digitizing power grid, exposing the integrated legacy infrastructure and vulnerable communication networks to a multitude of cybersecurity threats. These evolving threats not only endanger grid operations but also have the potential to trigger cascading disruptions across the broader grid network and influence regulation markets. This work presents an approach for developing an anomaly detection and mitigation system to address cybersecurity challenges during the participation of a hydropower-integrated battery energy storage system (BESS) in a frequency regulation market. The applied anomaly detector utilizes machine learning algorithms to provide detailed classification of cyber-physical events and provide a comprehensive situation awareness to grid operators. Later, the applied mitigation system triggers predefined corrective actions to minimize the impact of data integrity attacks on the regulation market and system stability. We evaluated the proposed approach on a fully active BESS topology using the slow regulation signal (Reg A) coming from the PJM market. Our simulation results reveal that the proposed approach performs well in detecting data integrity attacks within the allocated time frame and also minimizes the system's instability and economic loss during the participation of hydropower and BESS in the regulation market.

battery energy storage system↗

Anomaly Detection and Mitigation for Dynamic Frequency Regulation in Hydropower-Battery Systems

Hydropower operators and energy storage providers are increasingly interested in participating in frequency regulation services, driven by the incentives offered by independent system operators, such as the PJM Interconnection. This transition, however, unfolds against the backdrop of a modernizing and rapidly digitizing power grid, exposing the integrated legacy infrastructure to a multitude of cybersecurity threats. This work presents an approach for developing an anomaly detection and mitigation system to address cybersecurity challenges during the participation of a hydropower-integrated battery energy storage system (BESS) in a frequency regulation market. The applied anomaly detector utilizes machine learning algorithms to provide detailed classification of cyber-physical events. Later, the applied mitigation system triggers predefined corrective actions to minimize the impact of data integrity attacks on the regulation market and system stability. We evaluated the proposed approach on a hydropower-integrated BESS topology, specifically analyzing the slow regulation signal (Reg A) coming from the PJM market. Our simulation results demonstrate that the proposed approach performs well in detecting data integrity attacks within the allocated time frame and also minimizes the system's transient instability during the participation of hydropower and BESS in the regulation market.

battery energy storage system↗

Malicious Cyber Activity Detection using Zigzag Persistence

In this study we synthesize zigzag persistence from topological data analysis with autoencoder-based approaches to detect malicious cyber activity, and derive analytic insights. Cybersecurity aims to safeguard computers, networks, and servers from various forms of malicious attacks, including network damage, data theft, and activity monitoring. We focus on the cybersecurity domain and investigate the detection of malicious activity using log data. We consider the dynamics of the log data and explore the changing topology of a hypergraph representation of this data to gain insights into the underlying activity. These hypergraphs capture complex interactions between processes, together with their temporal information. To study the changing topology we use zigzag persistence, which captures how topological features persist at multiple dimensions over time. We observe that this detects malicious activity in a cyber data set. To automate this detection we implement an autoencoder trained on a vectorization of the resulting zigzag persistence barcodes. Our experimental results demonstrate the effectiveness of the autoencoder in detecting malicious activity. Overall, this study highlights the potential of zigzag persistence and its combination with temporal hypergraphs for analyzing cybersecurity log data and detecting malicious behavior.

hypergraphs, temporal hypergraph, topological data↗

Systematic planning of moving target defence for maximising detection effectiveness against false data injection attacks in smart grid

Abstract Moving target defence (MTD) has been gaining traction to thwart false data injection attacks against state estimation (SE) in the power grid. MTD actively perturbs the reactance of transmission lines equipped with distributed flexible AC transmission system (D‐FACTS) devices to falsify the attacker's knowledge about the system configuration. However, the existing literature has not systematically studied what influences the detection effectiveness of MTD and how it can be improved based on the topology analysis. These problems are tackled here from the perspective of an MTD plan in which the D‐FACTS placement is determined. We first exploit the relation between the rank of the composite matrix and the detecting effectiveness. Then, we rigorously derive upper and lower bounds on the attack detecting probability of MTDs with a given rank of the composite matrix. Furthermore, we analyse existing planning methods and highlight the importance of bus coverage by D‐FACTS devices. To improve the detection effectiveness, we propose a novel graph theory–based planning algorithm to retain the maximum rank of the composite matrix while covering all necessary buses. Comparative results on multiple systems show the high detecting effectiveness of the proposed algorithm in both DC‐ and AC‐SE.

24 POWER TRANSMISSION AND DISTRIBUTION↗

GridSTAGE (aka PowerDrone)

Simulation tool for electrical grid security. It is possible to select from pre-loaded power system topologies, enable different grid controls (like AGC, power system stabilizer), add faults, tweak different parameters, add pre-modeled attack scenarios, and run batch simulations to generate data needed for research.

Nandanoori, Sai Pushpak↗

Optimal D-FACTS Placement in Moving Target Defense Against False Data Injection Attacks

Moving target defense (MTD) is a defense strategy to detect stealthy false data injection (FDI) attacks against the power system state estimation using distributed flexible AC transmission system (D-FACTS) devices. However, existing studies neglect to address a fundamental yet critical issue, i.e., the D-FACTS placement, by assuming that all lines are equipped with D-FACTS devices. Here, to tackle this problem, we first derive analytical necessary conditions and requirements on the D-FACTS placement for a complete MTD. Further, we propose sufficient conditions using a graph theory-based topology analysis to ensure that the MTD under the proposed D-FACTS placement has the maximum rank of its composite matrix, which is indicative of the MTD effectiveness. Based on the analytical conditions, we design D-FACTS placement algorithms by using the minimum number of D-FACTS devices to achieve the maximum MTD effectiveness. A novel MTD-based ACOPF model, in which the reactance of D-FACTS lines is introduced as decision variables, is proposed to find a trade-off between the system loss and the MTD effectiveness. Numerical results on 6-bus, IEEE 14-bus, and IEEE 118-bus systems show the efficacy of MTDs using the proposed D-FACTS placement algorithms in maximizing the composite matrix rank and detecting FDI attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-Time Testbed for Studying Cyberattacks and Defense in DER-integrated Smart Inverter Systems

In this paper, we propose a Hardware-in-the-Loop (HIL) simulation testbed suitable for the implementation and testing of realistic cyberattacks on grid-tied smart inverter systems integrated with Distributed Energy Resources (DER) that use the Distributed Network Protocol-3 (DNP3) protocol for communications between grid components. Specifically, our testbed combines a Real-Time Digital Simulator (RTDS) NovaCor device, outfitted with GNETx2 network interface cards, a gridtied DER topology implemented via the RTDS software package RSCAD, and a custom virtual network that emulates a man in the middle attacker. The Man-in-the-Middle (MITM) attacker captures DNP3 traffic and falsifies telemetry data in DNP3 packets to trigger unwarranted commands from a DNP3 controller that exploit smart inverter grid support functions. We choose DNP3 and implement grid support functions according to the IEEE Std. 1547-2018 mandated for the interconnection and interoperability of DER power systems with associated power components. Furthermore, we develop a protocol payload agnostic attack detection framework that leverages the round-trip time (RTT) anomalies between DNP3 requests and responses and can detect the presence of attacks without having to analyze the payload’s contents, while balancing trade-offs between false alarm counts, missed detections, and time to detection. To facilitate further research, we publicly release benign and attack network traffic exchanged between various sensors, controllers, and actuators in our grid-tied inverter testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilient Operating Constraints for Power Distribution Systems under Setpoint Attacks

Integration and operation of distributed generation (DG) and energy storage (ES) in power distribution systems are enabled by communication networks and embedded sensor and control devices that increase the vulnerability of the systems to cyber-threats, broadening the attack surface and making adversary actions more unpredictable. This paper proposes a methodology that uses ellipsoidal approximations to quantify the potential damage caused by successful attacks that affect, directly or indirectly, the desired operation setpoints and may drive the power distribution operation to unsafe states by violating the limits of voltage or line flows. More specifically, a new methodology is introduced to find the optimal non-symmetric operating constraints that can be imposed to each DG and ES in order to guarantee that the power distribution system is resilient to any malicious setpoints. The proposed method takes as inputs the system topology, DG and ES capabilities, and load limits to solve a convex optimization problem formulated using linear matrix inequalities (LMIs) and the power flow equations. The proposed solution is agnostic to the attacker's action or load profile and it does not require any assumption about the location or means of the attack. The numerical results on a test distribution feeder with several DG and ES illustrate how the proposed resilient operating constraints guarantee the security of the power distribution system under setpoint attacks.