Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tissue-like”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Dynamic and Programmable Cellular-Scale Granules Enable Tissue-like Materials

Living tissues are an integrated, multiscale architecture consisting of dense cellular ensembles and extracellular matrices (ECMs). The cells and ECMs cooperate to enable specialized mechanical properties and dynamic responsiveness. However, the mechanical properties of living tissues are difficult to replicate. A particular challenge is identification of a cell-like synthetic component, which is tightly integrated with its matrix and also responsive to external stimuli. Here, we demonstrate that cellular-scale hydrated starch granules, an underexplored component in materials science, can turn conventional hydrogels into tissue-like materials when composites are formed. By using several synchrotron-based X-ray techniques, we reveal the mechanically induced organization and training dynamics of the starch granules in the hydrogel matrix. These dynamic behaviors enable multiple tissue-like properties such as programmability, anisotropy, strain-stiffening, mechanochemistry, and self-healability.

36 MATERIALS SCIENCE↗

Self-assembled elastomers with molecularly encoded tissue-like softness, strain-adaptive stiffening and coloration

The invention generally relates to linear-bottlebrush-linear copolymer blocks and methods of making and using same. The disclosed copolymer blocks can be useful in, for example, the formation of polymer networks that replicate biological stress-strain behavior. This abstract is intended as a scanning tool for purposes of searching in the particular art and is not intended to be limiting of the present invention.

Sheiko, Sergei↗

Ultra-Sharp Nanowire Arrays Natively Permeate, Record, and Stimulate Intracellular Activity in Neuronal and Cardiac Networks

Intracellular access with high spatiotemporal resolution can enhance the understanding of how neurons or cardiomyocytes regulate and orchestrate network activity and how this activity can be affected with pharmacology or other interventional modalities. Nanoscale devices often employ electroporation to transiently permeate the cell membrane and record intracellular potentials, which tend to decrease rapidly with time. Here, one reports innovative scalable, vertical, ultrasharp nanowire arrays that are individually addressable to enable long-term, native recordings of intracellular potentials. One reports electrophysiological recordings that are indicative of intracellular access from 3D tissue-like networks of neurons and cardiomyocytes across recording days and that do not decrease to extracellular amplitudes for the duration of the recording of several minutes. The findings are validated with cross-sectional microscopy, pharmacology, and electrical interventions. The experiments and simulations demonstrate that the individual electrical addressability of nanowires is necessary for high-fidelity intracellular electrophysiological recordings. This work advances the understanding of and control over high-quality multichannel intracellular recordings and paves the way toward predictive, high-throughput, and low-cost electrophysiological drug screening platforms.

36 MATERIALS SCIENCE↗

Intrinsically stretchable electrode array enabled in vivo electrophysiological mapping of atrial fibrillation at cellular resolution

Electrophysiological mapping of chronic atrial fibrillation (AF) at high throughput and high resolution is critical for understanding its underlying mechanism and guiding definitive treatment such as cardiac ablation, but current electrophysiological tools are limited by either low spatial resolution or electromechanical uncoupling of the beating heart. To overcome this limitation, here we introduce a scalable method for fabricating a tissue-like, high-density, fully elastic electrode (elastrode) array capable of achieving real-time, stable, cellular level-resolution electrophysiological mapping in vivo. Testing with acute rabbit and porcine models, the device is proven to have robust and intimate tissue coupling while maintaining its chemical, mechanical, and electrical properties during the cardiac cycle. The elastrode array records epicardial atrial signals with comparable efficacy to currently available endocardial-mapping techniques but with 2 times higher atrial-to-ventricular signal ratio and >100 times higher spatial resolution and can reliably identify electrical local heterogeneity within an area of simultaneously identified rotor-like electrical patterns in a porcine model of chronic AF.

60 APPLIED LIFE SCIENCES↗

Evaluation of an in vitro three-dimensional HepaRG spheroid model for genotoxicity testing using the high-throughput CometChip platform

Three-dimensional (3D) culture systems are increasingly being used for genotoxicity studies due to improved cell-to-cell interactions and tissue-like structures that are limited or lacking in 2D cultures. The present study optimized a 3D culture system using metabolically competent HepaRG cells for in vitro genotoxicity testing. 3D HepaRG spheroids, formed in 96- or 384-well ultra-low attachment plates, were exposed to various concentrations of 34 test articles, including 8 direct-acting and 11 indirect-acting genotoxicants/carcinogens as well as 15 compounds that show different genotoxic responses in vitro and in vivo. DNA damage was evaluated using the high-throughput CometChip assay with concurrent cytotoxicity assessment by the ATP assay in both 2D and 3D cultures. 3D HepaRG spheroids maintained a stable phenotype for up to 30 days with higher levels of albumin secretion, cytochrome P450 gene expression, and enzyme activities compared to 2D cultures. 3D spheroids also demonstrated a higher sensitivity than 2D cultures for detecting both direct- and indirect-acting genotoxicants/carcinogens, indicating a better prediction of in vivo genotoxicity responses. When DNA damage dose-response data were quantified using PROAST software, 3D spheroids generally had lower or similar benchmark dose values compared to 2D HepaRG cells and were more comparable with primary human hepatocytes. These results demonstrate that 3D models can be adapted to the CometChip technology for high-throughput genotoxicity testing and that 3D HepaRG spheroids may be used as a reliable and pragmatic in vitro approach to better support the hazard identification and risk assessment of potential human genotoxic carcinogens.

60 APPLIED LIFE SCIENCES↗