Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timelapse seismic monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Frio 2 : Raw CASSM Datasets

This submission contains the raw SEG-2 seismic datasets acquired in the CASSM experiment, part of the Frio-2 GCS pilot. The directory also includes the log files generated by the Geode seismograph (geometrics) used during acquisition. All SEG-2 files have a ".dat" suffix and log files have a ".log" suffix. Various supplementary files are also included (see below) including a set of flow and seismic models used in interpretation. The earlyGathers.tar.gz resource includes raw data acquired during system testing and pre-injection periods. All files correspond to the single source continuous active source seismic monitoring (CASSM) dataset described in the following papers. Daley, T.M., Solbau, R.D., Ajo-Franklin, J.B., and Benson, S.M. 2007, “Continuous Active-Source Seismic Monitoring of CO2 Injection in a Brine Aquifer”, Geophysics, Vol. 72, No. 5, p. A57-A61 Daley, T., Ajo-Franklin, J.B., and C. Doughty, 2011, “Constraining the reservoir model of an injected CO2 plume with crosswell CASSM at the Frio-II Brine Pilot”, International Journal of Greenhouse Gas Control (IJGGC), Vol. 5, No. 2, pp. 1022-1030. Zhu, T., Ajo-Franklin, J., and T. Daley, 2017, “Spatio-temporal changes in seismic attenuation caused by injected CO2 at the Frio-II pilot site, Dayton TX, USA”, Journal of Geophysical Research – Solid Earth, Vol. 122, No. 9, pp. 7156-7171. cassmDataRaw.tar : The main tar file containing all of the SEG-2 field records and the Geode log files. Stacking, time sampling (dt), and date information should be in the .log file. Each file corresponds to a single stacked gather for the single source deployed. Data was recorded on a 24 channel downhole hydrophone array. fieldNotes.tar : contains some of the scanned observer logs from the experiments as well as some planning images fieldPhotos.tar : contains a small set of photographs taken during the experiment frio_flow_seismic_models.mat : a matlab structure containing a set of flow and seismic models used in interpreting the CASSM data (see IJGGC paper).

GCS↗

Permanent Source - Distributed Acoustic Sensing (PESO-DAS) v1

The SOV/DAS software program focuses on seismic monitoring and data processing of permanent seismic sources Surface Orbital Vibrators (SOVs) and fiber-optics sensing Distributed Acoustic Sensing (DAS). Its key features include automated data processing of the continuous seismic monitoring data acquired with DAS, and output of processed shot gathers and QC plots. The software supports timelapse seismic for long-term reservoir monitoring, and is used for monitoring of geological carbon storage sites, geothermal reservoirs, and oil and gas, and in general subsurface resource management.

dos Santos Maia Correa, Julia [Lawrence Berkeley N↗

Carbon sequestration monitoring with acoustic double-difference waveform inversion: A case study on SACROC walkaway VSP data

Geological carbon sequestration involves large-scale injection of carbon dioxide into underground geologic formations and is considered as a potential approach for mitigating global warming. Changes in reservoir properties resulting from the CO{sub 2} injection and migration can be characterized using waveform inversions of time-lapse seismic data. The conventional approach for analysis using waveform tomography is to take the difference of the images obtained using baseline and subsequent time-lapse datasets that are inverted independently. By contrast, double-difference waveform inversion uses timelapse seismic datasets to jointly invert for reservoir changes. We apply this method to a field time-lapse walkaway VSP data set acquired in 2008 and 2009 for monitoring CO{sub 2} injection at an enhanced oil recovery field at SACROC, Texas. The double-difference waveform inversion gives a cleaner and more easily interpreted image of reservoir changes, as compared to that obtained with the conventional scheme. Our results from the applicatoin of acoustic double-difference waveform tomography shows some zones with decreased P-wave velocity within the reservoir due to CO{sub 2} injection and migration.

ACOUSTICS↗

Assessing Uncertainty and Repeatability in Time-Lapse VSP Monitoring of CO2 Injection in a Brine Aquifer, Frio Formation, Texas (A Case Study)

This study was done to assess the repeatability and uncertainty of time-lapse VSP response to CO 2 injection in the Frio formation near Houston Texas. A work flow was built to assess the effect of time-lapse injected CO 2 into two Frio brine reservoir intervals, the ‘C’ sand (Frio1) and the ‘Blue sand’ (Frio2). The time-lapse seismic amplitude variations with sensor depth for both reservoirs Frio1 and Frio2 were computed by subtracting the seismic response of the base survey from each of the two monitor seismic surveys. Source site 1 has been considered as one of the best sites for evaluating the time-lapse response after injection. For site 1, the computed timelapse NRMS levels after processing had been compared to the estimated time-lapse NRMS level before processing for different control reflectors, and for brine aquifers Frio1, and Frio2 to quantify detectability of amplitude difference. As the main interest is to analyze the time-lapse amplitude variations, different scenarios have been considered. Three different survey scenarios were considered: the base survey which was performed before injection, monitor1 performed after the first injection operation, and monitor2 which was after the second injection. The first scenario was base-monitor1, the second was basemonitor2, and the third was monitor1-monitor2. We considered three ‘control’ reflections above the Frio to assist removal of overburden changes, and concluded that third control reflector (CR3) is the most favorable for the first scenario in terms of NRMS response, and first control reflector (CR1) is the most favorable for the second and third scenarios in terms of NRMS response. The NRMS parameter is shown to be a useful measure to assess the effect of processing on time-lapse data. The overall NRMS for the Frio VSP data set was found to be in the range of 30% to 80% following basic processing. This could be considered as an estimated baseline in assessing the utility of VSP for CO 2 monitoring. This study shows that the CO 2 injection in brine reservoir Frio1 (the ‘C’ sand unit) does induce a relative change in amplitude response, and for Frio2 (the ‘Blue’ sand unit) an amplitude change has been also detected, but in both cases the uncertainty, as measured by NRMS indicates the reservoir changes are, at best, only slightly above the noise level, and often below the noise level of the overall data set.

54 ENVIRONMENTAL SCIENCES↗

Quantitative Monitoring for Enhanced Geothermal Systems Using Double-Difference Waveform Inversion with Spatially-Variant Total-Variation Regularization

Double-difference waveform inversion is a promising tool for quantitative monitoring for enhanced geothermal systems (EGS). The method uses time-lapse seismic data to jointly inverts for reservoir changes. Due to the ill-posedness of waveform inversion, it is a great challenge to obtain reservoir changes accurately and efficiently, particularly when using timelapse seismic reflection data. To improve reconstruction, we develop a spatially-variant total-variation regularization scheme into double-difference waveform inversion to improve the inversion accuracy and robustness. The new regularization scheme employs different regularization parameters in different regions of the model to obtain an optimal regularization in each area. We compare the results obtained using a spatially-variant parameter with those obtained using a constant regularization parameter. Utilizing a spatially-variant regularization scheme, the target monitoring regions are well reconstructed and the image noise is significantly reduced outside the monitoring regions. Our numerical examples demonstrate that the spatially-variant total-variation regularization scheme provides the flexibility to regularize local regions based on the a priori spatial information without increasing computational costs and the computer memory requirement.

ACCURACY↗

The direct-current response of electrically conducting fractures excited by a grounded current source

Hydraulic fracture stimulation of low permeability reservoir rocks is an established and cross–cutting technology for enhancing hydrocarbon production in sedimentary formations and increasing heat exchange in crystalline geothermal systems. Whereas the primary measure of success is the ability to keep the newly generated fractures sufficiently open, long–term reservoir management requires a knowledge of the spatial extent, morphology, and distribution of the fractures — knowledge primarily informed by microseismic and ground deformation monitoring. To minimize the uncertainty associated with interpreting such data, we investigate through numerical simulation the usefulness of direct-current (DC) resistivity data for characterizing subsurface fractures with elevated electrical conductivity by considering a geophysical experiment consisting of a grounded current source deployed in a steel cased borehole. In doing so, the casing efficiently energizes the fractures with steady current. Finite element simulations of this experiment for a horizontal well intersecting a small set of vertical fractures indicate that the fractures manifest electrically in (at least) two ways: (1) a local perturbation in electric potential proximal to the fracture set, with limited farfield expression and (2) an overall reduction in the electric potential along the borehole casing due to enhanced current flow through the fractures into the surrounding formation. The change in casing potential results in a measurable effect that can be observed far from fractures themselves. Under these conditions, our results suggest that farfield, timelapse measurements of DC potentials can be interpreted by simple, linear inversion for a Coulomb charge distribution along the borehole path, including a local charge perturbation due to the fractures. As a result, this approach offers an inexpensive method for detecting and monitoring the time-evolution of electrically conducting fractures while ultimately providing an estimate of their effective conductivity — the latter providing an important measure independent of seismic methods on fracture shape, size, and hydraulic connectivity.

30 DIRECT ENERGY CONVERSION↗

Multi-Scale Seismic Measurements for Site Characterization and CO2 Monitoring in an Enhanced Oil Recovery/Carbon Capture, Utilization, and Sequestration Project, Farnsworth Field, Texas

To address the challenges of climate change, significantly more geologic carbon sequestration projects are beginning. The characterization of the subsurface and the migration of the plume of supercritical carbon dioxide are two elements of carbon sequestration that can be addressed through the use of the available seismic methods in the oil and gas industry. In an enhanced oil recovery site in Farnsworth, TX, we employed three separate seismic techniques. The three-dimensional (3D) surface seismic survey required significant planning, design, and processing, but produces both a better understanding of the subsurface structure and a three-dimensional velocity model, which is essential for the second technique, a timelapse vertical seismic profile, and the third technique, cross-well seismic tomography. The timelapse 3D Vertical Seismic Profile (3D VSP) revealed both significant changes in the reservoir between the second and third surveys and geo-bodies that may represent the extent of the underground carbon dioxide. The asymmetry of the primary geo-body may indicate the preferential migration of the carbon dioxide. The third technique, cross-well seismic tomography, suggested a strong correlation between the well logs and the tomographic velocities, but did not observe changes in the injection interval.

Energy & Fuels↗